MAURY USCG vessel records
← All vessels

COLUMBIA

COLUMBIA is a 1982 towing vessel. The Coast Guard has recorded 26 inspections since 1993, most recently in May 2026, along with 8 deficiencies and 3 casualty investigations between 2006 and 2013.

Records from 1993 to 2026. Most recent: inspection, 20 May 2026.

Built
1982
Last inspected
20 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 20 May 2026
…with no type recorded14
Operational controls None recorded without a removal date
Years with a record 18 calendar years (1993–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI4276
207401
Flag
UNITED STATES
Maury page id
psix-207401

Documentation record

Registered dimensions (L × B × D)55.7 ft × 24.1 ft × 9.2 ft
Registered tonnagegross 82 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLOUIS G OTIS BOAT CO INC · KROTZ SPRINGS, LA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 July 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Simplified, Net Ton
82 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

USL 458 Tank Barge · MISLE 40844 · 7 March 2006 · activity 2624278MF 13 Tank Barge · MISLE 40961 · 17 January 2001 · activity 6965MF 13 Tank Barge · MISLE 40961 · 17 January 2001 · activity 150156DM 81-11 Tank Barge · MISLE 422523 · 18 March 1995 · activity 12490

Inspection history · 26

20 May 2026 Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8377497
15 April 2025 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8111744
8 August 2024 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7977054
8 August 2023 In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7754576
10 May 2023 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7685481
8 August 2022 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7528445
19 July 2022 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7510898
5 July 2022 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7497019
15 April 2021 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7175712
28 May 2013 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4606242
28 September 2011 Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4156674
20 April 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3457155
17 May 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2933159
17 May 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2933318
11 July 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2709466
7 March 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2624278
3 January 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2268264
17 January 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 6965
17 January 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 150156
9 January 2001 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1522325
19 November 1999 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1511216
14 July 1997 Uninspected Towing Vessel
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 779412
18 March 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 12490
21 July 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 11232
18 August 1993 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 118623
18 August 1993 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 662044

Deficiency record · 8

02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 15 April 2025 Resolved
An existing vessel may be deemed by the OCMI...to be in compliance with 46 CFR subpart 144 provided that...The vessel has been both in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by the OCMI. Marine Inspector identified holes and corrosion in the forward boatswains storage leaking water from the forward void. The forward void was opened by the crew and 29 inches of water was discovered. Vessel crew could not provide evidence of routine soundings or inspections of the void and was unaware of the water ingress. Vessel shall pump out the water in the forward void and a marine chemist shall certify the space prior to continued inspection by USCG marine inspectors. Vessel shall provide a repair proposal of the penetrations in the bulkhead and any other areas identified after inspection of the forward void. 46 CFR 144.200(b) 60c
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 15 May 2025
Resolved 21 April 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 15 April 2025 Resolved
A fixed fire pump must be capable of being energized remotely from a safe place outside the engine room and at the pump. Crew was unable to energize the fire pump from a safe space outside the engine room. After troubleshooting, crew was able to demonstrate proper functionality of the pump. 46 CFR 142.325(a)(2) 60c
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 15 May 2025
Resolved 15 April 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 April 2025 Resolved
The hose must be a lined commercial fire hose 15 meters (50 feet) in length, at least 40 millimeters (1.5 inches) in diameter, and fitted with a nozzle made of corrosion-resistant material capable of providing a solid stream and a spray pattern. 46 CFR 142.325(d) 17c
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2025
Resolved 16 April 2025
Resolution: Witnessed satisfactory test on board.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 15 April 2025 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. Marine Inspector identified a hole at the base of the starboard stack and a hole in the bulkhead in the upper engine room. Holes shall be sealed. 46 CFR 144.320(b)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 21 April 2025
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 April 2025 Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Marine Inspector identified several items in the first aid kit that were expired. Replace the expired items. 46 CFR 140.435 17c
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2025
Resolved 16 April 2025
Resolution: Observed satisfactory kit replacement on board.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 15 April 2025 Resolved
An existing vessel may be deemed by the OCMI...to be in compliance with 46 CFR subpart 144 provided that...The vessel has been both in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by the OCMI. Marine Inspector (MI) identified holes and corrosion in the forward hold bulkhead allowing ingress of water from the forward void. MI also identified 2 wasted frames in the bottom of the forward hold bilge that need to be cropped and renewed to the satisfaction of the attending MI. Vessel is permitted a one time transit to Dickinson Bayou to enact permanent repairs to the above identified areas to the satisfaction of the attending MI. Vessel must provide a plan to our office outlining how the forward void space will be monitored in the future. 46 CFR 144.200(b) 701c
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2025
Resolved 21 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 July 2022 Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. The life float had excessive wear and is not serviceable. Replace in-kind. Limited to a rivers route. 46 CFR 141.230
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 August 2022
Resolution: Lifefloat replaced in-kind.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 5 July 2022 Resolved
Inspections and tests of lifesaving equipment must be recorded in the TVR, official logbook, or in accordance with any TSMS applicable to the vessel. The following minimum information is required: the dates when inspections and tests were performed, the number or other identification of each unit inspected and tested, the results of the inspections and tests, and the name of the crew member, surveyor or auditor and any others conduction the inspections and tests: and receipts and other records documenting these inspections and test must be retained for at least 1 year after the expiration of the COI and made available upon request. Inspection records on board do not include an area for the life float under the life saving sections. Records to be kept for the life float inspections. 46CFR 141.235(b)(1)-(2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 August 2022
Resolved 8 August 2022
Resolution: Lifesaving equipment inspections are now documented in the ship's log.

Casualty record · 3

7 March 2006Routine · role: Involved in a Marine Casualty · activity 2624278
20 April 2009Routine · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · 1 dead · activity 3457155
28 May 2013Routine · role: Involved in a Marine Casualty · activity 4606242
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.