Records from 1996 to 2022. Most recent: inspection, 9 January 2022.
Documentation record
Registered dimensions (L × B × D)56.5 ft × 22.0 ft × 9.1 ft
Registered tonnagegross 95 / net 76
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALBERT ORTIS BOAT BUILDING INC · KROTZ SPRINGS, LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel
Hull shapeBox
Hull configurationMonohull
Hailing portTAMPA, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 28 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Simplified, Net Ton
95 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDQ8061MMSI 367642910 · active · compulsorily equipped · granted 21 February 2026, expires 21 February 2036
WDH6919MMSI 367642910 · expired · compulsorily equipped · granted 7 October 2014, cancelled 7 December 2024
WDF6946MMSI 367479490 · cancelled · compulsorily equipped · granted 19 February 2011, cancelled 19 August 2016
WDF2415MMSI 367003260 · cancelled · compulsorily equipped · granted 14 October 2009, cancelled 4 March 2011
WDE4234MMSI 367003260 · cancelled · compulsorily equipped · granted 18 April 2008, cancelled 8 October 2009
WDC3152MMSI 367003260 · cancelled · compulsorily equipped · granted 21 December 2004, cancelled 1 April 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s
MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 25
9 January 2022
Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7609643
27 October 2021
Annual Inspection · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7340914
11 July 2019
Administrative Inspection · Initial Certification · Deficiency Check · Examination of Repairs · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6920955
15 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6513193
7 December 2013
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4765638
7 December 2013
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4765647
7 December 2013
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4767421
4 December 2013
DAPI Audit · Industry Initiated Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4763434
12 July 2013
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4651300
12 July 2013
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4651425
20 April 2012
Administrative Inspection · DAPI Audit · MTSA/ISPS Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4290956
25 October 2010
MTSA Verification · Industry Initiated Exam · Administration · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3877352
12 April 2010
Uninspected Other · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3717077
12 April 2010
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3724903
24 May 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3234748
18 May 2006
MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2653219
2 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1965177
23 March 2003
Type not recorded
No type recorded · Station Sabine · USCG Heartland District (CGD-H) · Activity 1761503
19 November 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 772652
23 May 2000
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 23730
28 September 1999
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 433232
10 June 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 19133
2 April 1998
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 414411
2 September 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 150924
24 December 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 41552
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2020
Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. Found the emergency batteries for the navigation equipment installed under the wall mounted air conditioning unit. The A/C was found dripping water over the battery cover. Construct a suitable drain or cover for the A/C drainage to prevent water from dripping on the batteries or move the batteries to a suitable location. 46 CFR 143.300 (f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2020
Resolved 13 November 2020
Resolution: The operator constructed a drip shield and installed the shield over the batteries.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2020
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Found electrical conductors attached to the navigation light switches at the operating station installed with sharp bends, missing conductor insulation, and half severed creating resistance and heat when energized. Replace electrical conductors in kind so as to prevent sharp bends and minimize fire hazards. 46 CFR 143.300 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2020
Resolved 13 November 2020
Resolution: Sharp bends removed from conductor installations at the operating station. New conductors replaced previously damaged conductors found under the operating station.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 16 October 2020
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Found inoperable emergency lighting on the bridge and in the engine room. Repair or replace in kind. 46 CFR 143.410
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2020
Resolved 13 November 2020
Resolution: Emergency lighting found adequate throughout all working and living areas.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 October 2020
Resolved
Electrical equipment and systems must be maintained to ensure proper operation. Identified a wasted hose clamp on the port side generator when operationally tested. The cooling hose clamp failed when the system was in operation and coolant was leaking from the piping during the inspection. A crew member replaced the hose clamp in kind and the generator was placed back into operation. 46 CFR 143.205
Action required: 10 - Deficiency Rectified
Due 16 October 2020
Resolved 16 October 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 16 October 2020
Resolved
An existing vessel may be deemed by the OCMI to be in compliance with structural standards if the vessel has been in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by the OCMI. Identified a fracture in the keel located in compartment #2 (number fore to aft). Identified two bent transverse frames located in compartment #2, starboard side. Submit a repair proposal to the OCMI prior to completing repairs. Contact the USCG OCMI for a re-inspection once repairs are complete. 46 CFR 144.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2020
Resolved 13 November 2020
Resolution: Satisfactory repairs were made to the frames and keel in compartment number 2.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 16 October 2020
Resolved
Closure devices must be provided for deck house or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. The forward compartment number one has a wasted hatch gasket. Replace in kind. 46 CFR 144.320
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2020
Resolved 13 November 2020
Resolution: Compartment number one hatch gaskets were replaced in kind with new material.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 March 2020
Resolved
Deficiency Code 01199
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 25% of the vessels that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
CITE 46 CFR §136.202(a)
ACTION 705
ACTION CODE C
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 August 2020
Resolved 16 October 2020
Resolution: The operator complete a COI initial inspection and a temporary COI was issued.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018
Resolved
Vsl is broadcasting: Invalid Call Sign and invalid IMO #.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2018
Resolved 4 October 2018