Records from 1993 to 2025. Most recent: inspection, 23 July 2025.
Documentation record
Registered dimensions (L × B × D)56.3 ft × 24.0 ft × 9.1 ft
Registered tonnagegross 113 / net 77
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRAYCO SHIPBUILDERS & REPAIRS INC · BOURG, LA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBELLE CHASSE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 June 2025 · expires 31 July 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it77 - Regulatory (Subpart C or D), Net Ton
113 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 33
23 July 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8192554
29 March 2024
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7887072
4 August 2023
Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7735087
3 June 2023
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7745529
2 August 2022
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7500837
24 March 2021
Administrative Inspection · Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7161920
22 June 2017
MTSA Verification · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6183825
23 June 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5162495
23 June 2015
Administration · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5164892
27 January 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5061624
14 November 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5023449
15 September 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4987338
19 May 2014
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 4863677
8 May 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4856349
11 September 2011
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 4145188
25 July 2011
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4102764
29 July 2010
MTSA Verification · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3809342
17 November 2008
Administration
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3364671
8 February 2007
Type not recorded
No type recorded · Maritime Safety & Security Team New Orleans (91112) · Activity 2869874
23 December 2006
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 2848975
25 August 2006
MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2759720
24 August 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2776610
11 April 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2621751
11 April 2006
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2621828
29 September 2005
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2527052
18 April 2005
Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2336714
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979231
13 May 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 19431
12 August 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 171710
2 March 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 90872
2 March 1996
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 388561
22 June 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 97712
11 November 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 230125
08 - Alarms › N/A - No Subsystem › General alarm
Issued 2 August 2022
Resolved
This section does not apply to an excepted vessel as defined in § 136.110 of this subchapter.
(b) Each towing vessel must be fitted with a general alarm that:
(1) Is activated at each operating station and can notify persons onboard in the event of an emergency;
(2) Is capable of notifying persons in any accommodation, work space, and the engine room;
(3) Has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light that is identified with a sign that reads: “Attention General Alarm - When Alarm Sounds or Flashes Go to Your Station”
General alarm did not work under normal operating conditions or under backup power.
General alarm was rectified on site.
Action required: 10 - Deficiency Rectified
Resolved 2 August 2022
Resolution: Received video evidence of corrected deficiency.
Lifesaving
Issued 2 March 1996
Resolved
NAV RULES ONBOARD WAS A 1983 EDITION, ADVISED CAPT ON VESSEL HE NEEDED TO UPGRADE TO 1990 EDITION.
Condition: Unknown
Due 2 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 2 March 1996
Resolved
TWO PFD'S LOCATED ON THE BRIDGE WAS WITHOUT RETRO.
Condition: Unknown
Due 2 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 2 March 1996
Resolved
FIRE EXTINGUISHER LOCATED ON STARBOARD SIDE AFT WEATHER DECK WAS WITHOUT NAME PLATE OR LABELS.
Condition: Unknown
Due 2 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 2 March 1996
Resolved
CO2 EXTINGUISHER IN ENGINEROOM WAS PASTED DUE FOR ANNUAL SERVICE.
Condition: Unknown
Due 2 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 2 March 1996
Resolved
NO WASTE MANAGEMENT PLAN ONBOARD._x001C_
Condition: Unknown
Due 2 April 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past