W. G. SNYDER JR. ELEVATOR

W. G. SNYDER JR. ELEVATOR is a 1982 offshore supply vessel. The Coast Guard has recorded 30 inspections since 1996, most recently in May 2022, along with 37 deficiencies.

Records from 1996 to 2022. Most recent: inspection, 24 May 2022.

Built
1982
Last inspected
24 May 2022
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

------
208025
Flag
UNITED STATES
—
Maury page id
psix-208025

Inspections, by type

Years with a record 24 calendar years (1996–2022)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)64.0 ft × 24.0 ft × 4.4 ft
Registered tonnagegross 90 / net 82
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELEVATING BOATS INC · CAERNARVON, LA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Regulatory (Subpart C or D), Net Ton
90 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 30

24 May 2022 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7457950
5 May 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7190222
28 April 2020 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6944891
15 April 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6939335
16 September 2019 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6825383
30 April 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6673548
16 May 2018 Hull Examination · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6415704
1 May 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6403257
12 January 2017 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6070104
26 February 2016 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5822594
4 August 2015 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5205625
21 July 2015 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5191066
29 May 2014 Hull Examination · Administrative Inspection · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4872137
25 July 2011 Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4093670
29 April 2009 MTSA Verification · Re-Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3467082
20 March 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3168282
21 May 2007 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2936446
25 April 2006 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2632821
28 March 2005 COI Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2320950
4 March 2004 Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2015607
10 March 2003 Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1753967
7 March 2002 Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1490943
26 March 2001 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1448243
9 March 2000 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1361355
15 March 1999 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1397105
20 February 1998 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1430510
3 April 1997 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1385952
5 June 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1182902
23 February 1996 Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1353900
16 February 1996 Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363551

Deficiency record · 37

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 May 2021 Resolved
Vessel shall ensure that all electrical equipment shall be drip proof and the cable be properly maintained for damp or wet locations. Vessel's electrical junction box that connects the electrical wire to the electrical submersible fire pump was not sealed properly allowing water to enter with electrical tape around the junction. The electrical wire was cut and had interior wire exposed. 46CFR183.10-10 & 46CFR183.01-5
Action required: 60 - Rectify deficiencies prior to movement
Due 5 May 2021
Resolved 6 May 2021
Resolution: Vessel Rep provided photo of new CGB connector for submercible pump wire box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 May 2021 Resolved
Vessel shall maintain fuel hoses to adequately protect again fire and pollution. The starboard main fuel hose had evidence of chaffing. 46CFR182.20-40 & 46CFR182.01-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 6 May 2021
Resolution: Vessel rep provided photo of new hose installed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 5 May 2021 Resolved
Vessel shall log crane usage and pre-use inspection IAW manufacturer and COI requirement of NVIC 08-1991 and 46CFR107.258. Vessel had not logged any crane usage or pre-use inspections since 08JAN202 while the vessel had been operating until the end of APR2021.
Action required: 10 - Deficiency Rectified
Due 5 May 2021
Resolved 5 May 2021
Resolution: Management will send memo out to all Captains reguarding logging the crane usage and pre-usage inspection. USCG will be copied on memo.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 April 2020 Resolved
Vessels on Oceans routes are required to have 6 red hand flares and 6 orange smokes. Distress signals were expired. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 April 2020
Resolved 15 April 2020
Stability › Watertight Integrity › General
Issued 1 May 2018 Resolved
Make repairs to 2 inch hole in the deck, to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 1 May 2018
Resolved 17 May 2018
Resolution: Insert witnessed by attending Marine Inspector.
Engineering › Reduction Gearing/Clutches › Hose
Issued 1 May 2018 Resolved
Replace port clutch flexible hose to meet J 1942 standards.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 17 May 2018
Resolution: Witnessed replacement of hose.
Construction/Loadline › Structures › Machinery Space Opening
Issued 12 January 2017 Resolved
Repair crack in port engine room hatch and make all engine room hatches watertight.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 February 2017
Resolved 1 February 2017
Resolution: Repaired crack, replaced gaskets, and adjusted hatches.
Electrical › Electrical Distribution System (service) › Cable
Issued 12 January 2017 Resolved
Port battery box arcing and smoking due to improper cable connections from battery charger. Properly install battery charger.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 February 2017
Resolved 1 February 2017
Resolution: Charger connection made with permanent type connectors.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 January 2017 Resolved
Install guards in way of port and starboard main diesel engine shafts and exposed PTO shafts.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 February 2017
Resolved 1 February 2017
Resolution: Installed guards.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 January 2017 Resolved
Replace damaged insulation around exhaust piping.
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 1 February 2017
Resolution: Replaced exhaust lagging.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 12 January 2017 Resolved
Provide annual crane inspection report for both cranes.
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 1 February 2017
Resolution: Annual crane inspection reports provided.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 12 January 2017 Resolved
Properly mount junction box and support hanging wires in vicinity of outboard fuel tank.
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 1 February 2017
Resolution: Mounted junction box and supported cables.
Communications › Audible Communications › Horn/Whistle
Issued 12 January 2017 Resolved
All vessels 12m or more must be fitted with a whistle. Vessel's whistle is inpoerable. Prove proper operation of whistle.
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 1 February 2017
Resolution: Repaired whistle; operational test sat.
Communications › Radio Communications › VHF Radiotelephone
Issued 12 January 2017 Resolved
Provide onboard an emergency broadcast placard at the operating station.
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 1 February 2017
Resolution: Emergency broacast placard installed at operating station.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 12 January 2017 Resolved
Vessel's marine sanitation device is missing a certification label and the unit's manual is not onboard. Prove marine sanitation device approved/certified and installed in accordance with the manufacturers instructions.
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 16 February 2017
Resolution: Certification and manual onboard. Manual vague, and manufacturer out of business. USCG type approval for system valid until 2018. System function test sat.
Fire Fighting › Means of Escape › Blocked
Issued 12 January 2017 Resolved
Make engine room escape hatches operable from inside the space in accordance with the vessel's Operations Manual and 46 CFR 177.15.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2017
Resolved 8 March 2017
Resolution: Manufactured and installed securing dogs that are operable from both inside and outside space.
Construction/Loadline › Structures › Superstructure
Issued 4 August 2015 Resolved
the pilot house has a hole in the overhead and needs to be croped and renewed to good metal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 October 2015
Resolution: corrected
Construction/Loadline › Structures › Superstructure
Issued 4 August 2015 Resolved
Upper deck at pilot house has epoxy covering rusted out holes. Deck metal needs to be cropped and renewed to good metal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 October 2015
Resolution: Corrected
Construction/Loadline › Structures › Deck Plating
Issued 4 August 2015 Resolved
The deck in the pilot house is a wood deck and is rotted and weak. Needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 October 2015
Resolution: Corrected
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 4 August 2015 Resolved
Bilge high water sensor is broken and does not work.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 October 2015
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Junction Box
Issued 4 August 2015 Resolved
Junction box on outside of pilot house bulkhead is missing the face plate and is not watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 October 2015
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 4 August 2015 Resolved
Missing cover to the 220Volt outlet box to the dryer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 October 2015
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 August 2015 Resolved
Portable AC cord needs to be secured to bulkhead to allow access to breaker panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 October 2015
Resolution: Corrected
Electrical › Lighting (service) › Lighting Fixture
Issued 4 August 2015 Resolved
Lighting fixture in the head is broken and falling from the overhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 October 2015
Resolution: Corrected
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 May 2014 Resolved
Engine room bilge alarm inoperable. Provide functioning bilge alarm float switch
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2014
Resolution: bilge alarm operational.
Electrical › Lighting (service) › Conductor
Issued 29 May 2014 Resolved
Generator 12V power supply for fuel pump improperly spliced.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2014
Resolution: Repaired wired with approved connection.
Operations/Management › Drills/Instruction › Not Conducted
Issued 29 May 2014 Resolved
Drills not being conducted.
Due 29 May 2014
Resolved 29 May 2014
Resolution: Conducted drills during inspection. The drill were logged properly.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 29 May 2014 Resolved
Lifesavings maintenance not logged for Jun-Jul 2013, Sep13-Jan14 and April 14. Referred for enforcement.
Action required: 705 - Other - as specified
Due 29 May 2015
Resolved 12 January 2017
Resolution: Lifesaving maintenance being logged.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 May 2014 Resolved
Electrical wiring in overhead of engine room not properly supported.
Due 12 June 2014
Resolved 26 June 2014
Resolution: Properly supported electrical wiring through out vessel.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 29 April 2009 Resolved
Provide annual crane maintenance certs for both deck cranes.
Due 29 May 2009
Resolved 5 May 2009
Resolution: Crane certs provided by vsl.
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 May 2007 Resolved
Demonstrate proper operation of bilge alarms.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2007
Navigation › Piloting/Steering › Compass Deviation Table
Issued 21 May 2007 Resolved
Provide
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 21 May 2007
Fire Fighting › Fire Hoses › Condition
Issued 21 May 2007 Resolved
Renew port fire hose.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2007
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 21 May 2007 Resolved
Provide
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 May 2007 Resolved
Provide NUC lights.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2007
Documentation
Issued 23 February 1996 Resolved
PROVIDE ON BOARD A STABILITY LETTER ISSUED BY USCG MARINE SAFETY CENTER (GMSC).
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Documentation
Issued 23 February 1996 Resolved
PROVIDE ON BOARD A USCG-APPROVED OPERATING MANUAL; PENDING APPROVAL, VESSELMAY OPERATE WITH CURRENT OPERATING MANUAL.
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.