MAURY USCG vessel records
← All vessels

3RD COLD MIL

3RD COLD MIL is a 1989 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in April 2026, along with 23 deficiencies and 1 casualty investigation in 2014.

Records from 2014 to 2026. Most recent: inspection, 7 April 2026.

Built
1989
Last inspected
7 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDA8534
Flag
UNITED STATES
Maury page id
psix-20826

Documentation record

Registered dimensions (L × B × D)50.0 ft × 14.3 ft × 6.3 ft
Registered tonnagegross 30 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLARD MARINE INC · ANAHEIM, CA, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBON SECOUR, AL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 12 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Net Ton
30 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

7 April 2026 Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8344183
29 April 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8102595
7 November 2024 Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8031732
8 April 2024 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7891971
1 May 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7678554
17 January 2023 Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7610978
7 March 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7407013
15 April 2021 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7174234
1 December 2020 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7104479
28 July 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7024453
8 May 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6950177
20 March 2019 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6646233
6 December 2018 Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6592983
16 April 2018 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6392579
30 October 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6297895
12 June 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6176068
23 March 2017 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6110269
30 December 2016 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6064000
8 March 2016 DAPI Audit · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5829099

Deficiency record · 23

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 April 2024 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Marine Inspector found ring buoy floating light lanyard to have deteriorated. Replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 23 May 2024
Resolution: Vessel rep supplied photographic evidence of replaced lanyard. Marine Inspector reviewed and found satisfactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 April 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 23 May 2024
Resolution: Vessel rep supplied photographic evidence of station license. Marine Inspector reviewed and found satisfactory.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 May 2020 Resolved
On a vessel of atleast 26 feet a visual and audible alarm must be provided at the operating station to indicate a high water level in a space with a non-watertight closure, such as a non-watertight hatch on the main deck. Vessel does not have a bilge high level alarm in the aft shaft space. 46CFR182.530
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 27 June 2020
Resolved 28 July 2020
Resolution: High level alarm installed. Test sat
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 May 2020 Resolved
The shut off valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space it must be located so that the operator does not have to reach more than 12 inches into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Fuel shutoff valves are located in the engine room more than 12 inches from the opening. 46CFR182.455(b)(4)/46CFR182.20-40(b)(3)
Action required: 10 - Deficiency Rectified
Due 27 June 2020
Resolved 28 July 2020
Resolution: Installed pull cable on the Port side. Test Sat
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 May 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessels charts were not up to date. 46CFR184.420(a)(1)
Action required: 10 - Deficiency Rectified
Due 10 June 2020
Resolved 28 July 2020
Resolution: New up to date charts are on board.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 May 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Due 10 June 2020
Resolved 28 July 2020
Resolution: Vessel has valid Radio Safety Certificate and up to date log. Master has Marine Operator [name withheld]
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 May 2020 Resolved
A vessel must carry either a first aid kit approved under 160.041 or a kit with equivalent contents and instructions. Vessel had expired First Aid kit. 46CFR184.710
Action required: 10 - Deficiency Rectified
Due 10 June 2020
Resolved 28 July 2020
Resolution: Vessel has a first aid kit that meets the requirement.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 May 2020 Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crewmembers and the employers supervisory personnel. Vessel has not provided the vessel master and crewmembers with appropriate Drug and Alcohol training. 46CFR16.401
Action required: 10 - Deficiency Rectified
Due 27 June 2020
Resolved 28 July 2020
Resolution: Master and all crew members have documented EAP training.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 May 2020 Resolved
A vessel must carry one floating watertight, unless it is limited to daytime operations. Floating waterlight was inoperable. 46CFR180.70(d)
Action required: 10 - Deficiency Rectified
Due 10 June 2020
Resolved 28 July 2020
Resolution: Floating waterlight is working properly
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 8 May 2017 Resolved
Provide copy of DAPI supervisory training IAW 46 CFR 16.401
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 12 June 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 8 May 2017 Resolved
Document daily radio checks IAW 46 CFR 184.502 & 47 CFR 80.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 12 June 2017
Resolution: Verified radio log
Communications › Radio Communications › VHF Radiotelephone
Issued 8 May 2017 Resolved
Link VHF-DSC to GPS IAW 46 CFR 184.502 & 47 CFR 80
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 12 June 2017
Resolution: New radio with gps purchased and installed
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 May 2017 Resolved
Replace retro tape on ring life buoy with SOLAS tape IAW 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 12 June 2017
Resolution: Life ring tape replaced.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 8 May 2017 Resolved
Provide current copy of NAVRULES IAW 46 CFR 184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 12 June 2017
Resolution: New NAVRULES was purchased.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 May 2017 Resolved
Update first aid kit IAW 46 CFR 184.710 to meet 160.041 Q spec
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 12 June 2017
Resolution: First aid kit was updated.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 8 May 2017 Resolved
Provide two portable lights as required on 46 CFR 183.430.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 12 June 2017
Resolution: Portable lights were placed on the vessel.
Stability › Watertight Integrity › General
Issued 8 May 2017 Resolved
Adjust watertight hatch for proper seal IAW 46 CFR 179.360.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 12 June 2017
Resolution: Vessels watertight hatchs were serviced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 May 2017 Resolved
Provide all around anchor light IAW Rule 21 of NAVRULES.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 30 October 2017
Resolution: Anchor light was satisfactorily installed
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 8 May 2017 Resolved
Replace bilge PVC piping with rigid non-metallic hose in engine room and steering compartment IAW 46 CFR 182.720
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 30 October 2017
Resolution: Bilge piping in compliance with regulations was installed
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 4 April 2016 Resolved
No evidence of EAP training information on board. Provide proof of EAP training.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: Training cert provided
Lifesaving › Lifejacket/PFD (Type II) › Retroreflective Material
Issued 4 April 2016 Resolved
Two (2) life jackets retro reflective tape was damaged/peeling. Renew retro reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: replaced life jackets
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 April 2016 Resolved
Wiring in Bilge space and engine room was held up by zip ties. Properly secure all wiring.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: electrical wires properly supported.
Fire Fighting › Structural - Horizontal Zones › General
Issued 4 April 2016 Resolved
Forward part of engine room had one cable transit in overhead which had foam insulation missing. Make Engine room vapor tight going to bathroom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: boundary sealed with foam.

Casualty record · 1

26 March 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4838774
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.