MAURY USCG vessel records Sign in
← All vessels

3RD COLD MIL

3RD COLD MIL is a 1989 passenger vessel (inspected). The Coast Guard has recorded 42 inspections since 2001, most recently in April 2026, along with 59 deficiencies and 1 casualty investigation in 2014.

Records from 2001 to 2026. Most recent: inspection, 7 April 2026.

Built
1989
Last inspected
7 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA8534
Flag
UNITED STATES
366855390
Maury page id
psix-20826

Inspections, by type

…with no type recorded2
Years with a record 23 calendar years (2001–2026)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 14.3 ft × 6.3 ft
Registered tonnagegross 30 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLARD MARINE INC · ANAHEIM, CA, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBON SECOUR, AL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 12 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Net Ton
30 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP5719MMSI 366855390 · active · compulsorily equipped · granted 4 May 2024, expires 4 May 2034
WDA8534MMSI 366855390 · expired · compulsorily equipped · granted 30 May 2012, cancelled 6 August 2022
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 42

7 April 2026 Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8344183
29 April 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8102595
7 November 2024 Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8031732
8 April 2024 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7891971
1 May 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7678554
17 January 2023 Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7610978
7 March 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7407013
15 April 2021 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7174234
1 December 2020 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7104479
28 July 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7024453
8 May 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6950177
20 March 2019 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6646233
6 December 2018 Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6592983
16 April 2018 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6392579
30 October 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6297895
12 June 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6176068
23 March 2017 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6110269
30 December 2016 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6064000
8 March 2016 DAPI Audit · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5829099
28 August 2014 Type not recorded
No type recorded · Station Pensacola · USCG Heartland District (CGD-H) · Activity 4968466
8 May 2014 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4832329
26 March 2014 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4838774
31 January 2012 Administrative Inspection · Simplified Stability Test
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4235580
26 August 2011 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4127744
27 January 2011 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3934570
27 July 2009 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3547381
22 April 2009 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3458531
16 July 2008 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3269471
16 June 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3227261
27 June 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2975487
14 May 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2927989
2 May 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2913475
19 March 2007 Drydock Extension
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2890793
18 July 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2615775
28 March 2006 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2610922
23 May 2005 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2363548
24 February 2005 Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2298367
26 March 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2032060
12 May 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1791676
5 March 2003 Hull Examination · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1726996
7 March 2002 Deficiency Check · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1487361
22 March 2001 Plan Review "T" Boat · Initial Certification · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1440462

Deficiency record · 59

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 April 2024 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Marine Inspector found ring buoy floating light lanyard to have deteriorated. Replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 23 May 2024
Resolution: Vessel rep supplied photographic evidence of replaced lanyard. Marine Inspector reviewed and found satisfactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 April 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 23 May 2024
Resolution: Vessel rep supplied photographic evidence of station license. Marine Inspector reviewed and found satisfactory.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 May 2020 Resolved
On a vessel of atleast 26 feet a visual and audible alarm must be provided at the operating station to indicate a high water level in a space with a non-watertight closure, such as a non-watertight hatch on the main deck. Vessel does not have a bilge high level alarm in the aft shaft space. 46CFR182.530
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 27 June 2020
Resolved 28 July 2020
Resolution: High level alarm installed. Test sat
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 May 2020 Resolved
The shut off valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space it must be located so that the operator does not have to reach more than 12 inches into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Fuel shutoff valves are located in the engine room more than 12 inches from the opening. 46CFR182.455(b)(4)/46CFR182.20-40(b)(3)
Action required: 10 - Deficiency Rectified
Due 27 June 2020
Resolved 28 July 2020
Resolution: Installed pull cable on the Port side. Test Sat
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 May 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessels charts were not up to date. 46CFR184.420(a)(1)
Action required: 10 - Deficiency Rectified
Due 10 June 2020
Resolved 28 July 2020
Resolution: New up to date charts are on board.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 May 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Due 10 June 2020
Resolved 28 July 2020
Resolution: Vessel has valid Radio Safety Certificate and up to date log. Master has Marine Operator [name withheld]
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 May 2020 Resolved
A vessel must carry either a first aid kit approved under 160.041 or a kit with equivalent contents and instructions. Vessel had expired First Aid kit. 46CFR184.710
Action required: 10 - Deficiency Rectified
Due 10 June 2020
Resolved 28 July 2020
Resolution: Vessel has a first aid kit that meets the requirement.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 May 2020 Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crewmembers and the employers supervisory personnel. Vessel has not provided the vessel master and crewmembers with appropriate Drug and Alcohol training. 46CFR16.401
Action required: 10 - Deficiency Rectified
Due 27 June 2020
Resolved 28 July 2020
Resolution: Master and all crew members have documented EAP training.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 May 2020 Resolved
A vessel must carry one floating watertight, unless it is limited to daytime operations. Floating waterlight was inoperable. 46CFR180.70(d)
Action required: 10 - Deficiency Rectified
Due 10 June 2020
Resolved 28 July 2020
Resolution: Floating waterlight is working properly
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 8 May 2017 Resolved
Provide copy of DAPI supervisory training IAW 46 CFR 16.401
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 12 June 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 8 May 2017 Resolved
Document daily radio checks IAW 46 CFR 184.502 & 47 CFR 80.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 12 June 2017
Resolution: Verified radio log
Communications › Radio Communications › VHF Radiotelephone
Issued 8 May 2017 Resolved
Link VHF-DSC to GPS IAW 46 CFR 184.502 & 47 CFR 80
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 12 June 2017
Resolution: New radio with gps purchased and installed
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 May 2017 Resolved
Replace retro tape on ring life buoy with SOLAS tape IAW 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 12 June 2017
Resolution: Life ring tape replaced.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 8 May 2017 Resolved
Provide current copy of NAVRULES IAW 46 CFR 184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 12 June 2017
Resolution: New NAVRULES was purchased.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 May 2017 Resolved
Update first aid kit IAW 46 CFR 184.710 to meet 160.041 Q spec
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 12 June 2017
Resolution: First aid kit was updated.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 8 May 2017 Resolved
Provide two portable lights as required on 46 CFR 183.430.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 12 June 2017
Resolution: Portable lights were placed on the vessel.
Stability › Watertight Integrity › General
Issued 8 May 2017 Resolved
Adjust watertight hatch for proper seal IAW 46 CFR 179.360.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 12 June 2017
Resolution: Vessels watertight hatchs were serviced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 May 2017 Resolved
Provide all around anchor light IAW Rule 21 of NAVRULES.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 30 October 2017
Resolution: Anchor light was satisfactorily installed
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 8 May 2017 Resolved
Replace bilge PVC piping with rigid non-metallic hose in engine room and steering compartment IAW 46 CFR 182.720
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 30 October 2017
Resolution: Bilge piping in compliance with regulations was installed
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 4 April 2016 Resolved
No evidence of EAP training information on board. Provide proof of EAP training.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: Training cert provided
Lifesaving › Lifejacket/PFD (Type II) › Retroreflective Material
Issued 4 April 2016 Resolved
Two (2) life jackets retro reflective tape was damaged/peeling. Renew retro reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: replaced life jackets
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 April 2016 Resolved
Wiring in Bilge space and engine room was held up by zip ties. Properly secure all wiring.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: electrical wires properly supported.
Fire Fighting › Structural - Horizontal Zones › General
Issued 4 April 2016 Resolved
Forward part of engine room had one cable transit in overhead which had foam insulation missing. Make Engine room vapor tight going to bathroom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: boundary sealed with foam.
Documentation › Certificates/Documents › FCC SSL
Issued 16 June 2008 Resolved
Provide a current FCC radiotelephone certificate.
Action required: 705 - Other - as specified
Due 16 July 2008
Resolved 16 July 2008
Resolution: Valid Certificate issued.
Communications › Alarms/Indicators › High Water Alarm
Issued 16 June 2008 Resolved
Demonstrate proper operation of the foward compartment high water alarm audible indiactor at the pilot house.
Action required: 705 - Other - as specified
Due 16 June 2008
Resolved 16 June 2008
Lifesaving › Hand Flares › Storage
Issued 14 May 2007 Resolved
Provide a watertight container for the distress signals as per 46 CFR 180.68.
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 27 June 2007
Resolution: Provided a watertight container for the distress signals as per 46 CFR 180.68.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 14 May 2007 Resolved
Properly label the upper deck to not allow passengers as per 46 CFR 185.602.
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 27 June 2007
Resolution: Properly labeled the upper deck to not allow passengers as per 46 CFR 185.602.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 14 May 2007 Resolved
Properly clean and remove the loose paint from the lifejacket stowage area as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 27 June 2007
Resolution: Properly cleaned and removed the loose paint from the lifejacket stowage area as per 46 CFR 176.800.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 May 2007 Resolved
Replace the grabline and properly mark the ring lifebuoy as per 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 27 June 2007
Resolution: Replaced the grabline and properly marked the ring lifebuoy as per 46 CFR 185.604.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 May 2007 Resolved
Provide a Coast Guard approved first aid kit as per 46 CFR 184.700.
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 27 June 2007
Resolution: Provided a Coast Guard approved first aid kit as per 46 CFR 184.700.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 May 2007 Resolved
Provide a bilge high level alarm for the engine room as per 46 CFR 182.530.
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 27 June 2007
Resolution: Provided a bilge high level alarm for the engine room as per 46 CFR 182.530.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 14 May 2007 Resolved
Prove proper operation of the auxillary steering system as per 46 CFR 182.620.
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 27 June 2007
Resolution: Proved proper operation of the auxillary steering system as per 46 CFR 182.620.
Engineering › Fuel Oil Service System › Piping
Issued 14 May 2007 Resolved
Secure the fuel leaks at the strainer and at the fuel rack as per 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 27 June 2007
Resolution: Secured the fuel leaks at the strainer and at the fuel rack as per 46 CFR 182.455.
Engineering › Bilge Water Management System › Valve
Issued 14 May 2007 Resolved
Provide a positive shut off valve at the hull penetration for the bilge discharge line for the independent bilge pumps as per 46 CFR 182.520.
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 27 June 2007
Resolution: Provided a positive shut off valve at the hull penetration for the bilge discharge line for the independent bilge pump as per 46 CFR 182.520.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 May 2007 Resolved
Properly post the emergency instructions as per 46 CFR 185.510.
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 27 June 2007
Resolution: Properly post the emergency instructions as per 46 CFR 185.510.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 May 2007 Resolved
Provide a means of recovering an unconscious person from the water and properly stow the man overboard retrieval gear to make it readily accessible as per 46 CFR 180.
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 27 June 2007
Resolution: Provided a means of recovering an unconcious person from the water and properly stowed the man overboard retrival gear as to be readily accessible as per 46 CFR 180.
Construction/Loadline › Penetrations › Gasket
Issued 2 May 2007 Resolved
Prove the watertight integrity for the forepeak and engine room hatches as per 46 CFR 179.360.
Action required: 705 - Other - as specified
Due 2 June 2007
Resolved 14 May 2007
Resolution: Proved the watertight integrity of the forepeak and engine room hatches as per 46 CFR 179.360.
Construction/Loadline › Structures › Scuttle
Issued 2 May 2007 Resolved
Replace the broken hinges on the forward starboard void hatch as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 2 June 2007
Resolved 14 May 2007
Resolution: Replaced the broken hinges on the forward starboard void hatch as per 46 CFR 176.800.
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 March 2006 Resolved
Provide bridge log, lifesaving maintenance, training logbook with recent drills logged 46CFR185.420
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 21 July 2006
Resolution: Provided current bridge log, lifesaving maintenance, training logbook
Navigation › Piloting/Steering › US Coast Pilot
Issued 28 March 2006 Resolved
Provide current Coast Pilot, tide tables, tidal current table 46CFR184.420
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 21 July 2006
Resolution: Provided current Coast Pilot, tide tables, and tidal current tables
Construction/Loadline › Penetrations › Gasket
Issued 28 March 2006 Resolved
Provide proper gasket for anchor locker hatch (the one in use does not stay in place) 46CFR171.124
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 18 July 2006
Resolution: Provided proper gasket for anchor locker hatch
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 28 March 2006 Resolved
Mark ring buoy with vessel name. 46CFR185.604
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 18 July 2006
Resolution: Marked ring bouy with vessel name
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 March 2006 Resolved
Replace expired eyewash and aspiring in First Aid Kit. 46CFR184.710
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 18 July 2006
Resolution: Provide current first aid kit
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 28 March 2006 Resolved
Replace one A-II fire extinguisher with B-II extinguisher 46CFR181.500
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2006
Resolved 28 March 2006
Resolution: Provided B-II extinguisher
Fire Fighting › Fire Bucket › Stenciling
Issued 28 March 2006 Resolved
Label three firebuckets with "Firebucket" 46CFR181.610
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 21 July 2006
Resolution: Lebeled 3 firebuckets and attached lines to buckets
Fire Fighting › Fire Bucket › Lanyard
Issued 28 March 2006 Resolved
Attach line to one firebucket where missing 46CFR181.610
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 21 July 2006
Resolution: Attached lines to firebuckets
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 28 March 2006 Resolved
Tighten shaft log to a slow drip 46CFR176.802
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 18 July 2006
Resolution: Tightened shaft log to a slow drip
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 28 March 2006 Resolved
Post emergency checkoff list 46CFR185.510
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 18 July 2006
Resolution: Posted emergency checkoff list
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 28 March 2006 Resolved
Provide means for bringing an unconscious person on board vessel and life jacket with safety harness/line for crew member 46CFR177.100
Action required: 705 - Other - as specified
Due 11 April 2006
Resolved 21 July 2006
Resolution: Provided means a ladder to bring unconscious person on board and provided a safety harness with line for the crew member.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 March 2006 Resolved
Provide proof of new Certificate of Documentation
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 18 July 2006
Resolution: Provided new COD
Navigation › Piloting/Steering › Coast Guard Light List
Issued 4 May 2004 Resolved
Provide an updated version of Coast Guard Light List IAW 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 4 June 2004
Resolved 24 February 2005
Resolution: Light List was provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 May 2004 Resolved
Repair broken globe covering on starboard navigation light IAW 46 CFR 183.420.
Action required: 705 - Other - as specified
Due 4 June 2004
Resolved 24 February 2005
Resolution: Broken globe was repaired.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 4 May 2004 Resolved
Provide and post emergency broadcast placard IAW 46 CFR 184.506.
Action required: 705 - Other - as specified
Due 4 June 2004
Resolved 24 February 2005
Resolution: Emergency instructions were properly posted.
Documentation › Certificates/Documents › FCC SSL
Issued 4 May 2004 Resolved
Provide an FCC Safety Certificate and FCC Marine operator permit.
Action required: 705 - Other - as specified
Due 4 June 2004
Resolved 24 February 2005
Resolution: FCC Safety Certificate and Marine Radio Operators permit were provided-Valid.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 22 March 2001 Resolved
Provide grounding strap for fuel fill hose as required by 46 CFR 182.440
Condition: Unknown
Due 23 March 2001
Resolved 7 March 2002
Navigation › Piloting/Steering › Marine Charts
Issued 22 March 2001 Resolved
Provide updated charts and publications as required by 46 CFR 184.420.
Condition: Unknown
Due 22 April 2001
Resolved 7 March 2002
Documentation › Certificates/Documents
Issued 22 March 2001 Resolved
Provide FCC Certificates as required by 47 CFR 80.905. LEGACY COMPONENT DESC: FCC CERTS
Condition: Unknown
Due 22 April 2001
Resolved 5 March 2003
Resolution: FCC Certificates on board.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 22 March 2001 Resolved
Provide emergency broadcast placard as required by 46 CFR 184.506.
Condition: Unknown
Due 22 April 2001
Resolved 7 March 2002
Construction/Loadline › Structures › Scuttle
Issued 22 March 2001 Resolved
Provide securing lines for all unhinged hatches on deck as required by _x001C_ 46 CFR 171.124.
Condition: Unknown
Due 22 April 2001
Resolved 7 March 2002

Casualty record · 1

26 March 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4838774
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record