Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 8 inspections, each with its date, unit and type; 5 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 8
19 March 2026Examination of Repairs · COI Inspection · Hull Examination
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 2 May 2024Resolved
Vessel Type III was vented into the water making potential path for pollution of the federal waterways. Place sewage tank vent in an approvved location to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 6 May 2024
Resolution: Received objective evidence, scanned into documents.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 May 2022Resolved
Portable fire extinguishers did not have the annual servicing. Each portable fire extinguisher must be approved type. Conduct serving or replace portable fire extinguishers to the satisfaction of the attending Coast Guard Marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2022
Resolution: Received objective evidence fire extinguishers were serviced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 May 2022Resolved
Vessels main engine jacket water temp and low lube pressure gauges are not operational. Gauges to indicate
jacket water temp and low lube pressure must be provided at the operating station. Repair/replace operating gauges to the satisfaction of the attending Coast Guard marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 13 May 2022
Resolution: Received objective evidence guages installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 May 2022Resolved
Owner failed to conduct fire fighting drills for fall of 2021. The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties. Conduct drill to the satisfaction of the attending Coast Guard marine inspector.
Action required: 10 - Deficiency Rectified
Due 2 May 2022
Resolved 10 May 2022
Resolution: Conducted fire and many overboard with sat results.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 March 2021Resolved
Vessel did not have portable lights onboard. Each vessel must be equipped with at least two operable portable battery lights. Obtain portable lights to the satisfaction of the attending Coast Guard marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 30 March 2021
Resolution: Owner purchased portable lights and brought onboard.