MAURY USCG vessel records
← All vessels

VIKING

Built
1982
Last inspected
22 November 2024
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 22 November 2024
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 37 calendar years (1984–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WTH6411
208435
Flag
UNITED STATES
Tonnage
2243 - Convention (Subpart B), Gross Ton 673 - Convention (Subpart B), Net Ton
Maury page id
psix-208435
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

DAPHNE, EX USCGC DAPHNE (WPC 106) Towing Vessel · MISLE 80602 · 1 October 1993 · activity 124791

Inspection history · 71

22 November 2024 MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8027395
12 September 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7786982
17 July 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7744606
21 February 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7639708
17 November 2021 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7353170
9 August 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7281355
10 September 2020 Annual Inspection · Periodic Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7055545
13 February 2019 Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6625496
4 June 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6435238
27 July 2017 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6219234
27 July 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6244919
18 July 2016 Examination of Repairs · COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5967629
17 June 2016 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5910522
9 March 2016 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5830350
4 June 2014 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4879438
22 April 2014 MARPOL Annex VI Survey · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4862839
13 January 2014 Deficiency Check · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4782115
9 December 2013 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4766445
5 June 2013 Periodic Inspection · MARPOL Annex I Examination · Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4606350
12 July 2012 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4314855
1 April 2010 MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3702166
9 February 2009 Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3323341
7 November 2008 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3359253
28 July 2008 MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3281995
14 September 2007 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3057824
13 February 2006 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2584530
6 February 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2580353
20 May 2005 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2363427
20 April 2005 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2344086
4 April 2005 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2324597
6 January 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2270061
12 April 2004 Periodic Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2049914
22 March 2004 Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2029319
22 April 2003 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1778335
22 March 2002 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1495135
20 March 2001 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1461386
21 February 2001 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1386975
20 March 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1376140
25 June 1999 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1449203
15 December 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1408270
10 August 1998 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 796214
21 May 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1427517
11 August 1997 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1119218
14 July 1997 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 782900
3 September 1996 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1392532
14 February 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1417885
1 February 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1193693
20 July 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1355355
15 October 1993 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1353486
1 October 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 124791
1 October 1992 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1265266
9 December 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 943615
4 December 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 716332
12 November 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 941373
7 November 1991 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1252146
22 October 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 942114
16 October 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 942261
11 October 1991 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 937023
14 January 1991 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1228576
9 August 1990 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 914930
26 September 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1008328
9 August 1989 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1197770
28 September 1988 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 887130
28 September 1988 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1195566
13 September 1988 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1349730
25 August 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1039083
18 August 1987 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1030415
25 August 1986 Credit Drydock · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1296421
21 November 1985 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1303189
27 November 1984 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 977385
30 August 1984 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1284497

Deficiency record · 48

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 September 2020 Resolved
On vessels not over 25 gross tons, and on other vessels such as barges, where the framing of the certificate under glass would be impracticable, the original certificate of inspection shall be kept on board to be shown on demand. Original COI, IOPP, and IAPP were not onboard vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2020
Resolved 8 October 2020
Resolution: Provided evidence / Pictures of deficiencies rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2020 Resolved
Each outlet or junction box must be securely attached to its mounting and be affixed so as to maintain its designated degree of protection. Electrcal outlets or junction boxes were not properly secured and found to be hanging by its cable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2020
Resolved 8 October 2020
Resolution: Provided evidence / Pictures of deficiencies repaired.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 5 June 2013 Resolved
Provide Non-Conductive Matting at Switchboards as per 46 CFR 111.30-11.
Action required: 705 - Other - as specified
Due 5 July 2013
Resolved 8 July 2013
Resolution: Resolved to Marine Inspector satisfaction.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 5 June 2013 Resolved
Renew water light lines & grab line on 2 lifebuoys as per 46 CFR 199.70.
Action required: 705 - Other - as specified
Due 5 July 2013
Resolved 8 July 2013
Resolution: Resolved to Marine Inspector satisfaction.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 5 June 2013 Resolved
Provide Paint Locker in serviceable condition as per 46 CFR 92.05-10.
Action required: 705 - Other - as specified
Due 5 July 2013
Resolved 8 July 2013
Resolution: Resolved to Marine Inspector satisfaction.
Deck/Cargo › Cargo Stowage › General
Issued 12 July 2012 Resolved
Replace 6 weathertight gaskets on various doors as i.d.
Due 30 July 2012
Resolved 20 July 2012
Resolution: Def cleared
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 February 2009 Resolved
Repair #1 and #2 side longitudinals that are detached from the side shell in the forward port rake.
Action required: 705 - Other - as specified
Resolved 2 March 2009
Resolution: Welded #1 and #2 side longitudinals back to the side shell.
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 February 2009 Resolved
Re-attach the top longitudinal all the way forward to the side shell in #1P void.
Action required: 705 - Other - as specified
Resolved 2 March 2009
Resolution: Re-attached the top longitudinal to the side shell.
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 February 2009 Resolved
Repair bent flange on the #3 bottom transverse in the port aft rake.
Action required: 705 - Other - as specified
Resolved 2 March 2009
Resolution: Repaired bent flange on the #3 bottom transverse.
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 February 2009 Resolved
Repair the #1 and #8 bottom longitudinals that have cracked welds at the connection to the #1 bottom frame in the #5 port void.
Action required: 705 - Other - as specified
Resolved 2 March 2009
Resolution: Repaired both #1 and #8 bottom longitudinal cracked welds.
Construction/Loadline › Hull › Transverse Frame
Issued 9 February 2009 Resolved
Repair the hole in the #2 transverse frame on the inboard side of the #5 port void.
Action required: 705 - Other - as specified
Resolved 2 March 2009
Resolution: Cropped and renewed the hole in the #2 transverse frame.
Construction/Loadline › Hull › Bottom Plating
Issued 9 February 2009 Resolved
In the #5 port void, crop and renew entire bottom plating and replace all bottom longitudinals due to negative results on ultrasonic testing.
Action required: 705 - Other - as specified
Resolved 2 March 2009
Resolution: Cropped and renewed a 30ft X 17ft half inch steel plate as well as replaced all 4 X 8 X 5/16th bottom longitudinals.
Construction/Loadline › Hull › Bottom Plating
Issued 9 February 2009 Resolved
Crop and renew bottom plating from longitudinal #1-#6 forward and replace bottom longitudinals in this area due to negative results on ultra sonic testing.
Action required: 705 - Other - as specified
Resolved 2 March 2009
Resolution: Cropped and renewed a 8.5 X 10.5 ft bottom plate in damaged area as well as replaced the bottom longitudinals.
Engineering › Fuel Oil Service System › Filter
Issued 9 February 2009 Resolved
Provide 02 flame impingement bowls to the fuel filters in the engine space of the crane.
Action required: 705 - Other - as specified
Resolved 31 March 2009
Resolution: Installed 02 flame impingement bowls to the fuel filters in the engine space of the crane.
Construction/Loadline › Hull › Bottom Plating
Issued 9 February 2009 Resolved
Crop and renew to good metal the bulkhead and bottom plate between the #5 starboard and #5 center voids where the bulkhead has been distorted due to impact.
Action required: 705 - Other - as specified
Resolved 25 February 2009
Resolution: Inserted new platting on the bulkhead and bottom plate.
Engineering › Pressure Vessel
Issued 12 April 2004 Resolved
Correct/repair pressure relief valves for vessel's air receivers (2X), failure to reset. LEGACY COMPONENT DESC: Relief Valve
Action required: 705 - Other - as specified
Due 12 May 2004
Resolved 22 April 2004
Resolution: Witnessed sat seating of relief valves on both air receivers.
Electrical › Electric Generation Source (service)
Issued 12 April 2004 Resolved
Conduct sat overspeed trip on vessel's ssdgen in way of crane compartment. LEGACY COMPONENT DESC: Generator
Action required: 705 - Other - as specified
Due 12 May 2004
Resolved 22 April 2004
Resolution: Witnessed sat overspeed trip of SSDGEN.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 22 April 2003 Resolved
Install Hydrostatic release correctly.
Action required: 705 - Other - as specified
Due 22 April 2003
Resolved 22 April 2003
Electrical
Issued 14 July 1997 Resolved
REMOVE PORTABLE BATTERY CHARGER FROM RADIO BATTERY BANK.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Electrical
Issued 14 July 1997 Resolved
PERMANENTLY MOUNT SYNCH. A/C GENERATOR.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Engineering
Issued 14 July 1997 Resolved
PROVIDE SOLID BODY VALVES OR PLUGS, FOR ALL RACOR FILTERS (FUEL) THROUGHOUTMACHINERY SPACES. IF VALVES ARE INSTALLED, THEY MUST BE FITTED WITH PLUGS OR CAPS.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Documentation
Issued 3 September 1996 Resolved
PRIOR TO ENGAGING IN VOYAGE BEYOND THE BOUNDARY LINE, OBTAIN IOPP CERTIFICATE. TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI NO LATER THAN 03OCT96.
Condition: Unknown
Due 3 October 1996
Resolved 16 September 1996
Navigation
Issued 15 October 1993 Resolved
PROVIDE AND PERMANENTLY AFFIX A MEANS FOR DISPLAYING THE TOWING DIAMOND DAYSHAPE.
Condition: Unknown
Due 2 December 1993
Resolved 2 December 1993
Engineering
Issued 15 October 1993 Resolved
PROVIDE A SIGN WITH 1 1/2" BLOCK LETTERING, ON A CONTRASTING BACKGROUND, FOR EMERGENCY FUEL SHUT-DOWN.
Condition: Unknown
Due 2 December 1993
Resolved 2 December 1993
Engineering
Issued 15 October 1993 Resolved
PROVIDE COMPLETE FUEL OIL TRANSFER PROCEDURES AND LINE DIAGRAM AS PER 33 CFR 155.750
Condition: Unknown
Due 15 November 1993
Resolved 13 December 1993
Engineering
Issued 15 October 1993 Resolved
PROVIDE FUEL CONTAINMENT PLUG ON BOW FUEL VENT AND FILL AREA.
Condition: Unknown
Due 2 December 1993
Resolved 2 December 1993
Construction/Loadline
Issued 15 October 1993 Resolved
REPLACE VERTICAL ACCESS LADDER IN #2 PORT VOID DUE TO WASTAGE.
Condition: Unknown
Due 2 December 1993
Resolved 2 December 1993
Engineering
Issued 7 November 1991 Resolved
REMOVE FLEXIBLE HOSE BETWEEN FUEL TANK AND DAY TANK PRIOR TO VESSEL LEAVINGTHE MANSON DOCK BUT NLT 06DEC91. PUMPING SHALL ONLY BE PERFORMED IN DAYLIGHT HOURS AND WHILE UNDER DIRECT SUPERVISION.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Electrical
Issued 9 August 1990 Resolved
SECURE ALL OPEN ELECTRICAL JUNCTION BOXES.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Engineering
Issued 9 August 1990 Resolved
CONDUCT TEST ON YWO PV RELIEF VALVES, NOTE SETTING.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Documentation
Issued 9 August 1990 Resolved
CONDUCT ANNUAL LOADLINE SURVEY ON VESSEL. DUE 09AUG90
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Lifesaving
Issued 9 August 1990 Resolved
PROVIDE ANNUAL SERVICING TO INFLATABLE LIFERAFT, LAST SERIVCED 08AUG89.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Engineering
Issued 9 August 1990 Resolved
CONDUCT HYDRO. TEST ON TWO AIR RECIVERS, LAST HYDRO 25AUG88.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Fire Fighting
Issued 9 August 1990 Resolved
RECHARGE AND OR REPLACE PORTABLE FIRE EXTINGUISHERS AS NEEDED THROUGHTOUT THE VESSEL.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Electrical
Issued 9 August 1990 Resolved
PROVIDE HEAT REFLECTORS SHIELDS ON ALL RACOR FUEL FILTERS, WHERE MISSING.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Electrical
Issued 9 August 1990 Resolved
REPLACE ALL NON CG APPROVE FLEXIBLE FUEL LINE WITH CG APPROVED TYPE.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Electrical
Issued 9 August 1990 Resolved
REMOVE ALL WIRE NUTS AND PROVIDE MECHINCAL CONNECTIONS.
Condition: Unknown
Due 9 August 1990
Resolved 9 August 1990
Electrical
Issued 9 August 1989 Resolved
REPLACE COVER ON CIRCUIT BREAKER PANEL.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Electrical
Issued 9 August 1989 Resolved
BLANK OR PLUG HOLE IN LIGHT JUNCTION BOX.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Lifesaving
Issued 9 August 1989 Resolved
ANNUAL LIFE RAFT INSPECTION OVERDUE NEEDS TO BE SERVICED.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Electrical
Issued 25 August 1988 Resolved
REPLACE WIRE NUTS ON ELECTRICAL WIRING THROUGHOUT VESSEL.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Construction/Loadline
Issued 25 August 1988 Resolved
STENCIL AND PERMANENTLY AFFIX VESSEL'S NET TONNAGE TO VESSEL.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Navigation
Issued 25 August 1988 Resolved
REPAIR AND PROVE OPERATION OF VESSEL'S NAVIGATION LIGHTS.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Electrical
Issued 25 August 1988 Resolved
PROPERLY SUPPORT ELECTRICAL WIRING THROUGHOUT VESSEL.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Construction/Loadline
Issued 25 August 1988 Resolved
BRING HELICOPTER PLATFORM INTO COMPLIANCE WITH 46 CFR 108.653.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Accommodation/Occupational Safety
Issued 25 August 1988 Resolved
PROVIDE VESSEL'S HOT WATER HEATER WITH A 100 P.S.I. RELIEF VALVE.
Condition: Unknown
Due 25 August 1988
Resolved 25 August 1988
Unknown
Issued 18 August 1987 Resolved
PROVIDE A CURRENT FCC RADIO LICENSE.
Condition: Unknown
Due 18 August 1987
Resolved 18 August 1987
Electrical
Issued 18 August 1987 Resolved
INSTALL DRIP PROOF COVER ON ELECTRICAL MAIN DISTRIBUTION PANEL IN MAIN AND AUXILIARY GENERATORS.
Condition: Unknown
Due 18 August 1987
Resolved 18 August 1987

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.