Records from 1995 to 2026. Most recent: inspection, 30 March 2026.
Inspection history · 26
30 March 2026
Vessel Attendance · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8291750
27 May 2025
Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8146257
28 April 2025
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8108676
21 August 2024
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7984452
10 April 2024
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7890391
17 May 2023
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7680082
31 May 2022
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7452240
16 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7451934
13 November 2020
Initial Certification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7094753
20 May 2019
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6734523
2 November 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6573243
11 January 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6069640
9 August 2016
Type not recorded
No type recorded · USCGC LINE (WYTL 65611) · USCG Northeast District (CGD-NE) · Activity 5968422
9 August 2016
Type not recorded
No type recorded · USCGC LINE (WYTL 65611) · USCG Northeast District (CGD-NE) · Activity 5968468
13 November 2015
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5762763
8 July 2015
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5202062
12 May 2015
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5125157
2 November 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5017253
15 September 2014
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4983586
3 July 2013
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4643188
29 December 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3933317
22 November 2010
Industry Initiated Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3897654
10 December 1997
Uninspected Towing Vessel
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 780460
14 August 1997
Uninspected Towing Vessel
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1119313
8 April 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 157587
22 August 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 881030
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 March 2026
Resolved
Each lifebuoy on a towing vessel must: (4) Be marked in block capital letters with the name of the vessel. Observed Lifebuoys onboard not exhibit vessels name properly. Lifebuoys must be relabeled.
46 CFR 141.360 (b)(4)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 9 April 2026
Resolution: Vsl Rep emailed photos of new labeling on life rings.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 30 March 2026
Resolved
All pressure vessels must have the MAWP indicated by a stamp, nameplate, or other means visible to the crew. Observed no nameplate attached to pressure vessel. Provided permanent attached MAWP display to pressure vessel.
46 CFR 143.300 (c)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 9 April 2026
Resolution: Vsl Rep emailed photo of MAWP Labelled on the Pressure Vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2026
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Observed exposed electrical wiring in engine room at aft entrance. Secure wiring to prevent accidentally contact.
46 CFR 143.400 (g)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2026
Resolved 3 June 2026
Resolution: Marine Inspector received photo's of capped open end wiring.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 30 March 2026
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Observed Engine Room ventilation ducts without a means to secure ventilation. Provide covers for exhaust ducts.
46 CFR 144.605
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 29 April 2026
Resolution: Photos of Engine Room exhaust/intake covering received and uploaded to Documents tabs.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 March 2026
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either: (2) Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power. Observed no emergency lighting or lighting tape at either escape routes from engine room. Provide sufficient emergency lighting for space.
46 CFR 143.410 (a)(2)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2026
Resolved 29 April 2026
Resolution: Received photos of phosphorescent lighting tape installed in the engine room showing proper escape route.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 May 2025
Resolved
Propulsion machinery, including main engines, reduction gears, and shafting must be maintained to ensure proper operation.
Repairs to shafts and propellers must be made to the satisfaction of the Coast Guard prior to cargo operations.
46 CFR 143.205
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2025
Resolved 4 August 2025
Resolution: New shaft installed. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 28 April 2025
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Liferaft bracket, hydro-static release and associated equipment were missing.
46 CFR 141.230 - 701 C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 August 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Marine Inspector observed steering system not functional at the time of inspection. Vessel is required operational steering system for safe operation.
43 CFR 143.205
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 August 2024
Resolved 26 August 2024
Resolution: Steering tested SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 August 2024
Resolved
A sufficient amount of lined commercial fire hose 15 meters (50 feet) in length, at least 40 mm (1.5 inches) in diameter and immediately available to attach to it so that a stream of water will reach any part of the vessel. Marine Inspector observed hose ruptured at base of bracket rendering hose ineffective. Hose requires replacement.
46 CFR 142.325(e)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 August 2024
Resolved 26 August 2024
Resolution: Hose was replaced and fire pumps tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 August 2024
Resolved
A remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. Marine Inspector observed improper configuration on the Port side Fuel shutoff value restricting operation of value. Value requires full movement for operation.
46 CFR 143.260 (b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 August 2024
Resolved 26 August 2024
Resolution: Fuel Shut off operated as intended.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2024
Resolved
Each distribution panel or switchboard on a towing vessel must be: Totally enclosed and of the dead-front type. Marine Inspector observed circuit breaker without breaker, covered in tape. Circuit Breaker requires covering from protection of electrical shock and required each breaker to be labeled.
46 CFR 143.560(a) (2)
46 CFR 143.400(d)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 August 2024
Resolved 26 August 2024
Resolution: The panel was fitted with proper blanks.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2024
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Marine Inspector observed a electrical box in engine room bilge with exposed wiring. Electrical box is required to be in a enclosure.
46 CFR 143.400(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 26 August 2024
Resolution: Junction box was properly closed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 August 2024
Resolved
Pressure vessels must be externally examined annually. Relief valves must be tested in accordance with 46 CFR 143.245. Marine Inspector observed Pressure Vessel relief value with no tag. Relief value needs to be replaced.
46 CFR 143.300(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 26 August 2024
Resolution: The relief valve was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 August 2024
Resolved
Life jackets must have the following attachments and fittings: (1) Each life jacket must have a life jacket light securely attached to the front shoulder area of the life jacket. (2) Each life jacket must have a whistle firmly secured by a cord to the life jacket. Marine Inspector observe all life jackets with either a Light or Whistle secured to the jacket. All life jackets requires a whistle and light.
46 CFR 141.340(g) (1-2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 26 August 2024
Resolution: All jackets were fitted with lights and whistles.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 21 August 2024
Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation: (a) Fathometer. Marine Inspector observed depth sounder not functional. Fathometer is required to be operational.
46 CFR 140.725(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 20 November 2024
Resolution: depth sounder installed
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 21 August 2024
Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. Marine Inspector observed exposed exhaust piping in engine room on both main engines. All exposed exhaust piping is required protection from injury.
46 CFR 144.830
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 26 August 2024
Resolution: Lagging was properly fitted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2024
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Marine Inspector observed loudhailer bracket broken and hanging by electrical wiring in engine room. All electrical components are required to be suitably installed.
46 CFR 143.400(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 26 August 2024
Resolution: Loadhailer speaker was properly mounted.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 21 August 2024
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire. Marine Inspector observed engine room ventilation openings without sufficient means for closing. Ventilation intakes are required a covering to enclosed machinery spaces.
46 CFR 144.605
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 26 August 2024
Resolution: The intakes are piped directly into the engine intake. No cover is is required.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 21 August 2024
Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. Marine Inspector observed no navigational watch assessments recorded in log nor checklist in accordance with requirements in 46 CFR 140.635. Vessel is required Navigation Assessments prior to getting underway.
46 CFR 140.635(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 26 August 2024
Resolution: Nav assessment was in the pilot house.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 21 August 2024
Resolved
Chemical testing of personnel must be conducted as required by this subpart and in accordance with the procedures detailed in 49 CFR part 40. Marine Inspector observed no records of drug and alcohol testing records for crew members since 2022 and no on board testing equipment. Vessel is required a drug and alcohol surveillance program.
46 CFR 16.201(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2024
Resolved 20 November 2024
Resolution: Proof of DAPI documentation received.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 17 May 2023
Resolved
Piping and machinery components that exceed 220 degrees Celsius must be insulated.
Marine inspector observed torn insulation on the exhaust for the starboard main engine.
46 CFR 143.220(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 8 June 2023
Resolution: Vessel rep used high temp insulation wrap on stbd side engine exhaust.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 17 May 2023
Resolved
Each life float must be fitted with a floating electric water light approved under approval series 161.010.
Marine inspector observed that the life float water light had an expired battery.
46 CFR 141.325(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 8 June 2023
Resolution: Vessel rep replaced battery.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 17 May 2023
Resolved
Each life float must be fitted with a painter. Marine inspector observed that the painter was attached the vessel, and would not break free should the vessel sink in water deeper than the length of the painter.
46 CFR 141.325(c)
46 CFR 160.073
Action required: 705 - Other - as specified
Due 24 May 2023
Resolved 8 June 2023
Resolution: Vessel rep fitted life float with a float free link.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 May 2023
Resolved
Machinery systems must be maintained to provide for safe operation of the towing vessel and safety of persons on board. Marine inspector observed oil build up on the forward side of the generator winding.
Recommend Megger Test to confirm generator continuity and assure windings are in satisfactory condition.
46 CFR 143.205(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 8 June 2023
Resolution: Generator was cleaned and verified to be operating properly.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 17 May 2023
Resolved
Each towing vessel must be maintained so as to minimize fire hazards to ensure all bilges and void spaces are
kept free from accumulation of combustible and flammable
materials and liquids.
Marine inspector observed approximately 2" of oily water built up in the bilge. In addition, there was a build up of hydraulic oil in the cofferdam for the stbd side shaft alley.
46 CFR 142.220(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 8 June 2023
Resolution: Bilge was cleaned of all oil.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 May 2023
Resolved
Items recorded as part of the TVR must include the date and time of entry and name of the person making the entry.
Marine inspector observed that the vessel records did not indicate a name associated with the conducted checks.
46 CFR 142.220(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 8 June 2023
Resolution: TVR paperwork was updated to reflect vessel name, captain is signing each document.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 May 2023
Resolved
insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by either the OCMI, or TPO engaged to perform an audit or survey.
Marine inspector observed a hole in the starboard aft, ceiling portion causing a risk for down-flooding.
46 CFR 140.915(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2023
Resolved 8 June 2023
Resolution: Vessel has sealed hole. Weld was intact.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 17 May 2023
Resolved
Multi-outlet adapters (power strips) may not be connected to other adapters (“daisy-chained”), or otherwise used in a manner that could overload the capacity of a receptacle.
Marine inspector observed crew rest area with multiple "daisy-chained" adapters in use.
46 CFR 143.575(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 8 June 2023
Resolution: "Daisy Chain" was removed, additional outlet was installed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 2 June 2022
Resolved
The cognizant OCMI may require additional examinations of the vessel whenever he or she discovers or suspects damage or deterioration to hull plating or structural members that may affect the seaworthiness or fitness for the route or service of a vessel.
Corroded and holed longitudinal stiffners identified by the MI in the forward void were marked during ISE to be cropped and renewed.
46CFR137.300(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2022
Resolved 25 July 2022
Resolution: The company hired a third party welder to crop and renew the damaged stiffners and frames in the forward space. The repairs were completed like and in kind to the original.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 31 May 2022
Resolved
A remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover.
Starboard fuel shut off valve sheared.
46CFR143.260(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2022
Resolved 2 June 2022
Resolution: The remote fuel shut off reach rod was renewed in kind and the valve was operationally tested.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 31 May 2022
Resolved
Each towing vessel must have a fire-detection system which draws power from two sources.
Battery back up did not activate upon loss of power to fire-detection panel.
46CFR142.330(a)(5)
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2022
Resolved 2 June 2022
Resolution: The fire detection system panel emergency battery was renewed and the system operated under two sources of power.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 31 May 2022
Resolved
The cognizant OCMI may require additional examinations of the vessel whenever he or she discovers or suspects damage or deterioration to hull plating or structural members that may affect the seaworthiness or fitness for the route or service of a vessel.
Vessel has multiple areas of significant wastage in voids.
Clean and gas-free all voids to allow for inspection from attending marine inspector.
46CFR137.300(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2022
Resolved 2 June 2022
Resolution: The voids were gas freed and a MI entered all spaces for an ISE. MI found the hull plate and sideshell in satisfactory condition. A new 835 was issued for repairs to the longitudinal stiffners found corroded in the fwd void space.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 May 2022
Resolved
Emergency lighting must be provided for all internal crew working and living areas and must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either (1) automatic, battery -operated with a duration of no less than 2 hours, or (2) non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power. Emergency lighting must be provided for all internal crew working and living areas and must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either (1) automatic, battery -operated with a duration of no less than 2 hours, or (2) non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power.
Missing emergency lightin g strips in the machinery space and bridge/helm space.
46CFR143.410(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2022
Resolved 25 July 2022
Resolution: The company installed emergency lighting strips in the machinery space which identify an egress route as well as in the bridge/helm space.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 31 May 2022
Resolved
The owner or managing operator of a towing vessel must establish procedures to address fall overboard prevention and recovery of persons in the water, including, but not limited to: Personal protective equipment, safely working on the tow, safety while line handling, safely moving between the vessel and a tow, pier, structure, or other vessel and use of retrieval equipment.
Vessel did not have procedures located on board.
46CFR140.425(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2022
Resolved 2 June 2022
Resolution: The operator provided procedures for fall overboard prevention and recovery of persons in the water.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 31 May 2022
Resolved
The owner or managing operator must implement a health and safety plan. The health and safety plan must document compliance with this part (46CFR140.500) and include recordkeeping procedures.
Vessel did not have a Health and Safety Plan.
46CFR140.500(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2022
Resolved 2 June 2022
Resolution: The operator created and implemented a health and safety plan which was found onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 31 May 2022
Resolved
The results of the inspections required by 33CFR164.76 must be documented in the TVR or official logbook.
Vessel had no documentation of inspections of any towing gear on board. Chock on port side seized.
46CFR140.820
Action required: 17 - Rectify deficiencies prior to departure
Due 31 May 2022
Resolved 2 June 2022
Resolution: Towing gear inspections found onboard and logged in the TVR.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 31 May 2022
Resolved
Each life float and rigid buoyant apparatus must be fitted with a lifeline, pendants, a painter, and floating electric water light approved under approval series 161.010.
Life float did not have floating water light.
46CFR141.325(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2022
Resolved 2 June 2022
Resolution: The rigid bouyant apparatus was fitted with all required equipment and markings.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 May 2022
Resolved
Each vessel operating on a lakes, bays and sounds route no more than 3 miles from shore must have 3 day and 3 night visual distress signals.
Vessel missing distress signals.
46CFR141.370
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2022
Resolved 2 June 2022
Resolution: All USCG approved distress signals were found onboard.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 31 May 2022
Resolved
Towing vessels must meet the communications requirements of 33 CFR 164.72 and must be licensed by the FCC.
Vessel did not have FCC certificate.
46CFR140.715
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2022
Resolved 25 July 2022
Resolution: The company contracted a FCC technician who attended the vessel and issued a FCC certificate for the VHF installation.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 May 2022
Resolved
Decks and bulkheads designed to be watertight or weathertight must be maintained in that condition.
Hole cut into bulkhead on deck, starboard side IVO fire axe.
46CFR140.610(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2022
Resolved 2 June 2022
Resolution: The operator cropped and renewed the holed bulkhead using mild steel plate welded in place.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 May 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Multiple dead-end wires,blade fuses, and A/C circuit breakers mounted outside junction boxes and electrical panels located below operating station.
46CFR143.400(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2022
Resolved 2 June 2022
Resolution: Dead end wires were removed and UL listed fuses were found installed for overcurrent protection.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 31 May 2022
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces.
No means of closing all vents into machinery space. The forward natural ventilation duct does not have a means to close in the event of a fire.
46CFR144.605
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2022
Resolved 25 July 2022
Resolution: The company hired a third party welder to weld a closing device on top of the ventilation duct for the engine room. The crew tested the closure in the presence of the attending MI; all sat.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 2 November 2018
Resolved
Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 8 August 2019
Resolution: Confirmed AIS is no longer broadcasting any errors.
Navigation
Issued 14 August 1997
Resolved
PROVIDE CURRENT CHART FOR AREA TRANSITING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 November 1997
Resolved 14 November 1997
Lifesaving
Issued 14 August 1997
Resolved
PROVIDE ONE ADDITIONAL TYPE I PFD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 November 1997
Resolved 14 November 1997
Navigation
Issued 14 August 1997
Resolved
PROVIDE AN 8" BELL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 November 1997
Resolved 14 November 1997
Accommodation/Occupational Safety
Issued 14 August 1997
Resolved
PROVIDE WAIST MANAGEMENT PLAN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 November 1997
Resolved 14 November 1997
Documentation
Issued 14 August 1997
Resolved
PROVIDE FCC RADIO OPERATORS PERMIT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997