MAURY USCG vessel records Sign in
← All vessels

PONTCHARTRAIN

PONTCHARTRAIN is a 1982 offshore supply vessel. The Coast Guard has recorded 34 inspections since 1989, most recently in February 2008, along with 43 deficiencies and 2 casualty investigations between 1998 and 2007.

Records from 1989 to 2008. Most recent: inspection, 12 February 2008.

Built
1982
Last inspected
12 February 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA7705
209469
Flag
UNITED STATES
366846290, 367165720 (licence lapsed)
Maury page id
psix-209469

Inspections, by type

…with no type recorded5
Years with a record 17 calendar years (1989–2008)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it60 - Regulatory (Subpart C or D), Net Ton
89 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD5917MMSI 367165720 · cancelled · compulsorily equipped · granted 9 February 2007, cancelled 16 December 2008
WDA7705MMSI 366846290 · expired · compulsorily equipped · granted 10 April 2002, cancelled 16 June 2012
WCX3407MMSI not assigned · expired · voluntarily equipped · granted 25 March 1997, cancelled 27 May 2007 · licensed under a name not among this hull’s recorded names (not shown)
WST3991MMSI not assigned · expired · compulsorily equipped · granted 22 November 1994, cancelled 27 June 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 34

12 February 2008 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3146325
26 November 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3159176
8 May 2007 Hull Examination · Examination of Repairs · Spot Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2937240
8 February 2007 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2868915
27 April 2006 Re-Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2634787
7 February 2005 Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2288136
3 May 2004 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2056072
30 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1998588
30 May 2003 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1821599
5 February 2002 Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1482593
9 January 2002 Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1476989
2 December 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 806109
11 September 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 111957
15 September 1997 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451217
23 June 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 779227
27 June 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1394590
23 June 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358823
6 April 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1151796
26 July 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1173638
8 July 1994 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429919
20 October 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1156263
13 September 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 836778
20 August 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1156042
22 June 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422253
22 June 1992 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391778
18 September 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1248031
12 August 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1246971
20 June 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1233327
12 June 1990 Deficiency Check · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1226486
3 May 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1211429
12 January 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1227101
15 December 1989 Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1232505
20 June 1989 Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 888771
18 May 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1205938

Deficiency record · 43

Navigation › Piloting/Steering › US Coast Pilot
Issued 12 February 2008 Resolved
Provide updated navigation publications including CG Pilot, Light list, and Tidal/Current tables.
Action required: 705 - Other - as specified
Due 12 March 2008
Resolved 14 February 2008
Communications › Radio Communications › VHF Radiotelephone
Issued 8 February 2007 Resolved
Provide copy of Master's FCC operators license.
Action required: 705 - Other - as specified
Due 22 February 2007
Resolved 12 February 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 February 2007 Resolved
Secure all major appliances ie. washer/dryer, refrigerators.
Action required: 705 - Other - as specified
Due 15 February 2007
Resolved 12 February 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 8 February 2007 Resolved
Remove all combustible material from electrical locker located in the head.
Action required: 705 - Other - as specified
Due 9 February 2007
Resolved 8 February 2007
Construction/Loadline › Structures › Deck Plating
Issued 8 February 2007 Resolved
Repair hole in overhead to main deck in starboard engine room.
Action required: 705 - Other - as specified
Due 15 February 2007
Resolved 12 February 2007
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 8 February 2007 Resolved
Remove and destroy two identified life jackets because of holes.
Action required: 705 - Other - as specified
Due 9 February 2007
Resolved 8 February 2007
Lifesaving › Lifefloat › Float-free Link
Issued 8 February 2007 Resolved
Remount life floats weak link to vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Fire Fighting › Fire Hoses › Condition
Issued 8 February 2007 Resolved
Replace both fire hoses on exterior main deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 8 February 2007 Resolved
Repair exhaust leak on port generator.
Action required: 705 - Other - as specified
Due 15 February 2007
Resolved 12 February 2007
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 8 February 2007 Resolved
Replace exhaust lagging on both generators.
Action required: 705 - Other - as specified
Due 22 February 2007
Resolved 12 February 2007
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 8 February 2007 Resolved
Prove proper operation of generator overspeed trips.
Action required: 705 - Other - as specified
Due 15 February 2007
Resolved 12 February 2007
Engineering › Steering Gear System › Piping
Issued 8 February 2007 Resolved
Repair hydraulic leak of port ram steering system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2007
Fire Fighting › Fire Hydrants › Condition
Issued 8 February 2007 Resolved
Tighten or repack glands on fire station valves.
Action required: 705 - Other - as specified
Due 15 February 2007
Resolved 12 February 2007
Engineering › Steering Gear System › Rudder Bearing
Issued 8 February 2007 Resolved
Repair port rudder from binding during operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 April 2005 Resolved
Install guards on both generator alternators IAW 46 CFR 177.960 no later than 8 Apr 05 to the satisfaction of attending Coast Guard inspector.
Due 8 April 2005
Resolved 7 April 2005
Engineering › Steering Gear System › Rudder Bearing
Issued 3 May 2004 Resolved
Remove standing water from starboard rudder room and make appropriate repairs to both port and starboard rudders to insure water tightness.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2004
Resolution: Water removed and both rudders repacked. Tested sat.
Engineering › Bilge Water Management System › Interface Detector
Issued 3 May 2004 Resolved
Prove proper operation of both port and starboard rudder room high level bilge alarms.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2004
Resolution: Bilge alarms tested sat.
Engineering › Bilge Water Management System › Interface Detector
Issued 3 May 2004 Resolved
Make repairs to or replace hight level bilge alarm in port engine room and prove proper operation.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2004
Resolution: New alarm installed and tested.
Electrical › Lighting (service) › Lighting Fixture
Issued 3 May 2004 Resolved
Provide missing light cover in pilot house head.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2004
Resolution: Cover installed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 3 May 2004 Resolved
Repair or replace emergency lights located on aft port side of deck house, port engine room and main bunk room hallway and prove proper operation.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 5 May 2004
Resolved 5 May 2004
Resolution: Lights installed and tested.
Electrical › Electric Generation Source (emergency)
Issued 3 May 2004 Resolved
Make repairs to emergency power supply for bridge including GQ and prove proper operation. LEGACY COMPONENT DESC: Power Requirement
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2004
Resolution: Power supply repaired and equipment tested on emergency power.
Construction/Loadline › Structures
Issued 3 May 2004 Resolved
Crop and renew wasted and holed section of fwd bulkhead of port side engine room. Wastage is located at the bottom of blkhd from the side shell inboard approx. 34". Clean # 2 void and make available for further inspection after completion of repairs. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2004
Resolution: Insert made and examined and void scleaned and made available for inspection. No further wastage noted.
Construction/Loadline
Issued 8 July 1994 Resolved
PROVIDE CERTIFICATE OF NON DESTRUCTIVE TESTING FOR LEG TO PAD JOINT FOR ALLLEGS.
Condition: Unknown
Due 11 July 1994
Resolved 26 July 1994
Construction/Loadline
Issued 8 July 1994 Resolved
BACK WELD INSERT IWO STARBOARD BOW COMPARTMENT.
Condition: Unknown
Due 11 July 1994
Resolved 26 July 1994
Lifesaving
Issued 8 July 1994 Resolved
INSTALL TILT ALARM IN ACCORDANCE WITH NAVIC 8-91.
Condition: Unknown
Due 8 August 1994
Resolved 26 July 1994
Documentation
Issued 20 June 1991 Resolved
PROVIDE ABS ADMEASUREMENT TO CERTIFICATE.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Documentation
Issued 20 June 1991 Resolved
PROVIDE A COAST GUARD APPROVED OPERATION MANUAL. 46 CFR 109.121
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Documentation
Issued 20 June 1991 Resolved
PROVIDE COAST GUARD STABILITY LETTER. 46 CFR 91.5.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Documentation
Issued 20 June 1991 Resolved
NEW TONNAGE AND OWNERS ADDRESS.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Documentation
Issued 20 June 1991 Resolved
PROVIDE COAST GUARD APPROVED PLANS._x001C_ IF APPROVED ITEMS LISTED ABOVE ARE NOT AVAILABLE, OWNER MUST PROVIDE DOCUMENTATION THAT OF SUBMITAL OF NECESSARY DOCUMENTS TO COMPLY WITH ABOVE REQUIREMENTS PRIOR TO 20JUL91.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Documentation
Issued 20 June 1989 Resolved
PROVIDE APPROVED PLANS AS REQUIRED BY 46 CFR 91.5.
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Documentation
Issued 20 June 1989 Resolved
PROVIDE STABILITY TEST AS REQUIRED BY 46 CFR 91.5.
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Engineering
Issued 20 June 1989 Resolved
PROVIDE TAILSHAFT EXAM AS REQUIRED BY 46 CFR 61.10-15.
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Unknown
Issued 20 June 1989 Resolved
SUBMIT OPERATING MANUAL FOR APPROVAL MEETING THE REQUIREMENTS OF 46 CFR 109.121.
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Deck/Cargo
Issued 20 June 1989 Resolved
CONDUCT TEST OF INSTALLED CRANES IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Lifesaving
Issued 20 June 1989 Resolved
INSTALL A SUITABLE EMERGENCY MEANS OF ESCAPE WHILE IN THE ELEVATED POSITION.
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Electrical
Issued 20 June 1989 Resolved
REWIRE COMPLETE VESSEL WHERE WIRED WITH HOUSEHOLD SOLID CORE WIRE. WIRING TO BE DONE AS PER 46 CFR SUBCHAPTER "J" WITH APPROVED WIRING.
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Documentation
Issued 20 June 1989 Resolved
PROVIDE NAUTICAL PUBLICATIONS AS REQUIRED BY 46 CFR 97.05-5.
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Lifesaving
Issued 20 June 1989 Resolved
PROVIDE APPROVED RESCUE BOAT AS REQUIRED BY 46 CFR 94.10-5.
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Lifesaving
Issued 20 June 1989 Resolved
PROVIDE EPIRB AS REQUIRED BY 46 CFR 94.60-1.
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Electrical
Issued 20 June 1989 Resolved
PROVIDE COVERS FOR ALL EXPOSED 12 VOLT CONNECTION BOXES.
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Lifesaving
Issued 20 June 1989 Resolved
PROVIDE ONE ADDITIONAL LIFE RING WITH LINE AND WATER LIGHT AS REQUIRED BY 46 CFR 94.43-10.
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989
Electrical
Issued 20 June 1989 Resolved
REPLACE RENEWABLE TYPE FUSE IN S/S GENERATOR SWITCHING BOX.
Condition: Unknown
Due 20 June 1989
Resolved 20 June 1989

Casualty record · 2

11 September 1998Major Marine Casualty · role: Involved in a Marine Casualty · activity 111957
26 November 2007Routine · role: Involved in a Marine Casualty · 1 injured · activity 3159176
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record