Records from 1992 to 2005. Most recent: inspection, 19 August 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
19 August 2005
Administrative Inspection
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2468219
3 September 2004
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2184257
13 August 2004
Periodic Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2163327
19 August 2003
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1880592
23 July 2003
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1846858
16 August 2002
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1657792
28 March 2002
Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1493917
16 May 2001
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1387080
8 June 2000
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1458770
10 August 1999
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 776496
8 July 1999
Re-Inspection · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1469913
18 May 1998
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1441384
18 December 1997
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 781513
25 June 1997
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1364233
6 March 1997
Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1377981
20 May 1996
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1385733
23 May 1995
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1355323
28 June 1994
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1412664
23 June 1993
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1455077
19 June 1992
Initial Certification · Hull Examination · Plan Review "T" Boat
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 959263
Navigation › Piloting/Steering › Coast Guard Light List
Issued 13 August 2004
Resolved
Procure latest nav rules and light list
Due 13 September 2004
Resolved 24 August 2004
Resolution: Sighted this date.
Lifesaving › Hand Flares › Expired
Issued 13 August 2004
Resolved
Procure up to date flares and smokes
Due 1 September 2004
Resolved 13 September 2004
Resolution: Sighted up-to-date flares.
Construction/Loadline › Structures › Deck Plating
Issued 13 August 2004
Resolved
Actually, this is for overhead of sailboat galley.) Crop & renew fiberglass in galley overhead from port chain plate aft to port stern 2nd bulkhead and forward to lazarette bulkhead. First area is approx. 24 square feet, 2nd is approximately 6 square feet. Complete to satisfaction of attending Marine Inspector prior to Sep 13, 2004.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2004
Lifesaving › Buoyant Apparatus › Serviceable
Issued 13 August 2004
Resolved
Vessel is limited to cold water route pending completion of repairs to life float IAW 46 CFR 180.200(a)(2).
Due 13 September 2004
Resolved 13 September 2004
Resolution: Sighted completed repair work this date.
Engineering › Bilge Water Management System
Issued 23 July 2003
Resolved
Need a bilge alarm intalled on bilge pump under sink. LEGACY COMPONENT DESC: Interface Detector
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 August 2003
Resolved 18 August 2003
Resolution: Visual and audio alarm installed
Accommodation/Occupational Safety › Medical/First Aid
Issued 23 July 2003
Resolved
Eye wash expired LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2003
Resolved 18 August 2003
Lifesaving
Issued 16 May 2001
Resolved
Renew lifering grablines
Condition: Unknown
Due 3 August 2001
Resolved 3 August 2001
Documentation
Issued 16 May 2001
Resolved
Procure Great Lakes Agreement
Condition: Unknown
Due 3 August 2001
Resolved 3 August 2001
Engineering
Issued 16 May 2001
Resolved
Properly mark fuel oil shut-off valves
Condition: Unknown
Due 3 August 2001
Resolved 3 August 2001
Navigation
Issued 16 May 2001
Resolved
Vessel is limited to daylight operation pending proof of proper operation of illuminated compass
Condition: Unknown
Due 16 June 2001
Resolved 25 May 2001
Lifesaving
Issued 16 May 2001
Resolved
Procure Coast Pilot
Condition: Unknown
Due 3 August 2001
Resolved 3 August 2001
Construction/Loadline
Issued 16 May 2001
Resolved
Prove proper operation of bilge high level alarms
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Electrical
Issued 8 June 2000
Resolved
Replace wire connectors, in way of fixed firefighting wiring located in theengine compartment, w/approved type in accordance with 46 CFR 183.340 and to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 25 June 2000
Resolved 27 June 2000
Documentation
Issued 8 June 2000
Resolved
Provide proof of FCC Radio Great Lakes Agreement to the satisfaction of theattending marine inspector.
Condition: Unknown
Due 25 June 2000
Resolved 27 June 2000
Accommodation/Occupational Safety
Issued 8 June 2000
Resolved
Finish installing doger lines on vessel life lines to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 25 June 2000
Resolved 27 June 2000
Lifesaving
Issued 8 June 2000
Resolved
Provide and install CG approved waterlight w/18ft lanyard for life float tothe satisfaction of the attending marine inspector and prior to the sailingof vessel during night time.
Condition: Unknown
Due 25 June 2000
Resolved 27 June 2000
Fire Fighting
Issued 8 June 2000
Resolved
Provide and install break glass enclosure for fixed firefighting emergency pull handle to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 25 June 2000
Resolved 27 June 2000
Construction/Loadline
Issued 8 June 2000
Resolved
Provide and install auto bilge pump indicator light at operating station tothe satisfaction of the attending marine inspector.
Condition: Unknown
Due 25 June 2000
Resolved 27 June 2000
Fire Fighting
Issued 8 July 1999
Resolved
Provide & properly install C.G. approved fixed fire fighting system for en-gine compartment w/associated automatic shut downs & visual/audible alarms prior to the carriage of passengers & to the satisfaction of the attending_x001C_marine inspector.
Condition: Unknown
Due 15 August 1999
Resolved 13 July 1999
Fire Fighting
Issued 8 July 1999
Resolved
Provide C.G. approved fire & smoke detection system for engine compartment and properly install the same prior to the carriage of passengers & to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 15 August 1999
Resolved 13 July 1999
Lifesaving
Issued 8 July 1999
Resolved
Provide proof of C.G. approved weak link for vessel's bouyant apparatus to the satisfaction of the attending marine inspector. Vessel restricted to no more than 3 nautical miles from shore until proper weak link provided.
Condition: Unknown
Due 15 August 1999
Resolved 15 July 1999
Navigation
Issued 8 July 1999
Resolved
Provide current & updated navigation publications in accordance with 46 CFR184.420 to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 15 August 1999
Resolved 13 July 1999
Documentation
Issued 8 July 1999
Resolved
Provide current bridge & training log books w/documentation of all employeetraining and drills for vessel prior to the carriage of passenger & to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 15 August 1999
Resolved 13 July 1999
Fire Fighting
Issued 8 July 1999
Resolved
Provide both fixed and portable fire extinguisher servicing certificates prior to the carriage of passengers & to the satisfaction of the attending_x001C_marine inspector.
Condition: Unknown
Due 15 August 1999
Resolved 13 July 1999
Documentation
Issued 8 July 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 15 August 1999
Resolved 13 July 1999
Lifesaving
Issued 8 July 1999
Resolved
Vessel restricted to within 3 nautical miles from shore until provided witha 406 MHz EPIRB and to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 15 August 1999
Resolved 15 July 1999
Fire Fighting
Issued 8 July 1999
Resolved
Properly label three 2-1/2 gallon fire buckets with "fire bucket" & name ofvessel to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 15 August 1999
Resolved 13 July 1999
Documentation
Issued 8 July 1999
Resolved
Provide current FCC Great Lakes Agreement for vessel to the satisfaction ofthe attending marine inspector.
Condition: Unknown
Due 8 July 1999
Resolved 8 July 1999
Lifesaving
Issued 18 May 1998
Resolved
PROVIDE 03 ADDITIONAL DISTRESS SMOKE SIGNALS
Condition: Unknown
Due 18 June 1998
Resolved 27 May 1998
Lifesaving
Issued 18 May 1998
Resolved
PERFORM SATISFACTORY DRILLS UNDER SAIL
Condition: Unknown
Due 18 June 1998
Resolved 6 August 1998
Lifesaving
Issued 23 May 1995
Resolved
Replace expired 06 hand held orange smoke distress signals with current signals in accordance with 46 CFR 180.35-5.
Condition: Unknown
Due 24 May 1995
Resolved 3 July 1995
Construction/Loadline
Issued 23 June 1993
Resolved
Repair fracture at port side of cockpit in way of connection of cockpit to deck.
Condition: Unknown
Due 5 October 1993
Resolved 5 October 1993
Lifesaving
Issued 23 June 1993
Resolved
Repair cracks and gouges in life float.
Condition: Unknown
Due 5 October 1993
Resolved 5 October 1993
Engineering
Issued 23 June 1993
Resolved
Repair fracture at clew end of main boom in way of sail track end.
Condition: Unknown
Due 5 October 1993
Resolved 5 October 1993