Records from 2002 to 2004. Most recent: inspection, 26 August 2004.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 26 August 2004
Resolved
The ship's 4 main propulsion engines are not operable at rated capacity.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2004
Resolution: Engines overhauled and tested to operate at rated capacity.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 26 August 2004
Resolved
The outboard starboard propulsion water jet is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2004
Resolution: Outboard starboard propulsion jet tested and working properly.
Fire Fighting › Fire Pumps › Arrangement
Issued 26 August 2004
Resolved
Both ship's fire pumps are inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2004
Resolution: New fire pumps installed and tested properly.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 26 August 2004
Resolved
The Safety Management Certificate identifies the vessel as a High Speed Passenger Craft. The Document of Compliance does not list High Speed Passenger Craft. The vessel holds SOLAS certificates for cargo ships. Clarify the ship's type and provide proof that the ship's operators are authorized to manage the ship.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2004
Resolution: Both SMC and DOC now indentify vessel as other ship.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 26 August 2004
Resolved
Main water circulating pump for ship's air conditioning units is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 August 2004
Resolution: Installed new water pump.
Engineering › Bilge Water Management System › Pump
Issued 26 August 2004
Resolved
Starboard bilge pump is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2004
Resolved 15 December 2004
Resolution: New bilge pump installed and tested.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 26 August 2004
Resolved
Excessive oil and water in the bilges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2004
Resolved 15 December 2004
Lifesaving › Hand Flares › Expired
Issued 26 August 2004
Resolved
6 parachute flares & both SARTs are expired.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 15 December 2004
Resolution: New flares and SARTs on vessel.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 26 August 2004
Resolved
The vessel has charts but not required publications for this voyage.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 15 December 2004
Resolution: Required publications acquired and were onboard vessel.