Records from 1993 to 2025. Most recent: inspection, 26 February 2025.
Documentation record
Registered dimensions (L × B × D)60.0 ft × 22.0 ft × 8.8 ft
Registered tonnagegross 81 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJOHN RICHARD · PORT ARTHUR, TX, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBURLINGTON, IA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 3 August 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Simplified, Gross Ton
65 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
26 February 2025
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8085145
8 March 2023
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7647630
17 October 2022
Initial Certification
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7579123
18 February 2021
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7142404
9 May 2017
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6148745
12 October 2016
Industry Initiated Exam
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6022027
9 February 2016
Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5814295
1 February 2016
DAPI Audit · Industry Initiated Exam
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5809571
26 May 2011
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4028674
4 May 2011
DAPI Audit
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4030859
23 February 2011
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3955973
27 October 2009
DAPI Audit
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3623745
10 July 2009
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3537341
5 June 2007
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 2952758
5 September 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2769530
29 March 2004
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2054703
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1981628
19 July 2000
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 282505
22 April 1999
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 428042
16 September 1997
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 408380
29 July 1997
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 407163
1 April 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 662661
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 October 2022
Resolved
Vessel is required to undergo an external audit within 6 months of date of inspection. Provide proof of external audit completion.
Action required: 705 - Other - as specified
Due 26 April 2023
Resolved 8 March 2023
Electrical
Issued 19 July 2000
Resolved
All lighting fixtures must have the proper protective coverings.
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Electrical
Issued 19 July 2000
Resolved
All loose, exposed, or dead end wiring must be removed, covered, or replaced.
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Accommodation/Occupational Safety
Issued 19 July 2000
Resolved
All broken window coverings must be removed or replaced.
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Construction/Loadline › Hull › Weld
Issued 22 April 1999
Resolved
Bilge pumps located under shaft packing must not be installed until seperation of oil and fresh water can be fabricated.
Condition: Unknown
Due 22 May 1999
Resolved 22 April 1999
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 22 April 1999
Resolved
Gally window is broken and must be replaced.
Condition: Unknown
Due 22 May 1999
Resolved 22 April 1999
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 April 1999
Resolved
Aft amber towing light is extinguished.
Condition: Unknown
Due 22 May 1999
Resolved 22 April 1999
Navigation
Issued 29 July 1997
Resolved
VESSEL DIDN'T HAVE NAVIGATION CHARTS ONBOARD.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Accommodation/Occupational Safety
Issued 29 July 1997
Resolved
NEED TO MAKE MSD OPERATIONAL OR REMOVE TOILED FACILITIES.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997