Records from 2012 to 2026. Most recent: inspection, 9 March 2026.
Inspection history · 26
9 March 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8323175
11 September 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8194445
8 May 2025
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8131154
8 May 2025
Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8131776
28 October 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8028041
26 September 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7995857
6 May 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7907614
18 April 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7897639
13 October 2023
Administrative Inspection · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7806172
16 May 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7689854
28 October 2022
Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7670331
23 September 2022
Annual Inspection · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7558294
29 June 2021
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7231797
12 May 2021
Deficiency Check · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7195226
12 November 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7093907
8 May 2020
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6950181
26 September 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6821413
17 August 2019
Damage Survey · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6790131
18 June 2019
Damage Survey · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6716749
13 March 2019
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6641653
22 October 2018
Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6565979
18 May 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6417534
23 October 2017
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6293147
18 May 2017
Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6149506
14 September 2016
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6001590
20 June 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5914546
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 September 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must: (3) Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Automatic shutdown not functioning.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2025
Resolved 16 September 2025
Resolution: repaired and functional
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 September 2025
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. EPIRB battery expired recently.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2025
Resolved 22 September 2025
Resolution: battery replaced
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 May 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. The vessel is to remain docked until such time as it is cleared by CGMI pending shipwright inspection. Vessel will be allowed to be towed to the nearest repair facility at that time. No passengers are to be permitted on board until approved by the CGMI.
Action required: 705 - Other - as specified
Resolved 28 May 2025
Resolution: Repairs to the vessels hull were satisfactory to the attending CGMIs both at the pier and during power trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 May 2025
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The vessel must prove proper mechanical operation of the main propulsion's reduction gear to the satisfaction of the CGMI prior to the carriage of passengers or movement under vessel's own power.
Action required: 705 - Other - as specified
Resolved 28 May 2025
Resolution: Vessel replaced the gearbox in kind and conducted successful power trials in the presence of CGMIs.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 May 2025
Resolved
Vessel put back in the water after extensive winter
long drydock. After going back in water, vessel has
several leaks. Owner requested to transit back to
Boston. Drydock credit will not be issued until water
ingress has stopped. Vessel may not carry
passengers until leaks have stopped and Boston
inspectors attend vessel to approve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2025
Resolution: Boston inspectors inspected for leaks between the aft cabin and the shaft log once vessel completed emergency dry dock in AOR. No significant leaks or weaping was found throughout.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 September 2024
Resolved
A number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided, or such greater number as necessary to provide a life jacket for each person being carried that is smaller than the lower size limit of the adult life jackets provided to meet this section. 03 of the 05 child sized life jackets are split in several areas and must be replaced or repaired in accordance with the manufacturer.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 4 October 2024
Resolution: replaced in kind
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 September 2024
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all engines that draw intake air from within the protected space and have the following equipment at the operating station: A light to indicate discharge; An audible alarm that sounds upon discharge; and a means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. Crew is unable to demonstrate functionality of the engine shutdown, alarms, or reset device (overide).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 4 October 2024
Resolution: MI witnessed satisfactory tests
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 September 2024
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Life jacket bags are not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 4 October 2024
Resolution: marked IAW subchapter T
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 October 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Fuel shutoff valve linkage broke when tested remotely, rendering it inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2024
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 October 2023
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down and have all engines that draw intake air from within the protected space and have a light and audible alarm at the operating station. Master was unfamiliar with procedures to test the pre-engineered system shutdown,override, and alarm functions.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 October 2023
Resolved
Each life jacket must be marked with Type I retroreflective material. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16. Several life jackets had no markings or reflective material, and several have deteriorated/non-functioning reflective material.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2024
Resolution: Life jackets have proper markings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 October 2023
Resolved
A vessel of more than 26 feet in length, but not more than 65 feet, must carry a minimum of one life buoy of not less than 24 inches in diameter. Ring life buoy is splitting at the seems on the outer rim. Ring life buoy must be repaired in accordance with manufacturers specifications or replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2024
Resolution: Ring life buoy replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 September 2022
Resolved
Vessel must comply with the structural design requirements of Lloyd's Yachts and Small Craft for wooden vessels. Observed ingress of approx. 5 gal/hr sea water in way of lower end of horn timber above shaft log. Determine cause of hull damageand and repair as original.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 October 2022
Resolved 16 May 2023
Resolution: Hull was repaired
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 September 2022
Resolved
Bowsprits and standing rigging on a sailin vessel must be suitable for intended service. Anchor point for bobstay on underside of forestay collar on bowsprit elongated. Bolt holding forestay turnbuckle to anchor point appeared too small for hole.
Bobstay secured with satisfactory come-along arrangement, authorized to continue ops until next drydocking.
46 CFR 176.300
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 October 2022
Resolved 16 May 2023
Resolution: Repaired as original.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 September 2022
Resolved
Cooking systems using LPG must meet design, installation and testing requirements of ABYC Standard A-1, Marine Liquefied Petroleum Gas (LPG) Systems. Found non-compliant LPG tank installation fitted to galley stove. Permanently remove LPG tank installation or bring into compliance with ABYC A-1.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 October 2022
Resolved 20 April 2023
Resolution: LPG tank removed.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 23 September 2022
Resolved
A vessel must be fitted with ground tackle necessary for the vessel to be safely anchored. Up/down switch on anchor windlass inoperative. Repair and prove proper operation of windlass.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 October 2022
Resolved 20 April 2023
Resolution: Witnessed satisfactory operation of the anchor windlass.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 September 2019
Resolved
Provide purchase and installation dates for all rigging key components listed in Appendix (1) to Enclosure (1) of NVIC 02-16.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 May 2020
Resolved 29 June 2021
Resolution: Provided requiered purchase and installation dates for key componendts of the standing and running rigging.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 September 2019
Resolved
Make available a Rigging Preventive Maintenance Program that provides a level of detail commensurate with Appendix (2) to Enclosure (1) of NVIC 02-16, or propose a mutually acceptable third party to survey the rigging and provide a report with the level of detail commensurate with either Appendix (3) or (4) to Enclosure (1) of NVIC 02-16.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 May 2020
Resolved 29 June 2021
Resolution: Provided rigging preventive maintenance program, in compliance with NVIC 02-16
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 September 2019
Resolved
A vessel with a pre-engineered fixed gas fire extinguisher system must have installed at the operating station the following: A light to indicate discharge and an audio alarm to indicate discharge. Provide light and audible alarm at operating station to indicate fixed firefighting system discharge. Provide a means to override system to start the engine if needed .
Action required: 60 - Rectify deficiencies prior to movement
Due 1 May 2020
Resolved 8 May 2020
Resolution: Relocated alarm to operating station, tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 September 2019
Resolved
Vessel is required to have an auxiliary means of steering that is of adequate strength and be capable of moving from 15 degrees port to 15 degrees stbd in 60 seconds. Demonstrate ability to comply with requirement.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 May 2020
Resolved 8 May 2020
Resolution: Provided tiller for emergency steering. Tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 September 2019
Resolved
Vessel required to have approved life preservers for each person on board. Vessel is short 3 approved Type II life preservers for adult. Provide sufficient life preservers for all persons onboard. Max number of persons onboard is 39.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 May 2020
Resolved 8 May 2020
Resolution: Verified suficient number of life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 September 2019
Resolved
Vessel requires one ring buoy with line and light. Vessel ring buoy is not serviceable, light not installed properly and line not provided. Provide ring buoy and attachments as required and in compliance with 46 CFR 180.70.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 May 2020
Resolved 8 May 2020
Resolution: Verified new ring buoy with new light and line. tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 September 2019
Resolved
Vessel has EPIRB on board with expired battery and expired hydrostatic release. Provide battery and hydrostatic release that are approved, and not expired
Action required: 60 - Rectify deficiencies prior to movement
Due 1 May 2020
Resolved 8 May 2020
Resolution: Provided new EPIRB, new battery, new hydrostatic release and registration. Tested Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 September 2019
Resolved
Port side fuel tank milling bonding strap on flexible hose to prevent static electricity buildup. Provide bonding strap.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 May 2020
Resolved 8 May 2020
Resolution: Verified installation of port fuel tank fill bonding strap.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 26 September 2019
Resolved
Master of vessel shall conduct sufficient drills and give sufficient instruction to make sure that all crew members are familiar with their duties during all emergencies. Crew members need to demonstrate knowledge of actions required to deploy anchor. Demonstrate knowledge of the fixed firefighting system and how to operate it. Demonstrate knowledge of where the emergency fuel shutoff are and how and when to operate them. Demonstrate knowledge of location of seacocks penetrating the hull below the waterline. Demonstrate ability to recover an unconscious person from the water.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 May 2020
Resolved 8 May 2020
Resolution: Witnessed walkthrough of fire and man overboard with sat results.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 September 2019
Resolved
At each subsequent inspection for certification the marine inspector shall examine all accessible parts of the exterior and interior of the hull.
A temporary repair behind the fwd, port, main mast chainplate were made to fill the fastener holes with epoxy while new chainplate is being fabricated.
Submit repair proposal for permanent repairs to port planking, frame and chainplate fasteners where the temporary repair was made behind chainplate area.
Action required: 705 - Other - as specified
Due 30 April 2020
Resolved 15 June 2021
Resolution: Port main mast chain plate temp repair replaced with permanent repair approved by OCMI. Inspected SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 September 2019
Resolved
No major repairs or alterations affecting the safety of the vessel with regard to the hull shall be made without the knowledge and approval of the [name withheld] alterations shall be approved by the OCMI, before work is started.
Permanently repair wood planking, frame, chainplate and chainplate fasteners on port side, after proposal for repair is approved by the attending Marine Inspector.
**RESTRICTED FROM USING MAIN MAST, DO NOT YOU USE MAIN SAIL.
46 CFR 176.20-1
Action required: 705 - Other - as specified
Due 30 April 2020
Resolved 15 June 2021
Resolution: Port main mast chain plate permanent repairs completed as approved by OCMI. Inspected sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 September 2019
Resolved
At each subsequent inspection for certification the marine inspector shall examine all accessible parts of the exterior and interior of the hull.
Aft, port planking wood graving insert approximately 3"x 8"x 1" was installed 1' ft above the waterline, below the rub rail as temporary repair until vessel is haul out of the water in October.
Submit repair proposal for permanent repairs to port, aft side of vessel planking where temporary wood graving repair was made.46 CFR 176.25-5
Action required: 705 - Other - as specified
Due 30 April 2020
Resolved 8 May 2020
Resolution: Submitted proposal. Completed repair after approval of proposal. Inspected sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 August 2019
Resolved
At each subsequent inspection for certification the marine inspector shall examine all accessible parts of the exterior and interior of the hull. Discovered an area of rotten wood approximately 2 inches in height, 6 inches in length and 1 inch deep on the port, aft side of the vessel 1 foot above the waterline. Submit repair proposal no later than 23Aug19 for repairs to renew areas of rot to good sound wood.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 August 2019
Resolved 21 August 2019
Resolution: Proposed a diamond-shaped insert as a temporary repair for damage to port side aft plank.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 August 2019
Resolved
No major repairs or alterations affecting the safety of the vessel with regard to the hull shall be made without the knowledge and approval of the [name withheld] alterations shall be approved by the OCMI, before work is started. Repair rotten wood on port, aft plank, after proposal for repair is approved by the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 August 2019
Resolution: Proposed a diamond-shaped insert as a temporary repair for damage to port side aft plank.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 August 2019
Resolved
At each subsequent inspection the inspector shall examine all items in the ship's outfit. Portside mainsail shroud damaged and chainplate. Submit repair proposal to the satisfaction of the attending marine inspector. Restricted, do not use main sail.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 September 2019
Resolution: Temporary repair approved
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 August 2019
Resolved
No major repairs or alterations affecting the safety of the vessel with regard to the hull shall be made without the knowledge and approval of the [name withheld] alterations shall be approved by the OCMI, before work is started. Permanently repair wood planking on port, aft plank, after proposal for repair is approved by the attending Marine Inspector.46 CFR 176.20-1
Action required: 705 - Other - as specified
Due 30 April 2020
Resolved 8 May 2020
Resolution: Submitted proposal for repairs.
Engineering › Feedwater/Condensate Water System › Valve
Issued 18 May 2018
Resolved
Lazarette salt water overboard valve handle was found to be wasted, issued requirement to renew.
Action required: 705 - Other - as specified
Due 29 June 2018
Resolved 25 June 2018
Resolution: Valve handle was replaced in-kind.
Engineering › Fuel Oil Service System › Valve
Issued 18 May 2018
Resolved
Generator fuel shut-off valve was found to be missing a nut, issued requirement to provide nut.
Action required: 705 - Other - as specified
Due 29 June 2018
Resolved 25 June 2018
Resolution: Valve and handle were provided with a securing nut.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 18 May 2018
Resolved
Engine throttle cable was found to have nylon line holding it in place, issued requirement to make permanent repairs.
Action required: 705 - Other - as specified
Due 29 June 2018
Resolved 25 June 2018
Resolution: Throttle cable was secured in place using stainless steel lock-wire.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 May 2018
Resolved
Starboard side navigation light was blue in color, issued requirement to renew with green.
Action required: 705 - Other - as specified
Due 29 June 2018
Resolved 25 June 2018
Resolution: LED light bulb was removed and replaced with incandescent making starboard running light green.
Stability › Watertight Integrity › General
Issued 18 May 2017
Resolved
Vessel arrived at the Port of Palm Beach, FL with flooding reported by the crew. The vessel was bound for Boston from St Thomas, USVI. A CG-835 was issued to affect repairs prior to departure. Wording for CG-835 too lengthy for this entry, document attached to this activity.
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 19 June 2017
Electrical › Electric Generation Source (service) › Generator
Issued 18 October 2016
Resolved
Vessel is prohibited from running the installed generator under the provisions of the COI as an inspected vessel until plans have been submitted, approved and verified by attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2017
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 18 October 2016
Resolved
Vessel must install remote shutoff for generator fule valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 June 2016
Resolved
Stanchions found cracked. Repair/replace in kind.
Due 5 July 2016
Resolved 5 July 2016
Resolution: Cracked stanchions have been replaced in kind. SAT.
Construction/Loadline › Penetrations › Bottom Plug
Issued 20 June 2016
Resolved
Dead ended through hull valve found with no cap. Provide cap to ensure no water ingress if the valve is opened.
Due 5 July 2016
Resolved 5 July 2016
Resolution: Through hull valve has been capped. SAT.