Records from 2017 to 2025. Most recent: inspection, 3 October 2025.
Inspection history · 23
3 October 2025
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8245896
16 July 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8191168
11 June 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8157038
22 May 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8148132
9 December 2024
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8045310
30 July 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7969853
28 March 2024
In-Service Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7886604
16 August 2023
Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7769659
5 June 2023
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7703411
9 May 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7686980
11 May 2022
Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7448215
28 March 2022
Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7424748
4 January 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7375496
10 September 2021
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7311541
10 June 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7218913
27 May 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7212302
5 August 2020
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7036445
3 October 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6822446
1 July 2019
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6731785
30 April 2019
Administrative Inspection · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6673444
20 June 2018
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6442294
19 April 2017
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6129237
4 April 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6117435
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 2 January 2026
Resolved
Vessels described by 46 CFR 175.110(d) must comply with the regulations in § 177.500. Vessel has not replaced secondary means of escape in order to comply with 46 CFR 177.500(j). Passengers cannot utilize overnight accommodations. 46 CFR 177.115(c)
Action required: 705 - Other - as specified
Resolved 13 April 2026
Resolution: Removed overnight accommodations from COI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 October 2025
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel did not conduct an annual inspection during the required time frame. Vessel must conduct an annual inspection.
46 CFR 176.500(b)(1)
701c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2025
Resolution: Completed annual inspection
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 June 2025
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel's drydock examination is overdue. Complete credit drydock examination prior to the carriage of passengers.
46 CFR 176.600
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Completed Credit Dry Dock.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 19 December 2024
Resolved
All general areas accessible to passengers to have no less than 2 independent avenues of escape that are-
(I) constructed and arranged to allow for free and unobstructed egress from such areas;
(II) located so that if one avenue of escape is not available, another avenue of escape is available; and
(III) not located directly above, or dependent on, a berth;
PLAN REQUIRED.—Not later than April 1, 2024,
an operator of an overnight fishing charter not in compliance with such section 3306(n)(3)(A)(v) shall submit to the Commandant a plan for complying with such requirements. Vessel failed to submit required plans.
EXTENSION.—On and after April 1, 2024, with
respect to an operator of an overnight fishing charter which has submitted a plan for compliance in accordance
with subparagraph (B), a captain of the port may extend
vessels described by 46 CFR 175.110(d) must comply with the regulations in § 177.500 not later than January 1, 2026.
NOTICE TO PASSENGERS.—Beginning on the date on
which the requirements under section 3306(n)(3)(A)(v) of title 46, United States Code, take effect, the owner or operator of a vessel for which an extension is granted under paragraph (1)(C) shall provide on the website of such owner or operator of the vessel, the vessel, and each ticket for a passenger a prominently displayed notice that the vessel is exempt from meeting the Coast Guard safety compliance standards concerning egress as described in such section. Notice not on website.
46 USC 3306(n)(3)(A)(v)
NDA FY-24 HR 2670
SEC 3531(b)
Action required: 705 - Other - as specified
Resolved 13 April 2026
Resolution: Removed overnight accommodations on COI
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 19 December 2024
Resolved
Vessels described by 46 CFR 175.110(d) must comply with the regulations in § 177.500.
A ladder leading to a deck scuttle may not be used as a means of escape. The secondary means of escape is a vertical ladder.
46 CFR 177.500(j)
Action required: 705 - Other - as specified
Resolved 13 April 2026
Resolution: Removed overnight accommodations from COI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 July 2024
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, each hose must: (1) Be lined commercial fire hose that conforms to UL 19 (incorporated by reference, see 46 CFR 175.600) or hose that is listed and labeled by an independent laboratory recognized by the Commandant as being equivalent in performance. During fire pump and hose testing, observed multiple holes on vessel’s forward hose. Replace with new.
46 CFR 181.320(b)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2024
Resolution: Owner replaced punctured fire hose with new one.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 June 2023
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. MI'S DISCOVERED LEAK ON WET EXHAUST SYSTEM ON PORT ENGINE. IDENTIFY CAUSE OF LEAK AND MAKE REPAIRS.
46 cfr 176.804
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2023
Resolved 31 July 2024
Resolution: No visible leaks on exhaust system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 June 2023
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. MI'S DISCOVERED A TEMPORARY REPAIR ON THE PORT WET EXHAUST SYSTEM. PROVIDE DOCUMENTATION ON WHAT PROCEDURES WERE FOLLOWED DURING REPAIR AND WHAT MATERIALS/EPOXY WERE USED.
46 cfr 176.700
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2023
Resolved 31 July 2024
Resolution: No visible leaks on exhast system.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 May 2022
Resolved
Entrance to Engine room did not have proper labeling for a space protected by a Carbon Dioxide system. Put required labeling at entrance to Engine room, to the satisfaction of the attending Marine Inspector. 46CFR185.612(g)
Action required: 10 - Deficiency Rectified
Resolved 12 May 2022
Resolution: Proper labeling was put in place at entrance of engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 May 2022
Resolved
Fuel shutoff valves were not properly labeled. Properly label to the satisfaction of the attending Marine Inspector. 46CFR185.608
Action required: 10 - Deficiency Rectified
Resolved 12 May 2022
Resolution: Label was applied for all fuel shutoff valves.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 May 2022
Resolved
Vessel was issued 30 day extension to meet required plan submittal for watch monitoring device(s) per new Fire Safety of Small Passenger Vessels Federal Register/Vol 86, No. 245, dated December 27, 2021. Vessel failed to submit required plans, therefore vessel is not authorized to use overnight accommodations for passengers until plans are received and approved by local OCMI.
Action required: 705 - Other - as specified
Due 4 May 2022
Resolved 5 June 2023
Resolution: IFR plans submitted. Confirmed during renewal inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 March 2022
Resolved
Vessel missed required due date for plan submittal of monitoring device required by 3/28/2022. Granted 30 day extension for plan submittal. Failure to meet deadline will result in another 835 issued for no passenger overnight accommodations. 46 CFR 185.410(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2022
Resolved 5 June 2023
Resolution: Plans for monitoring device submitted. confirmed during renewal inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 January 2022
Resolved
Bow thruster twist on wire nuts shall be secured to prevent loosening. Those connectors and capacitors shall be in an enclosure. Vessel cannot carry passengers/cargo until this deficiency is corrected and cleared by the USCG.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2022
Resolved 11 May 2022
Resolution: Repairs completed to bow thruster, verified by the attending MI
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 June 2021
Resolved
Forward overnight escape hatch requires marking on outside in 2" letters. "EMERGENCY EXIT KEEP CLEAR".
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2021
Resolved 10 September 2021
Resolution: Attended vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2021
Resolved
High water alarm junction in bow thruster space requires mounting. High water alarm box in lazarette is broken and calble is not watertight. Replace box.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2021
Resolved 10 September 2021
Resolution: Attended vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 June 2021
Resolved
Life ring buoy battery is expired. Replace with battery specified by manufacturer.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2021
Resolved 29 June 2021
Resolution: Received photo's of battery.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 June 2021
Resolved
Fuel vent flame screen requires replacement (under sink). Clean spilled fuel under sink.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2021
Resolved 10 September 2021
Resolution: Attended vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 June 2021
Resolved
Bow thruster twist on wire nuts shall be secured to prevent loosening. Those connecttions and capactors shall be in an enclosure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2021
Resolved 11 May 2022
Resolution: Repairs completed to bow thruster, verified by the attending MI
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 August 2020
Resolved
Pressure gauge on fire pump discharge side not operable. Replace fire pump gauge.
46 CFR 181.300(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 10 June 2021
Resolution: Witnessed operation of gauge during 2021 annual.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 August 2020
Resolved
Vessel did not have adequate number of flares.
46 CFR 180.68(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 4 September 2020
Resolution: pictures of replaced flares sent to MI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 August 2020
Resolved
Vessel did not have appropriate spanner wrenchs for fire stations.
46 CFR 181.310(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2020
Resolved 27 May 2021
Resolution: Visually inspected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 August 2020
Resolved
Life jacket stowage location not labeled properly. Ensure stowage locatio is labeled IAW CFR.
46 CFR 185.604(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2020
Resolved 27 May 2021
Resolution: Visually inspected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 5 August 2020
Resolved
Deck hatch cover not secured to the vessel.
46 CFR 179.360(b)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2020
Resolved 27 May 2021
Resolution: Visually inspected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 August 2020
Resolved
Wiring located in the #4 fire station closet must be in an enclosure. Ensure all wiring is contained within an enclosure.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2020
Resolved 10 June 2021
Resolution: Inspected on 2021 annual.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 April 2019
Resolved
Complete credit dry dock and internal structural examination prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2019
Resolved 24 May 2019
Resolution: Credit Drydock inspection completed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 June 2018
Resolved
Install two-hour emergency lighting in each stateroom located below the main deck that is used for overnight accommodations. Must install emergency lights prior to carrying passengers in overnight accommodations.
Action required: 705 - Other - as specified
Resolved 16 September 2019
Resolution: Observed test of installed emergency lighting. Data sheets provided show that lighting is rated for 2 hours.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 25 June 2018
Resolved
All mattresses must comply with either the U.S. Department of Commerce “Standard for Mattress Flammability” (FF 4-72.16) and not contain polyurethane foam or comply with IMO Resolution A.688(17). Provide documentation proving that the overnight accommodations in the vessel’s lounge meet one of the above standards or replace them with overnight accommodations that do prior to using those arrangements to carry passengers overnight.
Action required: 705 - Other - as specified
Resolved 16 September 2019
Resolution: Lounge area is not to be used as overnight accommodations.