Records from 2016 to 2026. Most recent: inspection, 18 January 2026.
Inspection history · 27
18 January 2026
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8298831
12 January 2026
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8294581
1 June 2024
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7924607
21 May 2024
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7912975
17 May 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7913910
27 February 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7871114
16 December 2023
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7840757
22 November 2023
PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7828548
8 November 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7822135
6 November 2023
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7820707
17 August 2023
PSC A
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7770305
24 May 2023
PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7695427
26 January 2023
Administrative Inspection · PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7627289
22 January 2023
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7625185
12 January 2023
Deficiency Check · ISM Exam · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7618107
10 January 2023
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7619322
23 September 2022
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7561209
19 November 2021
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7354084
18 November 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7353714
3 November 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7344511
30 November 2018
Deficiency Check · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6585789
20 November 2018
Deficiency Check
Physical examination · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 6679431
5 September 2018
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6532605
22 June 2018
PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6450748
19 June 2018
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6448870
13 June 2018
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6442977
23 March 2016
ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5838682
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 May 2024
Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society. PSCO observed oil leaking from 2 steering gear valves and steering gear oil tank. 2004 SOLAS II-1/3-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2024
Resolution: PSCO attended VSL after receiving Class Report and conducted steering gear test and found steering gear leaks to be resolved.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 17 August 2023
Resolved
Oil filtering equipment referred to in paragraph 1 of this regulation shall be of a design approved by the administration. PSCO observed pin hole leak in overboard pipe after 3-way valve. MARPOL I/14.6 16AC
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2023
Resolution: Pinhole leak rectified. system tested by running Sea to sea found satisfactory.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 17 August 2023
Resolved
The company should establish procedures, plans, and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel. PSCO observed multiple machinery equipment that was not safely secured from use by the crew on switchboard. No SMS procedures were found for securing switchboard. 74SOLAS(20) IX/3.1 ISM code 7 50AC
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 November 2023
Resolution: Receive RINA Audit report.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 August 2023
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed active F/O leak from #2 cylinder on A/E #1. 74SOLAS(04)II-2/4.1.1 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 September 2023
Resolution: pressure piece seatings replaced. #1 A/E tested found satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 17 August 2023
Resolved
After any survey of the ship under regulation 7, 8, 9, or 10 has been completed, no change shall be made in the structural arrangements. PSCO observed modified grease trap piping from galley passing through paint locker. 74SOLAS(20)I/11(a) 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 September 2023
Resolution: Modified grease trap removed and permanent pipe installed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 August 2023
Resolved
Structural fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO observed stairwell fire doors on 2nd, 3rd, and 5th deck that do not properly latch. 74SOLAS(20)II-2/14.2.1.1.1 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 September 2023
Resolution: fire doors latch repaired and tested foud satisfactory
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 August 2023
Resolved
Electrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. PSCO observed dryer connected to an unauthorized extension cord. 74SOLAS(01)II-1/40.1.3 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 September 2023
Resolution: Extension cord removed.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 17 August 2023
Resolved
Penetrations in these divisions shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO observed improper fire block for A-0 boundary penetration in electrical panel room on 1st deck. 74SOLAS(20)II-2/14.2.1.1.1 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 November 2023
Resolution: Received BV report
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 17 August 2023
Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the Oil Record Book Pt. 1 so that all entries in the book appropriate to that operation are completed. PSCO observed entries in the ORB that did not correspond to oil transfers made on multiple dates. MARPOL I/17.4 10C
Action required: 10 - Deficiency Rectified
Resolved 18 August 2023
Resolution: C/E made corrections to incorrect entries. Crew was educated on proper entries in ORB.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 January 2023
Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
PSCO observed the use of fabricated plastic drip trays to catch excess oil coming from NR1 and NR2 generators. A hose was fitted to the generator leading into plastic buckets due to an inoperable and blocked pipe. See attached pictures.
74SOLAS(20)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2023
Resolved 24 May 2023
Resolution: PSCO observed replacement part and report of repair
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 January 2023
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with additional requirements which may be established by the company. Due to the objective evidence in the deficiencies noted below, the vessel is not being maintained and not in substantial compliance with relevant conventions, calling into question the adequacy and implementation of the vessel's SMS under the ISM code. An external audit conducted by the Flag or RO is required before the ship will be released from its detention to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the completed audit report to USCG prior to departure from port.(74 SOLAS 20 XI-1 Regulation 4.1 ISM Code 10.2)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 16 January 2023
Resolution: Conducted an ISM audit, after an external and internal audit was conducted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 January 2023
Resolved
Firefighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed fault on the cargo space sample extraction smoke detection system for smoke detector lines 7 through 11 rendering the system inoperable. (74 SOLAS 20 II-2 Regulation 14.2.1.2)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 16 January 2023
Resolution: Conducted deficiency check, observed lines 7- 11 tested and alarm properly.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 12 January 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed all alarm towers throughout the machinery spaces were in a constant state of alarm and were unable to be reset. (74 SOLAS 20 I Regulation 11(a))
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 16 January 2023
Resolution: Conducted 2 smoke alarm tests, PSCO observed alarms functioning and clearing properly.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 January 2023
Resolved
A main electric lighting system which shall provide illumination throughout those parts of the ship normally accessible to crew shall be supplied from the main source of electrical power. PSCO observed numerous general and emergency lights throughout the machinery spaces were inoperable presenting a work and escape hazard to the crew. (74 SOLAS 04 II-1 Regulation 40.2.1)
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 26 January 2023
Resolution: PSCOS visited the ship in Houston, TX and checked emergency lighting and general lighting on a round in the engine room. Lights were all working and operable.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 January 2023
Resolved
Main and emergency switchboards shall be so arranged as to give easy access as may be needed to apparatus and equipment, without danger to personnel. PSCO observed upper panels of the main electrical switchboard located in the engine control room removed exposing high voltage electrical connections. (74 SOLAS 04 II-1 Regulation 45.2)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2023
Resolution: Switchboard covers were reinstalled and ventilation was working properly.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 January 2023
Resolved
Machinery spaces of category A shall be adequately ventilated so as to ensure an adequate supply of air is maintained to the spaces for the safety and comfort of personnel and the operation of machinery. PSCO observed upper panels of the main electrical switchboard located in the engine control room removed. When the crew was questioned it was noted that the panels were removed due to an overheating condition with the panel. (74 SOLAS II-1 Regulation 35)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2023
Resolution: PSCO observed switchboard covers reinstalled and switchboard ventilation operating properly.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 January 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed the electrical panel for the #2 fuel oil purifying system was found improperly mounted due to damage to the enclosure. (74 SOLAS 20 I Regulation 11(a))
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2023
Resolution: Corrective actions were taken to secure the panel. Vessel was able to produce a purchase order for a previous PLC and mounts that were sent out for repairs. Once spare PLC is received, the faulty PLC and cover will be sent out for repair.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 January 2023
Resolved
All electrical apparatus shall be so constructed and so installed as to not cause injury when handled or touched in the normal manner. PSCO observed the main engine programmable logic control enclosure to be in disrepair and presenting a electrical hazard to the crew as well as jeopardizing electrical components vital to the safe operation of the main engines. (74 SOLAS 04 II-1 Regulation 45.1.3)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2023
Resolution: PSCO observed the PLC Enclosure repaired and operating properly.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 September 2022
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Lifeboart engine would only start with one battery. 74SOLAS(20)III/20.2
Action required: 10 - Deficiency Rectified
Resolved 23 September 2022
Resolution: Vessel replaced secondary battery when they arrived in port.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 September 2022
Resolved
Ships shall be designed, constructed and maintained in compliance with elextrical requirements of a classification society. PSCO oberserved mast and stern light were not properly functioning. 74SOLAS(20)II-1/3-1
Action required: 10 - Deficiency Rectified
Resolved 23 September 2022
Resolution: Crew was able to install new switches that would stay compressed when selected for operation.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 23 September 2022
Resolved
Whenever there is a hazardous condition either onboard a vessel or caused by a vessel or its operation, the owner, agent, master , operator, or person in charge must notify the nearest Coast Guard Sector. Vessel failed to notify Sector Mobile of inoperable navigation lights. 33CFR160.216
Action required: 10 - Deficiency Rectified
Resolved 23 September 2022
Resolution: Master, Port Captain, and Flag representative were reminded of the requirement to report such findings as soon as possible to nearest C.G. unit.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 14 June 2018
Resolved
IF THE VESSEL'S RADAR STOPS OPERATING PROPERLY, THE PERSON DIRECTING THE MOVEMENT OF THE VESSEL MUST REPORT OR CAUSE TO BE REPORTED THAT IT IS NOT OPERATING PROPERLY TO THE NEAREST CAPTAIN OF THE PORT AS SOON AS POSSIBLE.
Action required: 10 - Deficiency Rectified
Due 14 June 2018
Resolved 14 June 2018
Resolution: Coast Guard became aware of issue while on board.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 13 June 2018
Resolved
2 1470 ALL SURFACES WITH TEMPERATURES ABOVE 220 C WHICH MAY BE IMPINGED A A RESULT OF FUEL SYSTEM FAILURE SHALL BE PROPERLY INSULATED. THERE IS OIL SOAKED LAGGING AND POOLS OF OIL AND AROUND THE ENGINE HOUSING. 74SOLAS(2001) II-2/15.2.10 30ABC
Action required: 30 - Ship detained
Due 13 June 2018
Resolved 16 June 2018
Resolution: Removed oil soaked insulation. Insulation that was oil soaked was not required on affected piping.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 13 June 2018
Resolved
3 0230 ALL SHIPS SHALL BE SUFFICIENTLY AND EFFICIENTLY MANNED. THE VESSEL IS NOT SUFFICIENTLY MANNED TO MEET THE REQUIREMENTS FOR A MANNED MACHINERY SPACE AS REQUIRED BY MINIMUM SAFE MANING DOC DUE TO INOP FIRE DETECT. VESSEL REQUIRES ADDITIONAL OICEW. 74SOLAS(2014) V/14.1 17BC
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2018
Resolved 16 June 2018
Resolution: Vessel is now in a "manned" engine room status as per BV report. Verified additional OICEW license and flag endorsement. Also, verified work/rest hours to allow crew to maintain continuous fire watch.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 13 June 2018
Resolved
04 2500 74 SOLAS (14) IX/ 3.1 17A
ISM CODE 10.1
THE COMPANY AND SHIP SHALL COMPLY WITH THE
REQUIREMENTS OF THE INTERNATIONAL SAFETY
MANAGEMENT CODE. FOR THE PURPOSES OF THIS
REGULATION, THE REQUIREMENTS
SHALL BE TREATED AS MANDATORY. THE COMPANY
SHOULD ESTABLISH PROCEDURES TO ENSURE THAT
THE SHIP IS MAINTAINED IN COMFORMITY WITH THE
PROVISIONS OF THE RELEVANT RULES AND REGULATIONS.
VERIFY ISM COMPLIANCE WITH REGARDS TO FIRE DETECTION
AND ALARM SYSTEM MAINTENANCEAND REPAIRS. RECOMMEND FULL ISM AUDIT.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2018
Resolved 16 June 2018
Resolution: RINA conducted ISM audit regarding fire detection system, and found no nonconformities.
Navigation › Collision/Grounding Avoidance › Radar
Issued 13 June 2018
Resolved
05 1530
ALL SHIPS OF 3000 GT AND UP SHALL BE FITTED WITH A 9 GHZ RADAR AND ALL SHIPS OF 3000 GT AND UP SHALL HAVE A 3 GHZ RADAR. X BAND RADAR DISPLAYING WEAK TARGETS, WHILE S BAND RADAR WAS DISPLAYING A SINGLE TARGET AS MULTIPLE TARGETS.
74 SOLAS (14) V/ 19.2.3.2 & 19.2.7.1
10C
Action required: 10 - Deficiency Rectified
Due 13 June 2018
Resolved 13 June 2018
Resolution: Coast Guard became aware of issue while on board.