← All vessels
CRETAN WAVE
CRETAN WAVE is a 2001 freight ship. The Coast Guard has recorded 17 inspections since 2001, most recently in February 2016, along with 8 deficiencies and 2 operational controls.
Records from 2001 to 2016. Most recent: inspection, 4 February 2016.
- Built
- 2001
- Last inspected
- 4 February 2016
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 8 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9227675 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C4XH2
21048
Flag
CYPRUS
—
Maury page id
psix-21048
Inspections, by type
…with no type recorded5
Years with a record
10 calendar years (2001–2016)
The 17 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it25413 - Convention (Subpart B), Net Ton
74107 - Dead Weight, Ton
84545 - Displacement, Ton
38835 - Convention (Subpart B), Gross Ton
74107 - Dead Weight, Ton
84545 - Displacement, Ton
38835 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 17
4 February 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5805414
25 March 2010
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3694821
14 June 2008
PII Safety Exam · Ballast Water Examination · ISPS I Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3230142
19 March 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3236224
26 March 2007
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2898163
22 March 2007
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2892712
6 April 2006
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2618577
8 February 2006
ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2581571
6 December 2005
Administrative Inspection · Random ISPS/MTSA/PSC
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2547208
3 October 2005
Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2506474
11 January 2005
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 2273120
7 December 2004
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2255430
16 August 2004
PII Safety Exam · ISPS II Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2167298
2 March 2004
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2016610
27 September 2003
Deficiency Check · Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1914374
18 June 2002
Ballast Water Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1632776
20 February 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 287248
Deficiency record · 8
Construction/Loadline › Hull › Bracket
Issued 4 February 2016
Resolved
COAMING TO EXPOSED HATCHWAYS ON DECKS ABOVE THE SUPERSTRUCTURE DECK SHALL COMPLY WITH THE REQUIREMENTS OF THE ADMINISTRATION. PSCO FOUND 02 CORNER BRACKETS WITH CRACKS ON THE #4 CARGO HOLD COAMING AND 02 CORNER BRACKETS WITH CRACKS ON THE #5 CARGO HOLD COAMING, VARYING 15 TO 25 CM IN LENGTH
Documentation › Certificates/Documents › Exemption Letter (CFIV)
Issued 6 April 2006
Resolved
Certificate of Class document is invalid.
Fire Fighting › Fire Pumps › Pressure
Issued 6 December 2005
Resolved
Vessels emergency fire pump did not provide any pressure to the ships fire main. prior to its return to the U.S.-- the conditions during our Port State Control exam of 10 December 05 will be repeated by class and any problem discovered will be reported & resolved through the vessel's safety management system. 70a
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System › Quantity of Foam-Forming Liquid
Issued 4 October 2005
Resolved
Vessel to provide copy of the Foam Concentrate report. Service date indicated on tank expired November 2004. Can be verified with service report to the USCG or via class report.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 3 October 2005
Resolved
Steering gear alarm did not work on bridge, either visual or audio. Alarms still indicated at ECR which is manned. Class to attest to repair and proper operation.
Lifesaving › Lifeboat
Issued 18 June 2002
Resolved
PORT LIFEBOAT DOOR BENT AND HANDLE BROKEN THROUGH TOP OF BOAT. MAKE REPAIRS TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Rigid Cover
Fire Fighting
Issued 20 February 2001
Resolved
NOTED CREW WAS NOT FAMILIAR WITH SHIP'S PRIMARY FIXED FIRE FIGHTING_x001C_ SYSTEM (FOAM). CREW TO PRACTICE IAW SHIPBOAORD INSTRUCTIONS AND DEMONSTRATEOPERATION PRIOR TO DEPARTURE._x001C_ SOLAS 74 AMENDED III/19.4_x001C_
Fire Fighting
Issued 20 February 2001
Resolved
NOTED FIRE DRILL TO BE UNSATISFACTORY IAW SOLAS. FIRE TEAM DID NOT RESPOND IN SUFFICIENT TIME (15 MIN. PLUS). NOTED FIRE EQUIPMENT WAS NEW AND STILL IN PLASTIC PACKAGES. FIRE TEAM DID NOT RESPOND FULL OUTFITTED. POOR TECHNIQUE. SOLAS 74 AMENDED III/19.3.4
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.