MAURY USCG vessel records Sign in
← All vessels

ELPIDA

ELPIDA is a 2001 freight ship. The Coast Guard has recorded 18 inspections since 2002, most recently in June 2018, along with 6 deficiencies and 3 operational controls.

Records from 2002 to 2018. Most recent: inspection, 1 June 2018.

Built
2001
Last inspected
1 June 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9218284 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA4458
Flag
MALTA
—
Maury page id
psix-21050

Inspections, by type

…with no type recorded8
Years with a record 9 calendar years (2002–2018)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it24622 - Convention (Subpart B), Net Ton
73311 - Dead Weight, Ton
83246 - Displacement, Ton
38367 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 4

Inspection history · 18

1 June 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6431445
2 May 2018 Deficiency Check · ISPS II Exam · PII Safety Exam · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6403802
5 January 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5787496
15 February 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3940669
17 February 2009 MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3416351
24 October 2007 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3082498
23 October 2007 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3085531
5 April 2006 ISPS III Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2617585
27 March 2006 PII Safety Exam · ISPS I Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2610080
27 March 2006 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2610578
16 October 2005 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2515688
30 September 2005 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2504794
19 September 2005 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2498239
3 December 2004 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2252938
2 December 2004 Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2251810
24 October 2002 Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1695512
20 October 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1693175
20 October 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1707132

Deficiency record · 6

Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 2 May 2018 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to...other hazards. The vessel experienced an equipment failure while transiting the navigable waters of the United States which adversely affected its maneuverability and posed a hazard to vessels and infrastructure along the Houston Ship Channel. Submit for review a Classification Society report to [email withheld] attesting to the cause of the equipment failure, that authorized temporary or permanent repairs have been completed, and that the vessel's full and normal maneuverability has been restored. 74SOLAS(04)II-1/26
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2018
Resolved 4 May 2018
Resolution: CG Sector Houston Galveston PSC branch received a class report from NKK satisfying the requirement.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 2 May 2018 Resolved
The company should identify equipment and technical systems the sudden operational failure of which may result in hazardous situations. The safety management system should provide for specific measures aimed at promoting the reliability of such equipment or systems. The vessel experienced an equipment failure while transiting the navigable waters of the United States which adversely impacted its fitness and capability to safely maneuver the Houston Ship Channel. Submit evidence to [email withheld] detailing how this hazardous situation was reported to the company, investigated, and analyzed with the objective of improving safety, including the implementation of corrective action and measures intended to prevent recurrence (as detailed and required in ISM A/9). 74 SOLAS (14) IX/3.1 Ref. ISM A/9 & 10.3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2018
Resolved 1 June 2018
Resolution: SEC HOU-GAL PSC received a class report from NKK satisfying the requirement.
Navigation › Collision/Grounding Avoidance › Radar
Issued 15 February 2011 Resolved
1530 - Radar- All ships of 3,000 gross tons and upwards shall have a 9 GHz radar, or other means, to determine and display the range and bearing of radars transponder and in addition a 3 GHz radar. Vessel requested a deviation to enter the port for inoperable radar - SOLAS 74a V/19
Action required: 705 - Other - as specified
Due 15 February 2011
Resolved 15 February 2011
Resolution: Received, reviewed and accepted documentation from Radio Holland USA stating the deficiency was rectified. Technician replaced power supply due to shut down problems.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 15 February 2011 Resolved
0830- Pipes - Each transfer pipe system must not leak under static liquid pressure at least 1.5 times the maximum allowable working pressure. Vessel did not conduct a static liquid pressure test in accordance with US regulations - 33 CFR 156.170.
Action required: 705 - Other - as specified
Due 15 February 2011
Resolved 15 February 2011
Resolution: Received proper documentation from the Master of the vessel certifying the fuel oil bunker lines were pressure tested IAW 33CFR156.170.
Lifesaving › Launching Appliances › Release Mechanism
Issued 27 March 2006 Resolved
Both port and starboard lifeboats failed to be launched from the stowed position. Vessel must prove proper operation of both the port and starboard lifeboat launching arrangements to the satisfaction of class. The class report must detail the cause of the malfunction. Vessel must also file a ISM non-conformity to the company, prior to departure and the satisfaction of class.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2006
Resolution: Class report was recived.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 2 December 2004 Resolved
The Marine Sanitation Device is not properly labeled. Have labeled prior to next U.S. Port after sailing foreign.
Action required: 705 - Other - as specified
Resolved 4 December 2004
Resolution: CG Boarding Officer inspected class certificate of CG approved MSD device.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.