Records from 2016 to 2021. Most recent: inspection, 13 April 2021.
Documentation record
Registered dimensions (L × B × D)72.0 ft × 26.0 ft × 5.5 ft
Registered tonnagegross 42 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN CATAMARANS INC · TARPON SPRINGS, FL, UNITED STATES · built 2001
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portMIAMI, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 July 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Simplified, Net Ton
42 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 10
13 April 2021
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7174092
19 November 2020
Hull Examination · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7097926
30 September 2020
Deficiency Check · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7069339
24 August 2020
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7041734
8 May 2020
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6950212
1 July 2019
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6733133
29 November 2018
Internal Structural Exam · Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6585278
4 June 2018
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6431856
6 December 2016
Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6054363
4 April 2016
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5846641
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 September 2020
Resolved
Audible signal for bilge alarm is inoperable.
Action required: 10 - Deficiency Rectified
Resolved 30 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 July 2019
Resolved
Each ring life buoy on a vessel must: be approved in accordance with 160.050 in Subchapter Q of this chapter, or other standard approved by the Commandant. One of the three lifebouys were delaminated, therefore negating its Coast Guard approval for its use as designed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 1 July 2019
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16) (incorporated by reference; see 46 CFR 175.600). Life jackets observed to have unapproved retroreflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 September 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 July 2019
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The first aid kit was missing item(s) required by 46 CFR 160.041.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 September 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 July 2019
Resolved
All vessels must have navigation lights that are incompliance with the applicable sections of the International and Inland Navigation Rules. The anchor light was inoperative.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 July 2019
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, other than small buoyancy compartments, under all practicable conditions. A Starboard automatic float switch was observed unsecured.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 September 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 1 July 2019
Resolved
A hatch exposed to the weather must be watertight. Hatch covers gaskets were unsecure.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 September 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions. All top deck overhead lights are inoperative and some light fixtures are missing protective covers (heads and closets).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 September 2020
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 July 2019
Resolved
System design and installation must be in accordance with the Marine Design, Installation, Operation, and Maintenance Manual approved for the system by the Commandant. Ensure that the vessel Fire Boy Fixed Fire Suppression System is installed in accordance with manufacturer’s instructions. Engine shutdown system controls at operating station are incorrectly installed and manual pull stations in way of bar area appear to not have been inspected and tested. Provide a satisfactory detailed servicing report from a qualified third party.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 September 2020
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 5 April 2016
Resolved
Tighten loose engine mount located STBD MDE outboard aft mount.
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 7 April 2016
Resolution: Tightened loose engine mount located STBD MDE outboard aft mount.
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 April 2016
Resolved
Tighten loose battery terminal STBD Engine room
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 5 April 2016
Resolution: Terminal was tightened prior to Inspector departure.
Fire Fighting › Fire Pumps › Power Source
Issued 5 April 2016
Resolved
Adjust fire pump drive belt
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2016
Resolution: Adjusted fire pump drive belt
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 5 April 2016
Resolved
Prove proper operation of Pre-Engineered fixed
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2016
Resolution: Proved proper operation of Pre-Engineered fixed
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 5 April 2016
Resolved
Replace wasted portable fire extinguisher bracket located STBD side embarkation
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 7 April 2016
Resolution: Replaced wasted portable fire extinguisher bracket located STBD side embarkation
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 April 2016
Resolved
Obtain valid Certificate of Documentation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2016
Resolution: Obtained valid Certificate of Documentation
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 April 2016
Resolved
Replace both Port and STBD running lights, both lenses are cracked
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2016
Resolution: Replaced both Port and STBD running lights