Records from 1983 to 1991. Most recent: inspection, 29 May 1991.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Unknown
Issued 9 April 1989
Resolved
REPAIR APPROX 49" TEAR OF WELD IN STBD LEG HIGH STRENGTH STEEL SIDE SHELL TO BTM PLATE. A REPAIR PROPOSAL & WELDING PROCEDURE SHALL BE FORWARDED TO [name withheld] PRIOR TO REPAIRS FOR APPROVAL & REPAIRS SHALL BE PERFORMED BY AN APPROVED WELDER. VSL MAY NOT BE PLACED IN SERVICE UNTIL REQ IS MET.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Construction/Loadline
Issued 9 April 1989
Resolved
PROVIDE DIVERS REPORT FOR UNDERWATER HULL SURVEY AND STILL COLOR PHOTOGRAPHS OF DAMAGED STBD LEG TO [name withheld].
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989
Resolved
PROVIDE EQUIP FOR STBD MOTOR L/B: 2 L/J W/LIGHT, WHISTLE & REFLECTIVE TAPE,COMPASS LIGHTSTICKS, 132 QTS WTR,88LBS PROVISIONS,44LBS SWEETENED COND MILKJACKNKFE,FISHING KIT,12 EA.RED FLARES-PARACHUTE & HANDHELD,2 FLOATING ORANGSMOKE, ALL CG APPR,ASPRIN,1AT ILLUMINATING OIL,1GAL STORM OIL WHI & SER COM
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Electrical
Issued 9 April 1989
Resolved
MAKE PROPER INSTALLATION OF PORT MOTOR LIFEBOAT WINCH POWER CORD TO CONTROLLER WHICH HAS SPLICE INSTALLED.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Construction/Loadline
Issued 9 April 1989
Resolved
INSTALL GASKET FOR WATERTIGHT DOOR TO AUXILIARY GENERATOR ROOM.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Construction/Loadline
Issued 9 April 1989
Resolved
REPAINT ALL VESSEL HULL MARKINGS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989
Resolved
PROVE PROPER OPERAITON OF EMBARKATION LADDERS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Electrical
Issued 9 April 1989
Resolved
PROVE PROPER OPERATION OF ALL H2S AND COMBUSTIBLE GAS SENSORS AND ALARMS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Fire Fighting
Issued 9 April 1989
Resolved
REPLACE THE EXPENDED CO2 ACTIVATION CARTRIDGE AND DRY CHEMICAL BOTTLE RUPTURE DISC FOR THE GALLEY FIXED DRY CHEMICAL FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989
Resolved
PROVIDE WINCH BRAKE COVER FOR STARBOARD LIFERAFT STATION.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989
Resolved
RENEW 12 CG APPROVED RED PARACHUTE FLARES IN THE CONTROL ROOM.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Fire Fighting
Issued 9 April 1989
Resolved
PROVIDE A SPANNER WRENCH AT FIRE STATION #9, FIRE STATION #10, FIRE STATION#17 AND FIRE STATION #18.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989
Resolved
RENEW BOTH EXPIRED SELF-ACTIVATING SMOKE SIGNALS, APPROVED UNDER 46 CFR 160.057 AT THE LAUNCHABLE RING BUOY STATIONS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Fire Fighting
Issued 9 April 1989
Resolved
PROVIDE 18 U.L. APPROVED 1 1/2"X50' FIRE HOSES.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989
Resolved
RENEW 4 CARTRIDGES AND 4 ROCKET PROJECTILES FOR LINE THROWING GUN.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Fire Fighting
Issued 9 April 1989
Resolved
PROVIDE FOR EACH OF THE TWO FIREMEN'S OUTFITS AN OXYGEN AND EXPLOSIVE METER LISTED BY UNDERWRITER'S LABORATORIES, INC. OR FACTORY MUTUAL AS EXPLOSION PROOF AND A SELF-CONTAINED BREATHING APPARATUS APPROVED UNDER 46 CFR 160.011.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989
Resolved
REPLACE 3 RING BUOYS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989
Resolved
PROVIDE ON FUNCTIONAL INFLATABLE LIFERAFT AUTOMATIC RELEASE HOOK, CG APPROVED.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989
Resolved
PROVIDE LIFEJACKET STORAGE CONTAINER ON PORT AND STARBOARD MOTOR LIFEBOAT STATION.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Navigation
Issued 9 April 1989
Resolved
RENEW BOTH FORWARD OBSTRUCTION LIGHT LENSES.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Construction/Loadline
Issued 9 April 1989
Resolved
REPAIR PORT AND STARBOARD OUTBOARD MAIN DECK CARGO HATCHES.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989
Resolved
PROVIDE EQUIP FOR PORT MOTOR L/B: 2 L/J W/LIGHT,WHISTLE & REFLECTIVE TAPE, COMPASS LIGHTSTICKS 132QTS WTR,88LBS PROVISIONS,44LBS SWEETENED COND MILE, JACKNIFE,FISHING KIT,12 EA RED FLARES-PARACHUTE & HANDHELD,2 FLOATING ORANGSMOKE-ALL CG APPROVED,1QT ILLUMINATING OIL,1GAL STORM OIL & SERVICE COMPASS
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989
Resolved
PROVIDE FOUR (4) SERVICED 25 MAN DAVIT-LAUNCHED INFLATABLE LIFERAFTS, CG APPROVED TYPE.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989
Resolved
PROVIDE 31 CG APPROVED LIFEJACKETS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989
Resolved
REPLACE THE FOLLOWING MISSING EQUIPMENT FOR THE VESSEL'S LIFEJACKETS: 43 LIGHTS, 21 WHISTLES AND LIGHTS, 16 LIGHTS AND REFLECTIVE TAPE AND 1 WHISTLELIGHT, REFLECTIVE TAPE AND VESSEL'S NAME ON BACK.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 10 May 1985
Resolved
PROVIDE THE FOLLOWING MISSING EQUIPMENT FOR THE STARBOARD LIFEBOAT: 1 FISH-ING KIT, 3 HAND-HELD ROCK PROPELLED PARACHUTE RED FLARES, 2 BOXES OF MATCHES (IN A WATERTIGHT CONTAINER), FIRST AID KIT (12 SAFETY PINS, 1 SCISSORS, 1 FORCEPS), 672 (4 OZ) PACKAGES OF WATER (28 PERSONS).
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Lifesaving
Issued 10 May 1985
Resolved
PAINT IN 3 INCH RED BLOCK LETTERS ON THE BULKHEAD BEHIND EACH LIFERAFT DAVIT A SIGN SAYING: "LOWER TOW BRIDAL PRIOR TO LAUNCHING RAFTS".
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Lifesaving
Issued 10 May 1985
Resolved
REPAIR THE PORT MOTOR LIFEBOATS SPRINKLER SYSTEM WATER PUMP.
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Lifesaving
Issued 10 May 1985
Resolved
REPLACE THE FOLLWING MISSING EQUIPMENT FOR THE VESSELS LIFEJACKETS: 8 WHISTLES, 16 WHISTLES AND RETROREFLECTIVE TAPE, 3 WHISTLES AND RETROREFLEC-TIVE TAPE AND LIGHTS, 1 WHISTLE, RETROREFLECTIVE TAPE, LIGHTS AND NAME OF VESSEL ON BACK.
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Lifesaving
Issued 10 May 1985
Resolved
PROVIDE THE FOLLOWING MISSING EQUIPMENT FOR THE PORT MOTOR LIFEBOAT: 1 FISHING KIT, 3 HAND-HELD ROCKET PROPELLED RED PARACHUTE FLARES, 2 BOXES OF MATCHES (IN A WATERTIGHT CONTAINER), 2 LIFEJACKETS LIGHTS, 937 (4 OZ) PACKAGES OF WATER (39 1/12 PERSONS).
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Construction/Loadline
Issued 10 May 1985
Resolved
REPAIR (APPROXIMATELY 44 INCH) TEAR IN THE STARBOARD LEG'S SIDE SHELL (A HIGH STRENGTH STEEL) WHERE THE RECESSED BOTTOM PLATING IS ATTACHED TO THE SIDE SHELL AN APPROVED WELDING PROCEDURE SHALL BE OBTAINED PRIOR TO THIS REPAIR AND THE REPAIR SHALL BE PERFORMED BY AN APPROVED WELDER.
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Lifesaving
Issued 10 May 1985
Resolved
RENEW BOTH EXPIRED SELF-ACTIVATING SMOKE SIGNALS (APPROVED UNDER 46 CFR 160.057) AT THE LAUNCHABLE RING BUOYS STATIONS.
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Lifesaving
Issued 10 May 1985
Resolved
EITHER PROVIDE ON BOARD THE VESSEL, 12 HAND-HELD ROCKET PROPELLED, PARA- CHUTE RED FLARES (MEETING 46 CFR 160.036) OR PROVIDE ON BOARD THE U.S. COAST GUARD APPROVED GUN (46 CFR 160.028/10/2) FOR THE RED PARACHUTE DIS- TRESS FLARES (PRESENTLY ON BOARD).
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Fire Fighting
Issued 10 May 1985
Resolved
PROVIDE FOR EACH OF THE (2) FIREMAN'S OUTFITS AN OXYGEN METER LISTED BY FM/CSA/UL AS EXPLOSION PROOF.
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Fire Fighting
Issued 10 May 1985
Resolved
REPLACE THE EXPENDED CO2 ACTUATION CARTRIDGE FOR THE GALLEY'S FIXED DRY CHEM FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Fire Fighting
Issued 10 May 1985
Resolved
REPLACE THE RUPTURE DISC ON THE DRY CHEM BOTTLE FOR THE GALLEY'S FIXED DRY CHEM FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Fire Fighting
Issued 10 May 1985
Resolved
READJUST THE FUSIBLE LINKS' ACTUATION LINKAGE FOR THE GALLEY'S FIXED DRY CHEMICAL FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985