MAURY USCG vessel records Sign in
← All vessels

SALLY T

SALLY T is a 1982 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1987, most recently in October 2018, along with 114 deficiencies — 1 with no resolution recorded —.

Records from 1987 to 2018. Most recent: inspection, 3 October 2018.

Built
1982
Last inspected
3 October 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ3450
211572
Flag
UNITED STATES
367413710 (licence lapsed)
Maury page id
psix-211572

Inspections, by type

…with no type recorded3
…past their stated due date1
Years with a record 29 calendar years (1987–2018)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it43 - Regulatory (Subpart C or D), Gross Ton
29 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCZ3450MMSI 367413710 · expired · compulsorily equipped · granted 6 June 2009, cancelled 17 August 2019
WUV4531MMSI not assigned · expired · compulsorily equipped · granted 21 July 1998, cancelled 6 December 2008 · licensed under a name not among this hull’s recorded names (not shown)
WCP9269MMSI not assigned · expired · compulsorily equipped · granted 9 February 1995, cancelled 16 April 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 61

3 October 2018 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6553792
28 March 2018 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6380552
15 September 2017 Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6265706
5 October 2016 Annual Inspection · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6000362
26 July 2016 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5952994
5 July 2016 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5930164
17 June 2014 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4891122
27 May 2014 Deficiency Check · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4871306
8 May 2012 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4275609
7 February 2012 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4241553
10 August 2011 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4113341
24 March 2010 DAPI Audit · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3701759
22 February 2010 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3675329
4 April 2008 Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3141733
4 April 2008 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3181444
6 November 2007 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3093920
10 July 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2991434
22 March 2007 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2892572
22 March 2006 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2607171
13 January 2006 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2568091
14 March 2005 Deficiency Check · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2309527
12 March 2004 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2034620
4 February 2004 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2000319
14 January 2004 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1984450
21 February 2003 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1747623
11 February 2002 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1485421
14 January 2002 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1477958
1 March 2001 Re-Inspection · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1399543
11 February 2000 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1426331
5 January 2000 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1434969
6 December 1999 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 813708
23 November 1999 Plan Review "T" Boat
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 801493
1 July 1999 Deficiency Check · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1434894
10 March 1999 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 803464
12 March 1998 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1111175
10 December 1997 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1115160
17 September 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 779309
19 March 1997 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1103055
1 April 1996 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1079726
11 March 1996 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 885051
22 August 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 879271
14 March 1995 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1179359
7 June 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 864818
3 June 1994 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 864936
9 June 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1155349
28 April 1993 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1148994
7 October 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261261
11 December 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 950632
9 October 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 939486
17 October 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 934862
2 August 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1228294
27 July 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1232986
5 December 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 915025
26 October 1989 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1317950
22 May 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 890001
12 November 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 895602
16 August 1988 Deficiency Check · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1038293
3 August 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1039981
12 July 1988 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1033226
28 September 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1319648
5 August 1987 Initial Certification · Hull Examination · Plan Review "T" Boat
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1336395

Deficiency record · 114

Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 March 2018 No resolution recorded
Vessel drydock examination was due on February 28, 2018. Vessel is restricted from carrying passengers until an approved credit drydock exam is completed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2018 — due date passed with no resolution recorded
Communications › Radio Communications › EPIRB
Issued 15 September 2017 Resolved
EPIRB must be installed to automatically float free. Disposable hydrostatic release is expired, replace with new. Restricted to three nautical miles from shore. 46 CFR 180.64
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2017
Resolved 25 September 2017
Resolution: Owner installed a new disposable hyrostatic release on the EPIRB.
Stability › Watertight Integrity › General
Issued 15 September 2017 Resolved
Good marine practice requires vessel to be water tight. Remove valve handle on the through hull fitting to seachest for firemain/bilge piping to ensure valve remains closed. 46 CFR 176.800(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 October 2017
Resolved 25 September 2017
Resolution: Owner removed valve handle on the through hull fitting to seachest for firemain/bilge piping.
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 September 2017 Resolved
Connections to battery terminals must be made with permanent type connectors. Replace wing nuts with permanent type connectors. 46 CFR 183.350(d)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 October 2017
Resolved 25 September 2017
Resolution: Owner replaced wing nuts with permanent type connectors.
Electrical › Electrical Distribution System (service) › Cable
Issued 15 September 2017 Resolved
All cables and wires must be installed with metal supports spaced not more than 24 inches apart. Install metal supports in engine room not more than 24 inches apart for new cables and wires. 46 CFR 183.340(b)(4)
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 October 2017
Resolved 25 September 2017
Resolution: Owner installed metal supports in engine room not more than 24 inches apart for new cables and wires.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 15 September 2017 Resolved
Vessel must carry adequate and up-to-date U.S. Coast Pilot or similar publication for intended voyage. Vessel does not have U.S. Coast Pilot, acquire. 46 CFR 184.420(a)(2)
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 October 2017
Resolved 25 September 2017
Resolution: Vessel acquired U.S. Coast Pilot for area of operation.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 17 October 2016 Resolved
Demonstrate ability to perform successful man overboard drill with rescue platform/ladder.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 October 2016
Resolution: Vessel demonstrated a successful man overboard rescue.
Stability › Watertight Integrity › General
Issued 17 October 2016 Resolved
Remove valve handle on the through hull fitting to seachest for firemain/bilge pipint to ensure valve remains closed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2016
Resolution: Valve was closed and handle removed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 October 2016 Resolved
Post COI where it can be visible to passengers.
Due 24 October 2016
Resolved 24 October 2016
Resolution: Posted a copy of the COI in the passenger cabin.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 17 October 2016 Resolved
Port and starboard engines have exhaust leaks in discharge piping. (46 CFR 176.25-50(a))
Due 24 October 2016
Resolved 24 October 2016
Resolution: Exhaust leaks were repaired.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 13 October 2016 Resolved
Port and starboard engines have exhaust leaks in discharge piping. (46 CFR 176.25-50(a))
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2016
Resolution: Starboard engine exhaust leak has been repaired. Issued new deficiency for port leak.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 13 October 2016 Resolved
Provide fire servicing certifactes for fixed CO2 system and onboard extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2016
Resolution: Provided fire servicing certificate for review.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 13 October 2016 Resolved
Provide proof of drug consortium enrollment for 2nd crewmember.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2016
Resolution: Provided proof of enrollment.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 13 October 2016 Resolved
Alcohol test strips are expired. Provide valid alcohol test strips. Strips are on order. Vessel is restricted to operating a maximum of 2 hours from the dock.
Action required: 705 - Other - as specified
Due 24 October 2016
Resolved 24 October 2016
Resolution: Operator obtained unexpired alcohol test strips.
Lifesaving › Lifefloat › Painter
Issued 13 October 2016 Resolved
Reattach branch line from main painter to the port side life float.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2016
Resolution: Lifefloats were configured properly to painter.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 13 October 2016 Resolved
2 lifejackets were taken out of service due to the condition of their clips. Only 44 adult lifejackets onboard were in satisfactory condition. Provide an adult lifejacket or passenger count will be limited to 44 persons.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2016
Resolution: Lifejackets were replaced with ones in satisfactory condition.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 13 October 2016 Resolved
Remove oil & water in the engine room bilge. (46 CFR 176.25-50)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2016
Resolution: Excessive oily water was removed from the bilge.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 13 October 2016 Resolved
Provide clear means of communicating a passenger list ashore to a designated representative for each voyage that can be reached by the CG.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2016
Resolution: Operator provided a signed letter of agreement with the Marina regarding the ashore passenger and crew list.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 13 October 2016 Resolved
Provide up-to-date navigational charts onboard.
Action required: 705 - Other - as specified
Due 20 October 2016
Resolved 17 October 2016
Resolution: Provided up-to-date charts onboard.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 13 October 2016 Resolved
Provide adequate and up-to-date U.S. Coast Pilot onboard.
Action required: 705 - Other - as specified
Due 20 October 2016
Resolved 17 October 2016
Resolution: Provided Coast Pilot.
Lifesaving › Lifebuoys › Stowage
Issued 13 October 2016 Resolved
Ring life buoy must be relocated to the passenger deck where it is readily accessible.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2016
Resolution: Life Ring Buoy was relocated to passenger deck.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 October 2016 Resolved
Vessel failed to conduct annual exam within 3 months of anniversary date for endorsement to maintain COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2016
Resolution: Vessel completed Annual Inspection pending successfully Man Overboard Drill.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 July 2016 Resolved
Vessel's Hull Exam Due Date of 29 FEB 2016 is overdue by 4 months,Vessel is restricted from operating until approved credit drydock from Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2016
Resolution: Attended Vessel for scheduled hull exam (see Activity 5952994).
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 18 June 2014 Resolved
Port fuel tank shutoff valve inoperable. Repair to the satisfaction of attending USCG Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2014
Resolution: O/O reattached reach rod to shutoff valve with adequate metallic wires similar to starboard side. Verified valve operation multiple times: all sat.
Electrical › Electric Generation Source (service) › Generator
Issued 18 June 2014 Resolved
Generator inoperable due to coolant leak. Repair to the satisfaction of attending USCG Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2014
Resolution: O/O repaired generator. Successfully energized generator and visually inspected for signs of leakage; all sat.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 18 June 2014 Resolved
Deckhand not not in full compliance with consortium. Show proof of cull compliance to attending USCG Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2014
Resolution: Required deckhand provided proof of enrollment in Maritime Consortium; deckhand is in full compliance until December 2014; all sat.
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 June 2014 Resolved
Fire and man overboard drills not conducted. Perform drills to the satisfaction of attending USCG Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2014
Resolution: Conducted MOB and fire drills underway; all sat.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 18 June 2014 Resolved
Batteries in 02 life float waterlights were expired. Replace with new batteries.
Due 2 July 2014
Resolved 3 July 2014
Resolution: 02 life float waterlights replaced with new batteries labeled with expiration dates; float tested waterlights to verify buoyancy and operation; all sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 June 2014 Resolved
Battery in the life ring floating waterlight was expired. Replace with new batteries.
Due 2 July 2014
Resolved 3 July 2014
Resolution: Life ring waterlight replaced with new battery; floated tested; all sat.
Lifesaving › Hand Flares › Quantity
Issued 18 June 2014 Resolved
Required 12 total distress signals. Missing 04 distress signals. Provide distress signals.
Due 2 July 2014
Resolved 3 July 2014
Resolution: O/O purchased 04 red distress signals; vessel has total of 12 distress signals; all sat.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 18 June 2014 Resolved
Emergency check-off list was not specific to the vessel. Make list/procedures vessel specific.
Due 2 July 2014
Resolved 3 July 2014
Resolution: Updated emergency list/instruction reflecting vessel''s actual procedures; all sat.
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 18 June 2014 Resolved
Hydraulic hoses for starboard engine were supported by plastic wire ties. Provide adequate hose support.
Due 2 July 2014
Resolved 3 July 2014
Resolution: Plastic wire ties supporting hydraulic hoses on starboard engine replaced with metallic wire support. Visually verified metal wire support to be adequate; all sat.
Engineering › Bilge Water Management System › Not Operational
Issued 2 May 2012 Resolved
Fixed power bilge pump was not operable. Repair or replace and provide operational test to satisfaction of CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2012
Resolved 8 May 2012
Resolution: Tested bilge system in all required spaces using fixed bilge pump, test sat.
Personnel › Training › First Aid/CPR
Issued 25 April 2012 Resolved
First Aid/CPR cards expired. Provide up to date first aid/CPR cards for 50% of crew to satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Due 25 May 2012
Resolved 30 August 2012
Resolution: Provided first air/cpr cards dated 28AUG12 for 50% of crew.
Navigation › Piloting/Steering › US Coast Pilot
Issued 25 April 2012 Resolved
US Coast Pilot dated 1999. Provide up to date US Coast Pilot to satisfaction of CG Marine Inpsector.
Condition: Improper/Lack of Maintenance
Due 9 May 2012
Resolved 2 May 2012
Resolution: Provided updated US Coast Pilot.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 25 April 2012 Resolved
Missing Tide Tables and Tidal Current Tables. Make available to CG Marine Inspector.
Due 9 May 2012
Resolved 2 May 2012
Resolution: Provided updated tide/tidal current tables.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 25 April 2012 Resolved
Missing emergency instructions at operating station. Provide emergency instructions at operating station to CG Marine Inspector.
Due 9 May 2012
Resolved 2 May 2012
Resolution: Provided copy of emergency instructions at operating station.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 25 April 2012 Resolved
Missing 9 adult life preservers. Passenger count reduced to 34 and total persons 36.
Condition: Improper/Lack of Maintenance
Due 25 May 2012
Resolved 8 May 2012
Resolution: 10 new type 1 PFDs provided on vessel.
Engineering › Fuel Oil Service System › Hose
Issued 25 April 2012 Resolved
Provide appropriate chafing gear on fuel supply line for stbd engine to satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Due 9 May 2012
Resolved 2 May 2012
Resolution: Chafing gear provided on fuel supply line.
Electrical › Electric Generation Source (service) › Generator
Issued 25 April 2012 Resolved
Generator was not operable. Provide two sources of electricity to satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2012
Resolved 2 May 2012
Resolution: Generator was operable.
Engineering › Bilge Water Management System › Pump
Issued 25 April 2012 Resolved
Fire Pump and Fixed Power Bilge Pump was not operable. Repair or replace and provide operational test to satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2012
Resolved 2 May 2012
Resolution: Fire pump tested satisfactory, bilge system did not work and new CG-835 was issued.
Operations/Management › Drills/Instruction › Not Conducted
Issued 25 April 2012 Resolved
Provide operational test of all equipment and conduct fire and man overboard drills to satisfaction of CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2012
Resolved 2 May 2012
Resolution: Conducted satisfactory man overboard and fire drill.
Engineering › Fuel Oil Service System › Valve, Control
Issued 28 February 2012 Resolved
Both port and starboard fuel shutoff reach rods are wasted. Cite: 46 CFR 182.20-40
Due 28 March 2012
Resolved 25 April 2012
Resolution: Operator tested both fuel shut off valves, test sat.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 April 2010 Resolved
Only 35 adult lifejackets on board. Vessel is restricted to 35 persons on board IAW 46 CFR 180.71. Provide additional lifejackets to meet COI requirements within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2010
Resolved 20 May 2011
Construction/Loadline › Hull › Hull Plating
Issued 22 February 2010 Resolved
Crop and renew area of deck on main deck with marine grade plywood on foc'sle on portside under bench seating as marked 3'x2'.
Condition: Improper/Lack of Maintenance
Due 2 March 2010
Resolved 22 February 2010
Resolution: Deck replaced as required.
Construction/Loadline › Hull › Hull Plating
Issued 22 February 2010 Resolved
Crop and renew area of deck on main deck with marine grade plywood on foc'sle on starboard under bench seating as marked 2'x2'.
Condition: Improper/Lack of Maintenance
Due 2 March 2010
Resolved 22 February 2010
Resolution: Deck replaced as required.
Construction/Loadline › Hull › Hull Plating
Issued 22 February 2010 Resolved
Crop and renew area of deck on main deck with marine grade plywood portside outboard side of deck house approximately 6'x2'.
Condition: Improper/Lack of Maintenance
Due 2 March 2010
Resolved 22 February 2010
Resolution: Deck replaced as required.
Construction/Loadline › Hull › Hull Plating
Issued 22 February 2010 Resolved
Crop and renew area of deck on main deck with marine grade plywood portside at the aft of deckhouse approximately 2'x 1 1/2'.
Condition: Improper/Lack of Maintenance
Due 2 March 2010
Resolved 22 February 2010
Resolution: Deck replaced as required.
Construction/Loadline › Hull › Hull Plating
Issued 22 February 2010 Resolved
Crop and renew area of deck on main deck with marine grade plywood starboard outboard side of deck house approx. 7'X2'.
Condition: Improper/Lack of Maintenance
Due 2 March 2010
Resolved 22 February 2010
Resolution: Deck replaced as required.
Construction/Loadline › Hull › Hull Plating
Issued 22 February 2010 Resolved
Crop and renew area of deck on main deck with marine grade plywood starboard at the aft of deckhouse approximately 2'x 1 1/2'.
Condition: Improper/Lack of Maintenance
Due 2 March 2010
Resolved 22 February 2010
Resolution: Deck replaced as required.
Engineering › Bilge Water Management System › Not Operational
Issued 10 April 2008 Resolved
Repair High level bilge alarm in forepeak prior.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2008
Resolved 10 April 2008
Resolution: High Level bilge alarm was repaired in forpeak space.
Lifesaving › Lifefloat › Markings
Issued 22 March 2007 Resolved
Properly label life floats IAW 46 CFR 185.604
Due 22 April 2007
Resolved 17 April 2007
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 22 March 2007 Resolved
Properly attach water lights to floats IAW 180.175
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2007
Lifesaving › Lifefloat › Painter
Issued 22 March 2007 Resolved
Properly attach sea painter to life float IAW 46 CFR 180.137
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 22 March 2007 Resolved
Show proof of crewmember enrollment in drug testing program
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2007
Communications › Radio Communications › EPIRB
Issued 22 March 2007 Resolved
Place EPIRB on board vessel. Vessel is restricted to no more than 3 nm from shore until EPIRB is on board and tested to satisfaction of attending Marine Inspector
Action required: 705 - Other - as specified
Resolved 4 April 2008
Resolution: Installed EPIRB on board the vessel to the satisfaction of the attending Marine Inspector.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 22 March 2007 Resolved
Remove lube oil from bilges
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2007
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 22 March 2007 Resolved
Identify source of diesel fuel leak and remove fuel from bilge. Test/operate Generator to satisfaction of attending marine inspector
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2007
Electrical › Electric Supply System (service) › Battery Charger
Issued 22 March 2007 Resolved
Replace port alternator belt
Due 1 April 2007
Resolved 17 April 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 22 March 2007 Resolved
Replace stbd. transmission hose, and repair mount to avoid future damage to hose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 March 2007 Resolved
Repair engine room high level alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 March 2007 Resolved
Label high level alarm panel to indicate which compartment is sounding the alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2007
Lifesaving › Hand Flares › Expired
Issued 22 March 2006 Resolved
Replace 6 Red and 6 Orange flares prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2006
Resolution: Replaced all flares to the satisfaction of the attending Coast Guard Marine Inspector.
Pollution Prevention/Response › Response Equipment › Sorbents
Issued 22 March 2006 Resolved
Remove oil from Engine room bilge prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2006
Resolution: Removed oil from engine room bilge.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 16 March 2005 Resolved
Provide Current Navigaton pubs (CG Light list, Tides table and Tidal current tables), IAW 46CFR184.20
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 March 2005
Resolved 23 March 2005
Resolution: Purchased current pubs.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 16 March 2005 Resolved
Provide renewed Safety Radio Certificate, vessel is restricted to not more than 1000 feet from shore until safety certificate is renewed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 March 2005
Resolved 25 March 2005
Resolution: Faxed new Safety Radio Certificate.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 16 March 2005 Resolved
Properly stow child size life jackets separate from adults life jackets, IAW 46CFR180.78
Action required: 705 - Other - as specified
Due 30 March 2005
Resolved 23 March 2005
Resolution: Installed seperation betwewn adult and child life jacketes.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 16 March 2005 Resolved
Provide protective guard over alternator on port main engine, IAW 46CFR177.960.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 April 2005
Resolved 23 March 2005
Resolution: Installed protective guard over alternator on port engine.
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 16 March 2005 Resolved
Provide evidence of first aid course completion/CPR card.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 March 2005
Resolved 23 March 2005
Resolution: Provided evidence of first aid and CPR cards.
Engineering › Bilge Water Management System › Not Operational
Issued 16 March 2005 Resolved
Repair Bilge high water level (audio) alarm in crew accommodation space, IAW 46CFR182.530. Vessel is required to visually check bilge in accommodation space prior to and after each voyage, until audio alarm is repaired.
Action required: 705 - Other - as specified
Due 30 March 2005
Resolved 23 March 2005
Resolution: Repaired loose wire for audio alarm.
Lifesaving › Buoyant Apparatus
Issued 4 February 2004 Resolved
Provide new USCG approved weak link for two 15 person Life Floats (46 CFR 180.130)
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2004
Resolved 12 March 2004
Resolution: Procured and installed new/approved weak links for two 15 person life floats.
Operations/Management › Drills/Instruction
Issued 4 February 2004 Resolved
Conduct satisfactory fire and man overboard drills (46 CFR 185.520, 524) LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2004
Resolved 12 March 2004
Resolution: Conducted man underway man overboard and fire drills. All drills satisfactory.
Navigation › Piloting/Steering
Issued 4 February 2004 Resolved
Provide current navigation pubs: Coast Guard Light list, US Coast Pilot, and Tide current tables (46 CFR 184.420) LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 4 March 2004
Resolved 12 March 2004
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 14 January 2002 Resolved
Both Port & Stbd shaft strut bearings were found beyond acceptable wear limits and required renewal. Each shaft has (2) stru bearings and which were renewed.
Condition: Unknown
Due 6 February 2002
Resolved 18 January 2002
Resolution: Bearings renewed
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 January 2002 Resolved
Permanently close two drilled holes in collision bulkhead.
Condition: Unknown
Due 6 February 2002
Resolved 6 February 2002
Construction/Loadline › Structures › Scupper
Issued 14 January 2002 Resolved
Excavate to sound wood and repair decayed area iwo scuppers.
Condition: Improper/Lack of Maintenance
Due 6 February 2002
Resolved 6 February 2002
Resolution: Scuppers repaired
Construction/Loadline › Structures › Scuttle
Issued 14 January 2002 Resolved
Repair inoperable Forepeak scuttle hatch dogs so scuttle can be made watertight.
Condition: Improper/Lack of Maintenance
Due 6 February 2002
Resolved 6 February 2002
Resolution: Hatch repaired.
Lifesaving
Issued 1 March 2001 Resolved
PROVE SERVICING OF EPIRB HYDROSTATIC RELEASE AND REGISTER EPIRB WITH NOAA UNDER PROPER VESSEL NAME. VESSEL RESTRICTED TO NOT MORE THAN 3 MILES FROM SHORE UNTIL THIS IS COMPLETED.
Condition: Unknown
Due 11 March 2001
Resolved 5 March 2001
Navigation
Issued 5 January 2000 Resolved
REPLACE RUDDER CROSS CONNECTION BUSHINGS.
Condition: Unknown
Due 30 January 2000
Resolved 6 January 2000
Navigation
Issued 5 January 2000 Resolved
REPLACE RUDDER BEARINGS.
Condition: Unknown
Due 30 January 2000
Resolved 6 January 2000
Lifesaving
Issued 1 July 1999 Resolved
REPLACE LIFE LINE AND GRAB LINE ON RING BOUY. INSTALL CLIP ON WATER LIGHT LANYARD FOR ATTACHMENT TO RING BOUY.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Electrical
Issued 1 July 1999 Resolved
REMOVE SOLID CORE ROMEX WIRING FROM 110V STYSTEM.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Documentation
Issued 1 July 1999 Resolved
CONDUCT SIMPLIFIED STABILITY TEST, FOR ISSUE OF STABILITY LETTER.
Condition: Unknown
Due 1 July 1999
Resolved 1 July 1999
Engineering
Issued 1 July 1999 Resolved
INSTALL MACHINERY GUARDS OVER STARBOARD ALTERNATOR AND GENERATOR DRIVE BELT.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Documentation
Issued 1 July 1999 Resolved
PROVIDE PROOF OF DRUG TESTING PROGRAM.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Lifesaving
Issued 1 July 1999 Resolved
REPLACE SEA PAINTER CONNECTION EYE, SEA PAINTER AND LIFE LINES ON BOTH LIFEFLOATS.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Construction/Loadline
Issued 1 July 1999 Resolved
MAKE PERMANANT REPAIRS IN WAY OF FR 4 & FR 5 PORT SIDE RUDDER COMPARTMENT BY NEXT DRYDOCK, 31DEC99.
Condition: Unknown
Due 1 July 1999
Resolved 1 July 1999
Fire Fighting
Issued 1 July 1999 Resolved
INSTALL FIXED FIRE FIGHTING AND ALARM SYSTEM IN ENGINE ROOM.
Condition: Unknown
Due 1 July 1999
Resolved 1 July 1999
Lifesaving
Issued 1 July 1999 Resolved
PROVIDE EFFECTIVE SYSTEM FOR RETRIVING MAN OVERBOARD AND BRING VICTIM OVER THE RAIL.
Condition: Unknown
Due 15 August 1999
Resolved 30 August 1999
Electrical
Issued 1 July 1999 Resolved
PERMANTLY MARK ALL BREAKERS AND DISTRIBUTION PANELS WITH SERVICE OR CIRCUIT.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Engineering
Issued 10 March 1999 Resolved
SECURE FUEL OIL LEAKS ON SPARE FUEL OIL STRAINER OR REMOVE STRAINER COMPLETELY TO SECURE FUEL LEAK.
Condition: Unknown
Due 10 April 1999
Resolved 12 March 1999
Engineering
Issued 10 March 1999 Resolved
INSTALL DOUBLE HOSE CLAMPS ON ALL SEA WATER RUBBER HOSES.
Condition: Unknown
Due 10 April 1999
Resolved 12 March 1999
Lifesaving
Issued 1 April 1996 Resolved
PRIOR TO OPERATING WITH MORE THAN 46 PERSON'S, RENEW RETRO TAPE ON 7 ADULT PFD'S TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Construction/Loadline
Issued 14 March 1995 Resolved
BILGE MANIFOLD VALVE FOR SPACE UNDER FUEL TANKS IS BROKEN AND NEEDS TO BE REPLACED.
Condition: Unknown
Due 14 March 1995
Resolved 17 March 1995
Navigation
Issued 14 March 1995 Resolved
ALL CHARTS ARE OUTDATED AND NEED TO BE REPLACED.
Condition: Unknown
Due 14 March 1995
Resolved 17 March 1995
Documentation
Issued 28 April 1993 Resolved
PROVIDE DOCUMENTATIN TO MIO NY OF SATISFACTORY EMPLOYEE ENROLLMENT IN CHEMICAL TESTING PROGRAM.
Condition: Unknown
Due 8 May 1993
Resolved 20 May 1993
Lifesaving
Issued 7 October 1992 Resolved
REPLACE FLOAT FREE LINK ON LIFE FLOAT PAINTER WIH ONE MEETING THE REQUIREMENTS OF 46 CFR 180.15 PRIOR TO SAILING WITH PASSENGERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 October 1992
Resolved 26 October 1992
Navigation
Issued 9 October 1991 Resolved
PROVIDE CURRENT COPY OF NAVIGATION RULES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 October 1991
Resolved 9 October 1991
Electrical
Issued 9 October 1991 Resolved
PROVE PROPER OPERATION OR REMOVE SECONDARY GENERATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 October 1991
Resolved 9 October 1991
Lifesaving
Issued 9 October 1991 Resolved
REPLACE ONE ADULT LIFE PRESERVER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 October 1991
Resolved 9 October 1991
Accommodation/Occupational Safety
Issued 27 July 1990 Resolved
PROVIDE PROPER MEANS OF SECURING MARINE SANITATION DEVICE VALUE IN ENG. ROOM.
Condition: Unknown
Due 27 July 1990
Resolved 27 July 1990
Construction/Loadline
Issued 27 July 1990 Resolved
RENEW AS ORIGINAL, AFT & FWD HATCH COVERS TO ENSURE PROPER WATERTIGHT INTEGRITY, & PROVIDE PROPER WRENCH FOR SECURING BOTH HATCHES.
Condition: Unknown
Due 27 July 1990
Resolved 27 July 1990
Electrical
Issued 26 October 1989 Resolved
RELOCATE STARBOARD BATTERY SWITCH SO THAT IT IS NOT CLOSE ENOUGH TO THE STARBOARD ENGINE ALTERNATOR IR ANY OTHER MOVING MACHINERY TO PRESENT ANY PERSONAL HAZARD.
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Documentation
Issued 16 August 1988 Resolved
PROVIDE A VALID SHIP'S RADIO STATION LICENSE
Condition: Unknown
Due 16 August 1988
Resolved 16 August 1988
Electrical
Issued 16 August 1988 Resolved
REPAIR SWITCH ON STARBOARD BATTERIES
Condition: Unknown
Due 16 August 1988
Resolved 16 August 1988
Electrical
Issued 3 August 1988 Resolved
ELIMINATE ELECTRICAL GROUND IN PORT & STBD DECK LIGHTS WHICH APPEARS WHEN VESSEL IS ON SHORE TIE.
Condition: Unknown
Due 3 August 1988
Resolved 3 August 1988
Construction/Loadline
Issued 12 July 1988 Resolved
MAKE (2) WEATHER DECK HATCH, SECURING DEVICES OPERABLE.
Condition: Unknown
Due 12 July 1988
Resolved 12 July 1988
Construction/Loadline
Issued 12 July 1988 Resolved
REMOVE ALL PLASTIC THROUGH HULL FITTINGS, REPLACE WITH METALLIC AND INSTALLCHECK OR POSITIVE STOP VALVES AS REQUIRED AT NEXT REGULARLY SCHEDULED D/D EXAM.
Condition: Unknown
Due 12 July 1988
Resolved 12 July 1988
Documentation
Issued 12 July 1988 Resolved
PROVIDE A VALID SHIP'S RADIO STATION LICENSE PRESENTLY NOT ONBOARD VESSEL.
Condition: Unknown
Due 12 July 1988
Resolved 12 July 1988
Lifesaving
Issued 12 July 1988 Resolved
PROVIDE (9) NINE ADULT PFD'S WHERE MISSING.
Condition: Unknown
Due 12 July 1988
Resolved 12 July 1988
Engineering
Issued 12 July 1988 Resolved
PROVIDE A SUITABLE HAND OPERABLE FIRE/BILGE PUMP WHICH WILL ENABLE THE COLLISION COMPARTMENT TO BE PUMPED OUT FROM THE MAIN DECK.
Condition: Unknown
Due 12 July 1988
Resolved 12 July 1988
Navigation
Issued 12 July 1988 Resolved
RELOCATE ANCHOR LIGHT TO THE HIGHEST MOST VISIBLE LIGHT ON VESSEL.
Condition: Unknown
Due 12 July 1988
Resolved 12 July 1988
Construction/Loadline
Issued 12 July 1988 Resolved
PROVIDE CAPTIVE CHAIN'S ON 2-WEATHER DECK HATCHES, ONE FWD AND ONE AFT ON MAIN DECK.
Condition: Unknown
Due 12 July 1988
Resolved 12 July 1988
Navigation
Issued 5 August 1987 Resolved
PROVIDE CURRENT CHARTS,COAST PILOT,TIDE AND CURRENT TABLES AND ANY OTHER PUBLICATIONS REQUIRED BY THE OCMI FOR THE VESSEL'S OPERATING ROUTE.
Condition: Unknown
Due 5 August 1987
Resolved 5 August 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.