MAURY USCG vessel records Sign in
← All vessels

VALIANT

VALIANT is a 2001 passenger vessel (inspected). The Coast Guard has recorded 41 inspections since 2001, most recently in February 2026, along with 62 deficiencies — 1 with no resolution recorded —.

Records from 2001 to 2026. Most recent: inspection, 17 February 2026.

Built
2001
Last inspected
17 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8967682 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDG2206
Flag
UNITED STATES
367513250
Maury page id
psix-21161

Inspections, by type

…past their stated due date1
Years with a record 21 calendar years (2001–2026)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)90.0 ft × 20.0 ft × 11.6 ft
Registered tonnagegross 95 / net 63
ITC dimensions (L × B × D)90.0 ft × 20.0 ft × 11.6 ft
ITC tonnagegross 154 / net 61
BuilderMIDSHIP MARINE INC · NEW ORLEANS, LA, UNITED STATES · built 2001
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Convention (Subpart B), Net Ton
63 - Regulatory (Subpart C or D), Net Ton
154 - Convention (Subpart B), Gross Ton
95 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM8349MMSI 367513250 · active · compulsorily equipped · granted 4 March 2022, expires 4 March 2032
WDG2206MMSI 367513250 · expired · compulsorily equipped · granted 22 December 2011, cancelled 26 February 2022
WDA3995MMSI 366804610 · expired · compulsorily equipped · granted 20 March 2001, cancelled 21 May 2011
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 41

17 February 2026 Examination of Repairs · Vessel Attendance · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8312308
13 November 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8256528
20 November 2024 Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8036286
11 April 2024 Appeal
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7894065
18 January 2024 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7847498
18 December 2023 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7837955
2 December 2022 Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7598364
22 March 2022 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7416478
17 November 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7349733
8 October 2020 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7073950
8 January 2020 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6884844
18 December 2019 Drydock Extension
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6876080
25 November 2019 Drydock Extension
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6861800
15 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6834405
27 September 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6827199
26 August 2019 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6794706
1 November 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6572598
30 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6527573
17 November 2017 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6307964
7 November 2017 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6303085
2 September 2016 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5993267
5 May 2016 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5882856
28 October 2015 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5753206
25 September 2015 Drydock Extension
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5728390
1 September 2015 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5232322
19 December 2011 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4210844
22 September 2010 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3854241
21 November 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3105002
16 March 2006 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2603455
1 November 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2526413
7 October 2005 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2509873
10 May 2005 Annual Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2354261
13 May 2004 Plan Review "T" Boat · Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2066296
19 November 2003 Hull Examination · Internal Structural Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1950981
29 April 2003 Annual Inspection · Internal Structural Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1782846
12 September 2002 Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1674581
19 March 2002 Internal Structural Exam · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1600681
13 September 2001 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1362480
13 September 2001 Construction Oversight
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1605263
18 June 2001 Deadweight Survey · Initial Certification · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1450651
11 February 2001 Hull Examination · Construction Oversight
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1361958

Deficiency record · 62

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 November 2025 Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry (1) Six hand red flare distress signals, and (2) Six hand orange smoke distress signals. Vessel had 06 red flares, but only 03 orange flares. Obtain 3 additional orange flares to match vessel route requirements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2025
Resolved 14 November 2025
Resolution: Received objective evidence from operator that 03 new orange flares were acquired and onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 November 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. First-aid kit currently onboard had all expired medicine. Replace with non-expired items.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2025
Resolved 14 November 2025
Resolution: Received objective evidence from operator that new first aid kit was purchased and onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 January 2024 Resolved
A vessel must carry either a first-aid kit approved under 160.041 or a kit with equivalent contents and instructions. The first-aid kits onboard the vessel were past the expiration dates. O/O is to replace expired kits.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2024
Resolved 22 April 2024
Resolution: New first-aid kit was purchased by O/O and is now onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 January 2024 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel's #2 generator air filter had broken off and is no longer attached to engine. O/O is to renew #2 SSDG's prime mover's air filter.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2024
Resolved 22 April 2024
Resolution: New air filter was puchased and installed on #2 generator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 January 2024 Resolved
All electrical equipment, including switches, fuses, lampholders, etc., must be suitable for the voltage and current utilized. Vessel's primary generator was found to have a cartridge style fuse missing from its' holder in the vacinity of the windings housing. O/O is to provide electrical system schematics and if the fuse required; replace IAW approved schematics. 46CFR183.220(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2024
Resolved 22 April 2024
Resolution: O/O provided additional documentation and detailed explanation showing that the fuses for both generators are installed within the switchboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 January 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel's primary generator's electrical windings were found to be excessively dirty, causing a potential fire hazard. O/O is to have the primary generator's windings cleaned and re-inspected to the satisfactory of attending marine inspector. 46 CFR 183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2024
Resolved 22 April 2024
Resolution: Verified both generator's windings were properly cleaned to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 January 2024 Resolved
Wire connectors utilized in conjunction with screw type terminal blocks must be of the captive type such as the ring or the flanged spade type. Vessel's operating station equipment terminal block had unapproved spade type connections which were not of the captive type. O/O is to provide a repair proposal to the OCMI for review and approval, detailing corrective actions to bring the operating station's terminal block connections into compliance. 46 CFR 183.340(k)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2024
Resolved 22 April 2024
Resolution: OCMI approved the repair proposal from O/O dated 11APR24. All spade connections in question will be replaced with approved terminal connections by the vessel's next annual inspection. A special note has been created to reflect this upcoming verification.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 January 2024 No resolution recorded
Controls and valves for operation of fixed gas fire extinguishing system must be: (i) Located outside the space protected by the system; and (ii) Not located in a space that might be inaccessible in the event of fire in the space protected by the system. The fixed suppression system controls (consisting of two 108 cubic inch nitrogen charge bottles, one 30 second time delay bottle, and pressure sensors) are inside the space (engine room) they are meant to protect. These controls must be moved outside of the space. 46 CFR 181.410(b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 January 2024 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 2 December 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Two florescent lights found with no covers in main deck galley. If light bulbs smashed, shards will enter ice machine or possibly start fire from nearby liquor bottles.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2022
Resolved 13 December 2022
Resolution: Light covers replaced with new.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 December 2022 Resolved
All vessels must have navigation lights. Crack in port navigation light housing found.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2022
Resolved 12 January 2023
Resolution: New housing was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 December 2022 Resolved
Each disposable hydrostatic release unit (HRU) must be marked with an expiration date of two years after the date on which the unit is installed. HRU on IBA found expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2022
Resolved 12 January 2023
Resolution: New HRU was installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 December 2022 Resolved
EAP education program must display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Hot-line sticker not found onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2022
Resolved 12 January 2023
Resolution: Hot-line number was posted.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 November 2021 Resolved
Each vessel certificated on LBS in cold water must be provided with life floats of an aggregate capacity of 50% of the total number of persons permitted onboard. IBA not onboard due to servicing. Restricted to 1NM from shore. 46 CFR 180.207(b)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 30 March 2022
Resolution: Operator submitted photos of IBA properly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 17 November 2021 Resolved
Each vessel that operates on the high seas must have on board an accepted Cat. 1, 406 MHz EPIRB, installed to automatically float free and activate. Battery and HRU were expired. Restricted to 3NM from shore. 46 CFR 180.64
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 March 2022
Resolution: Observed new EPIRB battery and HRU unit in place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 November 2021 Resolved
Materials used in vital piping systems must meet the requirements in 46 CFR 182.710. The bilge line from stateroom 2 has a temporary flexible hose near the bilge manifold in the engine room. Repair prior to drydock credit. 46 CFR 182.710
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 March 2022
Resolution: Vsl's engineer explained reason for flex pipe; the valve at the manifold from bilge line was replaced with a ball valve which needed the pipe to be shortened an inch. Flex hose was in good condition w/ double clamps on both ends; permitted to stay.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 November 2021 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. The emergency light in stateroom 1 was not operational.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2021
Resolved 22 March 2022
Resolution: Operator replaced emergency light; observed operation.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 October 2019 Resolved
Each overnight accommodation space on a vessel with overnight accommodations for passengers must be fitted with an independent modular smoke detection and alarm unit that is UL217 approved. Port and stbd aft most overnight accommodations spaces do not have UL217 smoke detectors installed. Install smoke detectors as required. 46CFR181.405(c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 October 2019
Resolved 15 October 2019
Resolution: Vessel rep procured and installed UL217 approved smoke detectors and installed them in required locations.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 15 October 2019 Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by §185.510 of this part and, when applicable, the duties listed in the station bill required by §185.514 of this part. Training conducted on a sister vessel may be considered equivalent to the initial and quarterly training requirements contained in paragraph (a) of this section. Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. 46CFR185.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 22 October 2019
Resolution: Provided with training log and crew member training topic indoc documentation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 October 2019 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Exposed electrical wire found in forward most accommodations space behind modular smoke detector. Remove exposed cable or properly terminate in a electrical enclosure. 46CFR183.340(g)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 22 October 2019
Resolution: Wired properly terminated.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 August 2019 Resolved
Vessels on a Limited Coastwise route must carry six hand red flares and six hand orange smoke distress signals. The vessel is missing 02 hand red flares. Vessel shall only operate on a Lakes, bays and sounds route until this deficiency is corrected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 6 September 2019
Resolution: Vessel had new set of red flares.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 August 2019 Resolved
Fire extinguishers shall be subjected to maintenance at intervals of not more than 01 year as per NFPA 10. The 2-A extinguishers in state rooms #1, #2, 3 and #4 have not been annually serviced since 2017.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 6 September 2019
Resolution: All 2-A extinguishers were serviced.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 August 2019 Resolved
A vessel must carry either a first aid kit approved under 140.041 or equivalent. The vessel's first aid kit is inadequate and does not have all supplies listed in 46CFR160.041.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 6 September 2019
Resolution: New first aid kit was purchased.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 August 2019 Resolved
A portable electric cord or cable must be in compliance with 46CFR111.60-13 for a flexible electric cord or cable. There are extension cords in the Saloon that are not approved under 46CFR111.60-13.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 6 September 2019
Resolution: Crew reconfigured electrical connections in the vacinity of the Saloon.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 26 August 2019 Resolved
Emergency instructions shall be mounted at the operating station. The emergency instructions were not mounted at the operating station.
Action required: 10 - Deficiency Rectified
Due 26 August 2019
Resolved 26 August 2019
Resolution: Crew installed emergency instructions at the operating station during the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 November 2018 Resolved
Each vessel certificated to operate on LBS in cold water must be provided with life floats of an aggregated capacity that will accommodate at least 50% of the total number of persons permitted onboard. IBA off vessel getting serviced. 46CFR180.207(b) Restricted to 1NM from shore
Action required: 705 - Other - as specified
Resolved 26 November 2018
Resolution: Life raft serviced and re-installed
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 1 November 2018 Resolved
The master of the vessel shall ensure that the EPIRB's battery is replaced before the expiration date. Each disposable hydrostatic release must be marked with an expiration date of 2 yrs. EPIRB's battery and hydrostatic release are both expired. 46CFR185.728/46CFR185.740 Restricted to less than 3NM from shore
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 November 2018
Resolution: Vessel replaced battery and hydrostatic with new
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 November 2018 Resolved
Each life ring buoy must be marked clearly legible in block capital letters with the vessel's name. Topside lifebuoy does not have vessel's name marked on it. 46CFR185.604(b) 15NOV2018
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2018
Resolved 26 November 2018
Resolution: Lifebuoy correctly marked
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 November 2018 Resolved
A vessel must carry adequate and up to date charts of large enough scale to make safe navigation, Tide tables and current tables. Missing current tide tables, current tables and charts. 46CFR184.420(1)(4)15NOV2018
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2018
Resolved 26 November 2018
Resolution: Vessel purchased new charts and tables
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 November 2018 Resolved
The master of the vessel shall ensure that EPIRB be tested monthly and shall be logged. No documentation shown for testing and logging monthly EPIRB tests. 46CFR728(a)(c) 01DEC2018
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2018
Resolved 26 November 2018
Resolution: Vessel implimented new log system and logged Nov Epirb testing
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 November 2018 Resolved
All electrical equipment and ciruits must be clearly marked and identified. The bridge breaker panel circuts are incorrectly marked. 46CFR183.220 (d) 15NOV2018
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2018
Resolved 26 November 2018
Resolution: Remarked electrical panels to reflect correct circuits
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 November 2018 Resolved
Each door used as a means of escape must be capble of being opened by one person from either side of the door. Aft doors to main salon do not have means to open doors from outside. 46CFR177.500(h) 15NOV2018
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2018
Resolved 26 November 2018
Resolution: Installed new door handles on the outside of the main salon doors.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 30 August 2018 Resolved
Vsl is broadcasting no IMO # and no static draft information.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 September 2019
Resolution: AIS broadcast info was corrected and vefified by SECTOR Boston
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 17 November 2017 Resolved
The vsl's IBA has been removed for servicing. vsl's operations are limited to no more than one mile from shore until IBA has been restored.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 30 November 2017
Resolution: IBA back in service.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 17 November 2017 Resolved
Provide FCC Safety Radio Certificate and Bridge-to-Bridge Certificate. 47CFR13.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 30 November 2017
Resolution: Documents provided and valid.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 17 November 2017 Resolved
Prove proper operation of emergency lighting in fwd accommodation (berthing) space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 30 November 2017
Resolution: Tested light. All sat.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 2 September 2016 Resolved
Cradle was not permanently attached to vsl.
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 19 September 2016
Resolution: Cradle was permanently mounted the cradle for the IBA using bolts.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 2 September 2016 Resolved
Previous pre-engineered remote activation pulls were still located next to current activation pulls of fixed system.
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 19 September 2016
Resolution: Old pulls were removed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 September 2016 Resolved
Collision blkhd had a pipe theat penetrated the bulkhd and was cut off in the forepeak. Ensure collision bulkhd is watertight. Required to be corrected prior to completion of next credit ddx.
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 7 November 2017
Resolution: Pipe is used for ventillation. Vessel was built with this ventillation design througout vessel which leads to whether decks.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 19 December 2011 Resolved
Provide current FCC Station License, FCC Safety Radio Certificate, and FCC Bridge-to-Bridge Certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 December 2011
Resolution: Received current copies of FCC Station License, FCC Safety Radio Certificate, and FCC Bridge-to-Bridge Certificate.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 22 September 2010 Resolved
Vessel has 10 portable fire extinguishers, all of which have not been serviced since August 2009. Vessel must have all portable extinguishers serviced as required by 46CFR176.810(b).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2010
Resolution: Received a faxed receipt proving service and inspection of all portable extinguishers.
Lifesaving › Lifefloat › Serviceable
Issued 22 September 2010 Resolved
Vessel's starboard side life float has cracks and tears (sun damage) in its body. Life float must be repaired with a manufacturer approved repair kit or replace life float with new. 46CFR808(b)
Action required: 705 - Other - as specified
Due 5 October 2010
Resolved 12 October 2010
Resolution: Vessel properly repaired life float with an approved [name withheld] repair kit.
Lifesaving › Lifefloat › Markings
Issued 22 September 2010 Resolved
The starboard side bottom life float's markings are no longer clearly legible. Vessel must re-mark this life float w/ "22 persons" and the name of the vessel. 46CFR185.604 (a)(2).
Action required: 705 - Other - as specified
Due 5 October 2010
Resolved 12 October 2010
Resolution: Vessel properly marked life float.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 22 September 2010 Resolved
Vessel must provide an updated "US Coast Pilot" and "Coast Guard Light List". Current copies on board date back to 2000. 46CFR184.420
Action required: 705 - Other - as specified
Due 5 October 2010
Resolved 12 October 2010
Resolution: Vessel purchased and placed onboard new 2010 US Coast Pilot & USCG Light List and updated paper charts.
Construction/Loadline › Hull › Weld
Issued 21 November 2007 Resolved
Reweld aft Port side A/M
Action required: 705 - Other - as specified
Resolved 21 November 2007
Resolution: Vessel made proper repairs.
Construction/Loadline › Hull › Weld
Issued 21 November 2007 Resolved
P/U weld Port side bow a/m
Action required: 705 - Other - as specified
Resolved 21 November 2007
Resolution: Made proper repairs.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 16 March 2006 Resolved
Prove proper operation of secondary generator shutdown from FFF system
Due 15 April 2006
Resolved 20 September 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 16 March 2006 Resolved
Lock MSD sewage discharge
Due 15 April 2006
Resolved 20 September 2007
Construction/Loadline › Hull › Transverse Frame
Issued 16 March 2006 Resolved
Install limber holes b/n stateroom 2 and 3
Due 15 April 2006
Resolved 20 September 2007
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 16 March 2006 Resolved
Provide current copy of FCC safety cert.
Due 15 April 2006
Resolved 20 September 2007
Lifesaving › Rescue Boat › Capacity
Issued 16 March 2006 Resolved
Label lrescue boat with capacity.
Due 15 April 2006
Resolved 20 September 2007
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 1 November 2005 Resolved
Replace one electric outlet in e/r with approved type.
Due 15 November 2005
Resolved 15 November 2005
Resolution: Completed.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 1 November 2005 Resolved
Mark outside of both e/r deck hatches with emergency exit signage.
Due 15 November 2005
Resolved 15 November 2005
Resolution: Completed.
Communications › Radio Communications › EPIRB
Issued 10 May 2005 Resolved
EPIRB hydrostatic release had expired dates punched out on the tag, but O/O said he would fax receipt that the EPIRB was just purchased.
Due 26 May 2005
Resolved 7 October 2005
Resolution: Fax from O/O of proof of purchase of new hydro-release for EPIRB.
Electrical › Electric Generation Source (service)
Issued 13 May 2004 Resolved
USCG marine inspector to conduct as-built verification for new 20kw genset installation as per approved plans. LEGACY COMPONENT DESC: Generator
Due 31 May 2004
Resolved 18 May 2004
Resolution: Conducted as-built verification and tested genset with a load (sat).
Fire Fighting › Means of Escape
Issued 19 November 2003 Resolved
Label escape route (x2) from engine room. LEGACY COMPONENT DESC: Escape Route Signs
Condition: Unknown
Due 15 December 2003
Resolved 18 May 2004
Resolution: Complete.
Construction/Loadline
Issued 18 June 2001 Resolved
Replace swingbolt in port light in stateroom #4
Condition: Unknown
Due 6 August 2001
Resolved 7 August 2001
Fire Fighting
Issued 18 June 2001 Resolved
Arrange E/R fixed extinguishing system so that discharge will shut down power ventilation
Condition: Unknown
Due 6 August 2001
Resolved 7 August 2001
Engineering
Issued 18 June 2001 Resolved
Install protection for fuel tank sight glasses
Condition: Unknown
Due 2 July 2001
Resolved 6 July 2001
Navigation
Issued 18 June 2001 Resolved
Modify steering machinery to comply with 46 CFR 182.61 - (b), (f)(1), (f)(2), (f)(3), (g)(1)
Condition: Unknown
Due 6 August 2001
Resolved 7 August 2001
Engineering
Issued 18 June 2001 Resolved
Install electrical bond on stbd fuel tank fill pipe
Condition: Unknown
Due 2 July 2001
Resolved 6 July 2001
Navigation
Issued 18 June 2001 Resolved
Provide written instruction for transferring from main steering to auxiliary steering.
Condition: Unknown
Due 6 August 2001
Resolved 7 August 2001
Accommodation/Occupational Safety
Issued 18 June 2001 Resolved
Fit stove with sea rails
Condition: Unknown
Due 6 August 2001
Resolved 7 August 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.