MAURY USCG vessel records Sign in
← All vessels

NAVIGATOR PLUTO

NAVIGATOR PLUTO is a 1999 tank ship. The Coast Guard has recorded 17 inspections since 2001, most recently in May 2026, along with 2 deficiencies and 5 operational controls.

Records from 2001 to 2026. Most recent: inspection, 15 May 2026.

Built
1999
Last inspected
15 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9177571 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
LIBERIA
—
Maury page id
psix-21202

Inspections, by type

…with no type recorded5
Years with a record 9 calendar years (2001–2026)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it5352 - Regulatory (Subpart C or D), Net Ton
5352 - Convention (Subpart B), Net Ton
23484 - Dead Weight, Ton
33021 - Displacement, Ton
17840 - Regulatory (Subpart C or D), Gross Ton
17840 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

15 May 2026 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8375623
17 February 2026 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8310419
12 May 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8133286
18 March 2025 COC-GAS Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8092788
30 January 2024 PSC B · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7856560
6 January 2023 PSC B · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7617424
23 August 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7541832
4 January 2022 Ballast Water Examination · PSC B · Administrative Inspection · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7375694
14 August 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2468008
9 August 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2457144
6 August 2005 COC-GAS Renew · ISPS III Exam · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2453331
5 August 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2459675
23 August 2004 Ballast Water Examination · ISPS II Exam · COC-GAS Annual
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2174729
8 May 2003 Certificate of Compliance · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1789380
7 May 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1788880
28 January 2001 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 286268
26 January 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1382138

Deficiency record · 2

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 January 2023 Resolved
Administration should take appropriate steps to ensure uniformity in the implementation and application of the provisions of this chapter in respect to electrical installations. Several cargo tank electric motors and light fixtures are compromised due to improper installation and corrosion
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 9 April 2023
Resolved 28 March 2023
Resolution: All compromised electrical installations renewed as original.
Navigation › Piloting/Steering › Gyro Compass
Issued 9 August 2005 Resolved
Recieved inbound deviation request due to inoperable echo depth sounder.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2005
Resolution: Recieved tech report attesting to the repair of the Gyro Compass.

Ownership record