MAURY USCG vessel records
← All vessels

DELPHINUS

DELPHINUS is a 1997 freight ship. The Coast Guard has recorded 26 inspections since 2016, most recently in October 2022, along with 36 deficiencies and 12 operational controls.

Records from 2016 to 2022. Most recent: inspection, 18 October 2022.

Built
1997
Last inspected
18 October 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 October 2022
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9137844
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-21206

Documentation record

Tonnage as PSIX records it2759 - Convention (Subpart B), Net Ton
6911 - Dead Weight, Ton
10309 - Displacement, Ton
5730 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 26

18 October 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7579768
1 March 2022 PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7403406
25 October 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7339294
23 September 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7355613
15 September 2021 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7312986
5 July 2021 PSC A · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7244692
27 June 2021 PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7235654
30 May 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7210084
27 May 2021 Deficiency Check · PSC A · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7207226
13 February 2021 Deficiency Check · PSC B · ISM Exam · In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7139182
16 December 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7112736
9 August 2020 PSC B · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7028207
24 March 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6931030
25 January 2020 Deficiency Check · PSC B · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6894554
19 July 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6755555
25 May 2019 MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6696228
18 January 2019 Administrative Inspection · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6612190
4 January 2019 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6605702
30 December 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6603822
20 September 2018 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6547045
21 June 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6451131
3 December 2017 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6315624
24 October 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6294251
2 May 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5867398
30 March 2016 In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5843934
25 February 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5821650

Deficiency record · 36

07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 July 2021 Resolved
The purpose of this regulation is to contain a fire in the space of origin. The ship shall be subdivided by thermal and structural boundaries. PSCOS discovered a hole in the overhead fire boundary in the HVAC room. 74 Solas (04) II-2/9.1.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2021
Resolved 11 July 2021
Resolution: Inspector that cleared this Def on 11JUL21 per the provided copy of the form B from master noting the def had been cleared on the specified date needs to replace info in this block.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 5 July 2021 Resolved
Manholes and flush scuttles... shall be closed by substantial covers capable of being made watertight. The scape hatch from the welding shop is leaking rain water into the space due to missing nuts. Deficiency rectified on the spot. ICCL (88) 18(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2021
Resolved 6 July 2021
Resolution: Crew added missing nuts to cover, stopping water from coming into the space.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 27 June 2021 Resolved
Doors fitted in boundary bulkheads of machinery spaces of category "A" shall be reasonably gas tight and self-closing... the starboard, forward lower-engineroom escape door and the door leading to the air conditioning room was unable to close. 74 SOLAS (97) II-2/47.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 27 June 2021
Resolved 27 June 2021
Resolution: Received class report rectifying deficiencies.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 June 2021 Resolved
A special alarm operated from the navigation bridge or fire control station shall be fitted to summon the crew... no audible alarm sounded on emergency generator deck. 74 SOLAS (97) II-2/40.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 June 2021
Resolved 27 June 2021
Resolution: Received class report rectifying deficiencies.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 2 June 2021 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Due to the objective evidence in the above deficiencies, the vessel is not in substantial compliance with relevant conventions, calling into question the adequacy and implementation of the vessel’s SMS under the ISM code. Despite completing an ISM audit on 03/11/2021, PSCOs collected objective evidence that the vessel is submitting requests to the company for maintenance and repair support, but could not find evidence of the company taking actions to support the these requests. Requested repairs include CO2 lines and cargo fixed securing devices on deck. In all cases, the vessel could not produce evidence that the vessel or company notified their Recognized Organization or Flag Administration of the serious safety deficiencies. An external audit conducted by the Flag or RO is required within 30 days to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the completed audit report to USCG prior to departure from port. 74SOLAS (14) IX/3.1 ISM Code Part A/10.1
Action required: 30 - Ship detained
Resolved 12 June 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 June 2021 Resolved
The piping for the distribution of fire-extinguishing medium shall be arranged and discharge nozzles so positioned that a uniform distribution of medium is obtained. PSCOs identified holes in the CO2 line leading to cargo hold 3 and excessive wastage of the CO2 line leading to cargo hold 2. 74SOLAS (97) II-2/5.1.3
Action required: 30 - Ship detained
Resolved 12 June 2021
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Lashing material
Issued 2 June 2021 Resolved
Cargo and cargo units carried on or under deck shall be loaded, stowed and secured as to prevent as far as is practicable, throughout the voyage, damage or hazard to the ship and the persons on board, and loss of cargo overboard… PSCOs observed excessive wastage of multiple fixed cargo securing devices (lashing plates) on deck and multiple devices were cracked and bent. 74SOLAS (97) VI/5.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 13 February 2021 Resolved
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material…such covers shall be weathertight and fitted with gaskets and clamping devices. The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration… During the deck walk PSCOs identified multiple areas of excessive corrosion and wastage that caused holes on the cargo hatch covers and on the sides of the cargo holds; compromising their structural strength and weathertight integrity. PSCOs observed light through the hatch covers in every cargo hold. ICLL 88 Reg. 16(1)
Action required: 30 - Ship detained
Resolved 25 May 2021
Resolution: Class report received attesting repairs.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 13 February 2021 Resolved
Openings in freeboard decks other than hatchways, machinery space openings, manholes and flush scuttles shall be protected by an enclosed superstructure, or by a deckhouse or companionway of equivalent strength and weathertightness… PSCOs observed wasted edge and gasket on the watertight door for the paint locker leading below the freeboard deck. After further inspection, PSCOs observed excess light through the watertight door while in the closed position. ICLL 88 Reg. 18(2)
Action required: 30 - Ship detained
Resolved 25 May 2021
Resolution: Class report received attesting repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 13 February 2021 Resolved
Except as provided in paragraph (3), ventilator openings shall be provided with watertight closing appliances of steel or other equivalent material. In ships of not more than 100 m in length the closing appliances shall be permanently attached; where not so provided in other ships, they shall be conveniently stowed near the ventilators to which they are to be fitted… PSCOs observed excessive corrosion and wastage on the cargo hold ventilators rendering them inoperable. Ventilators requiring portable covers were missing completely. ICLL 88 Reg. 19(4)
Action required: 30 - Ship detained
Resolved 25 May 2021
Resolution: Class report received attesting repairs.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 13 February 2021 Resolved
Where frames or beams pass through a watertight deck or bulkhead, such deck or bulkhead shall be made structurally watertight without the use of wood or cement… PSCOs observed significant damage in the hull, frames, and deck plating on the starboard quarter in the air conditioning system space. PSCOs observed separation between the sideshell and deck plating with an ineffective and unapproved temporary concrete repair. 74 SOLAS (97) II-1/14.2.2
Action required: 30 - Ship detained
Resolved 9 March 2021
Resolution: Class attested to repair being authorized and not temporary. Deficiency rectified.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 13 February 2021 Resolved
A forepeak or collision bulkhead shall be fitted which shall be watertight up to the bulkhead deck… PSCOs observed open forepeak tank cover and missing fixed securing bolts; eliminating the watertight integrity of the compartment. 74 SOLAS (97) II-1/10.1
Action required: 30 - Ship detained
Resolved 9 March 2021
Resolution: New bolts and nuts installed, deficiency rectified.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 13 February 2021 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Due to the objective evidence in the above deficiencies, the vessel is not in substantial compliance with relevant conventions, calling into question the adequacy and implementation of the vessel’s SMS under the ISM code. PSCOs collected objective evidence that the vessel is submitting requests to the company for maintenance and repair support, but could not find evidence of the company taking actions to support the these requests. In all cases, the vessel could not produce evidence that the vessel or company notified their Recognized Organization or Flag Administration of the serious safety deficiencies. An external audit conducted by the Flag or RO is required within 30 days to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the completed audit report to USCG prior to departure from port. 74 SOLAS (14) IX/3.1 ISM CODE PART A/10.1
Action required: 30 - Ship detained
Resolved 10 March 2021
Resolution: Audit report received.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 February 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board… PSCOs observed numerous cracks and holes in the starboard side hull rub rails resulting in excessive corrosion along the side of the vessel. 74 SOLAS (97) I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2021
Resolution: Vessel rub rails welded to the satisfaction of class, deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 February 2021 Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution, and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board…PSCOs observed excessive fuel oil leak originating from fuel transfer pump into a fixed containment, the pump housing accumulated approximately an inch of fuel, creating a fire risk. 74 SOLAS (97) II-2/15.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2021
Resolution: Vessel installed new o rings and fittings to resolve fuel leak, deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 13 February 2021 Resolved
On all ships, within the machinery spaces, emergency escape breathing devices shall be situated ready for use at easily visible places… The vessel is required six EEBD’s. PSCOs found two EEBDs completely exhausted and two expired EEBDs. 74 SOLAS (14) II-2/13.4.3.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2021
Resolution: EEBDs have been serviced and recharged, suficient quantity verified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 February 2021 Resolved
Every lifebuoy shall be fitted with a grabline not less than 9.5 mm in diameter and not less than four times the outside diameter of the body of the buoy in length. The grabline shall be secured at four equidistant points around the circumference of the buoy to form four equal loops… PSCOs observed multiple lifebouys with improper and dry rotted grablines. 74 SOLAS (97) III/31.1.8
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2021
Resolution: Vessel installed new grab lines on worn rings as well as purchasing new life bouys to replace older.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 13 February 2021 Resolved
Such certificate shall be issued or endorsed as appropriate either by the Administration for by any persons or organization duly authorized by it. The IOPP Supplement lists the incorrect Oil Content Meter (OCM). The onboard OCM complies with MEPC.60 but is listed as complying with MEPC.107 on the IOPP Supplement. MARPOL 17 1/7.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 March 2021
Resolution: New IOPP supplement issued reflecting compliance with MPEC 60.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 February 2021 Resolved
Cylinders must always be secured and, when not in use, they must be stored in a rack in an upright position, with the valve protection cap in place… PSCOs observed 10 oxygen and acetylene bottles stored together on the main deck. 46 CFR 147.60(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2021
Resolution: Vessel to remove excess bottles not being used for additional repairs. Remaining bottles stored properly.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 25 January 2020 Resolved
All Ships 3,000 gross tonnage and upward shall in addition to meeting the requirements have ... a 3 GHxz radar or... a second 9 GHz radar...which are functionally independent. The X-Band Radar is non operational Solas Cons 2014 V 19.2.7.1 15ac
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Due 30 January 2020
Resolved 17 February 2020
Resolution: Received class report from vessel company representative attesting to proper operation of x-band radar.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 July 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board; motor for air conditioning is excessively leaking in engine room
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 August 2019
Resolved 4 August 2019
Resolution: Replaced fan on motor
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 19 July 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board; lagging in purifier space are soaked with oil creating a fire hazard
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 August 2019
Resolution: Lagging in purier space has been replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 20 January 2019 Resolved
The construction and means for securing the weather tightness of cargo and other hatchways. Shall be at least equivalent to. the requirements of regulations 15 and 16 of this annex. PSCO observed 03 quarter sized holes in the steel of the cargo hatch cover. These holes allow for the passage of water into the hold below. ICLL 66 ANNEX I/14(1). 16A
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2019
Resolved 3 February 2019
Resolution: Recieved Class report from Rina stating isolated holes were repaired (see documents).
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 20 January 2019 Resolved
The I.L.L.C shall not be delivered to the ship until the officer or surveyor...has certified that the marks are correctly and permanently indicated on the ships sides. The Load line affixed to the hull does not match the issued certificate. ICLL 66 Annex I/9 16a
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2019
Resolved 3 February 2019
Resolution: Recieved Class report stating new ILLC issued to vessel. Also recieved copy.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 January 2019 Resolved
Nautical charts...shall be adequate and up to date. Chart was improperly corrected and is unusable for Lake Worth area 74 SOLAS (14CONS) CH.V/REG 27 16A
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2019
Resolved 3 February 2019
Resolution: Received Class report stating new charts were supplied to the vessel.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 30 December 2018 Resolved
OBJECTIVE EVIDENCE DISCOVERED DURING AN EXPANDED ISM EXAM REVEALED THE FOLLOWING NON-CONFORMITIES: THE VESSEL FAILED TO FULLY IMPLEMENT THE REQUIREMENTS OF THE ISM CODE THROUGH THEIR SMS PROCEDURES AS EVIDENT BY THE FOLLOWING DEFICIENCIES INDICATING THAT THE SHIP AND/OR COMPANY ARE NOT MEETING THE SMS REQUIREMENTS. RECOMMEND AN EXTERNAL AUDIT. 1) THE COMPANY SHOULD IDENTIFY EQUIPMENT AND TECHNICAL SYSTEMS THE SUDDEN OPERATIONAL FAILURE OF WHICH MAY RESULT IN HAZARDOUS SITUATIONS. THE SAFETY MANAGEMENT SYSTEM SHOULD PROVIDE FOR SPECIFIC MEASURES AIMED AT PROMOTING THE RELIABILITY OF SUCH SYSTEMS OR EQUIPMENT. DURING ROUTINE MAINTENANCE, FIRE MAIN VALVE WHICH SUPPLIES WATER TO SUPERSTRUCTURE HYDRANTS WAS SECURED. REST OF CREW WAS NOT INFORMED OF NON-AVAILABILITY OF FIREFIGHTING WATER DURING THIS TIME. PERFORMANCE OF MAINTENANCE OF VALVE PREVENTS "TECHNICAL PREPAREDNESS OF SHIP FOR POSSIBLE EMERGENCY SITUATIONS, EFFECTIVE DAMAGE CONTROL AND RENDERING ASSISTANCE TO PEOPLE AND SHIPS IN DISTRESS AT SEA", PER VESSEL'S SMS PROCEDURE. 74 SOLAS (14 CONS) IX/3.1 ISM CODE PART A 10.3 30AC, REDUCED TO 16AC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 30 December 2018
Resolved 13 January 2019
Resolution: Vessel submitted external audit done by RINA.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 December 2018 Resolved
FIRE EXTINGUISHING APPLIANCES SHALL BE KEPT IN GOOD ORDER AND BE AVAILABLE FOR IMMEDIATE USE. DURING TESTING OF MAIN AND EMERGENCY FIRE PUMPS, SECOND OFFICER WAS UNABLE TO UTILIZE FIRE HOSES/HYDRANTS IN THE SUPERSTRUCTURE DUE TO CLOSED VALVES. SHIP'S CREW AS UNABLE TO IDENTIFY AND RECTIFY CAUSE FOR AN HOUR. 74 SOLAS (97) II-2/21 30AC,REDUCED TO 10C
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 30 December 2018
Resolved 30 December 2018
Resolution: Valve was ultimately discovered, opened, and fire pumps were determined to operate properly.
Pollution Prevention/Response › Response Equipment › Protective Clothing
Issued 27 October 2017 Resolved
0810-Personal Equipment-Four sets of full protective clothing resistant to chemical attack shall be provided. Vessel carried only three sets of chemical resistant clothing. 74 SOLAS (97 Cons) II-2/54.2.6.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2017
Resolution: Vessel purchased an additional chemical suit.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 27 October 2017 Resolved
2500-ISM-Objective evidence discovered during an expanded ISM exam revealed numerous non-conformaties. Detailed description is contained in narrative. 74 SOLAS (14 Cons)IX/3.1 ISM Code Part A
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 30 October 2017
Resolution: Received Audit results from RINA.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 25 October 2017 Resolved
In a ship which fuel oil is used, the arrangements for the storage, distribution, and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. Excessive oil accumulation in multiple areas throughout the engine room. 74SOLAS(1997 cons.)II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 30 October 2017
Resolution: Engine spaces thoroughly cleaned and scrubbed of oil residue.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 25 October 2017 Resolved
The fire control plan shall show clearly for each deck the control stations, the various fire sections enclosed by class A divisions. Multiple class A fire doors would not close properly and class A fire door on poop deck was missing, thus compromising fire boundary integrity. 74SOLAS(1997 cons.)II-2/20.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 30 October 2017
Resolution: Fire doors adjusted to ensure proper closure.
Fire Fighting › Means of Escape › Doorways
Issued 25 October 2017 Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gas tight and self closing. Lower engine room emergency escape door would not close. 74SOLAS(1997 cons.)II-2/47
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 25 October 2017 Resolved
Every liferaft shall be stowed with its painter permanently attached to the ship in a float free arrangement. Port side liferaft not secured to weak link, liferaft not in a float free arrangement. 74SOLAS(1997 cons.)III/29
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2017
Resolved 30 October 2017
Resolution: Hydrostatic release for liferaft correctly attached to ensure release.
Documentation › Markings/Placards › Hull Identification Number (HIN)
Issued 25 October 2017 Resolved
The ships identification number shall be permanently marked in a visible place. Vessel's IMO number is painted and not permanently marked. 74SOLAS(2014 cons.)XI-1/3
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 30 October 2017
Resolution: Vessel IMO number permanently welded to bulkhead in engine room.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 31 March 2016 Resolved
1410 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to sea without danger to the ship or persons on board. The turbocharger on the main engine suffered a casualty resulting in a reduction of propulsion. 74SOLAS(14) CH.I/Reg.11a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2016
Resolution: Class Report
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 1 March 2016 Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored even though one of the essential auxialiaries becomes inoperable.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 8 March 2016
Resolution: Repairs conducted vessel's class submitted survey report clearing main engine issue./

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.