MAURY USCG vessel records Sign in
← All vessels

RIVER DOG

RIVER DOG is a 2000 passenger vessel (inspected). The Coast Guard has recorded 6 inspections since 2001, most recently in July 2006, along with 3 deficiencies.

Records from 2001 to 2006. Most recent: inspection, 11 July 2006.

Built
2000
Last inspected
11 July 2006
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-21213

Inspections, by type

…with no type recorded2
Years with a record 5 calendar years (2001–2006)
The 6 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.0 ft × 15.3 ft × 4.3 ft
Registered tonnagegross 7 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGERALD H ANDERSON · GREEN COVE SPRINGS, FL, UNITED STATES · built 2000
Hull materialFRP (Fiberglass)
PropulsionGasoline Engine
Hull shapeShip
Hull configurationTri Hull
Hailing portJACKSONVILLE, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 10 August 2004 · expires 31 August 2005
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 6

11 July 2006 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2709108
4 June 2004 Annual Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2087669
19 May 2003 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1796459
4 April 2002 Periodic Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1600883
7 December 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1417423
11 April 2001 Initial Certification · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1432467

Deficiency record · 3

Construction/Loadline › Penetrations › Pipe Flange
Issued 4 June 2004 Resolved
Vessel inspection ports found wasted, PVC caps only being held with two theads
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 15 July 2004
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 4 June 2004 Resolved
Blind Spot found approx 13 ft fwd from operating station
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 15 July 2004
Construction/Loadline
Issued 11 April 2001 Resolved
VESSEL OWNER IS REQUIRED TO PROVIDE ADDITIONAL INFORMATION CONCERNING THE CONSTRUCTION OF THE PONTOONS. THE ADDITIONAL INFORMATION SHOULD INCLUDE RESIN CONTENT & TENSILE STRENGTH. IF THIS INFO CANNOT BE OBTAINED, THE OWNER MUST USE AN INDEPENDENT LAB TO PROVIDE RESULTS.
Condition: Unknown
Due 13 April 2001
Resolved 13 April 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.