Records from 1995 to 2026. Most recent: inspection, 20 May 2026.
Inspection history · 63
20 May 2026
Vessel Attendance · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8377678
11 May 2026
COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8361353
12 March 2026
Internal Structural Exam · Hull Examination · Vessel Attendance · Drydock Extension
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8319108
21 April 2025
Examination of Repairs · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8116360
21 November 2024
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8042187
15 July 2024
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7959050
7 September 2023
Internal Structural Exam · Drydock Exam · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7787759
14 July 2022
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7506627
14 April 2021
MTSA Verification · COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7174724
2 March 2021
Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7149181
23 November 2020
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7100555
13 July 2020
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7005972
6 May 2019
MTSA Verification · In-Service Inspection · Examination of Repairs · Periodic Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6678289
7 June 2018
Internal Structural Exam · Examination of Repairs · Annual Inspection · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6437196
7 March 2018
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6367825
9 February 2018
Damage Survey
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6355288
24 March 2017
Examination of Repairs · MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6111161
10 January 2016
Internal Structural Exam · MTSA Verification · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5792766
23 July 2015
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5792008
3 February 2012
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4237851
24 November 2010
Hull Examination · MTSA Verification · Internal Structural Exam · COI Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3923900
7 December 2009
COI Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3645759
4 September 2008
Plan Review (Other than "T") · Deficiency Check · Periodic Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3309304
21 April 2008
Examination of Repairs
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3200095
25 March 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3171016
25 March 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3171038
14 March 2008
Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3169354
12 February 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3170369
19 October 2007
Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3117126
7 February 2006
COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2580713
22 December 2004
Annual Inspection · MTSA Verification
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2263616
30 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1998583
18 December 2003
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1966343
17 October 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1932955
12 April 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1779695
27 September 2002
Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1679617
26 October 2001
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1425233
25 July 2001
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1070933
23 July 2001
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1069289
8 May 2001
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1464376
19 January 2001
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1057580
3 January 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 147873
12 October 2000
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1054676
18 September 2000
COI Inspection · Hull Examination · Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1369830
13 July 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451576
21 October 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 800857
8 July 1999
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 778934
7 July 1999
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1457669
1 July 1999
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1437579
24 August 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 797311
17 July 1998
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1433362
20 January 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 778105
23 October 1997
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 52058
23 October 1997
Damage Survey · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1428867
30 June 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404404
26 June 1997
Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1433220
23 June 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1114752
20 November 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 534421
17 October 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 396499
7 June 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448786
7 September 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 159148
18 August 1995
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 106744
23 June 1995
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422524
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 May 2026
Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such test or inspections as he or she deems necessary to be assured of the safety and seaworthiness of the vessel.
Port and stbd after legs 10 year not completed IAW CG-543 Policy Letter 07-02. 10 year shall be completed prior to operations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2026
Resolved 9 June 2026
Resolution: Vessel completed 10 year leg credit on Port & Stbd aft legs. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 21 April 2025
Resolved
After any survey of the vessel made under 42.09-25 to 42.09-40, inclusive, as applicable, has been completed and deficiencies corrected as provided, no change shall be made in the vessel's structure, equipment, arrangement, material, or scantlings as covered by such survey, without the prior specific approval of the assigning and issuing authority.
Vessel failed to notify class of repairs and hull replacement prior to commencing work. Vessel will need to send repair plan to class for approval, and then request acceptance of repairs already completed
Cite: 46CFR42.09-50(a)
Action: 701ac
Def code 01108
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2025
Resolved 13 June 2025
Resolution: Vsl provided RO approval and new Load Line Cert.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 July 2024
Resolved
Each portable fire extinguisher approved under subpart 162.028 of this chapter and each semi-portable fire extinguisher approved under subpart 162.039 of this chapter must be installed in compliance with Table 132.220 of this section.
The following spaces are missing proper portable fire extinguishers (PFEs): Galley does not have a 40-B:C PFE, and the Paint Locker does not have a 40-B PFE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2024
Resolved 10 September 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 July 2024
Resolved
Each vessel of 100 or more gross tons, or 19.8 meters (65 feet) or more in length, must have navigational lighting in compliance with the applicable navigation rules and with § 111.75-17(d) of this chapter.
Port and starboard navigation lights are deteriorated, not in proper working order and must be certified by an independent laboratory to the requirements of ANSI/UL 1104 or EN 14744 (incorporated by reference; see § 110.10-1 of this subchapter) or an equivalent standard under § 110.20-1 of this subchapter and must be labeled as such.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2024
Resolved 10 September 2025
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 15 July 2024
Resolved
Each lighting fixture in an electrical system operating at more than 50 volts must comply with UL 595, “Marine Type Electric Lighting Fixtures.” A lighting fixture in an accommodation space, radio room, galley, or similar interior space may comply with UL 57, “Electric Lighting Fixtures,” UL 1570, “Fluorescent Lighting Fixtures,” UL 1571, “Incandescent Lighting Fixtures,” UL 1572, “High Intensity Discharge Lighting Fixtures,” UL 1573, “Stage and Studio Lighting Units,” or UL 1574, “Track Lighting Systems,” as long as the general marine requirements of UL 595 are satisfied.
Light fixtures in state rooms #8 & #9 are missing the required shields.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 April 2021
Resolved
Each vessel must undergo dry dock examinations as follows: vessels that operate in salt water must be examined IAW Table 91.40-3(a) of this section. A single hull ship must be examined at a 2.5 year examination interval, which means it must undergo two examinations within any five years period. No more than three years may elapse between any two examinations. Marine Inspectors confirmed with vessel operator that their dry dock date was set for 07JAN2021, but the vessel did not go into dry dock until 22JAN2021.
Action required: 10 - Deficiency Rectified
Due 14 April 2021
Resolved 14 April 2021
Resolution: The vessel went into dry dock on 22JAN2021 and Marine Inspectors conducted a sat inspection of the hull/appendages/through hull fittings.
Construction/Loadline › Hull › Bottom Plating
Issued 9 February 2018
Resolved
pin hole leak in way of bottom plate approx two inchs aft of port fuel tank
Action required: 705 - Other - as specified
Due 24 April 2018
Resolved 7 June 2018
Resolution: Verifed proper plate insert to hull bottom with sat NDT.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 9 February 2018
Resolved
pin hole leak in starboard fuel tank at weld seam located at aft bulk head and bottom plate
Action required: 705 - Other - as specified
Due 24 April 2018
Resolved 7 June 2018
Resolution: MI verified proper insert and sat NDT to bulkhead iwo starbord fuel tank.
Engineering › Bilge Water Management System › Piping
Issued 7 April 2016
Resolved
Noted bilge discharge pipe in the stbd engine room had a soft patch temp repair. Make proper repairs to holed bilge discharge pipe located in the stbd engine room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 12 April 2016
Resolution: Bilge discharge pipe repaired and test satisfactory.
Accommodation/Occupational Safety › Ventilation › General
Issued 7 April 2016
Resolved
Eliminate potential fire hazard. Clean all excessive cooking grease in the galley grill's hood smoke extract fan and ducking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 12 April 2016
Resolution: Hood, fan and assosicated ducking was cleaned. All Sat.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 7 April 2016
Resolved
Reposition emergency light fixture to provide illumination to the escape route from the engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 24 March 2017
Resolution: MIs verified proper positioning of E-light.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 7 April 2016
Resolved
Conduct man overboard drills and prove rescue boat can be deployed and operated in a timely manner. Outboard engine could not be operated during drill.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 12 April 2016
Resolution: Satisfactory man overboard drill conducted.
Engineering › Pressure Vessel › Relief Valve
Issued 10 January 2011
Resolved
Replace Pressure Relief Valve on Air Recievers IAW NVIC 8-91 (46 CFR 54.03)
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 January 2011
Resolved 14 January 2011
Resolution: Inspected and tested pressure relief valves
Lifesaving › Lifefloat › Capacity
Issued 24 November 2010
Resolved
Vessel will carry 36 persons due to 3 lifefloats at 12 persons IAW NVIC 8-91 [46 CFR 133.105(c)]
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 January 2011
Resolved 14 January 2011
Resolution: Added 1 12 person life float
Lifesaving › Lifefloat › Float-free Link
Issued 7 December 2009
Resolved
Under sized weak link installed.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2009
Resolution: Proper weak link installed
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 7 December 2009
Resolved
Tachometer not operational for the Center MDE
Condition: Unknown
Due 17 December 2009
Resolved 9 December 2009
Resolution: New sending unit installed
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 7 December 2009
Resolved
Remote shut down for center MDE does not work.
Condition: Improper/Lack of Maintenance
Due 17 December 2009
Resolved 9 December 2009
Resolution: New strker plates installed
Electrical › Lighting (service) › Switch
Issued 7 December 2009
Resolved
Loose wire for deck light switch located in the galley.
Condition: Improper/Lack of Maintenance
Due 17 December 2009
Resolved 7 December 2009
Resolution: Wire was secured properly.
Lifesaving › Lifebuoys › Serviceable
Issued 7 December 2009
Resolved
Plastic seam was coming off.
Condition: Improper/Lack of Maintenance
Due 17 December 2009
Resolved 7 December 2009
Resolution: Ringbuoy was replaced with another one.
Electrical › Electric Generation Source (emergency) › Metallic Enclosure/Frame
Issued 2 January 2009
Resolved
Permanently secure battery box to deck located on flying bridge.
Action required: 705 - Other - as specified
Due 2 February 2009
Resolved 9 January 2009
Lifesaving › Lifefloat › Painter
Issued 2 January 2009
Resolved
Properly configure life floats to sea painter and weak link.
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 9 January 2009
Electrical › Electrical Distribution System (service) › Switchboard
Issued 2 January 2009
Resolved
Properly secure shore connection opening to switchboard.
Action required: 705 - Other - as specified
Due 2 February 2009
Resolved 9 January 2009
Communications › Radio Communications › EPIRB
Issued 2 January 2009
Resolved
Properly affix NOAA registration sticker onto EPIRB.
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 9 January 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 December 2004
Resolved
Vessel is to immediately stop all operations and proceed directly to Galveston for a RIN
Due 22 December 2004
Resolved 28 December 2004
Communications › Alarms/Indicators › General Alarm
Issued 18 December 2003
Resolved
Prove proper operation of general alarm bell and light in port E/R.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 January 2004
Resolved 30 December 2003
Resolution: Alarm bell and light repaired.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 18 December 2003
Resolved
Reposition crankcase breather on port MDE to vent into the engine air intake and not onto the exhaust/lagging on port MDE.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 December 2003
Resolved 30 December 2003
Resolution: Crankcase breather repositioned to vent into engine air intake.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 December 2003
Resolved
Renew oiled exhaust lagging on port MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 January 2004
Resolved 30 December 2003
Resolution: Exhaust lagging renewed.
Electrical › Electric Generation Source (service)
Issued 18 December 2003
Resolved
Prove proper operation of both port and starboard generator overspeed protection devices. LEGACY COMPONENT DESC: Overcurrent Device
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 January 2004
Resolved 30 December 2003
Resolution: Overspeeds replaced and tested.
Electrical › Electric Generation Source (service) › Panelboard
Issued 18 December 2003
Resolved
Renew /repair ground indicator lights on main switchboard for both generators and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 January 2004
Resolved 30 December 2003
Resolution: Light repaired and tested.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 18 December 2003
Resolved
Secure loose hanging wire for the overspeed device on the starboard generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 January 2004
Resolved 30 December 2003
Resolution: Wire secured.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 December 2003
Resolved
Provide 2 light guards for lights in tool room and replace broken covers in engine rooms.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 January 2004
Resolved 30 December 2003
Resolution: Guards renewed/replaced.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 18 December 2003
Resolved
Replace flame screen on port side fuel vent located near galley entrance.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 January 2004
Resolved 30 December 2003
Resolution: Flame screen replaced.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 December 2003
Resolved
Replace line on starboard fwd ring bouy with black polypropylene line.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 January 2004
Resolved 30 December 2003
Resolution: Line renewed.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 18 December 2003
Resolved
Move deep fat fryer emergency disconnect from behind fryer to an accessable location away from fryer.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 January 2004
Resolved 30 December 2003
Resolution: Emergency disconnect moved 10 feet from fryer.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 18 December 2003
Resolved
Repair fuel leak on port MDE at fuel pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 January 2004
Resolved 30 December 2003
Resolution: Fuel leak repaired.
Engineering › Generator (propulsion-electric)
Issued 18 December 2003
Resolved
Prove proper operation of low lube oil pressure gauge on starboard generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 January 2004
Resolved 30 December 2003
Resolution: Gauge repaired and tested.
Engineering
Issued 27 September 2002
Resolved
Provide approved automation proceedures onboard vessel. Proceedures were previously approved but not located onboard.
Due 27 October 2002
Resolved 27 November 2002
Resolution: Received letter from [name withheld], Kenny Warino / General Manager, attesting to the procedures being onboard.
Electrical › Lighting (emergency)
Issued 27 September 2002
Resolved
Install emergency lighting for port and starboard engineroom emergency escapes and provide additional lighting for port and starboard embarkation areas.
Due 27 October 2002
Resolved 27 November 2002
Resolution: Received invoice for lighting installation.
Construction/Loadline › Hull
Issued 27 September 2002
Resolved
Make repairs to hull/structural damage in way of #1 centerline tank.
Due 27 October 2002
Resolved 30 September 2002
Construction/Loadline
Issued 27 September 2002
Resolved
Make repairs to fracture inway of #1 starboard tank by foward leg tower brace.
Due 30 September 2002
Resolved 30 September 2002
Construction/Loadline
Issued 27 September 2002
Resolved
Make checkvales for preload dump valves operational.
Due 30 September 2002
Resolved 30 September 2002
Construction/Loadline
Issued 27 September 2002
Resolved
Provide NDT and inspection report for leg to pad connections and pad inspection.
Due 27 October 2002
Resolved 10 October 2002
Engineering
Issued 27 September 2002
Resolved
Provide crane servicing report and certification for main crain upon completion of repairs.
Due 10 October 2002
Resolved 10 October 2002
Documentation
Issued 8 May 2001
Resolved
Submit machinery automation procedures in accordance with NVIC 1-78 to cognizant USCG Marine Safety Office for approval.
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Documentation
Issued 18 September 2000
Resolved
PROVE AUTOMATION PROCEDURES ONCE REVIEWED BY COGNIZANT MARINE SAFETY OFFICEAND PROVE SAME TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 18 September 2000
Resolved 18 September 2000
Documentation
Issued 18 September 2000
Resolved
SUBMIT UPDATED FIRE AND SAFETY PLAN TO COGNIZANT COAST GUARD MARINE SAFETY OFFICE FOR VERIFICATION AND APPROVAL. PLAN SHOULD BE IN ACCORDANCE WITH IMO RESOLUTION AND NVIC-8-84.
Condition: Unknown
Due 18 September 2000
Resolved 18 September 2000
Documentation
Issued 18 September 2000
Resolved
SUBMIT MACHINERY AUTOMATION PROCEDURES IN ACCORDANCE WITH NVIC 1-78 TO COGNIZANT MARINE SAFETY OFFICE FOR REVIEW.
Condition: Unknown
Due 18 September 2000
Resolved 18 September 2000
Lifesaving
Issued 18 September 2000
Resolved
PROPERLY INSTALL EMBARKATION LADDER FOR RESCUE BOAT TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 18 October 2000
Resolved 23 October 2000
Lifesaving
Issued 18 September 2000
Resolved
PROVE EMBARKATION LIGHTS ILLUMINATE AREA IN WAY OF LIFERAFTS.
Condition: Unknown
Due 18 October 2000
Resolved 23 October 2000
Documentation
Issued 18 September 2000
Resolved
PROVIDE COMPLETE APPROVED OPERATIONS MANUAL INCLUDING APPENDICES, OR SUBMITUPDATED MANUAL TO COAST GUARD MARINE SAFETY CENTER FOR APPROVAL.
Condition: Unknown
Due 18 September 2000
Resolved 18 September 2000
Engineering
Issued 18 September 2000
Resolved
PROPERLY INSTALL MAIN ENGINE OVERSPEED SHUTDOWNS AND PROVE TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 18 September 2000
Resolved 18 September 2000
Construction/Loadline
Issued 8 July 1999
Resolved
INSTALL INSERT OR VENT CLOSURE DEVICE FOR AIR COMPRESSOR ENGINE IN WAY OF CENTER ENGINE ROOM STARB SIDE.
Condition: Unknown
Due 4 August 1999
Resolved 23 August 1999
Lifesaving
Issued 8 July 1999
Resolved
INSTALL CURRENT 406 EPIRB
Condition: Unknown
Due 4 August 1999
Resolved 23 August 1999
Electrical
Issued 8 July 1999
Resolved
INSTALL 110V OUTLET FOR PORTABLE AIR BLOWER IN WAY OF CENTER ENGINE ROOM FOR AIR COMPRESSOR ENGINE.
Condition: Unknown
Due 4 August 1999
Resolved 23 August 1999
Deck/Cargo
Issued 1 July 1999
Resolved
Provide proof of weight test for small crane. Crane last tested 16JUN97.
Condition: Unknown
Due 1 July 1999
Resolved 1 July 1999
Fire Fighting
Issued 1 July 1999
Resolved
Provide proof of annual inspection on all portable fire extinguishers. Lastinspection was performed on 15JUL98.
Condition: Unknown
Due 1 July 1999
Resolved 1 July 1999
Lifesaving
Issued 1 July 1999
Resolved
Provide proof of annual inspection for both life rafts. Last inspection was 24JUL98.
Condition: Unknown
Due 1 July 1999
Resolved 1 July 1999
Lifesaving
Issued 1 July 1999
Resolved
Remove excessive oil from engine room bilge.
Condition: Unknown
Due 1 July 1999
Resolved 1 July 1999
Construction/Loadline
Issued 1 July 1999
Resolved
Make vessel available for inspection of various metal inserts in the hull and main deck. (see MINS for details)
Condition: Unknown
Due 1 July 1999
Resolved 1 July 1999
Lifesaving
Issued 17 July 1998
Resolved
PROVIDE DOCUMENTATION OF LIFE RAFT SERVICING
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Engineering
Issued 17 July 1998
Resolved
PROVE PROPER OPERATION OF MAIN ENGINE EMERGENCY SHUTDOWN.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Navigation
Issued 17 July 1998
Resolved
PROVE PROPER OPERATION OF RUDDER ANGLE INDICATOR
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Lifesaving
Issued 23 October 1997
Resolved
COVER OR ROPE OFF HOLE IN MAIN DECK
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Construction/Loadline
Issued 23 October 1997
Resolved
Make permanent repairs to hole in main deck in way of port boom. Make temporary repairs prior to moving vessel.
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Deck/Cargo
Issued 23 October 1997
Resolved
Provide certified weight of port crane and pedistal if removed or renewed.
Condition: Unknown
Due 23 October 1997
Resolved 23 October 1997
Documentation
Issued 7 June 1996
Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH CHEMICAL TESTING PROGRAM IAW ALL PARTS OF 46CFR16.
Condition: Unknown
Due 7 July 1996
Resolved 31 July 1996
Documentation
Issued 7 June 1996
Resolved
PROVIDE DETAILED INFORMATION ON CRANES REGARDING LOAD TESTS PERFORMED 15JUN95.
Condition: Unknown
Due 7 July 1996
Resolved 31 July 1996
Documentation
Issued 7 June 1996
Resolved
PROVIDE ON BOARD CURRENT OPERATING MANUAL.
Condition: Unknown
Due 7 July 1996
Resolved 31 July 1996
Documentation
Issued 23 June 1995
Resolved
OPSMAN outdated; must be submitted for approval in accordance with NVIC 8- 91 and 46 CFR 109.
Condition: Unknown
Due 23 July 1995
Resolved 1 September 1995
Documentation
Issued 23 June 1995
Resolved
Vessel must submit previously approved plans & new plans to MSC for review and approval.
Condition: Unknown
Due 23 July 1995
Resolved 1 September 1995
Documentation
Issued 23 June 1995
Resolved
Provide on board - fuel oil transfer piping diagram.
Condition: Unknown
Due 23 July 1995
Resolved 1 September 1995
Accommodation/Occupational Safety
Issued 23 June 1995
Resolved
Washer & Dryer not secured for sea.
Condition: Unknown
Due 23 July 1995
Resolved 30 August 1995