MAURY USCG vessel records
← All vessels

UNITY

UNITY is a 1982 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in February 2026, along with 52 deficiencies and 3 operational controls.

Records from 2016 to 2026. Most recent: inspection, 4 February 2026.

Built
1982
Last inspected
4 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 February 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDA7458
212259
Flag
UNITED STATES
Maury page id
psix-212259

Documentation record

Registered dimensions (L × B × D)63.1 ft × 18.4 ft × 10.5 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnagegross 95 / net 65
BuilderAMF HATTERAS YACHTS · NEW BERN, NC, UNITED STATES · built 1982
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 26 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Convention (Subpart B), Gross Ton
65 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

4 February 2026 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8305828
30 April 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8124192
15 October 2024 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8018890
20 May 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7923026
1 February 2024 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7851529
11 January 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7848338
8 December 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7600420
29 September 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7567724
24 August 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7554557
23 September 2021 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7282848
21 September 2020 Hull Examination · Administrative Inspection · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7062392
28 June 2019 In-Service Inspection · Administrative Inspection · Annual Survey · Deficiency Check · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6728772
30 July 2018 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6506737
28 May 2018 Deficiency Check · Drydock Extension · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6491005
7 March 2018 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6364652
22 September 2017 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6272678
23 August 2016 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5980986
24 May 2016 Deficiency Check · Drydock Exam · Hull Examination · COI Inspection · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5896019

Deficiency record · 52

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 February 2026 Resolved
"Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed..." Port and stbd wet exhaust lines are leaking near fwd bulkhead of engine room. Fix exhaust leak. 46 CFR 182.05-1 (OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2026
Resolved 9 April 2026
Resolution: Received photos of wet exhaust repair and video w/ both main engines running
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 February 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessel has expired items in first aid kit. Vessel must replace all expired items in first aid kit. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 14 February 2024
Resolution: Vessel provided photographic evidence that expired items have been replaced. Deficiency has been resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 February 2024 Resolved
The marine inspector shall examine all accessible parts of the vessels hull, machinery, and equipment to be assured that they are in a satisfactory condition. Vessels bilge hose actively leaks while pumping. Vessel must repair hose. 46 CFR 176.10-5(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 14 February 2024
Resolution: Vessel provided photographic evidence that repairs have been completed. Deficency has been resolved.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 February 2024 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel has life jackets that are not properly marked. Vessel must properly mark life jackets. 46 CFR 185.604 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 14 February 2024
Resolution: Vessel provided photographic evidence that lifejackets have been properly marked. Deficiency has been resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 February 2024 Resolved
All pressure vessels other than unfired steam boilers shall be protected by pressure-relieving devices. FWD pressure vessel in port side of engine room does not have relief valve that can be tested. Vessel must replace relief valve. 46 CFR 54.15-5 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 14 February 2024
Resolution: Vessel provided photographic evidence that a new relief valve has been installed. Deficiency has been resolved.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 January 2024 Resolved
Vessel lapsed time period to schedule 2nd annual inspection. All other vessels must undergo an inspection for certification as specified in § 176.404 and annual inspection as specified in paragraph (b)(1) of this section. (1) Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2024
Resolved 1 February 2024
Resolution: Vessel has completed COI renewal 01FEB2024.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 23 September 2021 Resolved
Controls and valves for operation of fixed gas fire extinguishing system must be: A device must be provided to automatically shut down engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. Vessel pressure switch did not shutdown the port engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 October 2021
Resolution: MI observed functional port side M/E engine shutdown.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 23 September 2021 Resolved
All machinery and equipment must be maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Steering Ram was leaking hydraulic fluid.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 October 2021
Resolution: MI witnessed proper installed fitting on steering ram. No observed hyrdraulic fluid leakage.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 September 2020 Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 176.500(b)(1) and your Certificate of Inspection must be endorsed. Vessel owner failed to make Blue Horizons available for inspection as required by regulation. Vessel must complete a satisfactory annual inspection prior to returning to service.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2021
Resolution: Vessel completed COI in SECNY AOR.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 September 2020 Resolved
The owner or managing operator shall make a vessel available for drydock examinations as required by this section. Vessel owner failed to make Blue Horizons available for drydock by 31 Aug 2020. Vessel must complete a satisfactory drydock inspection prior to returning to service.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 March 2020 Resolved
If the annual inspection reveals deficiencies in your vessel's maintenance, you must make any or all repairs or improvements within the time period specified by the OCMI. Vessel was issued CG835V to repair damaged areas of the flooring by December 2019. This deficiency is past due and remains outstanding.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2021
Resolution: Vessel completed COI in SECNY AOR.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 July 2019 Resolved
Stern lights must be visible at a minimum range of 3 nms. Vessel's stern light is missing bulb. Vessel restricted from carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2019
Resolved 24 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 23 July 2019 Resolved
A fixed fire extinguishing system must be designed and installed in accordance with manufacturer. Vessel unable to prove functionality of fire dampers in engine room. FWD port fire damper is missing springs. Vessel restricted from carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 August 2019
Resolved 1 August 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 23 July 2019 Resolved
At each inspection owner shall have vessel ready for inspection of all interior spaces. On deck, water intrusion has broken and deteriorated flooring. Vessel to remove flooring in aft stbd side to examine extent of damage. Damaged areas to be repaired in December 2019.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2019
Resolved 4 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2019 Resolved
Machinery installed on each vessel shall be maintained to protect against fire, explosion, machinery failure and personnel injury. Vessel missing temperature sensor for high coolant alarm on both generators. Temperature sensor for coolant water on Stbd MDE had fallen off and when it was replaced all alarms were going off on the panel. Provide technician report that all prime movers and propulsion engines have working alarms/sensors.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2019
Resolved 12 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 July 2019 Resolved
The engine head, block and exhaust manifold shall be water jacketed and cooled by water from a pump. On stbd main diesel engine, the jacket water pipe has a leak.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 12 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 July 2019 Resolved
Drip pans fitted with flame screens are required under fuel strainers. Port and stbd generators are missing flame screens.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 1 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2019 Resolved
Electrical installations and equipment shall be reasonable safe from fire caused by or originating in electrical equipment and reasonable safe from electrical shock of personnel. Vessel has various exposed wire terminals in engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 1 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2019 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Battery charger cables located in the engine room aft on the port side have exposed connections.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 1 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 July 2019 Resolved
All unfired pressure vessels shall be examined under operating condition. Port side air tank has a temporary repair made to the bottom of the tank. Vessel restricted from using that unfired pressure vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 12 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2019 Resolved
Cable used must be listed by Underwriters Laboratories as UL Boat or UL Marine cable. Vessel had replaced cables on the batteries with welding cables.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 1 August 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 July 2019 Resolved
The arrangement of the vessel should be such to provide for safe operation with consideration given for a seaworthy hull. Swim platform is missing bolts on the port side.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 10 December 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 July 2019 Resolved
The arrangement of the vessel should be such to provide for safe operation with consideration given for a seaworthy hull. Through hull valve in owners cabin head is missing cover and if opened would let water into the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 1 August 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 June 2019 Resolved
Small Passenger Vessels must undergo an annual inspection within 3 months before or after each anniversary date on the Certificate of Inspection. Vessel has missed its window to conduct an annual inspection. Prior to carry passengers vessel must conduct a satisfactory annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2019
Resolution: Completed Annual Inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 1 August 2018 Resolved
Rescue Platform is deteriorated, replace or provide repair proposal for rescue platform. 46CFR177.101
Action required: 15 - Rectify deficiencies by next port
Due 26 September 2018
Resolved 26 September 2018
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 August 2018 Resolved
Fiberglass on bowthuster tube is wasted, repair of replace bow thurster tube, provide repair proposal prior to conducting glass work. 46CFR177.101
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 August 2018
Resolution: Waster fiberglass repaired/replaced. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 1 August 2018 Resolved
Make all valves with through hull penetrations available for inspection. Unable to verify 10 valves Port Side, 12 Valves Starboard Side,and 2 valves on stern with in 6 inches from water line. Additionally 4 valves under the waterline. 46CFR171.119(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 August 2018
Resolution: All valves inspected and found sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 June 2018 Resolved
Vessel is unable to conduct a drydock inspection and does not qualify for an extension. Prior to carrying PAX, vessel must complete a satisfactory drydock exam in the presence of a USCG Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2018
Resolved 10 August 2018
Resolution: Completed DD exam in Savannah, GA
Lifesaving › Hand Flares › Quantity
Issued 7 March 2018 Resolved
Obtain 3 red & 3 orange flares.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2018
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 March 2018 Resolved
Obtain FCC Safety Certificate
Due 7 April 2018
Resolved 12 March 2018
Engineering › Bilge Water Management System › Pump
Issued 7 March 2018 Resolved
Vessel must obtain portable secondary means to dewater vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2018
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 7 March 2018 Resolved
Vsl required to obtain current DOT Approved alcohol test strips.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2018
Engineering › Fuel Oil Service System › Filter
Issued 7 March 2018 Resolved
Vsl must replace Raycor fuel filters on both MDE's petcock valves with mechanical closing devices.
Due 7 April 2018
Resolved 8 March 2018
Electrical › Electrical Distribution System (service) › Cable
Issued 7 March 2018 Resolved
Replace plastic zip tie electrical cabling overhead support in engine room with proper metal supports.
Due 7 April 2018
Resolved 8 March 2018
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 7 March 2018 Resolved
Develop system for MOB drills where one of the crew members tends to the crew member on the rescue platform during MOB recovery. Proper PFD should be worn by crew member on platform.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2018
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 September 2017 Resolved
Vessel operator failed to make vessel available to OCMI for annual inspection. COI removed from vessel until annual inspection completed. Vessel is not permitted to carry passengers for hire until annual inspection is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2019
Resolution: Old deficiency. Cleared.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 23 August 2016 Resolved
Provide OCMI with cause of MSD leak/water intrusion and submit repair proposal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2016
Resolution: Located thru hull valve & secured.
Engineering › Lubricating Oil Storage/Transfer System › Filter/Strainer
Issued 24 June 2016 Resolved
Repair lube oil leak below oil changing station on aft bulkhead of engine room.
Due 13 July 2016
Resolved 23 August 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 June 2016 Resolved
Repalce electrical outlet cover on port side of engine room with cover equipped with hinged outlet covers.
Due 13 July 2016
Resolved 18 July 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 24 June 2016 Resolved
Replace light cover in lower salon overhead & in stairway
Due 13 July 2016
Resolved 18 July 2016
Communications › Alarms/Indicators › High Water Alarm
Issued 24 June 2016 Resolved
Crewmen are to check all bilge spaces once an hour while underway until high water alarm light indicators are repaired.
Due 13 July 2016
Resolved 30 September 2016
Navigation › Piloting/Steering › US Coast Pilot
Issued 14 June 2016 Resolved
Update navigation publications.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 23 June 2016
Resolution: Nav pubs were updated.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 14 June 2016 Resolved
Provide annual servicing to portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 23 June 2016
Resolution: Portable extinguishers were serviced.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 24 May 2016 Resolved
Show proof of current FCC SSL.
Due 1 July 2016
Resolved 23 June 2016
Resolution: Original FCC SSL was found current and placed on the vessel.
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 24 May 2016 Resolved
Show proof of current Radio operators permit.
Due 1 July 2016
Resolved 23 June 2016
Resolution: Operator's permit was found by the Master.
Documentation › Logs/Records › Logbook (official)
Issued 24 May 2016 Resolved
Show proof of current logboof reflecting drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 23 June 2016
Resolution: Logbook was placed on the vessel and showed current drills.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 24 May 2016 Resolved
Show proof of crewmembers enrollment in a DOT approved drug program.
Due 1 July 2016
Resolved 23 June 2016
Resolution: All members were shown to be current in a DOT approved drug consortium (APCA).
Communications › Alarms/Indicators › High Water Alarm
Issued 24 May 2016 Resolved
Show proof of visual lights for high water alarms.
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 23 June 2016
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 24 May 2016 Resolved
Label lifejacket stowage areas with number of lifejackets.
Due 1 July 2016
Resolved 23 June 2016
Resolution: Stowage areas were labeled properly.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 24 May 2016 Resolved
Show proper operation of ventilation closures.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 24 June 2016
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (electric)
Issued 24 May 2016 Resolved
Install new starter and show proper operation of starboard genset.
Due 1 July 2016
Resolved 24 June 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2016 Resolved
Show proof of current first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 23 June 2016
Resolution: A new first aid kit was purchased and placed in service.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.