Records from 1988 to 2021. Most recent: inspection, 29 July 2021.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 51
29 July 2021
Type not recorded
No type recorded · Station Ponce De Leon Inlet · USCG Southeast District (CGD-SE) · Activity 7272250
13 October 2020
Type not recorded
No type recorded · Station Ponce De Leon Inlet · USCG Southeast District (CGD-SE) · Activity 7076636
28 July 2015
Internal Structural Exam · Drydock Exam · DAPI Audit · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5197572
22 August 2011
Drydock Exam · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4124120
22 August 2011
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4132126
5 March 2010
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3703473
1 March 2010
Type not recorded
No type recorded · Station Ponce De Leon Inlet · USCG Southeast District (CGD-SE) · Activity 3688385
21 January 2009
Simplified Stability Test
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3403918
17 September 2008
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3325267
18 April 2008
DAPI Audit
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3187057
26 September 2007
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3206245
25 September 2007
Deficiency Check · Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3065474
8 February 2007
Simplified Stability Test · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2869207
16 October 2006
Annual Inspection · In-Service Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2801798
22 November 2005
Hull Examination · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2543550
1 September 2005
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2480471
9 August 2005
Administrative Inspection · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2455483
9 August 2004
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2160691
26 August 2003
Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1886296
5 May 2003
Periodic Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1787742
24 June 2002
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1635767
10 September 2001
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1461436
9 August 2001
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1415666
24 July 2001
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1067265
9 August 2000
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1361642
30 August 1999
Hull Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1463507
7 August 1998
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1400827
19 September 1997
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 778504
26 August 1997
Inclining Experiment
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1465329
7 August 1997
COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 783167
1 October 1996
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 833426
19 September 1996
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 960984
16 September 1996
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 957502
28 September 1995
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1192072
9 August 1995
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1192864
9 August 1994
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 862673
20 September 1993
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 837354
10 August 1993
Hull Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 845813
21 April 1993
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 839933
6 August 1992
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 949814
24 September 1991
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 938493
9 August 1991
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 933516
11 March 1991
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1215010
20 February 1991
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 913235
13 February 1991
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 908734
17 January 1991
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 924587
4 January 1991
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1210850
22 March 1990
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1212771
9 August 1989
Re-Inspection · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1346192
10 March 1989
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1202254
9 August 1988
Hull Examination · Initial Certification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1199809
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 August 2015
Resolved
Replace battery for ringbuoy lifelight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2015
Resolved 3 August 2015
Resolution: Corrected on the spot
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 3 August 2015
Resolved
Repari 01 adult and 01 child lifejackets
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2015
Resolved 3 August 2015
Resolution: Corrected on the spot
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 3 August 2015
Resolved
Obtain current editions of required pubs.
Action required: 705 - Other - as specified
Due 3 September 2015
Resolved 5 August 2015
Resolution: Received e-mail from Captain with scanned front pages of coast pilot and U.S. Coast Pilot.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 3 August 2015
Resolved
Obtain current notice to mariners reports to make chart corrections
Action required: 705 - Other - as specified
Due 3 September 2015
Resolved 5 August 2015
Resolution: Received e-mail from Captain with scanned receipt of new chart.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 22 August 2011
Resolved
Provide proof of alcohol testing required for crew within two hours of any potential marine casualty prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2011
Resolution: Received email proof of receipt and pictures.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 17 September 2008
Resolved
Repair or renew the 22 man Life Float.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2008
Resolution: New Life Float
Lifesaving › Lifebuoys › Serviceable
Issued 17 September 2008
Resolved
Renew ring buoy.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2008
Resolution: New ring buoy
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 17 September 2008
Resolved
Renew the line on the water light.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2008
Resolution: Line renewed
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 September 2008
Resolved
Provide a approved first aid kit.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2008
Resolution: New first aid kit
Electrical › Lighting (service) › Lighting Fixture
Issued 17 September 2008
Resolved
Repair the lights in the lower cabin
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 October 2008
Resolved 30 September 2008
Resolution: Repaired, lights working fine
Documentation › Markings/Placards › Lifejacket Placard
Issued 17 September 2008
Resolved
Provide a life jacket placard
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 October 2008
Resolved 30 September 2008
Resolution: Placard is up.
Operations/Management › Drug and Alcohol Testing › MRO Specified
Issued 27 February 2008
Resolved
No drug and alcohol program in place specifying MRO.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 12 June 2008
Resolution: MRO specified in writing.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 27 February 2008
Resolved
Failure to conduct proper Pre-Employment drug testing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 12 June 2008
Resolution: Proof of pre-employment testing provided.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 27 February 2008
Resolved
No EAP policy or hotline phone numbers posted
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 12 June 2008
Resolution: EAP Hotline phone numbers and policy posted.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 27 February 2008
Resolved
No supervisor or employee has been trained about EAP.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 12 June 2008
Resolution: Proper EAP training conducted.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 27 February 2008
Resolved
No documentation supporting submission of submission of MIS reports.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 12 June 2008
Resolution: MIS Submission proof supplied.
Construction/Loadline › Hull › Stringer
Issued 25 September 2007
Resolved
Repair holes and rotten wood on main stringers in steering compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 9 October 2007
Resolution: Stringers were properly repaired. All Sat.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 September 2007
Resolved
Cap pipe fitting (elbow) on forward engine room bulkhead starboard side.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 9 October 2007
Resolution: Removed pipe from bulkhead and properly patched with fiberglass. All Sat.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 September 2007
Resolved
Fill hole near centerline of forward engine room bulkhead (in way of fire extinguisher mounting bracket) with approved sealant.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 9 October 2007
Resolution: Hole covered with metal plate. All Sat.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 September 2007
Resolved
Fill two drain holes in bottom of collision bulkhead.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 9 October 2007
Resolution: Holes plugged with fiberglass. All Sat.
Construction/Loadline › Penetrations › Pipe Flange
Issued 25 September 2007
Resolved
Install double hose clamps on fish box drain lines that penetrate the main deck.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 9 October 2007
Resolution: All deck hose penetrations were double clamped.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 September 2007
Resolved
Tighten or replace as needed all screws on ladder going up to operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 9 October 2007
Resolution: All new bolts and nuts installed on ladder rungs. All Sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 September 2007
Resolved
Install new lens on stern light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 9 October 2007
Resolution: New stern light lens installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 October 2006
Resolved
Provide guard for main diesel engine drive pulleys on front of engine.
Condition: Unknown
Due 13 November 2006
Resolved 27 October 2006
Resolution: Gaurd is on engine.
Lifesaving › Lifefloat › Serviceable
Issued 13 October 2006
Resolved
Repair tears and cracks on life float.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 November 2006
Resolved 27 October 2006
Resolution: Tears cracks were repaired
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 October 2006
Resolved
Port running light inop. Repair as needed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 October 2006
Resolution: Replaced light.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 October 2006
Resolved
STBD running light lens cracked. Renew
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 October 2006
Resolution: Replaced lens.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 October 2006
Resolved
AFT hand rail gate section missing. Provide rail.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2006
Resolution: Hand rail was replaced.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 13 October 2006
Resolved
Holes in forward engine room bulkhead between engine room and FWD cabin where sewage valve is located. Seal holes.
Condition: Improper/Lack of Maintenance
Due 13 October 2006
Resolved 27 October 2006
Resolution: All holes are sealed
Lifesaving › Lifefloat › Paddle
Issued 13 October 2006
Resolved
Renew paddles. Paddles are missing.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2006
Resolution: New paddles.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 October 2006
Resolved
Label remote fixed engine room fire extinguishing system pull handle.
Condition: Improper/Lack of Maintenance
Due 13 November 2006
Resolved 27 October 2006
Resolution: Pull handle is labeled
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 October 2006
Resolved
Repair wire on light in the over head in the lower cabin.
Condition: Improper/Lack of Maintenance
Due 13 November 2006
Resolved 27 October 2006
Resolution: Wire was replaced
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 13 October 2006
Resolved
Install quick disconnect clip on life ring float light.
Condition: Improper/Lack of Maintenance
Due 13 November 2006
Resolved 27 October 2006
Resolution: New clip on line of light.
Engineering › Bilge Water Management System › Pump
Issued 13 October 2006
Resolved
Repair AFT bilge pump in engine room.
Condition: Improper/Lack of Maintenance
Due 13 November 2006
Resolved 27 October 2006
Resolution: Bilge pump is working
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 13 October 2006
Resolved
Provide proof of crew training in CPR/Fist Aid.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 November 2006
Resolved 16 November 2006
Resolution: Received documentary proof of the American Red Cross Training
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 13 October 2006
Resolved
Renew Retroreflective tape on life jackets as needed.
Condition: Improper/Lack of Maintenance
Due 13 November 2006
Resolved 27 October 2006
Resolution: Tape was renewed
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 22 November 2005
Resolved
Type III MSD system three-way directional control valve is inoperable.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 December 2005
Resolved 20 December 2005
Resolution: MSD system three-way directional control valve was repaired and satisfactory operation demonstrated.
Electrical › Electric Supply System (service) › Cable
Issued 22 November 2005
Resolved
Remove wire nuts from the main engine mag. pick-up.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 November 2005
Resolved 20 December 2005
Resolution: Wire nuts were removed.
Electrical › Electric Supply System (service) › Cable
Issued 22 November 2005
Resolved
Repair damage bilge pump electrical cable in the aft compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2005
Resolved 20 December 2005
Resolution: Bilge pump electrical cable properly repaired.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 22 November 2005
Resolved
Renew damage main engine turbo charger exhaust lagging.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2005
Resolved 20 December 2005
Resolution: Lagging renewed.
Construction/Loadline › Hull › Hull Plating
Issued 22 November 2005
Resolved
Repair small hole in fiberglass on starboard side approximately 11/2' inboard of the aft depth sounder, transducer.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 December 2005
Resolved 23 November 2005
Resolution: Received confirmation that the hole was properly repaired.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 August 2005
Resolved
Properly secure deck railing on stbd bow.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2005
Resolved 3 September 2005
Resolution: Corrected.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 August 2005
Resolved
Repair or replace 12V d.c. cabin lights.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 September 2005
Resolved 1 September 2005
Resolution: Lights were replaced and tested satisfactory.
Engineering › Fuel Oil Service System › Valve
Issued 9 August 2005
Resolved
Repair or replace stbd F/O tank return valve. (Valve is not operational).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2005
Resolved 1 September 2005
Resolution: Valve replaced and tested..
Fire Fighting › Structural - B Class Divisions › Machinery Spaces
Issued 9 August 2005
Resolved
Properly seal engine room bulkhead penetrations.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 September 2005
Resolved 1 September 2005
Resolution: Bulkheads were properly sealed.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 9 August 2005
Resolved
Repair or replace engine RPM gauge on the open bridge.
Action required: 705 - Other - as specified
Due 9 September 2005
Resolved 1 September 2005
Resolution: Rpm gauge replaced.
Navigation › Collision/Grounding Avoidance › Radar
Issued 9 August 2005
Resolved
Reinstall and conduct operational test of open bridge radar once repairs are made
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 September 2005
Resolved 1 September 2005
Resolution: Radar was re- installed and tested..
Communications › Radio Communications › EPIRB
Issued 9 August 2005
Resolved
Vessels emergency position indicating radiobeacons hydrostatic release unti is expired. Vessel is prohibited from operating until a receipt of a new EPIRB is received.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 10 August 2005
Resolution: Received documentary proof of newly installed EPIRB hyrostatic release.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 August 2004
Resolved
In accordance with 46 CFR 176.810(b)(2), have an authorized servicing facility conduct the annual service required for the fixed fire extinguishing system for the engine compartment.
Condition: Improper/Lack of Maintenance
Due 17 August 2004
Resolved 13 August 2004
Resolution: Serviced by Daytona Fire and Safety.
Lifesaving
Issued 9 August 2001
Resolved
REPLACE/RENEW BUOYANT APPARATUS (SUNBEATEN).
Condition: Unknown
Due 9 August 2001
Resolved 9 August 2001
Construction/Loadline
Issued 9 August 2001
Resolved
DOUBLE CRAMP ALL UNDERWATER THRU HULL FITTINGS WITH APPROVED CLAMPS.
Condition: Unknown
Due 9 August 2001
Resolved 9 August 2001
Construction/Loadline
Issued 9 August 2001
Resolved
PROVE PROPER OPERATION OF AFT BILGE ALARM.
Condition: Unknown
Due 9 August 2001
Resolved 9 August 2001
Fire Fighting
Issued 9 August 2001
Resolved
PROVE PROPER OPERATION OF THE FIXED FIRE EXT UNIT ( ENGINE SHUT DOWN ) WHENSYSTEM IS ACTIVATED.
Condition: Unknown
Due 9 August 2001
Resolved 9 August 2001
Electrical
Issued 9 August 2001
Resolved
REPLACE/RENEW BONDING STRAP PORT SIDE FUEL TANK.
Condition: Unknown
Due 9 August 2001
Resolved 9 August 2001
Fire Fighting
Issued 9 August 2000
Resolved
PROVIDE 1 B-1 VALID PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 9 September 2000
Resolved 10 August 2000
Lifesaving
Issued 7 August 1997
Resolved
Replace distress signal storage container with an approved container in accordance with 46CFR part 185.
Condition: Unknown
Due 7 August 1997
Resolved 7 August 1997
Lifesaving
Issued 7 August 1997
Resolved
Replace white ring buoy with a 24" international orange ring buoy with retroflective tape and name of vessel. Meanwhile place retroflective tape on white ring buoy until replacement is available.
Condition: Unknown
Due 7 August 1997
Resolved 7 August 1997
Engineering
Issued 16 September 1996
Resolved
INSTALL FUEL TANK CUT-OUT VALVES FOR BOTH FUEL TANKS, LABEL LOCATION OF SAME.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Lifesaving
Issued 16 September 1996
Resolved
RENEW LIFEFLOAT PAINTER WITH BUOYANT LINE OF AT LEAST 1500 LBS BREAKING STRENGTH. THIS REQUIREMENT IS TO BE MET PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Documentation
Issued 16 September 1996
Resolved
PROVIDE COPY OF FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Navigation
Issued 16 September 1996
Resolved
PROVIDE CHARTS OF OP AREA AND THE FOLLOWING PUBS: COAST PILOT, LIGHT LIST, LNM, TIDE TABLES, CURRENT TABLES, RULES OF THE ROAD.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Lifesaving
Issued 16 September 1996
Resolved
PROVIDE THREE (3) RED DISTRESS FLARES. VESSEL IS RESTRICTED TO DAYLIGHT OPERATION UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Lifesaving
Issued 28 September 1995
Resolved
PROVIDE ONE 24" DIAMETER RING BUOY WITH LINE/LIGHT ATTACHMENTS.
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Fire Fighting
Issued 28 September 1995
Resolved
RENEW ONE (1) B-II PORTABLE FIRE EXTINGUISHER ON P/SIDE MAIN DECK.
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Lifesaving
Issued 28 September 1995
Resolved
PROVIDE TWO PADDLES AT LEAST FOUR FEET IN LENGTH FOR LIFEFLOAT.
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Lifesaving
Issued 9 August 1994
Resolved
PROVIDE SIXTEEN REPLACEMENT U.S. COAST GUARD APPROVED WATERLIGHTS FOR VESSEL LIFE PRESERVERS.
Condition: Unknown
Due 24 August 1994
Resolved 24 August 1994
Navigation
Issued 9 August 1994
Resolved
PROVIDE LENS FOR STERN LIGHT.
Condition: Unknown
Due 24 August 1994
Resolved 24 August 1994
Documentation
Issued 10 August 1993
Resolved
PROVIDE DRUG TESTING DOCUMENTATION AS PER CHEM TESTING PROGRAM 46 CFR 16.
Condition: Unknown
Due 10 August 1993
Resolved 10 August 1993
Electrical
Issued 6 August 1992
Resolved
REMOVE OR PROPERLY END IN JUNCTION BOX ALL DEAD END WIRES ON BRIDGE AND IN ENGINE ROOM.
Condition: Unknown
Due 6 August 1992
Resolved 6 August 1992
Construction/Loadline
Issued 6 August 1992
Resolved
PROVIDE METHOD TO SECURE WATER TIGHT HATCH FOR LAZARETT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 August 1992
Resolved 6 August 1992
Lifesaving
Issued 9 August 1991
Resolved
PROVIDE AN APPROVED LIFE RING BUOY AND 60' OF LINE.
Condition: Unknown
Due 9 August 1991
Resolved 9 August 1991
Accommodation/Occupational Safety
Issued 9 August 1991
Resolved
PROVE PROPER OPERATION OF THE MARINE TOILET THREE WAY PLASTIC VALVE.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Navigation
Issued 9 August 1991
Resolved
PROVE PROPER OPERATION OF THE STERN LIGHT, (NAVIGATION LIGHT).
Condition: Unknown
Due 9 August 1991
Resolved 9 August 1991
Documentation
Issued 4 January 1991
Resolved
PROVIDE A COPY OF "CODE OF FEDERAL REGULATIONS PARTS 166 TO 199. _x001C_
Condition: Unknown
Due 4 January 1991
Resolved 4 January 1991
Accommodation/Occupational Safety
Issued 9 August 1989
Resolved
PROVIDE WASTE WATER DRIAN PIPING OR REMOVE WASH BASIN AND PLUG THROUGH HULLSEA VALVE.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Lifesaving
Issued 9 August 1989
Resolved
RENEW AND REMARK VESSELS RING BUOY.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Engineering
Issued 9 August 1989
Resolved
PROVIDE A USCG APPROVED FUEL OIL FILTER, FOR THE MAIN DIESEL ENGINE FUEL OIL SYSTEM.
Condition: Unknown
Due 9 August 1989
Resolved 9 August 1989
Navigation
Issued 9 August 1988
Resolved
PROVIDE NAVIGATION CHARTS AND PUBLICATIONS FOR THE VESSEL'S (ROUTE) OPERATING AREA.
Condition: Unknown
Due 9 August 1988
Resolved 9 August 1988
Documentation
Issued 9 August 1988
Resolved
PROVIDE A VALID FCC COMMUNICATIONS ACT SAFETY CERTIFICATE, FCC RADIO STATION LIC, FCC MARINE OPERATORS PERMIT, AND A COPY OF THE FCC RULES PART 80.
Condition: Unknown
Due 9 August 1988
Resolved 9 August 1988