← All vessels
MISS PASS A GRILLE
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named MISS PASS A GRILLE
MISS PASS A GRILLE is a 1983 passenger vessel (inspected). The Coast Guard has recorded 86 inspections since 1983, most recently in January 2026, along with 220 deficiencies and 2 operational controls.
Records from 1983 to 2026. Most recent: inspection, 5 January 2026.
- Built
- 1983
- Last inspected
- 5 January 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 220 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
654331
WDQ4710
212982
Flag
UNITED STATES
367451650, 368428120
Maury page id
psix-212982
Inspections, by type
…with no type recorded11
Years with a record
37 calendar years (1983–2026)
The 86 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)45.3 ft × 14.8 ft × 7.8 ft
Registered tonnagegross 39 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderVESSEL MARINE MAGT CORP · MEDLEY AND CORTEZ, FL, UNITED STATES · built 1983
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST PETE BEACH, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 2 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it39 - Regulatory (Subpart C or D), Gross Ton
26 - Regulatory (Subpart C or D), Net Ton
26 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDQ4710MMSI 368428120 · active · compulsorily equipped · granted 2 July 2025, expires 2 July 2035 · licensed under a name not among this hull’s recorded names (not shown)
WDF4416MMSI 367451650 · active · compulsorily equipped · granted 24 April 2020, expires 11 May 2030
WRP6311MMSI not assigned · expired · compulsorily equipped · granted 5 November 1997, cancelled 29 December 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 86
5 January 2026
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8289986
3 October 2025
Internal Structural Exam · Hull Examination · Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8244034
27 June 2025
Deficiency Check · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8168859
18 March 2025
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8095705
3 April 2024
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7850351
3 November 2023
Internal Structural Exam · Deficiency Check · Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7819711
23 January 2023
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7577176
29 November 2021
Annual Inspection · Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7358694
1 November 2021
Internal Structural Exam · Administrative Inspection · Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7337886
4 June 2021
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7218222
5 January 2021
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7131227
4 January 2021
COI Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7119144
25 September 2020
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7065275
25 September 2020
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7069492
9 January 2020
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6877324
3 October 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6818557
17 July 2019
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6752981
23 April 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6669305
25 February 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6645194
9 January 2019
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6594674
19 December 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6600874
22 May 2018
Damage Survey · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6421184
22 May 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6422162
25 January 2018
Simplified Stability Test
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6345578
27 November 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6324951
13 November 2017
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6269423
10 October 2017
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6269412
6 January 2017
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6059952
28 September 2015
Examination of Repairs · Internal Structural Exam · Drydock Exam · COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5730285
26 January 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4232403
12 September 2011
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4140437
10 September 2010
MTSA Verification · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3847117
7 December 2009
Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3642711
28 December 2008
Type not recorded
No type recorded · USCGC CROCODILE (WPB 87369) · USCG East District (CGD-E) · Activity 3388761
16 September 2008
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3325842
5 September 2007
Hull Examination · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3049407
25 September 2006
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2783908
8 September 2005
COI Inspection · Hull Examination · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2486588
7 February 2005
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2287709
15 March 2004
Annual Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2022177
19 January 2004
Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1988194
3 October 2002
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1684368
15 July 2002
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1647268
21 May 2002
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1618650
16 April 2002
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1605789
4 March 2002
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1489440
9 February 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1436509
12 January 2001
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1397548
17 August 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1052741
12 June 2000
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1415377
31 March 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1047039
14 March 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1441627
26 March 1999
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1118967
5 March 1999
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1440185
12 June 1998
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1459407
7 January 1998
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1390688
27 January 1997
Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1406166
13 May 1996
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1402261
29 January 1996
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1080568
6 January 1995
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1167793
9 May 1994
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 862768
10 January 1994
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1161478
25 January 1993
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1144416
9 July 1992
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1261473
11 May 1992
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1271037
7 January 1992
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 949768
10 September 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1243552
8 July 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 937841
22 April 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1231007
4 February 1991
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 996300
2 October 1990
Permit to Proceed
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 929585
12 July 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899456
14 May 1990
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1211031
22 March 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1213476
5 February 1990
Re-Inspection · Drydock Extension
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1220498
23 August 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1210351
20 March 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 894580
10 March 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 893875
10 February 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1034310
6 January 1989
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1343830
20 September 1988
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1042989
11 January 1988
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1016263
30 June 1987
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1012369
12 January 1987
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1003915
6 January 1986
COI Inspection · Credit Drydock
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1301972
21 January 1983
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 979512
Deficiency record · 220
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 January 2026
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Provide label for child life jackets.
46 CFR 180.78(a)(5)
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 14 January 2026
Resolved
Each vessel must meet the applicable requirements in Subchapter S of this chapter. Each hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices to prevent its loss. Provide device to prevent loss of lazaratte hatch cover.
46 CFR 177.13-1 OLD T
46 CFR 174.220(b)(2)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 January 2026
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. You must submit your written application for renewal of a Certificate of Inspection to the OCMI at least 30 days prior to the expiration date of the Certificate of Inspection, as required in § 176.105 of this part. Vessel's COI expires on 05JAN2026. Vessel is restricted from operating with passengers on 06JAN2026.
46 CFR 176.404(b)
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 July 2025
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: fixed gas fire extinguishing system to check for excessive corrosion and general condition. MI observed pre-engineered fixed gas fire extinguisher for machinery space out of inspection. Inspection was due in June 2025.
46 CFR 176.810 (a) (1)
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 July 2025
Resolved
Each flare carried to meet this section must be stowed in one of the following:
A portable watertight container marked as required by § 185.614 of this chapter, carried at the operating station. MI observed vessel did not have suitable container to hold all 12 distress flares. Replace container within 5 days.
46 CFR 180.68
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 8 July 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. MI observed emergency instructions not posted onboard vessel. Post instructions within 5 days.
46 CFR 185.512
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 July 2025
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements:
(1) Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license.
(2) Where the station power exceeds 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a general radiotelephone operator license or higher class license. MI observed master without proof of current marine radio operator permit. Vessel restricted to operation within 1,000 feet from shore.
47 CFR 80.159 (e)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 July 2025
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. MI observed lanyard too short and not wrapped around body of ring life buoy. Repair within 5 days.
46 CFR 180.70 (d) (2)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 July 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI observed loose housing for port navigation light and unsuitable wire routing of starboard navigation light. Vessel restricted to daylight, fair weather operations only with a minimum of 1 nautical mile of visibility.
46 CFR 183.420
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 July 2025
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. MI observed light holding bracket on port side aft life float mounted upside down so light is always on even when not in use. Repair within 5 days.
46 CFR 180.175 (d)
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 3 April 2025
Resolved
Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF-DSC frequency transmitter meeting the requirements of § 80.1101(c)(3) and capable of transmitting J3E emission and a receiver capable of reception of J3E emission within the band 1710 to 2850 kHz. MI observed vessel was not able to complete an operational test of MF radio.
47 CFR 80.905(a)(2)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 April 2025
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in a space with a through-hull fitting below the deepest load waterline, a machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space, and a space with a non-watertight closure. MI observed no visual indication of bilge high water level alarm in MSD space.
46 CFR 182.530(a)
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 April 2025
Resolved
The required EPIRB test shall be logged. MI observed EPIRB tests were not being conducted monthly.
46 CFR 185.728(c)
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 April 2025
Resolved
The required fire and man overboard drills shall be logged. MI observed that fire and MOB drills were not being performed.
46 CFR 185.520(f)
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 3 April 2025
Resolved
Each officer employed on any vessel subject to this subchapter must have his or her license or merchant mariner credential onboard and available for examination at all times when the vessel is operating. MI observed master without radar observer endorsement on MMC despite having radar onboard.
46 CFR 185.402
46 CFR 11.480 (b)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 April 2025
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI observed unserviceable retroreflective tape on 02 port side life floats. MI observed all life floats missing vessel name stenciling.
46 CFR 176.808 (b)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 April 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. MI observed operator unable to test nor provide proof that pre-engineered fixed gas fire extinguishing system in engine room was operational.
46 CFR 181.420(a)(3)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 April 2025
Resolved
A vessel's hull must not carry current as a conductor. MI observed steering gear in lazarette to have damaged and inoperational ground wire.
46CFR183.370(a)
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 3 April 2025
Resolved
For each marine casualty required to be reported by § 185.202, the owner, agent, master, or person in charge of the vessel shall determine whether there is any evidence of alcohol or drug use by individuals directly involved in the casualty. MI observed expired alcohol test strips onboard the vessel and none available on the pier.
46 CFR 185.210 (a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 April 2025
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. MI observed RPM gauge for port side engine installation inoperable.
46 CFR 182.410(B)
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 April 2025
Resolved
As appropriate for the intended voyage, all vessels must carry adequate and up-to-date charts, Coast Pilot [name withheld], Tide Tables. MI observed no backup charts for electronic charts on vessel.
46 CFR 185.20-35
NVIC 01-16
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 3 April 2025
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include documentation of training given to crewmembers and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. MI observed master has not completed 60 minutes of training.
46 CFR 16.401 (b)
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 3 April 2025
Resolved
A vessel must be fitted with a Federal Communications Commission (FCC) type accepted general marine radar system for surface navigation with a radar screen mounted at the primary operating station if the vessel has an oceans route. MI observed non-operational radar on bridge.
46 CFR 184.404
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 3 April 2025
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements:
(1) Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. MI observed master did not have a current marine radio operator permit.
47 CFR 80.159(e)(1)
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 April 2024
Resolved
46 CFR 182.455(b)(4)
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located.
MI observed that the valves were not completely closing when operated by remote shutoff.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 3 April 2024
Resolved
47 CFR 80.905(a)(2)
Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF-DSC frequency transmitter meeting the requirements of § 80.1101(c)(3) and capable of transmitting J3E emission and a receiver capable of reception of J3E emission within the band 1710 to 2850 kHz.
Vessel was not able to test radio.
CODE 705: Vessel is restricted to operating operated solely within 20 nautical miles of land until proper operation of radio can be provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 April 2024
Resolved
46 CFR 180.71(a)
An adult life jacket must be provided for each person carried on board a vessel.
MI observed 06 life jackets that were not serviceable.
CODE 705: Vessel is restricted to carrying 39 people that would require an adult size life jacket.
O/O provided proof of 05 new adult sized life jackets.
UPDATED CODE 705: Vessel is restricted to carrying 44 people that would require an adult size life jacket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 April 2024
Resolved
46 CFR 180.71(b)
A number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided.
MI observed 01 child size life jackets that were not serviceable.
CODE 705: Vessel is restricted to carrying 04 passengers that would require a child size life jacket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 April 2024
Resolved
46 CFR 180.70(d)(1)
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110.
MI observed that the floating water light did not have batteries required by the light manufacturer.
705: Vessel is restricted to daytime operations.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 April 2024
Resolved
46 CFR 180.70
The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant.
MI observed that 04 life float lights did not have batteries required by the light manufacturer.
CODE 705: Vessel is restricted to daytime operations.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 3 April 2024
Resolved
46 CFR 185.510(a)
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions.
MI observed that vessel did not have emergency instructions posted or on board.
CODE 705: Rectify deficiency in 05 days.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 November 2023
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural exam at least once every two years. Vessel was due for drydock examination on 31OCT23 and has yet to receive a drydock exam.
46 CFR 176.600(c)(1)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 January 2023
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station.
The RPM gauges for the new engine installation were found inoperable.
Replace in kind.
46 CFR 182.410(B)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 January 2023
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must: Be buoyant; Be of at least 18.3 meters (60 feet) in length; Have a diameter of at least 7.9 millimeters ( 5/16 inch).
The lifeline found onboard was less than 40 feet in length.
46 CFR 180.70
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 January 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. The operator installed the engine starting conductor in the bilge and the conductor is not supported.
The installation creates an electrical shock hazard to personnel.
Remove the conductor from the bilge and support IAW the regulations.
46 CFR 183.05-50(a)
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 January 2023
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent.
The engine room hatch does not have adequate material to close the hatch to the engine room and seal off the space for use of the fire suppression system.
46 CFR 182.465
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 14 February 2022
Resolved
Vessel shall be sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water. In addition, the arrangement shall prevent the risk of the crew falling overboard during recovery operations.
MI observed the crew member struggling to keep the rescue platform secured into the brackets located on the port quarter of the vessel. The rescue platform base is made of plastic with holes drilled into it. The current design of the platform is substantially effected by wave action. Drill was conducted in 1 to 1.5 foot seas. The rescue platform forward mounting bracket became unattached during the drill.
46 CFR 180.210(a)(1)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2021
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years.
Vessel lapsed on DD/ISE dates.
46 CFR 176.600(c)(1)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 September 2020
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Mast head light, stbd running light, and stern light found to be unmounted. Vessel operation restricted to daytime and clear visibility only. 46 CFR 183.420
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 20 June 2018
Resolved
The Master shall conduct drills and give instructions as necessary to ensure that all crew members are familiar with their duties. Master and crew were not familiar with emergency procedures or vessel rescue equipment. Complete crew training prior to operation with passengers. 46 CFR 185.25-10
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 June 2018
Resolved
As appropriate for the intended voyage, all vessels must carry adequate and up-to-date charts, Coast Pilot [name withheld], Tide Tables. Publications on vessel were outdated; update publications as required. 46 CFR 185.20-35
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 June 2018
Resolved
Instructions for the operation of the fixed fire extinguishing system must be posted at the control station. Post instructions for activation at pull station in pilot house. 46 CFR 181.20-15
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 June 2018
Resolved
Replacement shall be made of expired distress signals; all distress signals are expired. Replace as required. 46 CFR 180.35(b)
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 20 June 2018
Resolved
Before getting underway, master shall ensure safety announcements are made. Master of vessel was unaware of safety orientation requirements as listed in regulation. 46 CFR 185.25-1(d)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 June 2018
Resolved
Each ring buoy shall be of an approved type; replace worn retro-reflective material on life ring buoy. 46 CFR 180.30-1
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 June 2018
Resolved
A life jacket shall be provided for each person on board; replace one non-serviceable adult life jacket and provide light. Provide light for one child life jacket. 46 CFR 180.25-5
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 20 June 2018
Resolved
Life float water light. Secure bracket for life float water light in float free arrangement. 46 CFR 180.15-5
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 June 2018
Resolved
Replace expired alcohol testing devices. 46 CFR 16
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 June 2018
Resolved
Provide list of current employees enrolled in chemical testing program. 46 CFR 16
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 20 June 2018
Resolved
The color of the life float must be primarily vivid reddish orange. All life floats are faded and do not meet color standard. Apply life float manufacturers recommended product to meet color requirement. 46 CFR 180.05-1
Fire Fighting › Remote Fuel Shutoff › General
Issued 22 May 2018
Resolved
SHUTOFF VALVES, INSTALLED SO AS TO CLOSE AGAINST THE FUEL FLOW, SHALL BE FITTED IN THE FUEL SUPPLY LINES, ONE AT THE TANK CONNECTION AND ONE AT THE ENGINE END OF THE FUEL LINE TO STOP FUEL FLOW WHEN SERVICING ACCESSORIES. THE SHUTOFF VALVE AT THE TANK SHALL BE OPERABLE FROM OUTSIDE THE TANK COMPARTMENT, PREFERABLY FROM AN ACCESSIBLE POSITION ON THE WEATHER DECK. MARINE INSPECTOR IDENTIFIED BOTH EMERGENCY FUEL SHUTOFFS FOR PORT AND STARBOARD FUEL TANKS HAD BEEN DISASSEMBLED RENDERING SYSTEM INOPERABLE. INSTALL BOTH EMERGENCY FUEL SHUTOFF ON PORT AND STARBOARD TANKS IN ACCORDANCE WITH ABOVE CITE. 46 CFR 182.20-40(b)(3)
Engineering › Fuel Oil Service System › Filter
Issued 22 May 2018
Resolved
A SUITABLE MARINE TYPE STRAINER SHALL BE FITTED IN THE FUEL SUPPLY LINE IN THE ENGINE COMPARTMENT. NO SPECIAL FUEL STRAINER OTHER THAN THOSE RECOMMENDED OR FURNISHED BY THE ENGINE MANUFACTUREE WILL BE REQUIRED. DRIP PANS FITTED WITH FLAME SCREENS MAY BE REQUIRED UNDER FUEL STRAINERS OTHER THAN THOSE MOUNTED ON THE ENGINE. MARINE INSPECTOR IDENTIFIED THE STARBOARD RACOR FUEL FILTER MISSING FLAME IMPINGEMENT BOWL. INSTALL FLAME IMPINGEMENT BOWL. 46 CFR 182.20-40(b)(5)
Stability › Watertight Integrity › General
Issued 22 May 2018
Resolved
IT SHALL BE THE DUTY OF THE MASTER OF ANY VESSEL TO ASSURE THAT ALL EXPOSED HATCHES ARE PROPERLY SECURED BEFORE GETTING UNDERWAY FOR A VOYAGE ON OTHER THAN PROTECTED WATERS. MARINE INSPECTOR INDENTIFIED AFT STEERING HATCH LOCKING DEVICE WAS INOPERABLE NOT ALLOWING THE HATCH TO BE SECURED. REPAIR OR REPLACE HATCH AND PROVE PROPER OPERATION. 46 CFR 185.20-15
Engineering › Fuel Oil Service System › Hose
Issued 22 May 2018
Resolved
A LOOP OF TUBING OR SHORT LENGTH OF FLEXIBLE HOSE SHALL BE INSTALLED IN THE FUEL SUPPLY LINE AT OR NEAR THE ENGINES. SUCH FLEXIBLE HOSE SHALL BE PROVIDED WITH SUITABLE CONNECTION FITTINGS AND SHALL HAVE A HIGH RESISTANCE TO SALT WATER, PETROLEUM OILS, HEAT AND VIBRATION. MARINE INSPECTOR IDENTIFIED FUEL SUPPLY LINE TO STARBOARD MAIN DIESEL ENGINE LOCATED INBOARD SIDE FORWARD AT ENGINE MOUNT HAD CHAFED THROUGH OUTER COVERING DUE TO VIBRATION. REPLACE FUEL LINE INDENTIFIED ABOVE AND PROVIDE PROPER SUPPORT BRACKETS. 46 CFR 182.20-40(b)(4)
Fire Fighting › Combustible Materials › Stowage
Issued 22 May 2018
Resolved
NO FLAMMABLE OR COMBUSTIBLE LIQUIDS MAY BE STOWED IN ANY ACCOMMODATION, CONTROL, OR SERVICE SPACE (OTHER THAN A PAINT LOCKER). MARINE INSPECTOR IDENTIFIED A FIVE GALLON TANK FULL OF GASOLINE STORED IN THE BILGE LOCATED BEHIND THE STARBOARD MAIN DIESEL ENGINE. REMOVE FIVE GALLON GASOLINE CAN FROM THE ENGINE ROOM. 46 CFR 175.45(b)
Electrical › Electric Supply System (service) › Battery Installation
Issued 22 May 2018
Resolved
BATTERIES SHALL BE SO LOCATED THAT THE GAS GENERATED IN CHARGING WILL BE EASILY DISSIPATED BY NATURAL OR INDUCED VENTILATION. BATTERIES SHOULD NOT BE LOCATED IN THE SAME COMPARTMENT WITH GASOLINE TANK OR ENGINE, BUT WHERE LOCATION ELSEWHERE IS IMPRACTICABLE, THEY SHALL BE EFFECTIVELY SCREENED BY A CAGE OR SIMILAR STRUCTURE TO MINIMIZE THE DANGER OF ACCIDENTAL SPARK THROUGH DROPPING A METAL OBJECT ACROSS TERMINALS. MARINE INSPECTOR INDENTIFIED BATTERY BANK LOCATED IN THE ENGINE ROOM AFT BULKHEAD WITH PROTECTIVE COVER MISSING EXPOSING ALL BATTERY TERMINALS. REPLACE BATTERY COVER. 46 CFR 183.02-20(a)
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 May 2018
Resolved
SUITABLE COVERS, GUARDS, OR RAILS SHALL BE INSTALLED IN WAY OF ALL EXPOSED AND HAZARDOUS PLACES SUCH AS GEARS, MACHINERY, ETC. MARINE INSPECTOR INDENTIFIED BOTH PORT AND STARBOARD ENGINES WERE MISSING GUARDS COVERING EXPOSED ACCESSORY DRIVES ON FRONT OF BOTH ENGINES.INSTALL PROTECTIVE GUARDS ON EXPOSED ACCESSORY DRIVES ON BOTH PORT AND STABOARD ENGINES. 46 CFR 177.35-15(a)
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 May 2018
Resolved
THE CERTIFICATE OF INSPECTION (COI) SHALL, IN GENERAL, BE FRAMED UNDER GLASS OR OTHER TRANSPARENT MATERIAL AND POSTED IN A CONSPICUOUS PLACE. WHEN THE FRAMING OF THE CERTIFICATE WOULD BE IMPRACTICABLE, THE COI SHALL BE KEPT ON BOARD TO BE SHOWN ON DEMAND. MARINE INSPECTOR IDENTIFIED THE COI WAS NOT POSTED ANY PLACE ON THE VESSEL FOR VERIFICATION. PROVIDE ORIGINAL COI TO MARINE INSPECTOR AND POST IN CONSPICUOUS PLACE ON THE VESSEL. 46 CFR 176.01-40
Documentation › Certificates/Documents › Stability Letter
Issued 22 May 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Vessel Activity › Other
Issued 22 May 2018
Resolved
THE COGNIZANT OCMI MAY REQUIRE THAT A VESSEL AND ITS EQUIPMENT UNDERGO ANY ADDITIONAL TEST OR INSPECTION DEEMED REASONABLE AND NECESSARY TO DETERMINE THAT THE VESSEL AND ITS EQUIPMENT ARE SUITABLE FOR THE SERVICE IN WHICH THEY ARE TO BE EMPLOYED. BASED ON OBJECTIVE EVIDENCE, FOUND VESSEL IS NOT FIT FOR INTENDED ROUTE AND SERVICE. COMPLETE COAST GUARD INSPECITON PRIOR TO OPERATION. 46 CFR 176.840
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 27 November 2017
Resolved
Pre-engineered fixed gas extinguishing system missing operating instructions at ops station,
post pre-engineered fixed gas extinguishing system missing operating instructions at ops station, to the satisfaction of the attending marine inspector. 46CFR181.420
Lifesaving › Launching Appliances › Release Mechanism
Issued 27 November 2017
Resolved
Hydrostatic release date expired, replace with new hydrostatic release to the satisfaction of the attending marine inspector. 46CFR185.740
Communications › Radio Communications › EPIRB
Issued 27 November 2017
Resolved
EPIRB battery date expired, replace battery to the satisfaction of the attending Marine Inspector. 46CFR180.64
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 November 2017
Resolved
Waterlight disabled, replace waterlight to the satisfaction of the attending Marine Inspector. 46CFR180.70
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 November 2017
Resolved
Lifeline not appropriate length, replace lifeline with appropriate type and length to the satisfaction of the attending Marine Inspector. 46CFR180.70
Communications › Radio Communications › VHF Radiotelephone
Issued 27 November 2017
Resolved
MMSI number not entered in VHF radio, enter MMSI number in VHF radio to the satisfaction of attending Marine Inspector. 47CFR80
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 27 November 2017
Resolved
Expired Tide tables and Current tables, replace with update tide tables and current tables to the satisfaction of the attending Marine Inspector. 46CFR184.420
Documentation › Certificates/Documents › Letter of Substantial Compliance (DAPI)
Issued 27 November 2017
Resolved
Found DAPI program not in compliance, prove compliance to the satisfaction of attending Marine Inspector. 46CFR16
Communications › Radio Communications › VHF Radiotelephone
Issued 13 November 2017
Resolved
Emergency broadcast placard not accurate, update Emergency broadcast placard with accurate vessel info, to the satisfaction of the attending Marine Inspector. 46CFR184.506
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 10 October 2017
Resolved
Found pull cable to engine room fixed fire extinguishing system disconnected at ampoule location, reconnect pull cable.
Engineering › Fuel Oil Service System › Filter
Issued 10 October 2017
Resolved
Found fuel filter flame screen missing, install flame screen to the satisfaction of the attending marine inspector. 46 CFR 182.455
Communications › Radio Communications › VHF Radiotelephone
Issued 15 October 2015
Resolved
FCC Safety Radio Certificate expired 10OCT15. Vessel restricted to operating no more than 1000 feet from shore. Provide valid certificate to the attending Marine Inspector. 47 CFR 80.905
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 15 October 2015
Resolved
Visual Indicator Discharge light found inoperable. Make repairs to the satisfaction of the attending Marine Inspector. 46 CFR 181.420
Construction/Loadline › Hull › Bottom Plating
Issued 1 October 2015
Resolved
Hull damage on starboard side bow at chine. Scarf back to good material and make area available for inspection. Provide repair proposal to the Coast Guard.
Construction/Loadline › Hull › Bottom Plating
Issued 1 October 2015
Resolved
Make repairs to the starboard side hull damage at chine, to the satisfaction of the the attending Marine Inspector.
Engineering › Fuel Oil Service System › Valve
Issued 28 September 2015
Resolved
Main Diesel Engine fuel system did not have shut-off valves at the "engine end of the fuel line", non were located in the engine room. Properly install fuel shut-off valves in supply line to both MDE's. 46 CFR 182.20-40 (b)(3) (Old-T)
Engineering › Bilge Water Management System › Valve
Issued 28 September 2015
Resolved
Overboard discharge for bilges in the engine room do not have positive shut-off valves at the hull penetrations. Install valves to satisfaction of attending inspector. 46 CFR 182.520(e)(7)
Construction/Loadline › Structures › Transverse Bulkhead
Issued 28 September 2015
Resolved
Found open penetration in the engine room aft watertight bulkhead starboard side. Make watertight. 46 CFR 179.320
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 September 2015
Resolved
MDE's are missing belt guards. Install belt guards to satisfaction of attending inspector. 46 CFR 177.35-15
Fire Fighting › Ventilation Systems › Ducts
Issued 7 December 2009
Resolved
Submit to USCG proposal for securing engine room ventilation within 7 days
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 7 December 2009
Resolved
Renew/replace anchor cleat prior to next inspection
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 7 December 2009
Resolved
Replace one child sized lifejacket in kind
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 16 September 2008
Resolved
MAKE MAIN ENGINE EXHAUST PENETRATIONS THROUGH AFT BULKHEAD WATERTIGHT.
Lifesaving › Lifebuoys › Serviceable
Issued 16 September 2008
Resolved
REPAIR OR REPLACE LIFEBUOY AND MARK WITH VESSELS FULL NAME.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 25 September 2007
Resolved
Update the alcohol test kit, the existing kit is expired.
Communications › Visual Communication › Red Warning Signal
Issued 25 September 2007
Resolved
Provide one additional flare, there are only (11) onboard.
Lifesaving › Lifefloat › Float-free Link
Issued 25 September 2007
Resolved
Replace the weak links onthe life floats, the existing are incorrect size.
Engineering › Fuel Oil Service System › Filter
Issued 25 September 2007
Resolved
Replace the petcocks on the RACOR fuel filters with an approved type.
Engineering › Fuel Oil Service System › Filter
Issued 25 September 2006
Resolved
Provide metal plug/drains for both flame bowls on both MDE racor filter assemblies. They have the plastic plug/drains installed.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 25 September 2006
Resolved
Provide a lanyard for AFT deck hatch. Lanyard has parted and will allow the hatch cover to move freely in heavy weather if allowed.
Construction/Loadline › Structures › Deck Plating
Issued 25 September 2006
Resolved
Replace or sister cracked center longitudinal IWO FWD void OVHD, toward bow. Found a six inch crack in the 2 x 12 that runs the center line under the deck in the FWD void.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 8 September 2005
Resolved
Provide proof of MIS submission IAW 46CFR16.500 and a copy of letter of Regulatory Compliance from consortium IAW 46CFR16. They have a contract listing employees covered, but no MIS report submission mentioned in contract.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 September 2005
Resolved
Provide a corrosion resistant clip for float light on ring buoy. They had light tied to ring buoy.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 September 2005
Resolved
Provide a safety cage around fire pump pulley. They have one being fabricated.
Navigation › Piloting/Steering › US Coast Pilot
Issued 7 February 2005
Resolved
Provide vessel with a Coast Pilot.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 February 2005
Resolved
Provide the vessel with the Coast Guard Light List.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 February 2005
Resolved
Provide the vessel with the Tide/Tidal Current Tables.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 7 February 2005
Resolved
Provide vessel with the latest Local Notice to Mariners.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 7 February 2005
Resolved
Provide vessel with a proper first aid kit.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 7 February 2005
Resolved
Properly attach the water lights to the life floats with 18 ft. of line.
Lifesaving › Buoyant Apparatus › Marking
Issued 7 February 2005
Resolved
Stencil the life floats with the max. capacity.
Lifesaving › Buoyant Apparatus › Painter
Issued 7 February 2005
Resolved
Properly attach the sea painter to one of the life floats.
Fire Fighting › Nozzles › Condition
Issued 7 February 2005
Resolved
Provide a proper (brass) working nozzle for 3/4" hose.
Fire Fighting › Fire Pumps › Capacity
Issued 7 February 2005
Resolved
Provide a working hand pump with 5 GPM capacity required by OLD "T".
Communications › Radio Communications
Issued 15 March 2004
Resolved
PROVIDE FCC RADIO OPERATOR PERMIT. LEGACY COMPONENT DESC: Operators Permit
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 March 2004
Resolved
REPAIR/REPLACE FLOATING WATERLIGHT ON LIFERING PRIOR TO CARRIAGE OF PASSENGERS.
Lifesaving › Hand Flares › Quantity
Issued 15 March 2004
Resolved
PROVIDE 3 ADDITIONAL HAND HELD FLARES PRIOR TO CARRIAGE OF PASSENGERS.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 15 March 2004
Resolved
REPALCE REROFLECTIVE MATERIAL ON LIFERING/LIFEJACKETS AS NEEDED PRIOR TO CARRIAGE OF PASSENGERS.
Communications › Radio Communications
Issued 15 March 2004
Resolved
VESSEL RESTRICTED TO LIMITED COASTWISE LESS THAN 20 MILES FROM HARBOR OF SAFE REFUGE UNTIL SINGLE SIDE BAND REPAIRED AND REINSTALLED. LEGACY COMPONENT DESC: Radiotelephone Transceiver (2-27.5 MHz)
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 15 March 2004
Resolved
PROVIDE 1 ADDITIONAL MARINE TYPE B-II FIRE EXTINGUISHER PRIOR TO CARRIAGE OF PASSENGERS.
Engineering › Bilge Water Management System
Issued 15 March 2004
Resolved
REPAIR ENGINE ROOM HIGH LEVEL ALARM PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Alarms
Engineering › Freshwater System (jacketwater cooling)
Issued 15 March 2004
Resolved
REPAIR EXHAUST LAGGING ON STARBOARD ENGINE. LEGACY COMPONENT DESC: Exhaust Lagging
Communications › Radio Communications
Issued 15 March 2004
Resolved
UPDATE EPIRB REGISTRATION. LEGACY COMPONENT DESC: EPIRB
Construction/Loadline › Hull › Bottom Plating
Issued 19 January 2004
Resolved
REPAIR SOFT SPOTS ON HULL AS MARKED.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 January 2004
Resolved
REPAIR SMALL HOLE IN COLLISION BHD.
Construction/Loadline › Penetrations
Issued 19 January 2004
Resolved
REPAIR/REPLACE HEAD DISCHARGE VALVE. LEGACY COMPONENT DESC: Sea Valve
Engineering › Bilge Water Management System
Issued 19 January 2004
Resolved
REPAIR BILGE MANIFOLD SYSTEM VALVES OR INSTALL ELECTRICAL SUBMERSIBLE PUMPS IN EACH COMPARTMENT IAW 46CFR182.520. LEGACY COMPONENT DESC: Valve
Construction/Loadline › Hull › Bottom Plating
Issued 21 May 2002
Resolved
MAKE PERMANENT REPAIRS TO THREE SOFT SPOTS ON HULL BELOW WATERLINE AS MARKED.
Engineering › Bilge Water Management System
Issued 21 May 2002
Resolved
MAKE PERMANENT REPAIR TO BILGE PIPING SYSTEM IN CREW VOID. LEGACY COMPONENT DESC: Piping
Engineering › Bilge Water Management System
Issued 21 May 2002
Resolved
INSTALL POSITIVE CLOSURE DEVICE ON BILGE OVERBOARD DISHARGE. LEGACY COMPONENT DESC: Valve
Engineering › Fuel Oil Storage/Transfer System
Issued 21 May 2002
Resolved
CONDUCT HYDROSTATIC TEST OF BOTH FUEL TANKS. LEGACY COMPONENT DESC: Tank
Lifesaving › Buoyant Apparatus
Issued 4 March 2002
Resolved
REPAIR LIFEFLOAT STRAPS AND HAND ROPES AS NECESSARY.
Lifesaving › Buoyant Apparatus
Issued 4 March 2002
Resolved
REPLACE FLOATING WATERLIGHT ON LIFEFLOAT.
Communications › Alarms/Indicators
Issued 4 March 2002
Resolved
REPAIR VISUAL PORTION OF HIGH LEVEL BILGE ALARM. LEGACY COMPONENT DESC: Bilge Alarm
Stability › Watertight Integrity
Issued 4 March 2002
Resolved
MAKE FLUSH DECK HATCH IN PASSENGER COMPARTMENT WATERTIGHT.
Operations/Management › Drug and Alcohol Testing
Issued 4 March 2002
Resolved
PROVIDE CURRENT DRUG CONSORTIUM EMPLOYEE ASSISTANCE PROGRAM AND CURRENT CREW LIST.
Accommodation/Occupational Safety › Ventilation
Issued 4 March 2002
Resolved
REPAIR HOLES IN LIFEJACKET LOCKER ABOVE ENGINE ROOM.
Engineering › Fuel Oil Storage/Transfer System
Issued 4 March 2002
Resolved
CONDUCT HYDROSTATIC TEST OF FUEL TANKS PRIOR TO COMPLETION OF NEXT DRYDOCK. LEGACY COMPONENT DESC: Tank
Lifesaving
Issued 12 January 2001
Resolved
PROVIDE 9 HAND HELD FLARES PRIOR TO CARRIAGE OF PASSENGERS.
Construction/Loadline
Issued 12 January 2001
Resolved
REPAIR BILGE PIPING VALVE AT AFT GENERATOR ROOM BULKHEAD.
Lifesaving
Issued 12 January 2001
Resolved
PROPERLY REGISTER 406 MHZ EPIRB.
Construction/Loadline
Issued 12 January 2001
Resolved
REPAIR BILGE STRAINER IN LAZARETTE.
Lifesaving
Issued 12 January 2001
Resolved
PROVIDE AID TO ASSIST IN RETRIEVAL OF HELPLESS PERSON FROM THE WATER.
Engineering
Issued 12 January 2001
Resolved
PROPERLY INSTALL FLAME BOWLS ON FUEL STRAINERS.
Construction/Loadline
Issued 12 January 2001
Resolved
SISTER FIRST THREE FRAMES FWD OF PORT ENGINE ROOM VENT.
Navigation
Issued 12 January 2001
Resolved
REPAIR HORN.
Construction/Loadline
Issued 12 January 2001
Resolved
REPAIR AUDIO ALARM FOR HIGH LEVEL BILGE ALARM.
Deck/Cargo
Issued 12 June 2000
Resolved
MAKE PERMANENT REPAIRS TO FORWARD ANCHOR SUPPORT.
Construction/Loadline
Issued 12 June 2000
Resolved
REPLACE ROTTED WOOD IN WAY OF PORT/STARBOARD ENGINE ROOM VENTS.
Documentation
Issued 12 June 2000
Resolved
CORRECT CERTIFICATE OF DOCUMENTATION ADDRESS TO REFLECT ACTUAL OWNER'S ADDRESS.
Fire Fighting
Issued 14 March 2000
Resolved
PROPERLY INSTALL FIXED FIRE FIGHTING ELECTRICAL SYSTEM.
Construction/Loadline
Issued 14 March 2000
Resolved
INSTALL HIGH LEVEL BILGE ALARM IN SEWAGE COMPARTMENT.
Documentation
Issued 14 March 2000
Resolved
INITIATE CREW TRAINING/EPIRB MAINTENANCE LOGS.
Lifesaving
Issued 14 March 2000
Resolved
POST LIFEJACKET DONNING PROCEDURES.
Documentation
Issued 14 March 2000
Resolved
POST COI, ALL PAGES VISIBLE, BEHIND GLASS IN PILOT HOUSE PRIOR TO CARRIAGE OF PASSENGERS.
Unknown
Issued 14 March 2000
Resolved
PREPARE PASSENGER COUNT AND VOYAGE PLAN PRIOR TO EACH DEPARTURE.
Lifesaving
Issued 14 March 2000
Resolved
REPAIR RETROFLECTIVE MATERIAL ON 17 ADULT AND 03 CHILD-SIZE LIFEHACKETS PRIOR TO CARRIAGE OF PASSENGERS.
Documentation
Issued 14 March 2000
Resolved
PROVIDE FCC RADIOTELEPHONE CERTIFICATE AND FCC STATION LICENSE.
Documentation
Issued 14 March 2000
Resolved
PROVIDE DOCUMENTATION OF ENROLLMENT OF APPROVED DRUG CONSORTIUM.
Lifesaving
Issued 14 March 2000
Resolved
REPAIR LIFERING RETROFLECTIVE MATERIAL, PROPERLY INSTALL STROBE WITH CORROSION RESISTANT CLIP PRIOR TO CAARIAGE OF PASSENGERS.
Accommodation/Occupational Safety
Issued 14 March 2000
Resolved
REPAIR STBD PASSENGER COMPARTMENT WINDOW.
Documentation
Issued 14 March 2000
Resolved
POST WASTE MANAGEMENT PLAN
Lifesaving
Issued 14 March 2000
Resolved
ENROLL 50% OF CREW IN RED CROSS FIRST AID/CPR TRAINING.
Fire Fighting
Issued 26 March 1999
Resolved
DEMONSTRATE OPERATION OF FIXED FIRE EXTINGUISHING SYSTEM IN THE PRESENCE OFA CG MARINE INSPECTOR.
Lifesaving
Issued 5 March 1999
Resolved
Provide proof of battery installation/expiration date for EPIRB.
Documentation
Issued 5 March 1999
Resolved
Provide MIS report.
Documentation
Issued 5 March 1999
Resolved
Provide plans for fixed firefighting system and associated alarms and shut-downs.
Deck/Cargo
Issued 12 June 1998
Resolved
RENEW DRAIN HOSE FROM BAIT WELL TO OVERBOARD DISCHARGE.
Navigation
Issued 12 June 1998
Resolved
RENEW/REPLACE MOUNTING HARDWARE FOR HYDRAULIC LINE AFT STEERING ASSY.
Engineering
Issued 12 June 1998
Resolved
REPLACE FUEL FILTERS ON MAIN ENGINE FUEL SYSTEM
Navigation
Issued 12 June 1998
Resolved
RENEW MOUNTING HARDWARE IN RUDDER POST PACKING ASSY/STRUT BACKING PLATE AS REQUIRED.
Lifesaving
Issued 7 January 1998
Resolved
PRIOR TO CARRIAGE OF PASSENGERS ON AN OCEANS ROUTE, REPLACE OR REPAIR MALFUNCTIONING WATERLIGHT.
Documentation
Issued 7 January 1998
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving
Issued 7 January 1998
Resolved
RE-MARK LIFEFLOAT PADDLES WITH VSL'S NAME.
Lifesaving
Issued 27 January 1997
Resolved
PROCURE 4 WATERLIGHT BATTERIES AND INSTALL SAME.
Lifesaving
Issued 27 January 1997
Resolved
INSTALL ADEQUATE RETRO-REFLECTIVE MATERIAL ON ALL LIFERAFTS AND LIFERING.
Lifesaving
Issued 27 January 1997
Resolved
INSTALL BUOYANT LINE ON LIFERING.
Lifesaving
Issued 27 January 1997
Resolved
VSL LIMITED TO NO MORE THAN 20NM FROM SHORE PENDING SERVICING OF EPIRB HYDRO-STATIC RELEASE UNIT.
Fire Fighting
Issued 27 January 1997
Resolved
PROVIDE ANNUAL SERVICING OF ALL PORTABLE EXTINGUISHERS.
Deck/Cargo
Issued 13 May 1996
Resolved
REPLACE HYDRAULIC LINES TO ANCHOR WINDLASS MOTOR.
Construction/Loadline
Issued 13 May 1996
Resolved
REMOVE HYDRAULIC OIL/WATER MIX FROM CREW COMPT. BILGE.
Lifesaving
Issued 29 January 1996
Resolved
REPLACE FADED REFLECTIVE TAPE ON PFD'S AS NEEDED.
Documentation
Issued 29 January 1996
Resolved
PROVIDE PROOF OF THE FOLLOWING: AN EMPLOYEE ASSISTANCE PROGRAM, DRUG _x001C_ HOT-LINE PHONE NUMBER POSTED, A SIXTY (60) MINUTE DRUG AWARENESS TRAINING BRIEF FOR THE MASTER (SUPERVISORS), BASIC DRUG AWARENESS TRAINING FOR THE CREW, AND EACH EMPLOYEE ACKNOWLEDGE READING & SIGN COMPANY POLICY.
Fire Fighting
Issued 29 January 1996
Resolved
INSTALL GUARD OVER BELT DRIVE ON FIRE PUMP AND BILGE PUMP.
Fire Fighting
Issued 29 January 1996
Resolved
PRIOR TO CARRYING PASSENGERS SERVICE PORTABLE FIRE EXTINGUISHERS.
Lifesaving
Issued 6 January 1995
Resolved
Replace 4 lifefloat paddles.
Construction/Loadline
Issued 9 May 1994
Resolved
Install check valves in all bilge suction lines.
Construction/Loadline
Issued 9 May 1994
Resolved
Install ground strap on port rudder.
Lifesaving
Issued 10 January 1994
Resolved
Replace L/F waterlight.
Construction/Loadline
Issued 11 May 1992
Resolved
Mark and label all bilge valves.
Lifesaving
Issued 11 May 1992
Resolved
Tighten handrails
Engineering
Issued 11 May 1992
Resolved
Remove crimp in port engine exhaust hose.
Construction/Loadline
Issued 11 May 1992
Resolved
Rescale and arrest rust on bilge lines 4th compartment.
Construction/Loadline
Issued 11 May 1992
Resolved
Fill in holes in bulkhead in 3rd compartment.
Engineering
Issued 11 May 1992
Resolved
Remove crimp in fuel suction line port side.
Engineering
Issued 11 May 1992
Resolved
Renew exhaust lagging starboard engine, inboard side.
Navigation
Issued 7 January 1992
Resolved
REPAIR SSB RADIO.
Lifesaving
Issued 7 January 1992
Resolved
PROVIDE 1 ADDITIONAL ADULT PFD. VESSEL IS LIMITED TO 45 PASSENGERS UNTIL THIS ITEM IS COMPLETED.
Lifesaving
Issued 8 July 1991
Resolved
REPLACE ALL LIFE JACKET LIGHTS BY 30SEP91.
Documentation
Issued 4 February 1991
Resolved
PROVIDE GARBAGE MANAGEMENT PLAN BY 11FEB91.
Navigation
Issued 4 February 1991
Resolved
REPAIR ALL NAV LTS BY 04MAR91.
Navigation
Issued 4 February 1991
Resolved
REPLACE EPIRB BATTERY BY 30NOV91.
Lifesaving
Issued 4 February 1991
Resolved
REPLACE ALL LIFE JACKET LIGHTS BY 30SEP91.
Accommodation/Occupational Safety
Issued 4 February 1991
Resolved
INSTALL SIGN AND LOCK SEWAGE O/B VALVE. MUST BE LOCKED CLOSED WITHIN TERRITORIAL LIMITS.
Navigation
Issued 4 February 1991
Resolved
OVERHAUL STEERING LINAGE AT NEXT DRYDOCK OR 14NOV91.
Construction/Loadline
Issued 4 February 1991
Resolved
PROVIDE A CAPTIVE CHAIN - AFT HATCH BY 11FEB91.
Lifesaving
Issued 4 February 1991
Resolved
REPLACE 3 ORANGE FLARES BY 11FEB91.
Fire Fighting
Issued 4 February 1991
Resolved
PROVIDE SUCTION HOSE - HAND FIRE PUMP BY 11FEB91.
Navigation
Issued 4 February 1991
Resolved
DEMONSTRATE SSB PRIOR TO EXCEEDING 20 MILES AND BY 04MAR91.
Construction/Loadline
Issued 14 May 1990
Resolved
CREDITED DRYDOCK DUE 14NOV91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE.
Fire Fighting
Issued 22 March 1990
Resolved
PROVIDE 1 MARINE BRACKET - CO2.
Engineering
Issued 5 February 1990
Resolved
PROVIDE HEAT SHIELD KITS - RACOR FUEL FILTERS.
Lifesaving
Issued 5 February 1990
Resolved
MOUNT AND ATTACH RING BUOY LIGHT PRIOR TO CARRYING PASSENGERS.
Lifesaving
Issued 5 February 1990
Resolved
MOUNT AND ATTACH (18' LINE) 4 LIFEFLOAT LIGHTS PRIOR TO CARRYING PASSENGERS
Lifesaving
Issued 5 February 1990
Resolved
RENEW AND STENCIL 5 LIFEFLOAT PADDLES PRIOR TO VOYAGE OF OVER 20 MILES BUT NO LATER THAN 30 DAYS.
Fire Fighting
Issued 5 February 1990
Resolved
PROVIDE 3 MARINE BRACKETS - FIRE EXTINGUISHERS.
Accommodation/Occupational Safety
Issued 5 February 1990
Resolved
PROVIDE SEWAGE PUMP OUT. LOCK O/B VALVE.
Construction/Loadline
Issued 5 February 1990
Resolved
SEAL DECK OVER FUEL TANKS.
Engineering
Issued 5 February 1990
Resolved
INSTALL MUFFLER HANGERS.
Construction/Loadline
Issued 6 January 1989
Resolved
INSTALL CAPTURE CHAINS ON ALL WX DECK HATCHES.
Lifesaving
Issued 6 January 1989
Resolved
INSTALL 12' PENDENTS FOR EACH WEBBING STRAP ON LIFEBOATS.
Lifesaving
Issued 6 January 1989
Resolved
RENEW DETERIORATED WEBBING SRAPS ON LIFEBOATS AND RUN GRABLINE THROUGH EACH
Deck/Cargo
Issued 6 January 1989
Resolved
INSTALL VALVE HANDLES ON BILGE LINES IN LAZARETTE AND TANK ROOM/SPACE AND FREE UP VALVES.
Documentation
Issued 6 January 1989
Resolved
OBTAIN AND SUBMIT COPY OF FCC RADIO SAFETY CERTIFICATE.
Navigation
Issued 6 January 1989
Resolved
SUBMIT COPY OF RECEIPT OF 8" SHIPS BELL.
Lifesaving
Issued 6 January 1989
Resolved
REPLACE EPIRB BATTERY.
Navigation
Issued 6 January 1989
Resolved
MAKE/PROVE OPERATION OF SSB FOR FCC INSPECTION.
Fire Fighting
Issued 11 January 1988
Resolved
SERVICE FIRE EXTINGUISHERS.
Lifesaving
Issued 11 January 1988
Resolved
PROVIDE LIGHTS FOR CHILD LIFE PRESERVERS.
Fire Fighting
Issued 11 January 1988
Resolved
INSTALL GUARD ON BELT DRIVE FOR BILGE/FIRE PUMP.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.