Records from 1989 to 2004. Most recent: inspection, 29 April 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
29 April 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2055503
23 November 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 809600
25 January 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406431
6 November 1997
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466474
2 October 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783541
27 November 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422757
2 October 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452076
26 August 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1192556
11 January 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 669640
22 December 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212990
22 December 1994
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443527
28 September 1993
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387393
26 May 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 64456
23 June 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 948826
21 August 1991
Inclining Experiment · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1247648
27 December 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1228139
20 June 1990
Re-Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 924458
14 February 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1226040
6 December 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1218818
21 July 1989
Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350628
Unknown
Issued 27 December 1990
Resolved
PROVIDE ON BOARD A COAST GUARD ISSUED STABILITY LETTER.
Condition: Unknown
Due 27 December 1990
Resolved 27 December 1990
Unknown
Issued 21 July 1989
Resolved
INSTALL LOW HYDRAULIC OIL ALARM FOR JACKING SYSTEM.
Condition: Unknown
Due 21 July 1989
Resolved 21 July 1989
Deck/Cargo
Issued 21 July 1989
Resolved
PROVIDE ANCHOR WITH 270' LENGTH OF LINE.
Condition: Unknown
Due 21 July 1989
Resolved 21 July 1989
Unknown
Issued 21 July 1989
Resolved
INSTALL AND DEMONSTRATE OPERATION OF DEADMAN TYPE CONTROLS FOR JACKING SYSTEM.
Condition: Unknown
Due 21 July 1989
Resolved 21 July 1989
Engineering
Issued 21 July 1989
Resolved
INSTALL BILGE ALARM IN MACHINERY SPACE.
Condition: Unknown
Due 21 July 1989
Resolved 21 July 1989
Unknown
Issued 21 July 1989
Resolved
INSTALL REMOTE SHUT-DOWN FOR MACHINERY SPACE VENTILATION.
Condition: Unknown
Due 21 July 1989
Resolved 21 July 1989
Documentation
Issued 21 July 1989
Resolved
SUBMIT FOR APPROVAL THE FOLLOWING PLANS TO THE [name withheld]: (1) OUT BOARD AND INBOARD PROFILE PLANS, (2) GENERAL ARRANGEMENT, (3) HYDRAULIC JACKING SYSTEM, (4) HULL STRUCTURE, (5) INSTALLATION OF LEGS.
Condition: Unknown
Due 21 July 1989
Resolved 21 July 1989
Documentation
Issued 21 July 1989
Resolved
PROVIDE COAST GUARD APPROVED STABILITY AND OPERATIONAL MANUAL.
Condition: Unknown
Due 21 July 1989
Resolved 21 July 1989
Documentation
Issued 21 July 1989
Resolved
SUBMIT FOR APPROVAL PLANS FOR TILT ALARMS.
Condition: Unknown
Due 21 July 1989
Resolved 21 July 1989
Unknown
Issued 21 July 1989
Resolved
GUARDS ARE TO BE INSTALLED IN WAY OF ALL ROTATING MACHINERY.
Condition: Unknown
Due 21 July 1989
Resolved 21 July 1989