DOUBLE TROUBLE

DOUBLE TROUBLE is a 1982 passenger vessel (uninspected). The Coast Guard has recorded 9 inspections since 2016, most recently in July 2018, along with 11 deficiencies and 1 casualty investigation in 2012.

Records from 2012 to 2018. Most recent: inspection, 23 July 2018.

Built
1982
Last inspected
23 July 2018
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 July 2018
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH5762
213504
Flag
UNITED STATES
Maury page id
psix-213504

Documentation record

Tonnage as PSIX records it36 - Simplified, Net Ton
45 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

9 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

23 July 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6499399
29 March 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6383700
6 March 2018 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6366684
24 July 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6219690
5 May 2017 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6139952
7 February 2017 Administrative Inspection · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6083981
22 September 2016 Type not recorded
No type recorded · Station Gulfport · USCG Heartland District (CGD-H) · Activity 6007742
5 May 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5869818
3 March 2016 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5826197

Deficiency record · 11

Communications › Radio Communications › VHF Radiotelephone
Issued 5 July 2017 Resolved
Make operable GPS and MMSI on VHF Radio IAW 47 CFR 184.502. (Radio check done)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 24 July 2017
Resolution: The MMSI and GPS were properly uploaded/linked to the DSC capable VHF radio and found to be operating satisfactory.
Lifesaving › Launching Appliances › Davit
Issued 5 July 2017 Resolved
Replace davit cable IAW 46 CFR 182.100. (Wire showing wear and some barbs)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 24 July 2017
Resolution: The davit cable was replaced with new cable and found to be in satisfactory condition.
Engineering › Bilge Water Management System › Piping
Issued 5 July 2017 Resolved
Remove PVC bilge piping and replace with approved hose IAW 46 CFR 182.520.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 29 March 2018
Engineering › Steering Gear System › Rudder Stock
Issued 5 July 2017 Resolved
Adjust rudder packing IAW 46 CFR 182.610. (Leaking more than it should)
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 24 July 2017
Resolution: The shaft and rudder packings were adjusted and no excessive leaks were discovered.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 April 2016 Resolved
Wiring under console in pilot house, storage closet, throughout engine room, and lazarette space was not properly supported and had improper splices. Properly support all wiring with metal brackets and cap and enclose or remove dead ended wires. Properly splice all wiring where necessary and remove wire nuts.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 5 May 2016
Resolution: Wiring was supported with metal brackets, capped/enclosed and/or removed or properly spliced as needed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 April 2016 Resolved
Battery boxes in engine room were not secured in place and lids were not attached. Properly secure all battery boxes and lids.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 5 May 2016
Resolution: Battery boxes were secured with lids attached.
Stability › Watertight Integrity › General
Issued 5 April 2016 Resolved
Both shaft bearings leaked excessively while underway. Tighten or re pack glands to reduce water ingress.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 5 May 2016
Resolution: Shaft packings were tightened.
Engineering › Pressure Vessel › Safety Valve
Issued 5 April 2016 Resolved
Hot water heater had a pressure relief valve set at 150psi
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 5 May 2016
Resolution: Safety relief valve was replaced with one set at 100PSI.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 April 2016 Resolved
Emergency Lighting does not properly cover escape route from berthing area to accommodation space. Existing light does not actuate upon power loss. Make light actuate upon loss of power.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 5 May 2016
Resolution: One emergency lighting fixture was installed in the passageway; and all emergency lighting illuminated satisfactory.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 5 April 2016 Resolved
Vessel had outdated copy of navigation rules. Get a current copy of latest edition.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 5 May 2016
Resolution: Vessel had a new copy of the Navigation Rules onboard.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 April 2016 Resolved
Water light on life float was filled with water. Make watertight or replace with new light.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 5 May 2016
Resolution: A new waterlight was obtained and installed.