Records from 1986 to 2018. Most recent: inspection, 23 July 2018.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 July 2017
Resolved
Make operable GPS and MMSI on VHF Radio IAW 47 CFR 184.502. (Radio check done)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 24 July 2017
Resolution: The MMSI and GPS were properly uploaded/linked to the DSC capable VHF radio and found to be operating satisfactory.
Lifesaving › Launching Appliances › Davit
Issued 5 July 2017
Resolved
Replace davit cable IAW 46 CFR 182.100. (Wire showing wear and some barbs)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 24 July 2017
Resolution: The davit cable was replaced with new cable and found to be in satisfactory condition.
Engineering › Bilge Water Management System › Piping
Issued 5 July 2017
Resolved
Remove PVC bilge piping and replace with approved hose IAW 46 CFR 182.520.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 29 March 2018
Engineering › Steering Gear System › Rudder Stock
Issued 5 July 2017
Resolved
Adjust rudder packing IAW 46 CFR 182.610. (Leaking more than it should)
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 24 July 2017
Resolution: The shaft and rudder packings were adjusted and no excessive leaks were discovered.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 April 2016
Resolved
Wiring under console in pilot house, storage closet, throughout engine room, and lazarette space was not properly supported and had improper splices. Properly support all wiring with metal brackets and cap and enclose or remove dead ended wires. Properly splice all wiring where necessary and remove wire nuts.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 5 May 2016
Resolution: Wiring was supported with metal brackets, capped/enclosed and/or removed or properly spliced as needed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 April 2016
Resolved
Battery boxes in engine room were not secured in place and lids were not attached. Properly secure all battery boxes and lids.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 5 May 2016
Resolution: Battery boxes were secured with lids attached.
Stability › Watertight Integrity › General
Issued 5 April 2016
Resolved
Both shaft bearings leaked excessively while underway. Tighten or re pack glands to reduce water ingress.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 5 May 2016
Resolution: Shaft packings were tightened.
Engineering › Pressure Vessel › Safety Valve
Issued 5 April 2016
Resolved
Hot water heater had a pressure relief valve set at 150psi
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 5 May 2016
Resolution: Safety relief valve was replaced with one set at 100PSI.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 April 2016
Resolved
Emergency Lighting does not properly cover escape route from berthing area to accommodation space. Existing light does not actuate upon power loss. Make light actuate upon loss of power.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 5 May 2016
Resolution: One emergency lighting fixture was installed in the passageway; and all emergency lighting illuminated satisfactory.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 5 April 2016
Resolved
Vessel had outdated copy of navigation rules. Get a current copy of latest edition.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 5 May 2016
Resolution: Vessel had a new copy of the Navigation Rules onboard.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 April 2016
Resolved
Water light on life float was filled with water. Make watertight or replace with new light.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 5 May 2016
Resolution: A new waterlight was obtained and installed.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 11 July 2012
Resolved
Display a copy of the company's drug and alcohol policy and provide documentation of a Employee Assistance Program to include displaying drug and alcohol informational material and community service hot-line telephone numbers per 46 CFR 16.401(a).
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 11 July 2012
Resolved
Provide documentation that all supervisory personnel and crewmembers have received appropriate training per 46 CFR 16.401 (b).
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 11 July 2012
Resolved
Provide documentation that drug and alcohol background checks are being completed per 49 CFR 40.25.
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 2 October 2012
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 11 July 2012
Resolved
Provide a letter from the consortium listing all Chandeleur Charter's personnel that are enrolled with the company's consortium per 46 CFR 16.230.
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 2 October 2012
Resolution: [name withheld] faxed a copy from the Mississippi Charter Boat Captains Association listing all personnel working under Double Trouble
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 11 July 2012
Resolved
Provide documentation of pre-employment testing per 46 CFR 16.210.
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 11 July 2012
Resolved
Provide a copy of the MIS Report Confirmation of Filing Certificate from the company's drug consortium per 46 CFR 16.500.
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Personnel › Training › Rules of the Road
Issued 11 July 2012
Resolved
Provide current copy of the navigation rules of the road per 33CFR88.05
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 11 July 2012
Resolved
Provide marine radio operators permit for [name withheld] per 47CFR80.401
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Engineering › Fuel Oil Service System › Portable Fuel System
Issued 11 July 2012
Resolved
Provide new caps for the vessels portable fuel tanks or provide new portable fuel tanks per 46CFR147.45
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Lifesaving › Lifefloat › Lifeline
Issued 11 July 2012
Resolved
Replace all deteriorated life float line per 46 CFR 180.15-5 (line shall be not less than 3/8in diameter)
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 2 October 2012
Engineering › Steering Gear System › Hydraulic Hose
Issued 11 July 2012
Resolved
Replace all hydraulic hoses for the vessel's small boat lifting davit and all hydraulic hoses that are above the main deck for the anchor windlass using appropriated SAE J1942 hose per 46CFR182.10-1
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Engineering › Bilge Water Management System › Pump
Issued 11 July 2012
Resolved
Properly mount all submersible bilge pumps per 182.520 (e)(3)
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 11 July 2012
Resolved
Provide UL approved smoke detector in all passenger and crew berthing spaces per 46 CFR 181.400(e)
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 2 October 2012
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 July 2012
Resolved
Provide a satisfactory cover or electrical box to cover exposed solenoid in the head adjacent to the bunk rooms per 46CFR183.01-5
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 July 2012
Resolved
Provide an approved water light for the life float per 46CFR180.15-1
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 July 2012
Resolved
Provide manufacture approved batteries for all water lights per 46CFR185.726(d)
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Navigation › Piloting/Steering › Marine Charts
Issued 11 July 2012
Resolved
Provide adequate and up to date charts for areas the vessel operates per 46CFR184.420
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 11 July 2012
Resolved
Remove all traces of oil from the passenger berthing bilge per 46CFR 176.830
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 11 July 2012
Resolved
Remove flammable and combustible materials from the vessel or provide appropriate storage or a paint locker per 46 CFR 147.45
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Engineering › Bilge Water Management System › Hose
Issued 11 July 2012
Resolved
Provide an appropriate hose for the lazarette submersible bilge pump per 46CFR182.520(f)
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Fire Fighting › Ventilation Systems › Ducts
Issued 11 July 2012
Resolved
Repair all manual ventilation closures devices for spaces protected by a fixed gas extinguishing system per 46CFR182.465(h) and in accordance with 46CFR176.830
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 2 October 2012
Resolution: Hook was added in order to latch cover per CFR 176.830
Engineering › Fuel Oil Service System › Valve, Control
Issued 11 July 2012
Resolved
Relocate fuel shutoff valves outside the engine room per 46CFR182.20-40(b)(3) or provide shielding for the handle from flames per 46CFR182.455(b)(4)
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Electrical › Electric Generation Source (service) › Generator
Issued 11 July 2012
Resolved
Properly secure the stbd generator wiring cover on top of the generator per 46CFR183.10-10
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Electrical › Electrical Distribution System (service) › Switch
Issued 11 July 2012
Resolved
Repair the stbd generator main battery cutoff switch per 46 CFR183.05-35
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Engineering › Bilge Water Management System › Pump
Issued 11 July 2012
Resolved
Provide a portable bilge pump capable of pumping water from any compartment overboard per 46CFR182.25-10(e)
Action required: 705 - Other - as specified
Due 12 August 2012
Resolved 22 August 2012
Construction/Loadline › Hull › Keel
Issued 24 February 2010
Resolved
Tighten all keel bots throughout the keel and replace as needed.
Action required: 705 - Other - as specified
Due 4 March 2010
Resolved 4 March 2010
Resolution: All keel bolts were tightened as required and none were found in need of replacement.
Construction/Loadline › Hull › Bottom Plating
Issued 24 February 2010
Resolved
Replace the deteriorated chine and butt blocks in engine room starboard side as marked.
Action required: 705 - Other - as specified
Resolved 4 March 2010
Resolution: Repairs were made as required and found to be satisfactory.
Operations/Management › Drills/Instruction › Fire
Issued 15 July 2008
Resolved
Provide a current training manual with a description of the training topics.
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 13 August 2008
Resolution: Current Manual Provided.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 15 July 2008
Resolved
Provide a current life saving equipment maintenance manual.
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 13 August 2008
Resolution: Current Manual provided.
Engineering › Bilge Water Management System › Pump
Issued 15 July 2008
Resolved
Prove proper operation of the independent bilge pump in the engine room.
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 16 July 2008
Resolution: Bilge pump operational.
Engineering › Fuel Oil Service System › Piping
Issued 15 July 2008
Resolved
Make repairs to the fuel oil fill and return piping/lines to stop the fuel oil leak.
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 13 August 2008
Resolution: Repairs made to line; fuel is no longer leaking.
Engineering › Fuel Oil Service System › Filter
Issued 15 July 2008
Resolved
Provide and install a flame shield on the bottom of the fuel oil filter on the starboard side also provide and install a metal plug in the drain.
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 13 August 2008
Resolution: Flame shields provided and metal plug installed.
Engineering › Bilge Water Management System › Pump
Issued 15 July 2008
Resolved
Provide and install a bilge pump or a means to dewater the lazarette.
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 16 July 2008
Resolution: Bilge pump operational.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 15 July 2008
Resolved
Conduct maintenance on the port main propulsion engine to insure the engine idles properly.
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 16 July 2008
Resolution: Maintenance conducted, engine idled correctly.
Engineering › Fuel Oil Service System › Valve
Issued 15 July 2008
Resolved
Make repairs or replace the fuel shut off valve on the port fuel tank.
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 16 July 2008
Resolution: Repairs made and valve tested sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 15 July 2008
Resolved
Prove the shut down of the internal combustion engines for the pre-engineered fire suppression system in the engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 August 2008
Resolved 16 July 2008
Resolution: Shutoff valve tested and operational.
Engineering › Reduction Gearing/Clutches › Bolt
Issued 15 July 2008
Resolved
Replace the starboard gear shifting cable on the starboard reduction gear.
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 16 July 2008
Resolution: Cable shrink wrapped with double thick insulation.
Engineering › Steering Gear System › Ram
Issued 15 July 2008
Resolved
Tighten the retainer nuts on the steering hydraulic ram in the lazarette.
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 13 August 2008
Resolution: Retainer nuts tightened.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 July 2008
Resolved
Replace the lens on the forward mast light .
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 13 August 2008
Resolution: Lens replaced, light watching properly.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 July 2008
Resolved
Provide a coast guard approved first aid kit.
Due 15 August 2008
Resolved 13 August 2008
Resolution: First aid kit provided.
Construction/Loadline › Hull › Side Shell
Issued 22 February 2008
Resolved
Properly cover all uncovered bolts in the chine as per 46 CFR 176.610 and NVIC 7-95.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2008
Resolution: All fasteners in the hull have been properly plugged and sealed.
Construction/Loadline › Hull › Side Shell
Issued 22 February 2008
Resolved
Arrest and repair rot on the rotted chine plank on the port bow as per 46 CFR 176.610 and NVIC 7-95.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2008
Resolution: The end of the plank has been sanded back to good wood and the gap has been properly sealed.
Construction/Loadline › Hull › Side Shell
Issued 22 February 2008
Resolved
Replace the rotten boards on the starboard bow, 3 boards down from the chine as per 46 CFR 176.610 and NVIC 7-95.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2008
Resolution: This area has been properly repaired with 3 new planks.
Construction/Loadline › Hull › Sheerstrake
Issued 22 February 2008
Resolved
Replace the rotten boards on the starboard side sheer strake as per 46 CFR 176.610 and NVIC 7-95.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2008
Resolution: These boards have been replaced satisfactorily.
Construction/Loadline › Hull › Side Shell
Issued 22 February 2008
Resolved
Repair rot around starboard sewage raw water intake as per 46 CFR 176.610 and NVIC 7-95.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2008
Resolution: The plank that contained the rot has been properly replaced.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 22 February 2008
Resolved
Secure stern ladder hand rails as per 46 CFR 177.900.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2008
Resolution: These items have been properly secured to the vessel.
Construction/Loadline › Hull › Side Shell
Issued 22 February 2008
Resolved
Replace marked butt block located in engine room, port side, mid body on bulkhead below circle mark on bulkhead as per 46 CFR 176.610 and NVIC 7-95.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2008
Resolution: The butt block has been properly replaced.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 2 July 2007
Resolved
Remove all used motor oil in buckets and all rubbish from the bilges of the engine room as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 2 August 2007
Resolved 18 July 2007
Resolution: Removed listed items.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 2 July 2007
Resolved
Replace and or tighten the bolts on the port and starboard main engine as instructed as per 46 CFR 176.8000.
Action required: 705 - Other - as specified
Due 2 August 2007
Resolved 18 July 2007
Resolution: Replaced and tightened bolts.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 2 July 2007
Resolved
Make repairs to the fuel oil fill line and the return lines to stop leaks in way of piping with epoxy and leaks as per 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 2 August 2007
Resolved 18 July 2007
Resolution: Replaced fuel oil fill line and tightened return lines.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 2 July 2007
Resolved
Install disconnect switches as per 46 CFR 183.380 in the cabling/wiring from the batteries and starters.
Action required: 705 - Other - as specified
Due 2 August 2007
Resolved 18 July 2007
Resolution: Installed disconnect switches.
Engineering › Lubricating Oil Service System › Flange
Issued 2 July 2007
Resolved
Make repairs to both the port and starboard main engines to stop lube oil leaks as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 2 August 2007
Resolved 18 July 2007
Resolution: Replaced gaskets on inspection covers to stop leaks.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 July 2007
Resolved
Properly support the port main engine exhaust piping and make repairs to secure the leak as per 46 CFR 182.430.
Action required: 705 - Other - as specified
Due 2 August 2007
Resolved 18 July 2007
Resolution: Supported exhaust piping and repaired the leak in the line.
Engineering › Steering Gear System › Rudder
Issued 2 July 2007
Resolved
Tighten the packing gland on the starboard rudder post.
Action required: 705 - Other - as specified
Due 2 August 2007
Resolved 18 July 2007
Resolution: Tightened packing gland.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 2 July 2007
Resolved
Replace the retroreflective tape on the child life jacket as per 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 2 August 2007
Resolved 18 July 2007
Resolution: Replaced retroreflective tape on the child life jacket.
Lifesaving › Lifefloat › Painter
Issued 2 July 2007
Resolved
Replace the sea painter on the life float as per 46 CFR 180.160.
Action required: 705 - Other - as specified
Due 2 August 2007
Resolved 18 July 2007
Resolution: Replaced sea painter on the life float.
Lifesaving › Lifefloat › Paddle
Issued 2 July 2007
Resolved
Properly attach the paddles to the life float and properly mark as per 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 2 August 2007
Resolved 18 July 2007
Resolution: Attached paddles to the life float.
Communications › Radio Communications › EPIRB
Issued 2 July 2007
Resolved
Prove the expiration date of the battery on the EPIRB as per 46 CFR 180.64.
Action required: 705 - Other - as specified
Due 2 August 2007
Resolved 3 July 2007
Resolution: Provide a new EPRIB
Documentation › Certificates/Documents › FCC SSL
Issued 19 April 2006
Resolved
Provide a radio safety certificate in accordance with 47 CFR 902.
Due 19 May 2006
Resolved 26 April 2006
Resolution: The required safety certificate was onboard.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 19 April 2006
Resolved
Provide a current training book in accordance with 46 CFR185.420.
Due 19 May 2006
Resolved 26 April 2006
Resolution: A training log was onboard.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 19 April 2006
Resolved
Provide a life saving equipment maintenance record in accordance with 46 CFR 185.702.
Due 19 May 2006
Resolved 26 April 2006
Resolution: A life saving equipment was placed onboard the vessel.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 19 April 2006
Resolved
Provide a current bridge log with the required entries in accordance with 46 CFR 185.702.
Due 19 May 2006
Resolved 26 April 2006
Resolution: A bridge log was placed onboard the vessel.
Navigation › Piloting/Steering › Marine Charts
Issued 19 April 2006
Resolved
Provide current charts of the area of operation in accordance with 46 CFR 184.420.
Due 19 May 2006
Resolved 26 April 2006
Resolution: New charts were placed onboard the vessel.
Communications › Radio Communications › EPIRB
Issued 19 April 2006
Resolved
Prove the EPIRB is registered in accordance with 46 CFR 185.728.
Due 19 May 2006
Resolved 26 April 2006
Resolution: The EPIRB had a NOOA registration sticker on it.
Communications › Radio Communications › EPIRB
Issued 19 April 2006
Resolved
Provide and install a new hydrostatic release for the EPIRB.
Due 19 May 2006
Resolved 26 April 2006
Resolution: A new hydrostatic release was installed.
Lifesaving › Lifefloat › Serviceable
Issued 19 April 2006
Resolved
Have the life float serviced by an approved servicing facility or replace.
Due 19 May 2006
Resolved 26 April 2006
Resolution: The owner bought a new life float to replace the deteriorated life float.
Lifesaving › Lifefloat › Float Free
Issued 19 April 2006
Resolved
Relocate the life float to an area where it will be able to float free if needed in accordance with 46 CFR 180.130.
Due 19 May 2006
Resolved 30 May 2006
Resolution: The life float was relocate.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 19 April 2006
Resolved
Prove proper operation of the emergency lights in the forward berthing in accordance with 46 CFR 183.432.
Due 19 May 2006
Resolved 26 April 2006
Resolution: The lights were operational.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 April 2006
Resolved
Provide and install protective covers over the glass globes for the light through out the vessel.
Due 19 May 2006
Resolved 30 May 2006
Resolution: Protective covers were installed.
Lifesaving › Lifebuoys › Serviceable
Issued 19 April 2006
Resolved
Replace the deteriorated life ring.
Due 19 May 2006
Resolved 26 April 2006
Resolution: A new life ring bought and placed onboard the vessel.
Engineering › Diesel Engine (propulsion-reduction gear) › Air-flex Clutch
Issued 19 April 2006
Resolved
Prove proper operation of the port main engine and clutch assembly it has no reverse.
Due 19 May 2006
Resolved 30 May 2006
Resolution: Repairs were made and the engine was properly tested.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 19 April 2006
Resolved
Properly secure all batteries in the engine room.
Due 19 May 2006
Resolved 30 May 2006
Resolution: The batteries were properly secured.
Electrical › Electric Generation Source (service) › Generator
Issued 19 April 2006
Resolved
Prove the 40 degree Celsius generator has been derated in accordance with 46 CFR 183.320.
Due 19 May 2006
Resolved 30 May 2006
Resolution: The generator was properly derated.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 April 2006
Resolved
Provide guards over all rotating machinery in the engine room for both main engines and the generator in accordance with 46 CFR 177.960.
Due 19 May 2006
Resolved 30 May 2006
Resolution: Guards were install on both main engines and the generator.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 April 2006
Resolved
Provide and install a locking device for the oven door in accordance with 46 CFR 184.220.
Due 19 May 2006
Resolved 30 May 2006
Resolution: A locking device was installed on the oven door.
Fire Fighting › Fire Bucket › Availability
Issued 19 April 2006
Resolved
Provide three 2.5 gals. fire buckets in accordance with 46 CFR 181.610.
Due 19 May 2006
Resolved 19 April 2006
Resolution: Three buckets were purchased and placed onboard the vessel.
Stability › Weathertight Integrity › General
Issued 17 March 2006
Resolved
Prove proper operation of watertight hatch leading from the deck to the lazarette as required by 46 CFR 179.115
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 30 May 2006
Resolution: Proved operation of watertight hatch.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 17 March 2006
Resolved
Make proper weld repair to anchor hawse/guide in way of the broken welds as required by 46CFR176.800.
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 30 May 2006
Resolution: Repaired hawse guide.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 17 March 2006
Resolved
Make repairs to anchor windless mounts.
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 30 May 2006
Resolution: Repaired windless mounts.
Construction/Loadline › Structures › Deck Plating
Issued 17 March 2006
Resolved
Make repairs to the deck under the lifejacket stowage area on the starboard side above the engine room.
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 30 May 2006
Resolution: Repaired deck above engine room.
Communications › Alarms/Indicators › High Water Alarm
Issued 7 June 2005
Resolved
Provide high water alarm in Lazarette IAW 46CFR182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2005
Resolution: High water alarm installed and tested.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 June 2005
Resolved
Relocate and repair or renew mast headlight IAW colregs prior to carrying passengers at night.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2005
Resolution: Light relocated to improve visibility and cracked cover replaced.
Stability › Weathertight Integrity › General
Issued 7 June 2005
Resolved
Tether forepeak hatch to vessel in IAW 46CFR171.124
Action required: 705 - Other - as specified
Due 7 August 2005
Resolved 30 June 2005
Resolution: Chain attached to cover.
Electrical › Electric Generation Source (service) › Generator
Issued 7 June 2005
Resolved
Provide working ammeter for generator IAW 46CFR183-10(g)
Action required: 705 - Other - as specified
Due 7 July 2005
Resolved 30 June 2005
Resolution: Ammeter operational.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 7 June 2005
Resolved
Splice waterlight to line for life float IAW 46CFR180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2005
Resolution: Waterlight line spliced to lifefloat line.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 June 2005
Resolved
Renew or repair bilge pump indicator light for engine room IAW 46CFR182.25-10
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2005
Resolution: Light operational.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 June 2005
Resolved
Provide eyewash IAW 46CFR160.041
Action required: 705 - Other - as specified
Due 7 July 2005
Resolved 30 June 2005
Resolution: Eyewash replaced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 June 2005
Resolved
Renew or repair stern light IAW COLREGS prior to carrying passengers at night
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2005
Resolution: Stern light circuit identified and owner has taken measures to ensure that it will be energized when other nav lights are on.
Communications › Radio Communications › VHF Radiotelephone
Issued 6 July 2004
Resolved
Provide FCC Marine Radio Operator Permit per 47 CFR 80.
Due 6 August 2004
Resolved 28 July 2004
Resolution: FCC Marine Radio Operator Permit was provided.
Documentation › Logs/Records › Logbook (official)
Issued 6 July 2004
Resolved
Provide logbook for the vessel that documents crew training, with the date of training & general topic & list of names for who participated; abandonship/man overboard/fire drills, and monthly inspection of life float and EPIRB per 46 CFR 185.702
Due 6 September 2004
Resolved 28 July 2004
Resolution: The proper logbooks were provided.
Lifesaving › Lifefloat › Serviceable
Issued 6 July 2004
Resolved
Secure pendants on life float with line that is easy to break per 46 CFR 180.175(f)(1).
Due 6 August 2004
Resolved 28 July 2004
Resolution: The pendants were satisfactorily secured.
Lifesaving › Lifefloat › Serviceable
Issued 6 July 2004
Resolved
Secure paddles to the lifefloat. 46 CFR 180.175(f)(3).
Due 6 August 2004
Resolved 28 July 2004
Resolution: The paddles were tethered to the life float.
Lifesaving › Lifefloat › Serviceable
Issued 6 July 2004
Resolved
Provide paddles that are at least 4 feet long per 46 CFR 180.175(f)(2).
Due 6 August 2004
Resolved 28 July 2004
Resolution: Satisfactory paddles were supplied.
Lifesaving › Lifefloat › Serviceable
Issued 6 July 2004
Resolved
Remark the lifefloat with the vessel's name and capacity per 46 CFR 185.604(c).
Due 6 August 2004
Resolved 28 July 2004
Resolution: Lifefloat was properly marked with the vessel''s name and capacity.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 6 July 2004
Resolved
Demonstrate proper operation of the override switch for the fixed fire extinguishing system on the port engine per 46 CFR 181.420.
Due 6 August 2004
Resolved 28 July 2004
Resolution: Override switch on port engine operated satisfactorily.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 6 July 2004
Resolved
Provide shutdowns from the fixed fire extinguishing system to the generator & power ventilation per 46 CFR 181.420(a)(3).
Due 6 August 2004
Resolved 28 July 2004
Resolution: Shutdowns for generator and power ventilation operated satisfactorily.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 July 2004
Resolved
Provide visual indicator for the automatic bilge pumps at the operating station per 46 CFR 182.530(c).
Due 6 August 2004
Resolved 28 July 2004
Resolution: Visual indicators for automatic bilge pumps satisfactory.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 6 July 2004
Resolved
Remove all combustible/flammable products scattered throughout the vessel and place in proper storage space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2004
Resolved 28 July 2004
Resolution: All combustable and flammable products removed from vessel.
Communications › Radio Communications › EPIRB
Issued 6 July 2004
Resolved
Replace EPIRB battery per 46 CFR 184.502 & 47 CFR 80. Vessel is limited to operating no more than 3 nm from shore.
Due 7 July 2004
Resolved 28 July 2004
Resolution: EPIRB battery replaced.
Construction/Loadline › Hull › Bottom Plating
Issued 6 July 2004
Resolved
Permanently repair leak under the port rudder block.
Due 31 December 2004
Resolved 24 March 2005
Resolution: New rudder plates and rudder blocks were installed as well as rudders glands were repacked. SAT
Construction/Loadline › Hull › Hull Plating
Issued 6 July 2004
Resolved
Make vessel ready for fastener exam. Vessel must be out of the water & marine inspector contacted to examine hull and identify which fasteners to pull, if necessary.
Due 31 December 2004
Resolved 24 March 2005
Resolution: Examined vessel and saw no reason to pull fasteners IAW CID Memo 05-12. Recommend fasteners be examined at next drydock in 2006.
Lifesaving › Hand Flares › Expired
Issued 6 July 2004
Resolved
Provide required number of day & night time signal devices per 46 CFR 180.68.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2004
Resolved 6 July 2004
Resolution: 6 day and 6 night time signal devices with proper expiration date where provided prior to completion of exam.
Lifesaving › Lifefloat › Float Free
Issued 6 July 2004
Resolved
Provide proper weak link for lifefloat per 46 CFR 180.175(d).
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2004
Resolved 6 July 2004
Resolution: Weak link found and properly attached.
Construction/Loadline › Hull › Hull Plating
Issued 6 July 2004
Resolved
Make repairs to the port rudder block.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2004
Resolved 6 July 2004
Resolution: Temporary repairs completed to port rudder block.
Construction/Loadline › Hull
Issued 18 March 2004
Resolved
Replace in kind butt block located in the steering space, port side, under fresh water tank.
46 CFR 177.300
Due 18 April 2004
Resolved 23 March 2004
Resolution: Replacement butt block found satisfactory.
Stability › Watertight Integrity
Issued 18 March 2004
Resolved
Cap pipe that penetrates aft bulkhead starboard side of engine room.
46 CFR 179.320
Due 18 April 2004
Resolved 23 March 2004
Resolution: Cap installed and found satisfactory.
Electrical › Lighting (emergency)
Issued 18 March 2004
Resolved
Prove proper operation of emergency lighting in aft berthing.
46 CFR 183.432
Due 18 April 2004
Resolved 23 March 2004
Resolution: Emergency lighting operationally test with no problems noted.
Stability › Watertight Integrity
Issued 18 March 2004
Resolved
Cap pipe that penetrates forward bulkhead of engine room, port side.
46 CFR 179.320
Due 18 April 2004
Resolved 23 March 2004
Resolution: Cap installed and found satisfactory.
Electrical › Electrical Distribution System (service)
Issued 18 March 2004
Resolved
Secure wiring in aft berthing.
46 CFR 183.340 LEGACY COMPONENT DESC: Wiring
Due 18 April 2004
Resolved 23 March 2004
Resolution: Wiring examined and found properly secured with no problems noted.
Accommodation/Occupational Safety › Medical/First Aid
Issued 10 July 2003
Resolved
Provide Red Cross First Aid/CPR card for 50% of crew.
Due 10 August 2003
Resolved 22 July 2003
Resolution: Owner provided valid First Aid & CPR cards.
Communications › Radio Communications
Issued 10 July 2003
Resolved
Provide hydrostatic release for EPIRB. 46CFR 180.64. LEGACY COMPONENT DESC: EPIRB
Due 10 August 2003
Resolved 22 July 2003
Resolution: Valid hydrostatic release installed.
Communications › Radio Communications
Issued 10 July 2003
Resolved
Provide proof of NOAA registration. 47 CFR part 80. LEGACY COMPONENT DESC: EPIRB
Due 10 August 2003
Resolved 22 July 2003
Resolution: EPIRB has valid NOAA registration sticker.
Communications › Radio Communications
Issued 10 July 2003
Resolved
[name withheld] with vessel name 46 CFR 185.604(c). LEGACY COMPONENT DESC: EPIRB
Due 10 August 2003
Resolved 10 August 2003
Lifesaving › Buoyant Apparatus
Issued 10 July 2003
Resolved
Replace lifeline at life float. 46 CFR 180.175.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2003
Resolved 22 July 2003
Resolution: Life line at life float replaced.
Lifesaving › Buoyant Apparatus
Issued 10 July 2003
Resolved
Secure paddles to life float. 46CFR 180.175(2).
Due 10 August 2003
Resolved 22 July 2003
Resolution: Paddles were secured to the life float.
Communications › Radio Communications
Issued 20 June 2002
Resolved
Replace battery on EPIRB as per 46 CFR 180.15. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 26 June 2002
Resolved 26 June 2002
Communications › Radio Communications
Issued 20 June 2002
Resolved
Replace hydrostatic release on EPIRBas per 46 CFR 180.15. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 26 June 2002
Resolved 26 June 2002
Communications › Radio Communications
Issued 20 June 2002
Resolved
Provide proper FCC documentation as (safety radio equipment certificate) required by 47CFR88. LEGACY COMPONENT DESC: VFH Radiotelephone
Action required: 705 - Other - as specified
Due 26 June 2002
Resolved 26 June 2002
Fire Fighting › Miscellaneous Items
Issued 20 June 2002
Resolved
Provide three fire buckets.
Action required: 705 - Other - as specified
Due 26 June 2002
Resolved 26 June 2002
Fire Fighting › Water Fog Applicators
Issued 20 June 2002
Resolved
Unknown Component - Missing
Action required: 705 - Other - as specified
Resolved 26 June 2002
Communications › Alarms/Indicators
Issued 20 June 2002
Resolved
Provide audible bilge alarm on pilot house console as required by 46 CFR 182.530 LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 26 June 2002
Resolved 26 June 2002
Engineering › Shafting/Propeller Arrangements
Issued 28 February 2002
Resolved
RE-FASTEN PLATE AROUND STERN TUBE PORT AND STBD. LEGACY COMPONENT DESC: Stern Tube
Due 28 March 2002
Resolved 6 March 2002
Resolution: Worklist item see narrative for details.
Pollution Prevention/Response › Prevention Equipment
Issued 28 February 2002
Resolved
REMOVE OIL AND WATER FROM BILGE IN ENGINE ROOM AND MAKE READY FOR INSPECTION. LEGACY COMPONENT DESC: Oily Mixture Discharge Fixed Piping System
Due 28 March 2002
Resolved 6 March 2002
Resolution: Worklist item see narrative for details.
Construction/Loadline › Hull
Issued 28 February 2002
Resolved
CAULK PLANKS IN STERN OF VESSEL. LEGACY COMPONENT DESC: Side Shell
Due 28 March 2002
Resolved 6 March 2002
Resolution: Worklist item see narrative for details.
Construction/Loadline › Hull
Issued 28 February 2002
Resolved
CAULK PLANKS AT STBD SIDE AFT IN WAY OF BULKHEAD BETWEEN STEERING ROOM AND ENGINE ROOM. LEGACY COMPONENT DESC: Side Shell
Due 28 March 2002
Resolved 6 March 2002
Resolution: Worklist item see narrative for details.
Engineering › Shafting/Propeller Arrangements
Issued 28 February 2002
Resolved
REPLACE FWD STRUT BEARINGS PORT AND STBD. LEGACY COMPONENT DESC: Bearing
Condition: Unknown
Due 28 March 2002
Resolved 6 March 2002
Resolution: Worklist item see narrative for details.
Construction/Loadline › Hull
Issued 28 February 2002
Resolved
RE-CAULK HULL WERE NEEDED. LEGACY COMPONENT DESC: Side Shell
Due 28 March 2002
Resolved 6 March 2002
Resolution: Worklist item see narrative for details.
Fire Fighting
Issued 20 June 2000
Resolved
PROVIDE SERVICING OF ALL PORTABLE AND FIXED FIRE SYSTEMS AS REQUIRED BY 46 CFR 176.810(b)(1)
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Electrical
Issued 20 June 2000
Resolved
PROVIDE PROPER INSTALLATION OF ELECTRICAL WIRING AS REQUIRED BY 46 CFR 183.10-20
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Fire Fighting
Issued 27 April 1999
Resolved
PROVIDE PROPER INSTALLATION OF FIXED FIRE FIGHTING SYSTEM AS REQUIRED BY 46CFR 181.400.
Condition: Unknown
Due 27 May 1999
Resolved 2 July 1999
Fire Fighting
Issued 27 April 1999
Resolved
PROVIDE POWER VENTILATION SHUTDOWN FOR ENGINE ROOM EXHAUST BLOWER AS REQUIRED BY 46 CFR 181.420.
Condition: Unknown
Due 27 May 1999
Resolved 2 July 1999
Fire Fighting
Issued 27 April 1999
Resolved
PROVIDE MANUAL VENTILATION CLOSURES ON ENGINE ROOM VENT INTAKE/EXHAUST AS REQUIRED BY 46 CFR 182.465(H)
Condition: Unknown
Due 27 May 1999
Resolved 2 July 1999
Lifesaving
Issued 27 April 1999
Resolved
PROVIDE HIGH LEVEL BILGE ALARMS AS REQUIRED BY 46 CFR 182.530.
Condition: Unknown
Due 27 May 1999
Resolved 2 July 1999
Electrical
Issued 27 April 1999
Resolved
REPAIR WIRING AND ELECTRICAL INSTALLATIONS AS REQUIRED BY 46 CFR 183.10-20.
Condition: Unknown
Due 27 May 1999
Resolved 2 July 1999
Electrical
Issued 27 April 1999
Resolved
REPLACE GUARDS ON LIGHTING FIXTURES AS REQUIRED BY 46 CFR 183.01-5.
Condition: Unknown
Due 27 May 1999
Resolved 2 July 1999
Lifesaving
Issued 27 April 1999
Resolved
REPLACE HYDROSTATIC RELEASE ON E-PIRB AND RENEW REGISTRATION AS REQUIRED BY46 CFR 185.728.
Condition: Unknown
Due 27 May 1999
Resolved 2 July 1999
Lifesaving
Issued 27 April 1999
Resolved
PROVIDE EMERGENCY TRAINING AND LOG SAME AS REQUIRED BY 46 CFR 176.808 AND 46 CFR 185.420.
Condition: Unknown
Due 27 May 1999
Resolved 2 July 1999
Navigation
Issued 6 April 1998
Resolved
TIGHTEN RUDDER PACKING TO REDUCE LEAKAGE AS PER 46 CFR 176.814.
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Lifesaving
Issued 6 April 1998
Resolved
PROVIDE VALID RED CROSS FIRST AID CARD FOR 50% PF DECKHANDS. NVIC 1-91
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Fire Fighting
Issued 3 April 1997
Resolved
THE VESSEL DID NOT HAVE AN EXTRA PORTABLE FIRE EXTINGUISHER TO PROTECT THE SKIFF PORTABLE GASOLINE CAN AREA. PROVIDE THE EXTINGUISHER IN ACCORDANCE WITH CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Engineering
Issued 3 April 1997
Resolved
THE VESSEL'S MAIN FUEL TANK WAS NOT GROUNDED PROPERLY. PROPERLY GROUND THETANK IN ACCORDANCE WITH 46 CFR 182.440(b)(4) PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Electrical
Issued 3 April 1997
Resolved
THE VESSEL'S ENGINEROOM LIGHTING FIXTURES WERE MISSING ONE (1) GLOBE AND THREE (3) GLOBE GUARDS. REPAIR FIXTURES IN ACCORDANCE WITH 46 CFR 183.410 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Navigation
Issued 3 April 1997
Resolved
THE VESSEL'S CHARTS AND PUBLICATIONS WERE EITHER OUTDATED OR MISSING. PROVIDE UP-TO-DATE CHARTS AND PUBLICATIONS IN ACCORDANCE WITH 46 CFR 184.420 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Accommodation/Occupational Safety
Issued 3 April 1997
Resolved
THE VESSEL'S MARINE SANITATION DEVICE DID NOT HAVE A 3/4 FULL BY VOLUME INDICATOR. PROVIDE AN INDICATOR IN ACCORDANCE WITH 33 CFR 159.83 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Deck/Cargo
Issued 3 April 1997
Resolved
THE VESSEL'S SKIFF BOOM CABLE WAS EXCESSIVELY WORN. REPLACE CABLE PRIOR TOCOMPLIANCE DATE.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Fire Fighting
Issued 3 April 1997
Resolved
THE VESSEL DID NOT HAVE THREE (3) 2.5 GALLON FIRE BUCKETS. PROVIDE BUCKETSIN ACCORDANCE WITH 46 CFR 181.610 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Construction/Loadline
Issued 3 April 1997
Resolved
THE VESSEL'S PORT RUDDER POST WAS LEAKING WATER. REPAIR LEAK IN ACCORDANCEWITH 46 CFR 176.814 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Lifesaving
Issued 3 April 1997
Resolved
THE VESSEL'S DISTRESS SIGNALS WERE NOT STORED IN A PORTABLE WATERTIGHT CONTAINER. PROVIDE A CONTAINER IN ACCORDANCE WITH 46 CFR 180.68(d)(1) PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Lifesaving
Issued 3 April 1997
Resolved
THE VESSEL'S WATERTIGHT CONTAINER FOR DISTRESS SIGNALS MUST BE MARKED WITH "DISTRESS SIGNALS". MARK CONTAINER IN ACCORDANCE WITH 46 CFR 185.614 PRIORTO COMPLIANCE DATE.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Lifesaving
Issued 3 April 1997
Resolved
THE VESSEL'S LIFE FLOAT WAS MISSING A PADDLE. PROVIDE AND PROPERLY MARK A PADDLE IN ACCORDANCE WITH 46 CFR 180.175(e)(2) AND 185.604(g) PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Lifesaving
Issued 3 April 1997
Resolved
THE VESSEL DID NOT HAVE A USCG APPROVED OR EQUIVALENT FIRST AID KIT. PROVIDE A FIRST AID KIT IN ACCORDANCE WITH 46 CFR 184.710 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Lifesaving
Issued 3 April 1997
Resolved
THE OPERATOR WAS UNABLE TO PRODUCE EVIDENCE OF 50% OF DECKHANDS HAVING HAD CPR TRAINING. PROVIDE EVIDENCE OF THE TRAINING IN ACCORDANCE WITH NVIC _x001C_ 1-91 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Electrical
Issued 11 April 1991
Resolved
INSTALL FREQUENCY, VOLTMETER AND AMMETER FOR GENERATOR
Condition: Unknown
Due 11 April 1991
Resolved 11 April 1991
Electrical
Issued 11 April 1991
Resolved
INSTALL AUTOMATICALLY OPERATED EMERGENCY LIGHT FOR ESCAPE HATCH LEADING FROM LEADING FROM LOUNGE AREA BELOW MAIN DECK_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 April 1991
Resolved 11 April 1991
Engineering
Issued 11 April 1991
Resolved
INSTALL PROTECTIVE GUARDS AROUND BELTS ON GENERATOR AND STBD ENGINE
Condition: Unknown
Due 11 April 1991
Resolved 11 April 1991
Electrical
Issued 11 April 1991
Resolved
PROVIDE COVERS FOR BATTERY BOXES IN ENGINE ROOM
Condition: Unknown
Due 11 April 1991
Resolved 11 April 1991
Deck/Cargo
Issued 11 April 1991
Resolved
PROVIDE ABYC APPROVED PORTABLE FUEL GASOLINE CANS FOR SKIFFS OR PROVIDE DOCUMENTATION THAT EXISTING CANS MEET ABYC STANDARDS.
Condition: Unknown
Due 11 April 1991
Resolved 11 April 1991
Engineering
Issued 11 April 1991
Resolved
PROVIDE SUITABLE HOSE LENGTHS FOR HAND BILGE PUMP
Condition: Unknown
Due 11 April 1991
Resolved 11 April 1991
Electrical
Issued 11 April 1991
Resolved
PROVIDE METAL OR PLASTIC GUARDS AROUND LIGHTS IN ENGINE ROOM
Condition: Unknown
Due 11 April 1991
Resolved 11 April 1991
Navigation
Issued 28 April 1988
Resolved
INSTALL A MASTHEAD AND STERN LIGHT.
Condition: Unknown
Due 28 April 1988
Resolved 28 April 1988
Documentation
Issued 9 October 1986
Resolved
PROVIDE A FCC RADIOTELEPHONY CERTIFICATE ONBOARD.
Condition: Unknown
Due 9 October 1986
Resolved 9 October 1986
Documentation
Issued 9 October 1986
Resolved
PROVIDE A THIRD CLASS RADIO OPERATORS LICENSE ONBOARD.
Condition: Unknown
Due 9 October 1986
Resolved 9 October 1986
Lifesaving
Issued 9 October 1986
Resolved
PROVIDE TWO CHILDS TYPE 1 LIFE PRESERVERS.
Condition: Unknown
Due 9 October 1986
Resolved 9 October 1986