Records from 2001 to 2018. Most recent: operational control imposed, 24 April 2018.
Inspection history · 50
24 April 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6399115
25 March 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6378103
14 March 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6371527
11 March 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6369825
11 March 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6390605
23 February 2018
COE-Dockside · ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6356576
21 February 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6358396
30 January 2018
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6346507
20 November 2017
COE-Dockside
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6309988
13 September 2017
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6266051
18 August 2017
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6272629
18 May 2017
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6144807
19 April 2017
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6128513
9 April 2017
COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6112423
8 March 2017
COE-Offshore
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6101415
8 March 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6101436
7 July 2016
COE-Dockside
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5919670
31 May 2016
ISPS II Exam · Ballast Water Examination · COE-Dockside · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5884197
14 October 2014
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5004680
10 October 2014
COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5002795
17 March 2014
COE-Dockside
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4817871
5 July 2012
COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4367992
29 May 2012
Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4326945
6 July 2011
COE-Offshore
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4069731
2 July 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4065639
27 April 2009
COC-TVE Annual · Ballast Water Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3462325
3 February 2009
NPV Safety Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3412938
28 April 2008
COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3193963
10 March 2008
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3161633
11 May 2007
Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2927642
2 May 2007
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2920343
1 May 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2926277
22 April 2007
Random ISPS/MTSA/PSC
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2912684
23 February 2007
Random ISPS/MTSA/PSC
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2876706
31 July 2006
MARPOL Annex I Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2731171
6 June 2006
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2680851
31 May 2006
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2666116
15 May 2006
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2649424
28 April 2006
Ballast Water Examination · ISPS III Exam · MARPOL Annex V Examination · COC-TVE Renew · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2635009
11 July 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2423245
4 July 2005
MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2409035
28 June 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2406214
24 September 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2204615
8 August 2004
ISPS II Exam
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2159313
24 May 2004
Certificate of Compliance · ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2077927
2 September 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1894836
17 May 2003
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1796545
17 April 2002
Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1605766
14 June 2001
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 290987
18 April 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 289296
Operations/Management › Vessel Activity › Underway
Issued 17 October 2017
No resolution recorded
Vessel departed the Port of Mobile prior to meeting Captain of the Port Order #029-17 requirements
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 17 October 2017 — due date passed with no resolution recorded
Personnel › Manning/Qualifications › Person in Charge (PIC) of Transfer
Issued 27 April 2009
Resolved
[name withheld] was unable to display proper competence in calibrating the SALCWICO SW2020 Fixed Gas Sampling System. System was due for April calibration. When asked to conduct the test during the PSC [name withheld], Chief admitted to not knowing how to. Through ISM Company, ensure [name withheld] receives proper training and provide proof to USCG.
Action required: 705 - Other - as specified
Due 28 May 2009
Resolved 20 May 2009
Resolution: While onboard the [name withheld] was able to calibrate the SALCWICO SW2020 Fixed Gas Sampling System. Demonstrated knowledge of system.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 27 April 2009
Resolved
The calibration for the SALCWICO SW2020 Fixed Gas Sampling System will be due NLT 30 April 2009. Due to the [name withheld] inability to conduct test, ensure test in carried out by a competent person through the Certificate Issuing Authority and provide proof to the satisfaction of the US Coast Guard
Action required: 705 - Other - as specified
Due 12 May 2009
Resolved 20 May 2009
Resolution: Calibration of the SALCWICO SW2020 Fixed Gas Sampling System took place on 05may2009 as reported in the service report.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 27 April 2009
Resolved
Low Level alarm on Deck Water Seal was inop during systems check. Ensure alarm is 100% operational and provide proof to USCG through attending Class Surveyor. In the interim, ensure there is a constant vigil in the Cargo Control Room to monitor Deck Seal water level.
Action required: 705 - Other - as specified
Due 28 May 2009
Resolved 20 May 2009
Resolution: Received Class report attesting to repairs on the low level alarm on the deck water seal.
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 27 April 2009
Resolved
High level alarm on Scrubber was discovered inop during operational test. Prior to conducting cargo operations, ensure alarm in fully operational to the satisfaction of the attending Class Surveyor.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Resolution: Rcvd report from ABS attesting to satisfactory repair and full function check of the Scrubber alarms. Deficiency cleared.
Engineering › Steam System (main) › Piping
Issued 27 April 2009
Resolved
Steam line leaking in the ballast pump control panel on the cargo pump deck in the engine room, creating a puddle of water on deck. Vessel is to make permanent repairs to the satisfaction of the attending Class Surveyor.
Action required: 705 - Other - as specified
Due 28 May 2009
Resolved 20 May 2009
Resolution: While onboard verifyed the repairs to the main boiler feed pump return condensate steam line in the engine room were made.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 11 May 2007
Resolved
ODME Inoperable unknown possible electrical issue tech to inspect and repair to the satisfaction of class and prior to next US port. MARPOL 73/78 Annex I/15
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 May 2007
Resolution: Received tech report attesting to repairs being completed. Tech rep conducted simulator test and all was sat. Identified problem was a defective power supply.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 2 May 2007
Resolved
Port side, forward, vapor control flange was missing .5 inch diameter stud. Repairs must be made prior to next US port call.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 May 2007
Resolved 11 May 2007
Resolution: Inspected vapor control flange and confirmed replacement of .5 inch diameter stud.
Lifesaving › Lifeboat › Propulsion Engine
Issued 2 May 2007
Resolved
Port Lifeboat engine would not turn off with intended kill switch. Captain assured switch would be replaces ASP. Lifeboat engine can be secured by alternate kill switch.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 May 2007
Resolved 2 May 2007
Resolution: Alternate means to stop engine were provided.
Engineering › Steering Gear System › Ram Seal
Issued 28 April 2006
Resolved
The starboard side of steering gear unit has a hydraulic oil leak around the forward hydraulic ram.
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 28 April 2006
Resolution: Received class report stating that steering gear was repaired by replacing the V-packings Steering gear was tested in all modes and deemed satisfactory.
Engineering › Steam System (auxiliary) › Piping
Issued 28 April 2006
Resolved
The steam line going to condenser has excess steam leak. Make permanent and proper repair to line.
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 12 May 2006
Resolution: The pipe was identified as bunker tank drain return to atmospheric condenser. The crew removed the leaking pipe and replaced with new pipe. All was found in good working order, to the satisfaction of class.