MAURY USCG vessel records
← All vessels

FAIRBANKS PROVIDER

Built
2001
Last inspected
15 July 2025
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 15 July 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 21 calendar years (2001–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
2078 - Convention (Subpart B), Net Ton 6092 - Regulatory (Subpart C or D), Net Ton 6927 - Convention (Subpart B), Gross Ton 6092 - Regulatory (Subpart C or D), Gross Ton
Maury page id
psix-21425
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

GULF TITAN Towing Vessel · MISLE 30840 · 13 June 2013 · activity 4623180OCEAN TITAN Towing Vessel · MISLE 706414 · 17 May 2005 · activity 2408077

Inspection history · 32

15 July 2025 Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8192786
1 July 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8172686
13 January 2025 MARPOL Annex I Examination · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8060186
9 January 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7847009
5 June 2023 Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7829094
28 February 2023 MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7643497
24 January 2022 MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7385012
12 January 2021 Administrative Inspection · MARPOL Annex I Examination · COI Inspection · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7120742
23 September 2020 Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7063688
18 August 2020 Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7030041
6 January 2020 MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6883445
21 December 2018 MARPOL Annex I Examination · Annual Inspection · Internal Structural Exam · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6599812
8 January 2018 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6484512
28 December 2016 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6063264
22 January 2016 Internal Structural Exam · Drydock Exam · COI Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5802019
29 December 2014 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5045496
15 April 2014 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4838421
8 January 2014 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4774630
13 June 2013 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4623180
14 February 2012 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4244126
30 April 2010 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3910063
26 January 2009 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3400540
27 February 2008 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3154591
6 April 2007 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2903026
1 March 2006 Internal Structural Exam · MTSA Verification · COI Inspection · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2593982
17 May 2005 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2408077
27 April 2005 MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2344161
3 March 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2017224
20 January 2004 Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2001404
31 December 2003 Security Plan Review - VSP
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2006257
28 May 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1723455
26 February 2001 Hull Examination · Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1436517

Deficiency record · 13

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 January 2022 Resolved
Portable extinguishers expired in generator space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2022
Resolved 27 January 2022
Resolution: Replaced extinguishers.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 January 2022 Resolved
Remote fuel shut off line found disconnected from fuel shut off valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2022
Resolved 27 January 2022
Resolution: Reinstalled/tested manuel fuel shut off line.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 29 December 2014 Resolved
Make permanent repair to unused cable penetration between port aft rake and center aft rake at next drydock IAW 46 CFR 92.01-10.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 January 2016
Resolved 29 January 2016
Resolution: Vessel repairs conducted during January 2016 drydocking.
Construction/Loadline › Structures › Rake
Issued 8 January 2014 Resolved
Submit repairs proposal port fwd rake side shell and frames.
Action required: 705 - Other - as specified
Resolved 5 February 2014
Resolution: Side shell plating from frame 0 to frame 3 was partially cropped and renewed. ABS oversaw repairs and provided ABS Survey Report attesting to repairs.
Construction/Loadline › Hull › Longitudinal Frame
Issued 8 January 2014 Resolved
Submit repairs proposal for no. 4 port void, frame 26 torn at side longitudinal. Make repairs IAW approved proposal.
Action required: 705 - Other - as specified
Resolved 6 February 2014
Resolution: Inspector entered No. 4 Port Void and were unable to find any damage. CG-835 requirement cleared.
Construction/Loadline › Hull › Longitudinal Frame
Issued 8 January 2014 Resolved
Submit repairs proposal for no. 3 port void, aft of fwd bulkhead, 3 sidelong deflected and brackets tripped.
Action required: 705 - Other - as specified
Resolved 5 February 2014
Resolution: The affected frames were partly cropped and renewed. Affected brackets were cropped and renewed. ABS oversaw repairs and provided ABS Survey Report attesting to the repairs.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 26 January 2009 Resolved
In the #1 port void, at frame 4 crop and renew stiffener B and C
Action required: 705 - Other - as specified
Resolved 9 February 2009
Resolution: Stiffeners B and C were replaced.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 26 January 2009 Resolved
In the #1 port void, at frame 5 crop and renew #1 long between frame A/B/C.
Action required: 705 - Other - as specified
Resolved 9 February 2009
Resolution: Replaced #1 long between frame A/B/C.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 26 January 2009 Resolved
In the #1 port void, at frame 6 crop and renew #1 long between frame A/B/C and replace stiffener A and C.
Action required: 705 - Other - as specified
Resolved 9 February 2009
Resolution: Inserted #1 longitudinal between framed A/B/C and replaced stiffeners A and C.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 26 January 2009 Resolved
In the #1 port void, at frame 7 crop and renew #1 long between frame A/B/C and replace A/B/C stiffener.
Action required: 705 - Other - as specified
Resolved 9 February 2009
Resolution: Replaced frame A/B/C and replaced A/B/C stiffener.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 26 January 2009 Resolved
In the #2 port void, replace #1 and #2 bracket.
Action required: 705 - Other - as specified
Resolved 9 February 2009
Resolution: Replaced #1 and #2 bracket.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 26 January 2009 Resolved
Crop and renew the watertight bulkhead between the #1 and #2 port void at the #1/#2 bracket location.
Action required: 705 - Other - as specified
Resolved 9 February 2009
Resolution: Cropped and renewed the watertight bulkhead between the #1 and #2 port void at the #1/#2 bracket location.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 26 January 2009 Resolved
Crop and renew the watertight bulkhead between the #3 and #4 port void at the #3/#4 longitudinal location.
Action required: 705 - Other - as specified
Resolved 9 February 2009
Resolution: Cropped and renewed the watertight bulkhead between the #3 and #4 port void at the #3/#4 longitudinal location.

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.