Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
2078 - Convention (Subpart B), Net Ton
6092 - Regulatory (Subpart C or D), Net Ton
6927 - Convention (Subpart B), Gross Ton
6092 - Regulatory (Subpart C or D), Gross Ton
Maury page id
psix-21425
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 January 2022Resolved
Portable extinguishers expired in generator space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2022
Resolved 27 January 2022
Resolution: Replaced extinguishers.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 January 2022Resolved
Remote fuel shut off line found disconnected from fuel shut off valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2022
Resolved 27 January 2022
Resolution: Reinstalled/tested manuel fuel shut off line.
Make permanent repair to unused cable penetration between port aft rake and center aft rake at next drydock IAW 46 CFR 92.01-10.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 January 2016
Resolved 29 January 2016
Resolution: Vessel repairs conducted during January 2016 drydocking.
Construction/Loadline › Structures › Rake
Issued 8 January 2014Resolved
Submit repairs proposal port fwd rake side shell and frames.
Action required: 705 - Other - as specified
Resolved 5 February 2014
Resolution: Side shell plating from frame 0 to frame 3 was partially cropped and renewed. ABS oversaw repairs and provided ABS Survey Report attesting to repairs.
Construction/Loadline › Hull › Longitudinal Frame
Issued 8 January 2014Resolved
Submit repairs proposal for no. 4 port void, frame 26 torn at side longitudinal. Make repairs IAW approved proposal.
Action required: 705 - Other - as specified
Resolved 6 February 2014
Resolution: Inspector entered No. 4 Port Void and were unable to find any damage. CG-835 requirement cleared.
Construction/Loadline › Hull › Longitudinal Frame
Issued 8 January 2014Resolved
Submit repairs proposal for no. 3 port void, aft of fwd bulkhead, 3 sidelong deflected and brackets tripped.
Action required: 705 - Other - as specified
Resolved 5 February 2014
Resolution: The affected frames were partly cropped and renewed. Affected brackets were cropped and renewed. ABS oversaw repairs and provided ABS Survey Report attesting to the repairs.
In the #1 port void, at frame 6 crop and renew #1 long between frame A/B/C and replace stiffener A and C.
Action required: 705 - Other - as specified
Resolved 9 February 2009
Resolution: Inserted #1 longitudinal between framed A/B/C and replaced stiffeners A and C.
Crop and renew the watertight bulkhead between the #1 and #2 port void at the #1/#2 bracket location.
Action required: 705 - Other - as specified
Resolved 9 February 2009
Resolution: Cropped and renewed the watertight bulkhead between the #1 and #2 port void at the #1/#2 bracket location.
Crop and renew the watertight bulkhead between the #3 and #4 port void at the #3/#4 longitudinal location.
Action required: 705 - Other - as specified
Resolved 9 February 2009
Resolution: Cropped and renewed the watertight bulkhead between the #3 and #4 port void at the #3/#4 longitudinal location.