MAURY USCG vessel records
← All vessels

TONY LOPEZ ELEVATOR

Built
1982
Last inspected
24 May 2022
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 May 2022
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WAS6198
214274
Flag
UNITED STATES
Maury page id
psix-214274

Documentation record

Registered dimensions (L × B × D)65.0 ft × 24.0 ft × 4.5 ft
Registered tonnagegross 58 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELEVATING BOATS INC. · CAERNARVON, LA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Simplified, Net Ton
58 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 9 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each, 5 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 9

24 May 2022 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7457936
21 October 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7336857
6 November 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7090962
3 November 2020 Administrative Inspection · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7088732
24 September 2019 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6819781
8 May 2019 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6678958
1 April 2019 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6653519
10 September 2018 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6561393
17 November 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6043326

Deficiency record · 22

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2021 No resolution recorded
Diesel exhaust piping shall be in accordance with 46 CFR 182.15-20. Port and starboard engine found to have exhaust leaks and no longer meeting standard. Also found pillow stuffed in raceway leading into accommodation space.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 October 2021 No resolution recorded
At each inspection, watertight enclosures and structure shall remain watertight. During inspection identified temp repair adjacent to/underneath water heater. (Old “T” 46 CFR176.25-5(a)(2))
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 October 2021 No resolution recorded
Diesel engines shall be water jacketed and cooled by water from a pump which operates whenever the engine is operating. Keel cooler found to have a crack and be leaking, prohibiting proper cooling of starboard engine. (Old “T” 182.20-10(b)(1))
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 21 October 2021 No resolution recorded
Electrical equipment for vital systems are to be given special consideration in alignment with Subchapter J. In accordance with Old “J” 111.05-15(a)(2), electrical equipment should be so placed to minimize possibility of damage from dripping liquids. 12V VDC box for port and starboard engines were unable to close, and would no longer protect the wiring from dripping liquids. (Old “T” 46 CFR 183.01-10)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 October 2021 No resolution recorded
Suitable covers are to be installed in way of all exposed and hazardous places, to include machinery. Port side engine did not have guards covering shaft and power take off. (Old “T” 46 CFR 177.35-15)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2020 Resolved
Section of lagging missing on port MDE exhaust piping.
Action required: 10 - Deficiency Rectified
Resolved 6 November 2020
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 September 2019 Resolved
Ensure all logs are maintained in good order.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2019
Resolution: Captain has established daily logs.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 September 2019 Resolved
Provide proof of 3rd party certificate for portable fire ext.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2019
Resolution: Certs provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2019 Resolved
Replace all hydraulic hoses IAW Policy ltr 07-02 for liftboats for the 10 year leg inspection requirements.
Action required: 705 - Other - as specified
Resolved 25 September 2019
Resolution: All hoses were replaced and tested.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 September 2019 Resolved
Low hydraulic level for legs alarm inop.
Action required: 10 - Deficiency Rectified
Resolved 24 September 2019
Resolution: Tech replaced sensor and tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Revolution counter
Issued 24 September 2019 Resolved
Provide shaft tachometer or a shaft to engine rpm conversion table.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2019
Resolution: Shaft RPM reference table was displayed in the P/H.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 September 2019 Resolved
The tilt alarm on the bridge is inop.
Action required: 10 - Deficiency Rectified
Resolved 24 September 2019
Resolution: Replaced anunciator, and tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 24 September 2019 Resolved
The anemometer is not communicating with the digital read-out.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2019
Resolution: New anemometer was installed and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 September 2019 Resolved
Life jacket light on bridge is inop.
Action required: 10 - Deficiency Rectified
Resolved 24 September 2019
Resolution: Replaced battery in light, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2019 Resolved
Install a metal wire support in the port engine room where it is suppoting the electrical wire.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2019
Resolution: Installed metal support.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 24 September 2019 Resolved
The rescue tag line should be longer to maintain positive control while lifting with the crane.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2019
Resolution: Replaced the tag line to make it longer.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 September 2019 Resolved
Replace two fuel hoses on the deck generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2019
Resolution: The hoses were replaced and tested.
Electrical › Electric Generation Source (service) › Generator
Issued 17 November 2016 Resolved
prove proper operation of the ships electrical generator. while underway to perform drills, the vessels generator secured and the crew was unable to restore power.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2016
Resolution: satisfactorily tested ships generator. cause of engine failure was determined to be clogged fuel filters and blocked supply lines.
Construction/Loadline › Structures › Door
Issued 17 November 2016 Resolved
The STBD E/R hatch has a small hole wasted into the hatch. Clad weld repair the hole.
Condition: Invalid
Due 1 December 2016
Resolved 9 December 2016
Resolution: Clad welded the small hole.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 17 November 2016 Resolved
Both main engine keel coolers had soft patches on the channels. Soft patches need to be repaired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2016
Resolution: keel cooler soft patches removed and new metal inserted.
Engineering › Fuel Oil Service System › Hose
Issued 17 November 2016 Resolved
Provide flexible hoses that meet/exceed J1942. Both main engines have cloth hoses that do not have accompanying certificates.
Due 1 December 2016
Resolved 9 December 2016
Resolution: All unapproved hoses in the engine room were renewed with hoses meeting/exceeding J1942. All fittings were of approved type.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 17 November 2016 Resolved
Repair fuel leak on the port side of the engine room, underneath the ships generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2016
Resolution: fuel leak was a result of old hoses. hoses were changed and all diesel was satisfactorily cleaned.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.