TONY LOPEZ ELEVATOR
Offshore Supply Vessel · Offshore class · Built 1980s · USCG Heartland District (CGD-H) · Other hulls named TONY LOPEZ ELEVATOR
TONY LOPEZ ELEVATOR is a 1982 offshore supply vessel. The Coast Guard has recorded 40 inspections since 1991, most recently in May 2022, along with 44 deficiencies — 5 with no resolution recorded — and 1 operational control.
Records from 1991 to 2022. Most recent: inspection, 24 May 2022.
- Built
- 1982
- Last inspected
- 24 May 2022
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 44 recorded · 5 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
653560
WAS6198
214274
Flag
UNITED STATES
—
Maury page id
psix-214274
Inspections, by type
…with no type recorded3
Years with a record
26 calendar years (1991–2022)
The 40 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Registered dimensions (L × B × D)65.0 ft × 24.0 ft × 4.5 ft
Registered tonnagegross 58 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELEVATING BOATS INC. · CAERNARVON, LA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Simplified, Net Ton
58 - Simplified, Gross Ton
58 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 40
24 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7457936
21 October 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7336857
6 November 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7090962
3 November 2020
Administrative Inspection · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7088732
24 September 2019
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6819781
8 May 2019
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6678958
1 April 2019
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6653519
10 September 2018
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6561393
17 November 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6043326
6 November 2015
Administrative Inspection · COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5758540
20 October 2015
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5746601
6 October 2015
Deficiency Check · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5736556
5 August 2014
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4944078
9 May 2012
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4306540
11 August 2011
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4112578
12 November 2010
Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3889037
21 April 2009
Re-Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3457220
13 November 2008
Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3362871
22 September 2008
Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3330260
19 April 2007
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2910712
22 November 2005
Examination of Repairs · Periodic Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2539139
28 February 2005
Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2300424
19 September 2003
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1908551
18 February 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1745999
19 November 2001
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1391731
3 October 2000
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452723
6 December 1999
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1432222
14 October 1998
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415066
6 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 785293
14 November 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390641
19 December 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 674493
27 November 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421282
24 September 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 53982
28 November 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 882554
13 October 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214382
13 October 1995
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437018
11 September 1995
Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357313
27 September 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 842687
4 February 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1257235
15 August 1991
Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 932884
Deficiency record · 44
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2021
No resolution recorded
Diesel exhaust piping shall be in accordance with 46 CFR 182.15-20. Port and starboard engine found to have exhaust leaks and no longer meeting standard. Also found pillow stuffed in raceway leading into accommodation space.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 October 2021
No resolution recorded
At each inspection, watertight enclosures and structure shall remain watertight. During inspection identified temp repair adjacent to/underneath water heater. (Old “T” 46 CFR176.25-5(a)(2))
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 October 2021
No resolution recorded
Diesel engines shall be water jacketed and cooled by water from a pump which operates whenever the engine is operating. Keel cooler found to have a crack and be leaking, prohibiting proper cooling of starboard engine. (Old “T” 182.20-10(b)(1))
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 21 October 2021
No resolution recorded
Electrical equipment for vital systems are to be given special consideration in alignment with Subchapter J. In accordance with Old “J” 111.05-15(a)(2), electrical equipment should be so placed to minimize possibility of damage from dripping liquids. 12V VDC box for port and starboard engines were unable to close, and would no longer protect the wiring from dripping liquids. (Old “T” 46 CFR 183.01-10)
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 October 2021
No resolution recorded
Suitable covers are to be installed in way of all exposed and hazardous places, to include machinery. Port side engine did not have guards covering shaft and power take off. (Old “T” 46 CFR 177.35-15)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2020
Resolved
Section of lagging missing on port MDE exhaust piping.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 September 2019
Resolved
Ensure all logs are maintained in good order.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 September 2019
Resolved
Provide proof of 3rd party certificate for portable fire ext.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2019
Resolved
Replace all hydraulic hoses IAW Policy ltr 07-02 for liftboats for the 10 year leg inspection requirements.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 September 2019
Resolved
Low hydraulic level for legs alarm inop.
10 - Safety of Navigation › N/A - No Subsystem › Revolution counter
Issued 24 September 2019
Resolved
Provide shaft tachometer or a shaft to engine rpm conversion table.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 September 2019
Resolved
The tilt alarm on the bridge is inop.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 24 September 2019
Resolved
The anemometer is not communicating with the digital read-out.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 September 2019
Resolved
Life jacket light on bridge is inop.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2019
Resolved
Install a metal wire support in the port engine room where it is suppoting the electrical wire.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 24 September 2019
Resolved
The rescue tag line should be longer to maintain positive control while lifting with the crane.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 September 2019
Resolved
Replace two fuel hoses on the deck generator.
Electrical › Electric Generation Source (service) › Generator
Issued 17 November 2016
Resolved
prove proper operation of the ships electrical generator. while underway to perform drills, the vessels generator secured and the crew was unable to restore power.
Construction/Loadline › Structures › Door
Issued 17 November 2016
Resolved
The STBD E/R hatch has a small hole wasted into the hatch. Clad weld repair the hole.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 17 November 2016
Resolved
Both main engine keel coolers had soft patches on the channels. Soft patches need to be repaired.
Engineering › Fuel Oil Service System › Hose
Issued 17 November 2016
Resolved
Provide flexible hoses that meet/exceed J1942. Both main engines have cloth hoses that do not have accompanying certificates.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 17 November 2016
Resolved
Repair fuel leak on the port side of the engine room, underneath the ships generator.
Electrical › Lighting (emergency) › Lighting Feeder
Issued 6 November 2015
Resolved
Prove proper operation of emergency lighting system. 46 CFR 183.01-10
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 November 2015
Resolved
Conduct satisfactory drills with vessel's assigned crew.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 6 November 2015
Resolved
Prove proper operation of MSD. 33 CFR 159
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 5 August 2014
Resolved
Proper logs not maintained from SEP2013 to MAY 2014.
Lifesaving › Lifefloat › Float Free
Issued 9 May 2012
Resolved
Float was not float free.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 April 2009
Resolved
Properly mark each E-light on vsl.
Lifesaving › Lifefloat › Float-free Link
Issued 21 April 2009
Resolved
Renew weak link on lifefloat installation.
Fire Fighting › Remote Fuel Shutoff › General
Issued 21 April 2009
Resolved
Replace damaged handle tack welded to the fuel stuoff bar on stbd outboard fuel tank.
Communications › Radio Communications › EPIRB
Issued 21 April 2009
Resolved
Renew hydrostatic release on EPIRB installation.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 22 November 2005
Resolved
Provide required day shapes.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 22 November 2005
Resolved
Correct ezhaust leak, Port MDE.
Fire Fighting › Fire Main
Issued 19 September 2003
Resolved
Submersible fire pump discharge hose to fire main burst. LEGACY COMPONENT DESC: Condition
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 18 February 2003
Resolved
Replace all pubs.
Lifesaving
Issued 18 February 2003
Resolved
REplace EPIRB hydrostatic release. LEGACY COMPONENT DESC: EPIRB
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 18 February 2003
Resolved
Repair fuel leak on main engine.
Documentation
Issued 15 August 1991
Resolved
PROVIDE APPROVED PLANS AS REQUIRED BY ITEM 1 TO THE COGNIZANT OCMI.
Documentation
Issued 15 August 1991
Resolved
SUBMIT STABILITY CALCULATIONS TO THE U.S. COAST GUARD MARINE SAFETY CENTER_x001C_WASHINGTON, D.C. FOR REVIEW AND APPROVAL.
Documentation
Issued 15 August 1991
Resolved
SUBMIT THE FOLLOWING PLANS FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C.; INBOARD AND OUTBOARD PROFILES LEG STRUCRURAL SUPPORT AND LEG STRENGTH CRITERIA, HYDRAULIC JACKING SYSTEM DETAILS INCLUDING ALARMS AND CONTROLS.
Electrical
Issued 15 August 1991
Resolved
PROVE PROPER OPERATION OF SHIPS SERVICE GENERATOR OVERSPEED TRIP, LOW LUBE OIL TRIP AND HIGH JACKET WATER TEMPERATURE ALARM.
Navigation
Issued 15 August 1991
Resolved
CALIBRATE MAGNETIC COMPASS AND SUBMIT DEVIATION TABLE TO [name withheld].
Engineering
Issued 15 August 1991
Resolved
OPEN AIR RECEIVER FOR INTERNAL INSPECTION, INSTALL A RELIEF VALVE AND PROVESAME TO RELIEVE AT 200 PSI OR BELOW. INSTALL A GUARD OVER BELT AND PULLEYS.
Documentation
Issued 15 August 1991
Resolved
SUBMIT AN OPERATING MANUAL FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C. VESSEL IS PERMITTED TO OPERATE ON ITS EXISTING MANUAL UNTIL THE U.S. COAST GUARD APPROVED MANUAL IS RECEIVED.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.