MAURY USCG vessel records Sign in
← All vessels

TONY LOPEZ ELEVATOR

TONY LOPEZ ELEVATOR is a 1982 offshore supply vessel. The Coast Guard has recorded 40 inspections since 1991, most recently in May 2022, along with 44 deficiencies — 5 with no resolution recorded — and 1 operational control.

Records from 1991 to 2022. Most recent: inspection, 24 May 2022.

Built
1982
Last inspected
24 May 2022
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAS6198
214274
Flag
UNITED STATES
—
Maury page id
psix-214274

Inspections, by type

…with no type recorded3
Years with a record 26 calendar years (1991–2022)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)65.0 ft × 24.0 ft × 4.5 ft
Registered tonnagegross 58 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELEVATING BOATS INC. · CAERNARVON, LA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Simplified, Net Ton
58 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 40

24 May 2022 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7457936
21 October 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7336857
6 November 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7090962
3 November 2020 Administrative Inspection · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7088732
24 September 2019 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6819781
8 May 2019 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6678958
1 April 2019 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6653519
10 September 2018 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6561393
17 November 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6043326
6 November 2015 Administrative Inspection · COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5758540
20 October 2015 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5746601
6 October 2015 Deficiency Check · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5736556
5 August 2014 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4944078
9 May 2012 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4306540
11 August 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4112578
12 November 2010 Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3889037
21 April 2009 Re-Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3457220
13 November 2008 Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3362871
22 September 2008 Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3330260
19 April 2007 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2910712
22 November 2005 Examination of Repairs · Periodic Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2539139
28 February 2005 Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2300424
19 September 2003 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1908551
18 February 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1745999
19 November 2001 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1391731
3 October 2000 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452723
6 December 1999 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1432222
14 October 1998 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415066
6 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 785293
14 November 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390641
19 December 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 674493
27 November 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421282
24 September 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 53982
28 November 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 882554
13 October 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214382
13 October 1995 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437018
11 September 1995 Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357313
27 September 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 842687
4 February 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1257235
15 August 1991 Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 932884

Deficiency record · 44

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2021 No resolution recorded
Diesel exhaust piping shall be in accordance with 46 CFR 182.15-20. Port and starboard engine found to have exhaust leaks and no longer meeting standard. Also found pillow stuffed in raceway leading into accommodation space.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 October 2021 No resolution recorded
At each inspection, watertight enclosures and structure shall remain watertight. During inspection identified temp repair adjacent to/underneath water heater. (Old “T” 46 CFR176.25-5(a)(2))
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 October 2021 No resolution recorded
Diesel engines shall be water jacketed and cooled by water from a pump which operates whenever the engine is operating. Keel cooler found to have a crack and be leaking, prohibiting proper cooling of starboard engine. (Old “T” 182.20-10(b)(1))
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 21 October 2021 No resolution recorded
Electrical equipment for vital systems are to be given special consideration in alignment with Subchapter J. In accordance with Old “J” 111.05-15(a)(2), electrical equipment should be so placed to minimize possibility of damage from dripping liquids. 12V VDC box for port and starboard engines were unable to close, and would no longer protect the wiring from dripping liquids. (Old “T” 46 CFR 183.01-10)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 October 2021 No resolution recorded
Suitable covers are to be installed in way of all exposed and hazardous places, to include machinery. Port side engine did not have guards covering shaft and power take off. (Old “T” 46 CFR 177.35-15)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2020 Resolved
Section of lagging missing on port MDE exhaust piping.
Action required: 10 - Deficiency Rectified
Resolved 6 November 2020
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 September 2019 Resolved
Ensure all logs are maintained in good order.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2019
Resolution: Captain has established daily logs.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 September 2019 Resolved
Provide proof of 3rd party certificate for portable fire ext.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2019
Resolution: Certs provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2019 Resolved
Replace all hydraulic hoses IAW Policy ltr 07-02 for liftboats for the 10 year leg inspection requirements.
Action required: 705 - Other - as specified
Resolved 25 September 2019
Resolution: All hoses were replaced and tested.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 September 2019 Resolved
Low hydraulic level for legs alarm inop.
Action required: 10 - Deficiency Rectified
Resolved 24 September 2019
Resolution: Tech replaced sensor and tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Revolution counter
Issued 24 September 2019 Resolved
Provide shaft tachometer or a shaft to engine rpm conversion table.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2019
Resolution: Shaft RPM reference table was displayed in the P/H.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 September 2019 Resolved
The tilt alarm on the bridge is inop.
Action required: 10 - Deficiency Rectified
Resolved 24 September 2019
Resolution: Replaced anunciator, and tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 24 September 2019 Resolved
The anemometer is not communicating with the digital read-out.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2019
Resolution: New anemometer was installed and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 September 2019 Resolved
Life jacket light on bridge is inop.
Action required: 10 - Deficiency Rectified
Resolved 24 September 2019
Resolution: Replaced battery in light, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2019 Resolved
Install a metal wire support in the port engine room where it is suppoting the electrical wire.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2019
Resolution: Installed metal support.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 24 September 2019 Resolved
The rescue tag line should be longer to maintain positive control while lifting with the crane.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2019
Resolution: Replaced the tag line to make it longer.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 September 2019 Resolved
Replace two fuel hoses on the deck generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2019
Resolution: The hoses were replaced and tested.
Electrical › Electric Generation Source (service) › Generator
Issued 17 November 2016 Resolved
prove proper operation of the ships electrical generator. while underway to perform drills, the vessels generator secured and the crew was unable to restore power.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2016
Resolution: satisfactorily tested ships generator. cause of engine failure was determined to be clogged fuel filters and blocked supply lines.
Construction/Loadline › Structures › Door
Issued 17 November 2016 Resolved
The STBD E/R hatch has a small hole wasted into the hatch. Clad weld repair the hole.
Condition: Invalid
Due 1 December 2016
Resolved 9 December 2016
Resolution: Clad welded the small hole.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 17 November 2016 Resolved
Both main engine keel coolers had soft patches on the channels. Soft patches need to be repaired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2016
Resolution: keel cooler soft patches removed and new metal inserted.
Engineering › Fuel Oil Service System › Hose
Issued 17 November 2016 Resolved
Provide flexible hoses that meet/exceed J1942. Both main engines have cloth hoses that do not have accompanying certificates.
Due 1 December 2016
Resolved 9 December 2016
Resolution: All unapproved hoses in the engine room were renewed with hoses meeting/exceeding J1942. All fittings were of approved type.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 17 November 2016 Resolved
Repair fuel leak on the port side of the engine room, underneath the ships generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2016
Resolution: fuel leak was a result of old hoses. hoses were changed and all diesel was satisfactorily cleaned.
Electrical › Lighting (emergency) › Lighting Feeder
Issued 6 November 2015 Resolved
Prove proper operation of emergency lighting system. 46 CFR 183.01-10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2015
Resolution: Witnessed satisfactory test of emergency lighting system
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 November 2015 Resolved
Conduct satisfactory drills with vessel's assigned crew.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2015
Resolution: Witnessed satisfactory test of fire, MOB, and abandon ship drills
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 6 November 2015 Resolved
Prove proper operation of MSD. 33 CFR 159
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2015
Resolution: Witnessed proper operation of MSD
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 5 August 2014 Resolved
Proper logs not maintained from SEP2013 to MAY 2014.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2015
Resolved 20 October 2015
Resolution: Corrected
Lifesaving › Lifefloat › Float Free
Issued 9 May 2012 Resolved
Float was not float free.
Action required: 705 - Other - as specified
Resolved 10 May 2012
Resolution: Vessel crew made lifefloat, float free.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 April 2009 Resolved
Properly mark each E-light on vsl.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2009
Resolution: Stenciled E''s on fixture.
Lifesaving › Lifefloat › Float-free Link
Issued 21 April 2009 Resolved
Renew weak link on lifefloat installation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2009
Fire Fighting › Remote Fuel Shutoff › General
Issued 21 April 2009 Resolved
Replace damaged handle tack welded to the fuel stuoff bar on stbd outboard fuel tank.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2009
Communications › Radio Communications › EPIRB
Issued 21 April 2009 Resolved
Renew hydrostatic release on EPIRB installation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2009
Resolution: Renewed hydo release.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 22 November 2005 Resolved
Provide required day shapes.
Action required: 705 - Other - as specified
Due 22 December 2005
Resolved 22 November 2005
Resolution: Dayshapes on board.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 22 November 2005 Resolved
Correct ezhaust leak, Port MDE.
Action required: 705 - Other - as specified
Due 22 December 2005
Resolved 22 November 2005
Resolution: Exhaust leak corrected.
Fire Fighting › Fire Main
Issued 19 September 2003 Resolved
Submersible fire pump discharge hose to fire main burst. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 September 2003
Resolution: Hose was replaced during inspection.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 18 February 2003 Resolved
Replace all pubs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2003
Resolution: Pubs provided.
Lifesaving
Issued 18 February 2003 Resolved
REplace EPIRB hydrostatic release. LEGACY COMPONENT DESC: EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2003
Resolution: Hydrostatic release replaced.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 18 February 2003 Resolved
Repair fuel leak on main engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2003
Resolution: Replaced leaking fitting.
Documentation
Issued 15 August 1991 Resolved
PROVIDE APPROVED PLANS AS REQUIRED BY ITEM 1 TO THE COGNIZANT OCMI.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Documentation
Issued 15 August 1991 Resolved
SUBMIT STABILITY CALCULATIONS TO THE U.S. COAST GUARD MARINE SAFETY CENTER_x001C_WASHINGTON, D.C. FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Documentation
Issued 15 August 1991 Resolved
SUBMIT THE FOLLOWING PLANS FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C.; INBOARD AND OUTBOARD PROFILES LEG STRUCRURAL SUPPORT AND LEG STRENGTH CRITERIA, HYDRAULIC JACKING SYSTEM DETAILS INCLUDING ALARMS AND CONTROLS.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Electrical
Issued 15 August 1991 Resolved
PROVE PROPER OPERATION OF SHIPS SERVICE GENERATOR OVERSPEED TRIP, LOW LUBE OIL TRIP AND HIGH JACKET WATER TEMPERATURE ALARM.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Navigation
Issued 15 August 1991 Resolved
CALIBRATE MAGNETIC COMPASS AND SUBMIT DEVIATION TABLE TO [name withheld].
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Engineering
Issued 15 August 1991 Resolved
OPEN AIR RECEIVER FOR INTERNAL INSPECTION, INSTALL A RELIEF VALVE AND PROVESAME TO RELIEVE AT 200 PSI OR BELOW. INSTALL A GUARD OVER BELT AND PULLEYS.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Documentation
Issued 15 August 1991 Resolved
SUBMIT AN OPERATING MANUAL FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C. VESSEL IS PERMITTED TO OPERATE ON ITS EXISTING MANUAL UNTIL THE U.S. COAST GUARD APPROVED MANUAL IS RECEIVED.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.