MAURY USCG vessel records
← All vessels

CHARLIE H

CHARLIE H is a 1983 industrial vessel. The Coast Guard has recorded 11 inspections since 2016, most recently in October 2025, along with 34 deficiencies and 1 casualty investigation in 2007.

Records from 2007 to 2025. Most recent: inspection, 28 October 2025.

Built
1983
Last inspected
28 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 October 2025
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI5937
214386
Flag
UNITED STATES
Maury page id
psix-214386

Documentation record

Registered dimensions (L × B × D)52.0 ft × 22.0 ft × 7.6 ft
Registered tonnagegross 60 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARINE BUILDERS INC · CLARKSVILLE, IN, UNITED STATES · built 1983
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPITTSBURGH, PA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 January 2026 · expires 31 January 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it60 - Simplified, Gross Ton
48 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

28 October 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8239631
6 November 2024 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8024223
12 August 2024 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7979783
12 September 2023 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7747681
30 September 2022 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7569415
9 September 2022 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7528059
15 November 2021 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7352663
9 September 2021 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7308736
13 November 2020 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7082521
29 October 2019 Administrative Inspection · Initial Certification · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6844449
22 March 2016 Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5838340

Deficiency record · 34

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 28 October 2025 Resolved
Lifejackets must have the following attachments and fittings: each lifejacket must have a lifejacket light. Lights expired in March of 2025. Replace each lifejacket light with an operational light approved under series 161.012 or 161.112 that is not expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2025
Resolved 4 December 2025
Resolution: Recieved receipt proof of new marker lights
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 November 2024 Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Distribution panel located in pilot house failed to have breakers labeled with the loads they serve. Access to this panel was also obstructed by equipment and not readily accessible.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2024
Resolved 11 November 2024
Resolution: Panel is now labeled and all obstructions blocking access to the panel have been removed.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 September 2023 Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Required Test and Frequency: * Emergency lighting - Every 3 months * Alarm Set Points - Twice in 5 years * Essential systems - Every 3 months The following items were found to be not checked: * Emergency lighting * Alarm Set Points * Essential system (Emergency fuel shut offs, Bilge alarm) Begin conducting test of the above in accordance with frequency requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2023
Resolved 19 September 2023
Resolution: Added testing to SMS
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 12 September 2023 Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. Exhaust pipe on 02 deck by ladder not guarded. Install guard as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2023
Resolved 19 September 2023
Resolution: Added expanded metal around exhaust pipe
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 September 2023 Resolved
The following systems must be equipped with gauges at the machinery location: (1) Main engine lubricating oil pressure and main engine RPM. Engine RPM not working on HMI display in engine room. Repair RPM indicators as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2023
Resolved 19 September 2023
Resolution: Repaired RPM indicators
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 September 2023 Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Port engine started leaking oil. Repair oil leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2023
Resolved 19 September 2023
Resolution: Repaired oil leak
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 September 2023 Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. Flammable products found in galley. Store these product in flammable liquids locker or remove from vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2023
Resolved 19 September 2023
Resolution: Flammable materials removed from vessel
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 September 2023 Resolved
In addition to the requirements in paragraph (a) of this section, all fire-suppression and detection equipment and systems on board a towing vessel must be maintained in accordance with the attached nameplate, manufacturer's approved design manual, or as otherwise provided in any TSMS applicable to the vessel. Smoke detector in galley inoperable. Repair or replace with new.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2023
Resolved 19 September 2023
Resolution: Smoke detectors replaced with new
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 September 2023 Resolved
Each lifebuoy on a towing vessel must:(1) Be approved under approval series 160.050; (Have a grab line - The grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds.) Stern lifebuoy grab line wasted. Replace grab line with new.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2023
Resolved 19 September 2023
Resolution: Replaced with new
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 September 2023 Resolved
Lifebuoys must have the following attachments and fittings: (1) At least one lifebuoy must have a lifeline, secured around the body of the lifebuoy. If more than one lifebuoy is carried, at least one must not have a lifeline attached. Each lifeline on a lifebuoy must: (v) Have a breaking strength of at least 5 kilonewtons (1,124 pounds); Lifeline on stern lifebuoy wasted. Remove extra wasted lifeline from vessel or replace with new.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2023
Resolved 19 September 2023
Resolution: Replaced with new
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 September 2022 Resolved
Vessels with square bow. For vessels having a square bow, the name of the vessel must be marked on some clearly visible exterior part of the bow in a manner to avoid obliteration. Name of vessel not marked on bow. Provide vessel name on forward facing part of pilot house.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 30 September 2022
Resolution: Name applied to forward superstructure
08 - Alarms › N/A - No Subsystem › General alarm
Issued 9 September 2022 Resolved
Each towing vessel must be fitted with a general alarm. One of two general alarm lights in engine room inoperative. Repair light or remove from service.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 30 September 2022
Resolution: Light repaired
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 September 2022 Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. No means provided to secure ventilation in case of fire. Provide means to secure ventilation as required.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 30 September 2022
Resolution: Dampener installed
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 September 2022 Resolved
Each remote fuel shutoff valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. Labels for fuel shutoffs worn away. Relabel as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 30 September 2022
Resolution: Labels installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 September 2022 Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR - KEEP CLOSED” or “WATERTIGHT HATCH - KEEP CLOSED”. Watertight hatches missing required labels. Label as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 30 September 2022
Resolution: Labels installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 September 2022 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Breaker panel in engine room vestibule has a gap between cover plate and breakers. Close opening to prevent shock hazards.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 30 September 2022
Resolution: Breaker cover realigned to properly cover breakers
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 September 2022 Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Oil soaked absorbent rags found in engine room bilges. Remove rags.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 30 September 2022
Resolution: oil removed from bilge
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 September 2022 Resolved
Flammable and combustible products must not be stored in machinery spaces, unless they are stored in a suitable container that meets the requirements of § 142.225 of this subchapter. Hydraulic fluid and engine oil stored in plastic containers in engine room bilge. Remove all flammable materials from engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 30 September 2022
Resolution: Flammable materials removed from engine room
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 9 September 2022 Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. No rails installed at the bow on main deck or Texas deck. Install rails as required.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2022
Resolved 30 September 2022
Resolution: Rails installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 November 2021 Resolved
Stowage positions for lifejackets stowed in a berthing space or stateroom and all lifejacket containers must be marked in block capital letters and numbers with the minimum quantity, identity, and, if sizes other than adult or universal sizes are used on the vessel, the size of the lifejackets stowed inside the container. Lifejacket container on bridge missing number of jackets stored. CORRECTED ON THE SPOT.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 1 November 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 November 2021 Resolved
Each remote fuel shutoff valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. Remove fuel valve missing operation instructions. CORRECTED ON THE SPOT
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 1 November 2021
Resolution: Labeled valves with operating instructions
08 - Alarms › N/A - No Subsystem › General alarm
Issued 1 November 2021 Resolved
Each towing vessel must be fitted with a general alarm that has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light that is identified with a sign that reads: “Attention General Alarm - When Alarm Sounds or Flashes Go to Your Station”. General alarm light in forward engine room inoperable. Repair as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 November 2021
Resolution: Bulb replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 November 2021 Resolved
If twist-on types of connectors are used, the connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. Twist-on type of connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. Wire connection found in engine room with twist type connectors and no enclosure. Remove twist type connectors and permanently crimp wires as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 November 2021
Resolution: wires permanently spliced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 November 2021 Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. Generator batteries utilize welding cables as conductors. Replace cables with approved marine grade cables.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 November 2021
Resolution: Battery cables replaced with marine grade cables
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 1 November 2021 Resolved
Each watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT HATCH - KEEP CLOSED”. Watertight hatches for fuel tanks and void not labeled. Label as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 November 2021
Resolution: Labeled as required
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 1 November 2021 Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. Railing missing on stern and aft of tow knees. Install railing as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 November 2021
Resolution: Railing installed along aft raised deck and aft of tow knees
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 December 2019 Resolved
Fuel shutoff valves located at machinery. Fuel shutoff valves must be located outside of the fuel source.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 21 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 December 2019 Resolved
No means to illuminate crew working or living areas in the event of a power failure. Provide emergency lighting or phosphorescent strips to illuminate egress routes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 21 December 2019
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 December 2019 Resolved
Fire axe not readily accessible. Provide proper bracket on exterior of vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 21 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 December 2019 Resolved
Electrical distribution panels not properly marked with respective voltage and current.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2019
Resolved 21 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 December 2019 Resolved
Vessel shall have a documented fuel system maintenance plan to include items/systems, filter change interval and on board inventory.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 21 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 December 2019 Resolved
Dead end wires discovered on starboard engine inbourd side and port engine forward.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 21 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 December 2019 Resolved
Vessel shall have a record of towing gear to include type, size, and service of each towline, face wire, and spring line that shows dates of inspections and signature of person conducting inspections.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 21 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 December 2019 Resolved
Flammable storage cabinet shall be properly secured to vessel to prevent tipping or movement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2020
Resolved 21 December 2019

Casualty record · 1

23 May 2007Routine · role: Involved in a Marine Casualty · activity 2946121
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.