Records from 2001 to 2002. Most recent: inspection, 5 March 2002.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Fire Fighting
Issued 19 March 2001
Resolved
SJ171. PROVE PROPER OPERATION OF FIRE SCREEN DOOR, STARBOARD SIDE, FORWARD, MAIN DINING ROOM.
Condition: Unknown
Due 20 March 2001
Resolved 19 February 2002
Resolution: Cleared during COC/CVE in SJPMS.
Lifesaving
Issued 19 March 2001
Resolved
SJ168. REPAIR/REPLACE PUBLIC ADDRESS SYSTEM SPEAKER AT WTD #9 FRAME 70, SOUND UNINTELLIGIBLE.
Condition: Unknown
Due 20 March 2001
Resolved 19 February 2002
Resolution: Cleared during COC/CVE in SJPMS.
Lifesaving
Issued 19 March 2001
Resolved
SJ169. INCREASE PUBLIC ADDRESS SYSTEM SPEAKER VOLUME IN CORRIDOR IWO WTD #6. LOW VOLUME.
Condition: Unknown
Due 20 March 2001
Resolved 19 February 2002
Resolution: Cleared during COC/CVE in SJPMS.
Fire Fighting
Issued 19 March 2001
Resolved
REPAIR/RENEW PRESSURE RELIEF VALE FOR THE FIRE SCREEN DOOR ACCUMULATOR LOCATED IN THE EMERGENCY GENERATOR SPACE. INSTALL PRESSURE RELIEVE VALE INACCOREDANCE WITH MANUFACTURE DRAWINGS.
Condition: Unknown
Due 20 March 2001
Resolved 23 April 2001
Engineering
Issued 19 March 2001
Resolved
SJ102. PROVE PROPER OPERATION OF THE REMOTE FUEL OIL TANK-SOUNDING PANEL. EXTENDED FOR THREE MONTHS BY CLASS.
Condition: Unknown
Due 20 June 2001
Resolved 19 February 2002
Resolution: Cleared during COC/CVE in SJPMS.
Lifesaving
Issued 19 March 2001
Resolved
SJ113. PROVIDE PROPER PLACARDS (HIGH & LOW) FOR ALL EMERGENCY EQUIPMENT. LOW PLACARDS DO NOT SHOW LOCATION OF EQUIPMENT.
Condition: Unknown
Due 20 March 2001
Resolved 19 February 2002
Resolution: Cleared during COC/CVE in SJPMS.
Fire Fighting
Issued 19 March 2001
Resolved
SJ155. ADD FOG SPRINKLER IN HOTEL STORE CAGE LOCATED IN THE STEERING GEAR ROOM. NEED TO ADD ONE FOG SPRINKLER PER AISLE. A TOTAL OF 2 ADDITIONAL SPRINKLERS NEEDED.
Condition: Unknown
Due 20 April 2001
Resolved 19 February 2002
Resolution: Cleared during COC/CVE in SJPMS.
Fire Fighting
Issued 19 March 2001
Resolved
SJ156. ADD A FOG SPRINKLER IN LIQUOR STORE CAGE LOCATED IN THE STEERING GEAR ROOM. PLACE SPRINKLER IN MIDDLE OF ROOM ON OVERHEAD.
Condition: Unknown
Due 20 March 2001
Resolved 19 February 2002
Resolution: Cleared during COC/CVE in SJPMS.
Documentation
Issued 19 March 2001
Resolved
SJ173. MAIN SWITCHBOARD ROOM HAS AN ADDITIONAL FIRE EXTINGUISHER WHEN COMPARING SPACE TO FIRE CONTROL PLAN. MAKE "PEN & INK" CHANGE TO FCP TI INCLUDE ADDITIONAL FIRE EXTINGUISHER. IN ADDITION, PROPERLY STOW EXTINGUISHER.
Condition: Unknown
Due 20 March 2001
Resolved 19 February 2002
Resolution: Cleared during COC/CVE in SJPMS.
Lifesaving
Issued 19 March 2001
Resolved
SJ174. PROVIDE PROPER SIGN FOR SECTION VALVES LOCATED AT FRAME 74. CURRENT SIGN IS DESIGNATED WITH THE LETTER "D". SIGN SHOULD BE DESIGNATED BY THE LETTER "S".
Condition: Unknown
Due 20 March 2001
Resolved 19 February 2002
Resolution: Cleared during COC/CVE in SJPMS.
Lifesaving
Issued 19 March 2001
Resolved
SJ175. PROVIDE PROPER SIGNAGE FOR AUTO FIRE ALARM IN SHAFT ALLEY. (AS PERFIRE CONTROL PLAN)
Condition: Unknown
Due 20 March 2001
Resolved 19 February 2002
Resolution: Cleared during COC/CVE in SJPMS.
Engineering
Issued 19 March 2001
Resolved
PROVIDE PLANS/PROPOSAL FOR GASOLINE TANK PRIOR TO ICVE. PRESENT SYSTEM USES A TANK MADE OF PROHIBITED MATERIAL (STAINLESS STEEL). STOWAGE LOCATION NEAR AIR CONDITIONING AND ENGINE ROOM VENTILATION INTAKES. EMERGENCY DRAIN HOSE MADE FOR WATER SERVICE.
Condition: Unknown
Due 20 March 2001
Resolved 23 April 2001
System not recorded
Issued 17 January 2001
Resolved
COMPLETE ALL WORKLIST ITEMS AS ISSUED AT ICVE.
Condition: Unknown
Due 31 May 2001
Resolved 19 February 2002
Resolution: Cleared during COC/ CVE in SJPMS.