Records from 2016 to 2025. Most recent: inspection, 1 April 2025.
Inspection history · 14
1 April 2025
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8103663
11 March 2024
Hull Examination · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7868621
12 January 2023
Examination of Repairs · Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7616270
26 May 2022
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7451761
19 April 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7429602
10 August 2021
In-Service Inspection · Deadweight Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7341282
24 February 2021
DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7140061
20 April 2020
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6941410
14 April 2020
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6937495
25 April 2019
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6669396
24 April 2018
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6397665
16 April 2018
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6391013
13 April 2017
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6119540
11 April 2016
DAPI Audit · COI Inspection · Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5840431
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 12 January 2023
Resolved
Except as provided in paragraph (b) of this section, the weather deck on a flush deck vessel must be watertight and have no obstruction to overboard drainage.
The aft drainage freeing ports were found blocked by bundled electrical conductors and debris.
Clear the freeing ports to permit drainage aft. Rectify prior to issuance of the COI, Code 705.
46 CFR 178.410
Action required: 705 - Other - as specified
Due 12 January 2023
Resolved 7 February 2023
Resolution: MI attended the vessel and verified all freeing ports are cleared and the electrical conductors are routed above the drainage area.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 12 January 2023
Resolved
Paragraphs (c) through (g) of this section apply to each vessel that does not demonstrate compliance in accordance with § 178.310(c) of this chapter. Each vessel must have permanent loading marks placed on each side of the vessel forward and aft to indicate the maximum allowable trim and amidships to indicate the maximum allowable draft.
A loading mark required by paragraph (c)(2) of this section must be a horizontal line of at least 205 millimeters (8 inches) in length and 25 millimeters (1 inch) in height, with its upper edge passing through the point of maximum draft. The loading mark must be painted in a contrasting color to the side shell paint. The loading mark was not found permanently installed on each side of the vessel as per the valid stability letter which is based on a deadweight survey.
The deficiency will be rectified upon receiving a new stability letter, Code 705.
46 CFR 185.602
Action required: 705 - Other - as specified
Due 12 January 2023
Resolved 17 February 2023
Resolution: MSC issued a new stability letter. The operator marked the new loading marks on the hull in accordance with the calculations provided on the stability letter. MI verified the loading marks match the dimensions listed on the new stability letter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 January 2023
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station.
The new outboard engines do not have a lube oil gauge or jacket water temp gauge at the operating station.
Provide gauges as per regulations or request special consideration for an equivalent level of safety provided by the manufacturer alarm and safe mode shut down.
46 CFR 182.410(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2023
Resolved 13 January 2023
Resolution: The OCMI approved special consideration for the alternative arrangements for lube oil pressure alarms provided by the manufacturer for the engine.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 January 2023
Resolved
An emergency switch must be provided in the normally ungrounded main supply conductor from a battery. The switch must be accessible and located as close to the battery as practicable. Disconnect means must be provided on the supply side of and adjacent to all fuses for the purpose of de-energizing the fuses for inspection and maintenance purposes.
The operator removed the previously installed battery switch. A battery switch shall be installed on the supply side of the primary overcurrent protection.
Rectify prior to issuance of the COI, Code 705.
46 CFR 183.380(I)
Action required: 705 - Other - as specified
Due 12 January 2023
Resolved 19 January 2023
Resolution: The operator installed a new battery switch that is rated for the vessel's DC electrical system.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 January 2023
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant.
A blade 30 amp fuse was found installed at the positive battery terminal as the primary branch protection. The batteries are wired in parallel and are labeled for 800 CCA each. The blade fuse is not UL listed for marine use and the AIC rating is not high enough to interrupt the 1600 CCA in the event of a dead short to ground fault condition.
Rectify prior to the issuance of the COI, Code 705.
46 CFR 183.380(l)
Action required: 705 - Other - as specified
Due 12 January 2023
Resolved 19 January 2023
Resolution: All bladed fuses were removed and replaced with UL listed cartridge fuses IAW the conductor's current carrying capacity and 10 percent voltage drop.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 January 2023
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant.
Replace blade fuses in the 12V distribution under the console with UL listed cartridge type fuses.
Rectify prior to the issuance of the COI, Code 705.
46 CFR 183.380(l)
Action required: 705 - Other - as specified
Due 12 January 2023
Resolved 19 January 2023
Resolution: The blade fuses under the console were replaced by UL listed cartridge fuses of the same amperage.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 January 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew.
The marine inspector witnessed the cross deck in between the operator's console and port side passenger seating distort when dynamic forces were applied to the vessel underway in seas less than 2 feet. The main deck presents a hazard to passengers and the vessel's structure.
Provide a repair proposal and make satisfactory repairs to the vessel with a marine inspector in attendance. Rectify the deficiency no later than March 12, 2023.
46 CFR 177.100
Action required: 705 - Other - as specified
Due 12 March 2023
Resolved 7 February 2023
Resolution: The operator cropped the cross deck and discovered wood decay in the main deck. All wet wood was removed and replaced with Coosa Board. The new Coosa Board installation measures approximately 8' x 10' and is covered by new FRP.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 2 November 2021
Resolved
Alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without approval.
A new stability test must be conducted to the satisfaction of MSC and Sector St. [name withheld] due the weight change from the repower. Stability test procedures shall be submitted to MSC two weeks prior to the test.
Passenger count reduced to 25 until stability test is approved.
46 CFR 176.700(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2021
Resolved 31 May 2022
Resolution: Received letter from MSC documenting the repower and confirming that the current stability letter remains valid.
Construction/Loadline › Hull › Side Shell
Issued 19 April 2016
Resolved
Make permanent repairs to all identified areas on hull found during hull inspection. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 21 April 2016
Resolution: Prior to credit dry dock
Construction/Loadline › Hull › Side Shell
Issued 19 April 2016
Resolved
Remove rub rail on front and stbd side to blue chalk line and make repairs to deck to hull joint and areas under bow overhang. Remove old fiberglass and inspect wood for decay and replace if necessary.
Action required: 705 - Other - as specified
Resolved 21 April 2016
Resolution: Prior to credit Dry dock
Communications › Alarms/Indicators › High Water Alarm
Issued 11 April 2016
Resolved
Starboard hull high water alarm when tested was inoperative. Make repairs or replace and show proper operation. 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2016
Resolution: Corrected on the spot.