Records from 1985 to 2001. Most recent: inspection, 18 August 2001.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 46
18 August 2001
Administrative
Administrative · Activities Europe · Activity 1362443
27 April 2001
Drydock Extension · Re-Inspection
Physical examination · Activities Europe · Activity 1391562
14 June 2000
Deficiency Check
Physical examination · Activities Europe · Activity 821688
23 May 2000
Administrative
Administrative · Activities Europe · Activity 818503
9 March 2000
COI Inspection
Physical examination · Activities Europe · Activity 1365650
4 May 1999
Re-Inspection
Physical examination · Activities Europe · Activity 1122773
20 August 1998
Hull Examination
Physical examination · Activities Europe · Activity 1375482
17 August 1998
Deficiency Check
Physical examination · Activities Europe · Activity 1130983
8 July 1998
Deficiency Check
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 793746
3 June 1998
Type not recorded
No type recorded · Activities Europe · Activity 91640
1 June 1998
Deficiency Check
Physical examination · Activities Europe · Activity 795482
4 March 1998
COI Inspection
Physical examination · Activities Europe · Activity 1414990
16 January 1998
Administrative
Administrative · Activities Europe · Activity 1368551
19 March 1997
Administrative
Administrative · Activities Europe · Activity 1098250
10 March 1997
Administrative
Administrative · Activities Europe · Activity 1102463
29 April 1996
Hull Examination · COI Inspection · Deadweight Survey
Physical examination · Activities Europe · Activity 1078673
18 March 1996
Administrative
Administrative · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 884611
10 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1188287
2 February 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 840459
13 October 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1176697
16 March 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 854743
18 August 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1159122
16 August 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1157903
10 August 1993
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1157898
24 July 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1265702
20 July 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 961878
6 February 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 944346
6 January 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1256050
15 October 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 937933
13 August 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1247055
23 May 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 935093
9 April 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 934012
5 February 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1211775
26 November 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 901663
20 July 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 945445
24 May 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 913137
1 August 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 916598
19 April 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1349943
30 January 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1031936
20 July 1988
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1034103
20 July 1988
Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1341595
1 March 1988
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1295617
28 May 1987
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1028202
28 May 1987
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1336974
23 January 1986
Credit Drydock · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 996980
23 July 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 983837
Documentation
Issued 27 April 2001
Resolved
Provide proper documentation of fully compliant chemical testing program for the following deficiencies: Sample collection bottles, Alcohol testingdevice, Updated manual detailing procedures to be followed for vessels operating in West Africa. 46 CFR 16.401, 16.250, 4.06-20
Condition: Unknown
Due 27 April 2001
Resolved 27 April 2001
Documentation
Issued 9 March 2000
Resolved
Provide a copy of a valid Safety Radio Certificate.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Fire Fighting
Issued 9 March 2000
Resolved
Make permanent repairs to #1 fire station to supply a steady stream of water.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Unknown
Issued 9 March 2000
Resolved
Provide proper documentation of fully compliant chemical testing program for the following deficiencies: Sample collection bottles; alcohol testing device; updated manual detailing procedures to be followed for vessels operating in West Africa.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Accommodation/Occupational Safety
Issued 4 March 1998
Resolved
Repair walk-in feezer.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Documentation
Issued 4 March 1998
Resolved
Properly display COI and Stability letter.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Accommodation/Occupational Safety
Issued 4 March 1998
Resolved
Provide current copies of CFRs and COLREGS.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Accommodation/Occupational Safety
Issued 4 March 1998
Resolved
Renew/repair galley extractor.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Navigation
Issued 4 March 1998
Resolved
Repair fathometer.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Navigation
Issued 4 March 1998
Resolved
Update compass deviation card.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Documentation
Issued 4 March 1998
Resolved
Conduct IOPP survey by ABS Nigeria on USCG behalf and have certificate issued prior to vessel going back into service.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Engineering
Issued 4 March 1998
Resolved
Prove proper operation of vessel's oily water sperator. Until OWS is provento be operating the following must be done: Lock overboard discharge in closed position, designate an oily water "slop" tank, transfer all bilge water into designated slop tank,document all transfer to shoreside facility
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Fire Fighting
Issued 4 March 1998
Resolved
Service engine room fire extinguishers.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Lifesaving
Issued 4 March 1998
Resolved
On July 1, 1998 provide MIO Europe with a copy of the the vessel's offical log book from March through June showing the required lifesaving and firefighting drills as per 46 CFR 97.15 and 97.35.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Fire Fighting
Issued 4 March 1998
Resolved
Test fixed fire system.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Construction/Loadline
Issued 4 March 1998
Resolved
Repair bilge alarm.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Engineering
Issued 4 March 1998
Resolved
Repair overspeed devices. _x001C_ _x001C_ _x001C_ x
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Fire Fighting
Issued 4 March 1998
Resolved
Pressure test each fire hose, station and nozzle at 100PSI.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Lifesaving
Issued 4 March 1998
Resolved
Provide MIO Europe with approved rescue boat details/plans.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Documentation
Issued 16 August 1993
Resolved
SUBMIT CALCULATIONS FOR THE FIRE MONITOR PUMP AND EQUIPMENT FOR REVIEW OF STABILITY CALCULATIONS.
Condition: Unknown
Due 16 August 1993
Resolved 16 August 1993
Deck/Cargo
Issued 16 August 1993
Resolved
PROVIDE THREE RELIEF BALVES FOR BULK TANKS #1, #2, AND #3. BULK TANK NOT BEUSED UNTIL RELIEF VALVES ARE INSTALLED. REQUIREMENT #1 AND #2 ARE TO BE SUBMITTED TO THE MARINE SAFETY CENTER FOR APPROVAL. REQ #3 TO BE SUBMITTED TO THE COGIZANT [name withheld] 30NOV93. #1 & #2 15SEP93 FOR #3 REQUIREMENT.
Condition: Unknown
Due 30 August 1993
Resolved 30 August 1993
Fire Fighting
Issued 16 August 1993
Resolved
SUBMIT FIRE CONTROL PLAN SHOWING AS IS CONDITION OF VESSEL FOR APPROVAL.
Condition: Unknown
Due 16 August 1993
Resolved 16 August 1993
Electrical
Issued 24 July 1992
Resolved
REPAIR/REPLACE CARGO DECK FLOOD LIGHTS. FAX RESULTS TO [name withheld]._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 July 1992
Resolved 24 July 1992
Documentation
Issued 24 July 1992
Resolved
FAX CURRENT ENDORSED LOAD LINE CERTIFICATE TO [name withheld].
Condition: Unknown
Due 24 July 1992
Resolved 24 July 1992
Lifesaving
Issued 24 July 1992
Resolved
PROVIDE OAR LOCKS FOR RESCUE BOAT. FAX RESULTS TO [name withheld]._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 July 1992
Resolved 24 July 1992
Engineering
Issued 24 July 1992
Resolved
REPAIR #2 MDE REMOTE SHUTDOWN. FAX RESULTS TO [name withheld]._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 July 1992
Resolved 24 July 1992
Electrical
Issued 24 July 1992
Resolved
INSTALL BOTTLE LANTERNS FACING BOTH EMERGENCY ESCAPES IN E/R. FAX RESULTS TO [name withheld]._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 July 1992
Resolved 24 July 1992
Electrical
Issued 24 July 1992
Resolved
REPAIR #1 SHIP SERVICE GENERATOR OVERSPEED DEVICE. FAX RESULTS TO [name withheld].
Condition: Unknown
Due 24 July 1992
Resolved 24 July 1992
Fire Fighting
Issued 24 July 1992
Resolved
INSTALL PROPER BRACKET FOR THE FWD STBD CO2 BOTTLE, IN E/R. FAX RESULTS TO [name withheld].
Condition: Unknown
Due 24 July 1992
Resolved 24 July 1992
Engineering
Issued 24 July 1992
Resolved
STENCIL NUMBER OF TANK AT THE EMERGENCY FUEL SHUT OFF. FAX RESULTS TO [name withheld].
Condition: Unknown
Due 24 July 1992
Resolved 24 July 1992
Construction/Loadline
Issued 15 October 1991
Resolved
SUBMIT COPY TO [name withheld] OF ABS REPORT DOCUMENTING REPAIRS MADE TO BOW AREA, IN ABIDJAN IVORY COAST.
Condition: Unknown
Due 15 October 1991
Resolved 15 October 1991
Fire Fighting
Issued 26 November 1990
Resolved
REPLACE ONE 1.5 INCH BY 50' FEET FIRE HOSE WHICH RUPTURED DURING HYDROSTATIC TEST WITH APPROVED FIRE HOSE. _x001C_
Condition: Unknown
Due 26 November 1990
Resolved 26 November 1990
Electrical
Issued 1 August 1989
Resolved
PROVE THE OPERATION OF THE STARBOARD GENERATOR SET OVERSPEED TRIP.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Deck/Cargo
Issued 1 August 1989
Resolved
PROVE THE OPERATION OF THE BILGE ALARM LOCATED IN THE FORWARD BELOW DECK PASSAGEWAY.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Construction/Loadline
Issued 1 August 1989
Resolved
MAKE WATERTIGHT THE ELECTRICAL CABLE PENETRATIONS LOCATED ABOVE THE ENGINEROOM FORWARD WATERTIGHT DOOR.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Electrical
Issued 1 August 1989
Resolved
REMOVE THE NYLON WIRE TIES LOCATED ON THE OVERHEAD HORIZONTAL WIRING RUN ONTHE STARBOARD SIDE OF THE ENGINEROOM.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Fire Fighting
Issued 1 August 1989
Resolved
STENCIL THE FIRE MONITOR DIESEL ENGINE REMOTE FUEL SHUT OFF VALVE LOCATED ADJACENT TO THE SEWAGE SYSTEM AND MAKE NECESSARY MODIFICAITONS TO THE REACHROD TO PREVENT JAMMING OF THE VALVE DURING CLOSING.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Accommodation/Occupational Safety
Issued 1 August 1989
Resolved
PROVIDE AND INSTALL A SUITABLE RELIEF VALVE EQUIPPED WITH HAND LIFTING GEAR FOR THE POTABLE WATER PRESSURE TANK AND THE TOILET WATER PRESSURE TANKTHE SETTING OF THE RELIEF VALVE MUST BE AT OR BELOW THE MAXIMUM ALLOWABLE WORKING PRESSURE OF THE TANK.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Navigation
Issued 1 August 1989
Resolved
PROVIDE CURRENT CFRS, LIGHTLIST AND RULES FOR MARINE INSPECTION.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Lifesaving
Issued 1 August 1989
Resolved
REPAIR LEAK AT OLD PATCH ON STARBOARD TUBE OF RESCUE BOAT.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Navigation
Issued 1 August 1989
Resolved
PROVE OPERATION OF STARBOARD RADAR.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Lifesaving
Issued 1 August 1989
Resolved
PROVIDE PROPER CONTAINER FOR PARACHUTE FLARES.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Navigation
Issued 1 August 1989
Resolved
REPLACE ALLIGATOR CLIPS ON ALDIST LAMP CORD WITH PLUG CONNECTOR.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Electrical
Issued 1 August 1989
Resolved
PROPERLY SECURE BATTERIES IN EMERGENCY BATTERY BOX.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Electrical
Issued 1 August 1989
Resolved
REPAIR AND PROVE OPERATION OF GENERAL ALARM BELL ON MESS DECK.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Unknown
Issued 1 August 1989
Resolved
PROPERLY STORE PAINT KEPT IN STORAGE COMPARTMENT IN STARBOARD STACK.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Fire Fighting
Issued 1 August 1989
Resolved
REPAIR OR REPLACE 1 1/2" NOZZLE ON FIRE STATION NO.1
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Deck/Cargo
Issued 1 August 1989
Resolved
REPAIR/REPLACE AS ORIGINAL CHAIN STOPPERS ON ANCHOR WINDLASS.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Construction/Loadline
Issued 1 August 1989
Resolved
REPAIR BRAKES AND PROVE PROPER OPERATION OF BOTH DRUMS ON ANCHOR WINDLASS.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Fire Fighting
Issued 1 August 1989
Resolved
PROVIDE 2 COMPLETE FIREMANS OUTFIT.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Lifesaving
Issued 1 August 1989
Resolved
REPLACE THE GRABLINES ON THE INFLATABLE RESCUE BOAT.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Lifesaving
Issued 1 August 1989
Resolved
REPLACE THE LIFERINGS LOCATED ON THE AFTER END OF THE MAIN DECK HOUSE, A TOTAL OF 2 LIFERINGS.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Lifesaving
Issued 1 August 1989
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Fire Fighting
Issued 1 August 1989
Resolved
REPLACE THE TWO 1.5 INCH BY 50 FEET FIRE HOSES WHICH RUPTURED DURING THE HYDROSTATIC TEST WITH APPROVED FIRE HOSE.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Fire Fighting
Issued 1 August 1989
Resolved
COMPLETE THE SERVICING OF THE PORTABLE FIRE EXTINGUISHERS AND PROVIDE A COPY OF THE SERVICING REPORT.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Fire Fighting
Issued 1 August 1989
Resolved
PROVIDE ON BOARD THE 6 TYPE BII FIRE EXTINGUISHERS REMOVED FOR SERVICING.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Accommodation/Occupational Safety
Issued 1 August 1989
Resolved
MAKE PERMANENT REPAIRS TO THE SOFT PATCHED REFRIGERATION SYSTEM SALT WATER LINE LOCATED JUST AFT OF THE BOW THRUSTER ENGINE.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Fire Fighting
Issued 1 August 1989
Resolved
HAVE FOAM SAMPLE TAKEN AND ANALYZED AND PROVIDE A COPY OF THE ANALYSIS TO THE [name withheld].
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Navigation
Issued 20 July 1988
Resolved
INSTALL A NAVIGATION LIGHT CONTROL PANEL ALARM SYSTEM AS REQUIRED BY 46 CFR17.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Fire Fighting
Issued 20 July 1988
Resolved
REPAIR OR REPACE THE B-V DRY CHEMICAL SEMI-PORTABLE FIRE EXTINGUISHER ON THE CARGO DECK PRIOR TO THE CARRIAGE OF COMBUSTIBLE OR FLAMMIBLE LIQUIDS INPORTABLE TANKS.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988
Electrical
Issued 23 July 1985
Resolved
REPAIR AND DEMONSTRATE OVERSPEED TRIPS FOR BOW THRUSTER AND NO. 1 AND NO. 2 GENERATOR ENGINES.
Condition: Unknown
Due 23 July 1985
Resolved 23 July 1985
Electrical
Issued 23 July 1985
Resolved
RELOCATE ENGINE ROOM GENERAL ALARM BELL NEXT TO ROTATING LIGHT. ADJUST THE BELL.
Condition: Unknown
Due 23 July 1985
Resolved 23 July 1985
Unknown
Issued 23 July 1985
Resolved
PROVIDE A STANDARD DISCHARGE CONNECTION FOR OIL WASTE PUMP DISCHARGE MEETING 33 CFR 155.430.
Condition: Unknown
Due 23 July 1985
Resolved 23 July 1985
Fire Fighting
Issued 23 July 1985
Resolved
PROVIDE TWO A-II FIRE EXTINGUISHERS. ONE FOR EACH QUARTERDECK. PROVIDE SPARE.
Condition: Unknown
Due 23 July 1985
Resolved 23 July 1985
Electrical
Issued 23 July 1985
Resolved
REPLACE TACHOMETERS FOR BOW THRUSTER AND NO. 1 AND NO. 2 GENERATOR ENGINES.
Condition: Unknown
Due 23 July 1985
Resolved 23 July 1985
Electrical
Issued 23 July 1985
Resolved
PROVIDE ENCLOSURE FOR ER VENT STOP STATION AS PER 46 CFR 111.103-7.
Condition: Unknown
Due 23 July 1985
Resolved 23 July 1985
Lifesaving
Issued 23 July 1985
Resolved
RENEW EPIRB BATTERY.
Condition: Unknown
Due 23 July 1985
Resolved 23 July 1985
Electrical
Issued 23 July 1985
Resolved
REPAIR TWO RELAYS FOR REMOTE VENT AND FUEL PUMP STOPS. DEMONSTRATE ALL REMOTE SHUTDOWNS FOR VENTS AND OIL PUMPS, INCLUDING CO2 VENT STOP.
Condition: Unknown
Due 23 July 1985
Resolved 23 July 1985
Navigation
Issued 23 July 1985
Resolved
INSTALL DUAL NAVIGATION LIGHTS AND NAVIGATION LIGHT INDICATOR PANEL TO MEET46 CFR 111.75-17.
Condition: Unknown
Due 23 July 1985
Resolved 23 July 1985
Lifesaving
Issued 23 July 1985
Resolved
PROVIDE 6 WHISTLES AND 5 APPROVED LIGHTS FOR LIFE PRESERVERS.
Condition: Unknown
Due 23 July 1985
Resolved 23 July 1985
Lifesaving
Issued 23 July 1985
Resolved
SERVICE PORT AND STBD LIFERAFTS AND HYDROSTATIC RELEASES.
Condition: Unknown
Due 23 July 1985
Resolved 23 July 1985
Lifesaving
Issued 23 July 1985
Resolved
RENEW 3 RING LIFEBUOYS THAT HAVE SUN-ROTTED GRAB RINGS.
Condition: Unknown
Due 23 July 1985
Resolved 23 July 1985
Unknown
Issued 23 July 1985
Resolved
INSTALL A RELIEF VALVE ON THE HOT WATER HEATER.
Condition: Unknown
Due 23 July 1985
Resolved 23 July 1985
Fire Fighting
Issued 23 July 1985
Resolved
REPAIR FIRE ALARM SYSTEM, ONE ADDITIONAL OILER MUST BE IN THE CREW UNTIL REPAIRED.
Condition: Unknown
Due 23 July 1985
Resolved 23 July 1985
Fire Fighting
Issued 23 July 1985
Resolved
PROVIDE/REPAIR MISSING/DEFECTIVE PRESSURE GAGES FOR F/O TRANSFER, CARGO OIL TRANSFER AND ALL FIRE PUMPS.
Condition: Unknown
Due 23 July 1985
Resolved 23 July 1985
Fire Fighting
Issued 23 July 1985
Resolved
REMOVE 5 CO2 PORTABLE FIRE EXTINGUISHERS THAT WERE MODIFIED BY FOREIGN SERVICE CENTER. PROVIDE 9 BII TYPE EXTINGUISHERS AND SPARES AS FOLLOWS: 5 EACH, ER; 1-BOW THRUSTER ER; 1-PAINT LOCKER; 1-GALLEY. MODIFY SAFETY PLAN.
Condition: Unknown
Due 23 July 1985
Resolved 23 July 1985