MAURY USCG vessel records Sign in
← All vessels

GLOMAR HIGH ISLAND IX

GLOMAR HIGH ISLAND IX is a 1983 mobile offshore drilling unit. The Coast Guard has recorded 62 inspections since 1984, most recently in March 1998, along with 104 deficiencies.

Records from 1984 to 1998. Most recent: inspection, 26 March 1998.

Built
1983
Last inspected
26 March 1998
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

217000
Flag
UNITED STATES
368506000 (licence lapsed)
Maury page id
psix-217000

Inspections, by type

…with no type recorded14
Years with a record 14 calendar years (1984–1998)
The 62 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it3861 - Regulatory (Subpart C or D), Net Ton
4821 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WKPZMMSI 368506000 · expired · voluntarily equipped · granted 13 August 1997, cancelled 7 July 1998
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 62

26 March 1998 Administrative
Administrative · Activities Europe · Activity 786710
23 November 1997 Re-Inspection
Physical examination · Activities Europe · Activity 1364463
3 October 1997 Administrative
Administrative · Activities Europe · Activity 785373
26 September 1997 Administrative
Administrative · Activities Europe · Activity 1117068
24 September 1997 Administrative
Administrative · Activities Europe · Activity 1114373
28 August 1997 Administrative
Administrative · Activities Europe · Activity 785099
13 June 1997 Deficiency Check
Physical examination · Activities Europe · Activity 1450043
16 April 1997 Administrative
Administrative · Activities Europe · Activity 1364069
12 March 1997 Deficiency Check · Plan Review "T" Boat
Physical examination · Activities Europe · Activity 1103823
28 January 1997 Deficiency Check
Physical examination · Activities Europe · Activity 1102815
31 December 1996 Deficiency Check
Physical examination · Activities Europe · Activity 1095747
28 October 1996 Deficiency Check
Physical examination · Activities Europe · Activity 852184
10 October 1996 Hull Examination · COI Inspection
Physical examination · Activities Europe · Activity 1357760
9 August 1996 Administrative
Administrative · Activities Europe · Activity 1264026
20 July 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1093046
25 April 1996 Administrative
Administrative · Activities Europe · Activity 1085849
28 March 1996 Administrative
Administrative · Activities Europe · Activity 1078975
19 August 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 868225
5 August 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 860705
25 July 1994 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 9839
30 June 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 865009
11 May 1994 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1183057
2 May 1994 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 870319
1 April 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 855583
17 February 1994 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 854502
15 February 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 853068
7 December 1993 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1159786
20 October 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1153463
15 June 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1155739
12 April 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 841677
12 February 1992 Deficiency Check · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1435310
6 November 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1243645
7 October 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 933020
22 April 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922997
14 January 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1232258
20 December 1990 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1233077
10 October 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1210838
31 July 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 908844
31 July 1990 Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1224903
2 May 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 919429
3 April 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 913343
3 April 1990 Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1292463
26 January 1990 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 907535
12 December 1989 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 921445
18 July 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 889530
2 June 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1041786
20 April 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1044746
3 March 1989 Re-Inspection · Drydock Extension
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1206543
23 May 1988 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1351436
8 February 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1019808
5 January 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1012095
29 December 1987 Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1315109
2 October 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015322
6 May 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1331310
23 December 1986 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1308718
18 September 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300118
10 August 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302342
18 July 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987123
14 June 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987760
13 December 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284168
24 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1288468
27 July 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 974961

Deficiency record · 104

Lifesaving
Issued 24 September 1997 Resolved
PROVIDE MIO EUROPE WITH DOCUMENTATION FROM THE OIM THAT THE RIG HAS COMPLIED WITH THE FOLLOWING NEW (01OCT96) "IA REGULATIONS: 108.580, .649, .901, (PRINTED IN ENGLISH AND PORTUGUESE) AND 109.213.
Condition: Unknown
Due 24 September 1997
Resolved 24 September 1997
Construction/Loadline
Issued 13 June 1997 Resolved
PROVIDE ABS REPAIR PROPOSAL TO MIO EUROPE FOR (02) CRACKS IN SPUD CANS; STARBOARD LEG CHORD D AND BOW LEG CHORD A.
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Lifesaving
Issued 13 June 1997 Resolved
PROVIDE TO MIO EUROPE DOCUMENTATION FROM THE OIM THAT THE RIG HAS COMPLIED WITH THE FOLLOWING NEW (01OCT96) "IA" REGULATIONS: 108.580, 108.645 - .649,108.901 (PRINTED IN ENGLISH AND PORTUGUESE), 109.213, 109.301 AND 109.431 -435.
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Construction/Loadline
Issued 13 June 1997 Resolved
PROVIDE ABS REPAIR PROPOSAL FOR (SIX) CRACKS LOCATED IN ALL THREE LEG WELLSCORNERS (BOTTOM TO SIDE SHELL CONNECTION).
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Electrical
Issued 10 October 1996 Resolved
Submit statement from OIM attesting to the operation and testing of the rigshutdown.
Condition: Unknown
Due 31 October 1996
Resolved 28 October 1996
Construction/Loadline
Issued 10 October 1996 Resolved
Crop out and renew entirely the wasted bracket (2nd from bottom) located atthe aft inboard corner of #2 preload tank.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Fire Fighting
Issued 10 October 1996 Resolved
Provide spare portable fire extinguishers IAW 46 CFR 108.495.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Construction/Loadline
Issued 10 October 1996 Resolved
Conduct non-destructive testing of can/chord connections and spud can inspections with a USCG inspector in attendance at the next rig move.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Lifesaving
Issued 10 October 1996 Resolved
Provide all required equipment for both lifeboats.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Documentation
Issued 10 October 1996 Resolved
Submit revised fire plan and applicable revisions to the operating manual which incorporate all accomodation modifications to MIO Europe for approval.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Fire Fighting
Issued 10 October 1996 Resolved
Submit copy of recent foam analysis to MIO Europe.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Fire Fighting
Issued 10 October 1996 Resolved
Recharge the three CO2 bottles that were found to be underweight during last test of the fised system. Confirm via statement to MIO Europe when new bottles are installed on board.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Unknown
Issued 10 October 1996 Resolved
Submit statement from OIM regarding testing of the relief valve for the rigfloor air receiver.
Condition: Unknown
Due 31 October 1996
Resolved 28 October 1996
Lifesaving
Issued 19 August 1994 Resolved
MAKE PERMANENET REPAIR TO THE DAMAGED #2 LIFE CAPSULE IN AN APPROVED FACILITY TO THE SATISFACTION OF THE ATTENDING U. S. COAST GUARD MARINE INSPECTOR AND PRIOR TO RESUMING DRILLING OPS.
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Unknown
Issued 30 June 1994 Resolved
REPLACE IMPROPER GASKETS ON THE HATCHES WHERE NEEDED, AND CONDUCT CHALK TEST AFTER GASKET REPLACEMENT.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Unknown
Issued 17 February 1994 Resolved
REPLACE OUTDATED BOUYANT ROCKET FOR LINE THROWING APPARATUS.
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Unknown
Issued 17 February 1994 Resolved
REPAIR CRACKS ON STBD LIFEBOAT STBD SIDE MIDSHIP JUST ABOVE WINDOW.
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Unknown
Issued 17 February 1994 Resolved
REPLACE OUTPLACED RINGBOUY SMOKE SIGNAL STBD SIDE.
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Unknown
Issued 17 February 1994 Resolved
PROVIDE [name withheld] WITH A COPY OF SERVICING REPORT FOR PORTABLE AND SEMI PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Unknown
Issued 17 February 1994 Resolved
PROVIDE PROPER OPERATION OF HIGH JACKET WATER TEMP ON GENERATOR #2.
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Unknown
Issued 17 February 1994 Resolved
REPAIR CRACKS ON PORT LIFEBOAT PORTSIDE MIDSHIP JUST ABOVE WINDOW.
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Documentation
Issued 20 October 1993 Resolved
SUBMIT TO MARINE SAFETY CENTER FOR REVIEW INFORMATION ASSOCIATED WITH THE INSTALLATION OF VARCO TOP DRIVE REQUIRED BY 46 CFR SUBCHPATER S TO REEVALUATE MODU STABILITY AND REISSSUE STABILITY LETTER IF REQUIRED.
Condition: Unknown
Due 20 October 1993
Resolved 20 October 1993
Documentation
Issued 20 October 1993 Resolved
SUBMIT TO MARINE SAFETY CENTER FOR REVIEW CHANGES TO OPERATIONS MANUAL ASSOCIATED WITH INSTALLATION OF VARCO TOP DRIVE.
Condition: Unknown
Due 20 October 1993
Resolved 20 October 1993
Fire Fighting
Issued 12 April 1993 Resolved
REPLACE SIX (6) FIRE HOSES WITH UL APPROVED FIRE HOSE. THIS REQUIREMENT CANBE CLEARED BY PROVIDING [name withheld] OF SHIPPING INVOICE AND A LETTERFROM RIG OIM ATTESTING TO SAME._x001C_ _x001C_
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Navigation
Issued 12 April 1993 Resolved
PROVE PROPER OPERATION OF STERN LIGHT AND STBD SIDE LIGHT. VESSEL SHALL NOTBE TOWED AT NIGHT UNTIL THIS REQUIREMENT IS CLEARED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Fire Fighting
Issued 12 April 1993 Resolved
REHYDRO TEST ALL FIXED CO2 CYLINDERS AT A DOT APPROVED RETEST FACILITY. PROVIDE COPY OF SERVICING REPORT TO [name withheld]._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Lifesaving
Issued 12 April 1993 Resolved
PROVIDE RETROREFLECTIVE TAPE ON PORT AND STBD LIFE BOAT AND (9) NINE RING BOUY. THIS REQUIREMENT TO BE CLEARED BY PROVIDING [name withheld] OF INVOICE AND LETTER FROM BARGE CAPT OF SAME._x001C_ _x001C_
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Lifesaving
Issued 12 April 1993 Resolved
SERVICE ALL LIFERAFTS AT A COAST GUARD APPROVED FACILITY IN PRESENCE OF A COAST GUARD MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Fire Fighting
Issued 12 April 1993 Resolved
RENEW AND PROVE PROPER OPERATION OF MIDDLE LEL SENSOR IN THE MUD PIT ROOM._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Lifesaving
Issued 12 April 1993 Resolved
RENEW AND PROVE PROPER OPERATION OF FORWARD LEG H2S GAS SENSOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Fire Fighting
Issued 12 February 1992 Resolved
ALTER DOORS IN PORT STORAGE ROOM (CO2 STORAGE) TO OPEN OUTWARD.
Condition: Unknown
Due 12 February 1992
Resolved 12 February 1992
Unknown
Issued 12 February 1992 Resolved
SUBMIT DRAWINGS AND PLANS FOR INSTALLATION OF TOP DRIVE SYSTEM AND DERRICK EXTENSION/STRENTHENING TO MSC (MARINE SAFETY CENTER) AND OBTAIN APPROVAL.
Condition: Unknown
Due 12 February 1992
Resolved 12 February 1992
Deck/Cargo
Issued 12 February 1992 Resolved
CLEAN, GAS FREE AND MAKE AVAILABLE FOR INTERNAL INSPECTION ALL DRYBULK TANKS AT NEXT DRYDOCK.
Condition: Unknown
Due 12 February 1992
Resolved 12 February 1992
Construction/Loadline
Issued 6 November 1991 Resolved
IN PRESENCE OF MARINE INSPECTOR, CONDUCT NDE OF REPAIRS MADE OT CRACKING FOUND DURING 26-28 DEC 90 U/W EXAM OF HIGH STRESS AREAS. (SEE INSP RPRT FOREXACT LOCATIONS). THIS REQ TO BE COMPLETED AT NEXT RIG MOVE AND PRIOR TO 06DEC 91.
Condition: Unknown
Due 6 November 1991
Resolved 6 November 1991
Electrical
Issued 14 January 1991 Resolved
PROVIDE LEASHER FOR BEAM-CLAMP MOUNTED LIGHTS IN ALL HAZARDOUS LOCATIONS (AMUD PIT ROOM, SHALE SHAKER AREA, ETC.)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 January 1991
Resolved 14 January 1991
Electrical
Issued 14 January 1991 Resolved
PROVIDE LOSS OF PURGE ALARM ON WMCO PUMP STROKE COUNTER AT DRILLER'S CON-_x001C_ SOLE ON DRILL FLOOR.
Condition: Unknown
Due 14 January 1991
Resolved 14 January 1991
Electrical
Issued 14 January 1991 Resolved
REPLACE POLYRAD CABLE TO REMOTE PVT/DRILL PARAM MONITOR TO UNIT AT DRILLERSCONSOLE WITH ARMORED OR [name withheld]._x001C_
Condition: Unknown
Due 14 January 1991
Resolved 14 January 1991
Accommodation/Occupational Safety
Issued 14 January 1991 Resolved
PROVIDE KEY FOR HOSPITAL IN BREAK-GLASS BOX IN PASSAGEWAY OUTSIDE OF SPACE.
Condition: Unknown
Due 14 January 1991
Resolved 14 January 1991
Construction/Loadline
Issued 20 December 1990 Resolved
Submit to the above noted office for approval, a proposal of repair for cracking found during 26-28 December 1990 underwater exam of high stress areas. (Cracking found in various locations at shear plate to can, web _x001C_flange to chord, and gusset to chord connections on all legs)._x001C_
Condition: Unknown
Due 20 December 1990
Resolved 20 December 1990
Electrical
Issued 3 March 1989 Resolved
ENSURE NO SO CABLE IS INSTALLED ON DRILL FLOOR OR IN AND AROUND DERRICK (IE FWD PORT DERRICK LEG).
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Lifesaving
Issued 3 March 1989 Resolved
RENEW PORT SMOKE FOR PORT RING BUOY. COMPLY BY: 30MAR89
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Construction/Loadline
Issued 3 March 1989 Resolved
REINSTALL DOOR CLOSURE ON EXIT DOOR TO BELOW DECK AND WEATHER DECK FROM THE HOSPITAL SPACE. COMPLY BY: 03APR89
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Electrical
Issued 3 March 1989 Resolved
CORRECT MUD PIT VENT ALARM SENSOR TO DRILL FLOOR. AT PRESENT, THE INDICATOR LIGHT AND BELL CAME ON AND OFF DURING NORMAL OPERATION. COMPLY BY: 03APR89
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Electrical
Issued 3 March 1989 Resolved
REPLACE GENERAL ALARM BATTERYS (SEE 46 CFR 113,25 - POWER SUPPLY MUST BE 8 HOURS). COMPLY BY: 03APR89
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Electrical
Issued 3 March 1989 Resolved
REPLACE LOCK ON GENERAL ALARM ON/OFF SWITCH. COMPLY BY: 03APR89
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Electrical
Issued 3 March 1989 Resolved
RENEW BATTERY FOR RADIO WITH APPROPRIATELY SIZED BATTERY. COMPLY BY: 30MAR89
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Unknown
Issued 3 March 1989 Resolved
RENEW ALL MARINE RECEPTACLES INSTALLED IN CLASS AREAS WITH EXPLOSION PROOF RECEPTACLES.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Electrical
Issued 3 March 1989 Resolved
ENSURE EXANE CABLE IS REMOVED FROM CLASS I DIV I AREAS AND RENEWED WITH ARMOURED OR MINERAL INSULATED CABLE PRIOR TO INTERNATIONAL VOYAGE.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Electrical
Issued 3 March 1989 Resolved
MUD PIT ALARM BELL ON DRILL FLOOR SOUND THE SAME ON THE GENERAL ALARM BELL.A BUZZER MAY SERVE FOR THE AUDIBLE ALARM. COMPLY BY: 03APR89
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Electrical
Issued 3 March 1989 Resolved
CORRECT AIR SUPPLY TO DRILL FLOOR TOTALIZER. SHOULD BE OIL FREE. (SEE NFPA 496 2-2.6-1) COMPLY BY: 03APR89
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Electrical
Issued 3 March 1989 Resolved
ADJUST FAN PITCH ON MUD PIT VENT FANS SO NEGATIVE PRESSURE IS PRESENT. COMPLY BY: 03APR89
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Electrical
Issued 3 March 1989 Resolved
REMOVE SO CABLE FROM MUD PITS COMPLY BY: 03APR89
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Electrical
Issued 3 March 1989 Resolved
INSTALL EYS FITTING IN EXPLOSION PROOF RECEPTACLE LOCATED NEAR FIRE STATION#24. COMPLY BY: 30MAR89
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Electrical
Issued 3 March 1989 Resolved
LOGGERS TRAILER TO BE REMOVED FROM CLASS I DIV I AREA PRIOR TO DRILLING OPERATIONS OR REFIT TO MEET DIVISIONS REQUIREMENTS. (NFC AND NFPA 496) COMPLY BY: 30MAR89
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Deck/Cargo
Issued 3 March 1989 Resolved
ENSURE ALL BONDING STRAPS ARE IN PLACE ON FLANGE CONNECTIONS AND PUMP PIPE CONNECTIONS ON FUELING SYSTEM. COMPLY BY: 30MAR89
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Lifesaving
Issued 3 March 1989 Resolved
ENSURE PROVISIONS ARE SUPPLIED FOR SURVIVAL CRAFT PRIOR TO INTERNATIONAL VOYAGE.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Electrical
Issued 3 March 1989 Resolved
CORRECT GENERAL ALARM BELL ON DRILL FLOOR, BELL IS INOPERATIVE. COMPLY BY: 03APR89
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Unknown
Issued 3 March 1989 Resolved
CORRECT GENERAL ALARM BELL IN THE MUD PIT, BELL IS INOPERATIVE. COMPLY BY: 03APR89
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Electrical
Issued 3 March 1989 Resolved
CORRECT GENERAL ALARM BELL ABOVE THE SHELL SHAKER, BELL IS INOPERATIVE.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Unknown
Issued 3 March 1989 Resolved
PROVIDE 2 PAIR DIE-ELECTRIC GLOVES FOR THE FIREMANS OUTFITS. COMPLY BY: 03APR89
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Fire Fighting
Issued 3 March 1989 Resolved
ENSURE FIRE SHUTTER FOR TOOL PUSHER'S OFFICE AND GALLEY TO BE MADE AND INSTALLED PRIOR TO INTERNATIONAL VOYAGE.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Lifesaving
Issued 3 March 1989 Resolved
RENEW STARBOARD LIFE RAFT DAVIT HOOK PRIOR TO INTERNATIONAL VOYAGE WITH HOOK DESIGNED FOR FLOAT FREE SYSTEM.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Lifesaving
Issued 3 March 1989 Resolved
INSTALL (PROPERLY FASTEN TO DECK) FLOAT FREE ACTIVATION HOOKS PRIOR TO INTERNATIONAL VOYAGE.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Fire Fighting
Issued 29 December 1987 Resolved
CONDUCT A FIRE AND ABONDON RIG DRILL WITHIN 24 HOURS OF SETTING ON THE BOTTOM AND LOG THE SAME; SEND A COPY OF THE LOGGED ENTRY TO THE [name withheld].
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Fire Fighting
Issued 29 December 1987 Resolved
MAKE OPERABLE GENERAL ALARMS ON THE DRILL FLOOR AND MUD PIT ROOM PRIOR TO DRILLING OPERATIONS.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Unknown
Issued 29 December 1987 Resolved
MAKE OPERABLE THE PURGE AIR SYSTEM FOR THE DRILLER'S CONSOLE AND THE DRAW WORK MOTORS PRIOR TO DRILLING OPERATIONS.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Electrical
Issued 29 December 1987 Resolved
MAKE OPERABLE THE LOSS OF VENTILATION TO THE MUD PIT ROOM ALARM PRIOR TO DRILLING OPERATIONS.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Electrical
Issued 29 December 1987 Resolved
MAKE OPERABLE THE GAS DETECTION SYSTEM FOR THE MUD PIT ROOM PRIOR TO DRILLING OPERATIONS.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Deck/Cargo
Issued 29 December 1987 Resolved
REMOVE OR MAKE OPERABLE THE HELICOPTER REFUELING FACILITY.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Fire Fighting
Issued 29 December 1987 Resolved
PROVIDE BREAKABLE GLASS TO CO2 SYSTEM PULL BOXES AS NEEDED.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Deck/Cargo
Issued 29 December 1987 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Unknown
Issued 29 December 1987 Resolved
INSTALL NEW PRESSURE GAUGE FOR RIG FLOOR AIR RECEIVER.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Electrical
Issued 29 December 1987 Resolved
PRIOR TO DRILLING OPERATIONS, TEST RIG SHUTDOWN AND LOG THE SAME.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Electrical
Issued 29 December 1987 Resolved
REPAIR STARBOARD LIFERAFT LIGHTING STATION.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Fire Fighting
Issued 29 December 1987 Resolved
INSTALL NEW PULL BOX AND PRESSURE TRIP SWITCH BOX FOR PAINT LOCKER FIXED FIREFIGHTING SYSTEM PRIOR TO SUPPLYING THE PAINT LOCKER WITH FLAMMABLE LIQUIDS.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Lifesaving
Issued 29 December 1987 Resolved
INSTALL INFLATABLE RAFTS WITH CURRENT SERVICING DATES ON THE RAFTS.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Lifesaving
Issued 29 December 1987 Resolved
INSTALL NEW LIFERAFT LAUNCHING INSTRUCTIONS AT BOTH STATIONS.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Fire Fighting
Issued 29 December 1987 Resolved
MAKE OPERABLE EXISTING SMOKE DETECTORS IN ACCOMMODATION SPACES.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Fire Fighting
Issued 29 December 1987 Resolved
MAKE READY FIRE ALARMS FOR TESTING.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Fire Fighting
Issued 29 December 1987 Resolved
PROVIDE DOCUMENTATION FOR ANALYSIS OF FOAM FOR FIREFIGHTING.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Construction/Loadline
Issued 29 December 1987 Resolved
REINSTALL RAILING AT PORT SIDE CROSSOVER.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Lifesaving
Issued 29 December 1987 Resolved
PROVIDE DOCUMENTATION TO VERIFY FALLS DATE ON RENEWAL OR END FOR ENDED ON THE PORT AND STARBOARD LIFE CAPSULES.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Lifesaving
Issued 23 December 1986 Resolved
ON BOTH LIFEBOATS PROVIDE 54 LBS OF CONDENSED MILK AND CONDUCT ANNUAL FUEL CHANGE.
Condition: Unknown
Due 23 December 1986
Resolved 23 December 1986
Fire Fighting
Issued 23 December 1986 Resolved
PROVIDE EVIDENCE THAT THE FIRE FIGHTING FOAM IS SUITABLE FOR SERVICE (FOAM ANALYSIS REPORT)
Condition: Unknown
Due 23 December 1986
Resolved 23 December 1986
Lifesaving
Issued 23 December 1986 Resolved
FOR ISSUANCE OF THE IMO MODU CERTIFICATE INSTALL ON EACH LIFERAFT A HYDROSTATIC RELEASE.
Condition: Unknown
Due 23 December 1986
Resolved 23 December 1986
Unknown
Issued 18 September 1985 Resolved
PROVIDE DISCHARGE CONNECTION PRIOR TO 18OCT85.
Condition: Unknown
Due 18 September 1985
Resolved 18 September 1985
Unknown
Issued 14 June 1985 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL GLOMAR HIGH ISLAND DN656640.
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Deck/Cargo
Issued 14 June 1985 Resolved
PROVIDE UL OR FM APPROVAL ON FORKLIFT OR REMOVE IT FROM THE RIG REF 108. 613/
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Lifesaving
Issued 14 June 1985 Resolved
PROVIDE AND POST ON BOARD A STAMPED USCG APPROVED COPY OF THE FIRE CONTROL PLAN REF 46 CFR 107.305.
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Electrical
Issued 14 June 1985 Resolved
PROVIDE UL OR FM APPROVED SWITCHES TO REPLACE THE NON-APPROVED RUSSELLSTOLLSWITCHES USED FOR THE THREE MUD PRODLER MOTORS IN THE MUD PIT ROOM REF 46 CFR 111.105.
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Fire Fighting
Issued 14 June 1985 Resolved
PROVIDE PROPER MARKINGS FOR CARBON DIOXID ALARM LOCATED IN THE MUD PIT ROOMAND GENERATOR ROOM REF 46CFR108.627.
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Construction/Loadline
Issued 14 June 1985 Resolved
CONDUCT AN UNDERWATER VIDEO EXAMINATION OF LEG CANS AND LEG TO CAN CONNECT-IONS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR REF46CFR107.267.
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Electrical
Issued 14 June 1985 Resolved
PROVIDE A READABLE STAMPED APPROVED COPY OF THE HAZARDOUS CLASSIFIED LOCATION PLAN ON BOARD RIG REF 46CFR110.25.
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Electrical
Issued 14 June 1985 Resolved
PROVIDE UL OR FM APPROVED SWITCHES FOR THE NON APPROVED RUSSELLSTOLL SWITCHES LOCATED ON THE SHELL SHAKER DECK REF 46CFR111.105.
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Lifesaving
Issued 14 June 1985 Resolved
PROVIDE 1500 FEET OF AUXILLARY LINE FOR THE ROCKET LINE THROWING GUN REF 46CFR108.511.
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Deck/Cargo
Issued 14 June 1985 Resolved
PROVIDE AN APPROVED RELIEF VALVE WITH A HAND LIFTING DEVICE ON IT FOR THE DRILL FLOOR AIR RECEIVER REF46CFR61.10.
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Engineering
Issued 14 June 1985 Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION THE DRILL FLOOR AIR RECEIVER REF46 CFR61.10
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Deck/Cargo
Issued 14 June 1985 Resolved
PROVIDE MISSING LABEL TAG ON RELIEF VALVE FOR SHIP SERVICE AIR RECEIVER REF46CFR61.10
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Electrical
Issued 14 June 1985 Resolved
PROVIDE A UL OR FM APPROVED GENERAL ALARM BELL TO REPLACE NON APPROVED BELLLOCATED IN SHELL SHAKER LOCATION REF 46 CFR11.105
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Electrical
Issued 14 June 1985 Resolved
MAKE OPERATIONAL THE LOSS OF VENTILATION ALARM FOR THE MUD PIT AREA REF 46CFR108.185.
Condition: Unknown
Due 14 June 1985
Resolved 14 June 1985
Unknown
Issued 27 July 1984 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE GLOMAR HIGH ISLAND IX, DN656640.
Condition: Unknown
Due 27 July 1984
Resolved 27 July 1984
Unknown
Issued 27 July 1984 Resolved
OBTAIN AND POST A COAST GUARD APPROVED COPY OF THE SAFETY PLAN (FIREFIGHT- ING AND LIFESAVING GEAR).
Condition: Unknown
Due 27 July 1984
Resolved 27 July 1984
Unknown
Issued 27 July 1984 Resolved
OBTAIN AND PLACE ON BOARD A COAST GUARD APPROVED CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 27 July 1984
Resolved 27 July 1984
Unknown
Issued 27 July 1984 Resolved
PROPERLY INSTALL NEWLY APPROVED FLOAT FREE AND DAVIT LAUNCHED LIFERAFTS.
Condition: Unknown
Due 27 July 1984
Resolved 27 July 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.