Inspection history · 28
24 September 2025
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8243265
5 May 2025
Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8140188
13 February 2024
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7864862
23 January 2024
COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7853215
21 April 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7673080
23 May 2022
Deficiency Check
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7458968
17 May 2022
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7453578
14 April 2022
Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7430737
21 June 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 7231456
18 May 2021
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7200890
5 March 2020
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6921197
19 February 2020
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6910972
1 March 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6634820
7 January 2019
Initial Certification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6606793
14 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6512024
7 April 2016
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5856806
3 December 2009
MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3644253
29 October 2009
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3628648
12 December 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3379890
26 October 2006
MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2809114
18 October 2006
Administrative Inspection
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 2802800
24 October 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2526531
29 July 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2444181
14 July 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2466090
17 June 2005
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2393731
23 May 2003
Hawser Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1803770
8 May 2003
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1789798
20 December 1998
Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1469227
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 5 May 2025
Resolved
No person may operate a US nonoceangoing ship in the navigable waters of the United States unless it has the capacity to retain onboard all oily mixtures and is equipped to discharge to a reception facility. Vessel is not retaining oily bilge water onboard in engine room.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2025
Resolved 12 June 2026
Resolution: Cleared based on CVC appeal response
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 5 May 2025
Resolved
Each window or portlight must be capable of withstanding the maximum expected load from wind and waves. Port engine room port hole has a crack in it.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2025
Resolved 4 June 2025
Resolution: Vessel blanked off port ligth
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 5 May 2025
Resolved
Machinery systems must be maintained to provide for safe operation. There is a leak in ballast water piping at forward builkhead of engine room.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2025
Resolved 29 May 2025
Resolution: Repaired pipe.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 January 2024
Resolved
A fixed fire pump must be capable of being energized remotely from a safe place outside the engine room and at the pump. The fixed fire pump is not capable of being energized at the pump. Provide local control of the fixed fire pump.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2024
Resolved 13 February 2024
Resolution: POC provided pictures of installed switch at the fire pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 January 2024
Resolved
Electrical systems must be designed and maintained to provide safe operation. The load springs for the port and starboard generators are missing and/or in need of replacement. Replace both load springs in way of the port and starboard generators.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2024
Resolved 13 February 2024
Resolution: POC provided picture of replaced load springs on both generators.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 23 January 2024
Resolved
Each towing vessel must carry at least one appropriate size immersion suit for each person on board. The vessel was not provided with the appropriate size immersion suit for the AB. Provide the same.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 23 January 2024
Resolution: Vessel provided an appropriate sized immersion suit for the AB in the presence of a Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2024
Resolved
Marine employers shall establish programs for chemical testing on a random basis for crewmembers. The vessel did not have a current list of crewmembers enrolled in the random program. Provide the same.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2024
Resolved 29 February 2024
Resolution: POC provide list of enrolled crew.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 23 January 2024
Resolved
The Master of a towing vessel must ensure that each crewmember participates in fire-fighting drills at least once a month. The Master was unable to provide proof of the same. Provide records showing monthly fire drills for the vessel's crew.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2024
Resolved 29 February 2024
Resolution: POC provided evidence of completion of fire drills with crew.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 January 2024
Resolved
Essential equipment must be regularly tested and examined IAW the frequency required by Table 143.245(b). Provide records of testing of 1. Alarm set-points, 2. pressure vessel relief valves, 3. emergency lighting, and 4. steering fluid level alarms.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2024
Resolved 20 February 2024
Resolution: operator provided statement of testing.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 23 January 2024
Resolved
The Master must keep an accurate list of crewmembers and assigned positions. Update the crewlist/station bill to accurately reflect the update manning requirements on the COI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2024
Resolved 29 February 2024
Resolution: POC provided updated station bill.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 January 2024
Resolved
All crew members must be provided with health and safety training that includes the items listed in 46 CFR 140.515(a). This training must be documented. Provide proof of health and safety training for Nels Lund, [name withheld], and [name withheld].
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2024
Resolved 29 February 2024
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 17 May 2022
Resolved
Light fixtures in the following spaces are missing their covers/diffusers. Replace covers/diffusers for stern berthing head, stairwell overhead, and main deck FWD berthing head above sink
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
Resolution: Renewed fixtures
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 17 May 2022
Resolved
Power panel in stairwell needs to be labeled with respective current/voltage rating
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 May 2022
Resolved
TVR was not onboard/available for inspection. Provide evidence of all elements are completed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 May 2022
Resolved
Health and safety plan not onboard/available for inspection. Provide health and safety plan onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 17 May 2022
Resolved
No FCC station license or Great Lakes Agreement onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
Resolution: license and call sign renewed/assigned.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 May 2022
Resolved
No DAPI documentation available for inspection/audit. Provide DAPI documentation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 May 2022
Resolved
No fire detection annual service evidence on board. Provide servicing report for the system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2022
Resolved
12VDC battery in stairwell in missing straps and not mounted. Re-install battery straps.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 May 2022
Resolved
PORT engine exhaust has crack in stack space where exhaust penetrates the super structure. Repair crack.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 May 2022
Resolved
PORT genset gauge/control panel is ratchet strapped to genset housing. Remove strap and properly mount gauge/control panel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 May 2022
Resolved
Life jackets need proper vessel name labeled on each vest.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 May 2022
Resolved
Life jackets need lights and whistles installed on each vest.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 17 May 2022
Resolved
Immersion suits need proper vessel name labeled on them.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 May 2022
Resolved
Provide evidence of fuel oil maintenance system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 17 May 2022
Resolved
Immersion suits need lights and whistles installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 May 2022
Resolved
PORT and STBD water light lanyard are deteriorated and missing water light brackets. Replace lanyards and install brackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 May 2022
Resolved
First aid kits has expired items, Replace expired items.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 May 2022
Resolved
WTD on STBD side galley does not seal properly. Make WTD seal properly for water tight integrity.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 May 2022
Resolved
Vessel shall not operate until COI has been endorsed by OCMI.
Action required: 15 - Rectify deficiencies by next port
Resolved 23 May 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 April 2022
Resolved
The vessel's annual window for inspection expired on 5May2022. Vessel is prohibited from transporting cargo as a certificated vessel until the annual inspection can be completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 21 June 2021
Resolved
Emergency light in engine room did not automatically illuminate upon loss of power. Provide emergency lighting for internal work and living spaces either automatic battery powered or phosphorescent stips.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2021
Resolved 23 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 June 2021
Resolved
Distress signals were insufficient in number and type.
Provide quantity and type of distress signals that meet 46 CFR 141.370
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 23 May 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 June 2021
Resolved
Remove flammables or provide suitable approved stowage container.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2021
Resolved 23 May 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 June 2021
Resolved
Perform tests and record set points for engine low oil, high temp, and air system pressure relief valve set points.
Action required: 705 - Other - as specified
Due 31 December 2021
Resolved 23 May 2022
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 19 February 2020
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or and essential system develops problems that require attention. The following alarms must be provided: Low hydraulic steering fluid levels. Alarms must: Be visible and audible at each operating station. Vessel does not have a low hydraulic fluid level alarm that is visible and audible at each operating station. Install low hydraulic level visual and audible alarm at the operating station to the satisfaction of the attending Coast Guard Marine Inspector (CGMI).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2020
Resolved 5 March 2020
Resolution: Satisfactorily tested low hydraulic fluid level alarm that is visible and audible at the operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 February 2020
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. #1 and #2 Generator have wing nuts installed on the battery terminals. Make permanent connections to #1 and #2 Generator battery terminals to the satisfaction of the attending CGMI.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2020
Resolved 5 March 2020
Resolution: Verified permanent battery connections were installed on the #1 and #2 SSDG battery terminals.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 February 2020
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. The main electrical power panel in the engine room is missing the latch. Replace the power panel latch to the satisfaction of the attending Coast Guard MI.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2020
Resolved 5 March 2020
Resolution: Verified locking device was installed on the main electrical power panel in the engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 February 2020
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. The #2 Generator has an exposed opening that could result in electric shock. Cover electrical opening to the satisfaction of the attending CGMI.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2020
Resolved 5 March 2020
Resolution: Verified #2 SSDG opening was covered.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 February 2020
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. The sewage system battery cover was found in the bilge. Re-install battery cover and secure battery to the satisfaction of the attending CGMI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2020
Resolved 5 March 2020
Resolution: Verified sewage system battery and cover were secured.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 19 February 2020
Resolved
An exposed hazard such as gears and rotating machinery must be protected by a cover, guard or rail. Install covers over rotating machinery for #1 and #2 main diesel engines.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2020
Resolved 5 March 2020
Resolution: Verified guards were installed over the #1 & #2 MDE's rotating machinery.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 February 2020
Resolved
Closure devices must be provided for hull penetrations which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. CGMI identified an old electric bilge pump hose line in the fore-peak. The pump has been removed and there is not a valve or closure between the side shell and existing hose. Remove hose and cap to the satisfaction of the attending CGMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2020
Resolved 5 March 2020
Resolution: Verified bilge pump hose was removed and the overboard was capped.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 January 2019
Resolved
Vessel's engine room high level bilge alarm is inoperable. Crew are to make hourly rounds of the engine room until the audible/visible alarm is fixed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2019
Resolved 1 March 2019
Resolution: Witnessed an operational test of the high level bilge alarm from the wheelhouse and engine room. Alarm provides a visual and audible indication.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 7 January 2019
Resolved
Crewmembers immersion suits were not onboard prior to or at the start of the inspection.
Action required: 10 - Deficiency Rectified
Resolved 5 February 2019
Resolution: Immersion suits were previously ordered, however they are on back order until the first week of April 2019. Other immersion suits were brought over from another W3 Marine vessel which does not get underway.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 January 2019
Resolved
Life buoy grab lines are worn. Repair or replace to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2019
Resolved 1 March 2019
Resolution: Company replaced the lifebuoys. Lifebuoys are labeled with the vessel name and homeport.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 7 January 2019
Resolved
Vessel's hydrostatic release unit for the EPIRB expired in 2016. Vessel is limited to Lakes Bays & Sounds and Rivers routes until the HRU is replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2019
Resolved 1 March 2019
Resolution: Expired HRU replaced; new expiration date is February 2021.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 January 2019
Resolved
The water tight door located port side in the galley space does not seal completely. Additionally, the water tight hatch to the forepeak space does not seal. Make appropriate adjustments/repairs to the satisfaction of a Coast Guard marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2019
Resolved 1 March 2019
Resolution: Appropriate adjustments have been made to the WTD. Gasket material on the deck level hatch opening to the the forepeak space has been renewed.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 7 January 2019
Resolved
Vessel master has expressed doubt concerning the use of recovery equipment in an MOB drill. Crew must conduct a satisfactory MOB drill with company approved equipment, in the presence of a Coast Guard marine inspector
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2019
Resolved 1 March 2019
Resolution: MIs witnessed a satisfactory MOB drill. Vessel crew and company elected to modify the procedures for recovering unconscious personnel from the water by using a combination of a boat hook and the PFD that the deck crew would have on, iaw company policy.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 August 2018
Resolved
The vessel is currently Not broadcasting (1) IMO Number
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 September 2018
Resolved 6 March 2019
Resolution: Owner reported AIS discrepancies corrected. Used NAVCEN to verify accuracy of vessel's AIS broadcast.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 17 October 2006
Resolved
Drug testing background checks completed (49 CFR part 40.25)
Due 28 November 2006
Resolved 1 November 2006
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 17 October 2006
Resolved
EAP Requirements 46 CFR 16.401. Crewmembers have not received training before assuming safety sensitive position. Supervisor needs 1 hour EAP Training. Employer needs contact information for Substance Abuse Professional (SAP).
Due 28 November 2006
Resolved 1 November 2006