Last inspected
5 August 2020
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 August 2020
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDA5537
Flag
UNITED STATES
Maury page id
psix-21737

Documentation record

Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 5.3 ft
Registered tonnagegross 17 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLARD MARINE INC · ANAHEIM CA, UNITED STATES · built 2000
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portERIE, PA
Endorsements, as the file codes themcw_un
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Net Ton
17 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 5 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

5 August 2020 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7024589
2 May 2019 Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6677977
16 May 2018 Administrative Inspection · Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6415735
28 August 2017 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6253839
12 April 2016 Drydock Exam · Internal Structural Exam · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5852177

Deficiency record · 21

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 May 2019 Resolved
Prove proper operations of the crash compartments bilge pump shutoff valve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2019
Resolved 7 May 2019
Resolution: Attended vessel witnessing new valve installed & sat ops.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 2 May 2019 Resolved
De-water forward void and secure space cover prior to getting underway.
Action required: 10 - Deficiency Rectified
Due 2 May 2019
Resolved 2 May 2019
Resolution: All voids dewatered prior to getting underway for emergency drills.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 May 2019 Resolved
Prove proper operations of the Fire Boy system status lights. Both normal and override are extinguished.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2019
Resolved 7 May 2019
Resolution: Attended vessel witnessing new fire boy override sw installed with sat demonstration of operation and elimination of status lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 May 2019 Resolved
Provide clip with appropriate length of lanyard for ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2019
Resolved 7 May 2019
Resolution: Attended vessel witnessing new clip installed.
01 - Certificates & Documentation › 013 - Documents › Ship specific plans for the recovery of persons from the water
Issued 2 May 2019 Resolved
Post emergency procedures.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2019
Resolved 7 May 2019
Resolution: Attended vessel witnessing posted procedures.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 May 2019 Resolved
Provide first-aid kit with required contents.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2019
Resolved 7 May 2019
Resolution: Attended vessel witnessing new kit provided with current mat.
09 - Working and Living Conditions › 091 - Living Conditions › Record of inspection
Issued 2 May 2019 Resolved
Post all pages of the Certificate of Inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2019
Resolved 7 May 2019
Resolution: Attended vessel witnessing all pages of COI posted.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 22 May 2018 Resolved
Correct vessel trim prior to commercial operations iaw stability letter. NO SAIL
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2018
Resolved 20 June 2018
Resolution: Photo provided with trip sat accompanied statement provides that trim corrected with tankage.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 May 2018 Resolved
Modify emergency procedures to reflect actual course.
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 20 June 2018
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 22 May 2018 Resolved
Plug bulkhead between engine room to pilot station to make vapor tight.
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 20 June 2018
Resolution: Photo provided showing plugged access.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 22 May 2018 Resolved
Make rudder stop satisfactory as to not damage steering
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 20 June 2018
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 May 2018 Resolved
Replace required contents of first aid kit with unexpired items.
Action required: 705 - Other - as specified
Due 22 June 2018
Resolved 20 June 2018
Resolution: Email copy of receipt for first aid kit.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 May 2018 Resolved
Post COI, stability letter and emergency instructions as required.
Action required: 705 - Other - as specified
Due 22 May 2018
Resolved 20 June 2018
Resolution: All documents posted upon receipt of COI.
Fire Fighting › Fire Bucket › Quantity
Issued 20 May 2016 Resolved
Provide 02 additional fire buckets, prior to carrying passengers. Corrected prior to departure.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2016
Resolved 20 May 2016
Resolution: Corrected prior to departure.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 May 2016 Resolved
Install missing light cover on Port courtesy deck light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 13 June 2016
Resolution: Cover Installed
Communications › Audible Communications › Horn/Whistle
Issued 20 May 2016 Resolved
Provide or repair sound signaling device to appropriate decibel level.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 13 June 2016
Resolution: Sound signaling devices adequate
Navigation › Piloting/Steering › Marine Charts
Issued 20 May 2016 Resolved
Provide updated chart of area of operation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 13 June 2016
Resolution: New and current charts on board.
Engineering › Steering Gear System › Valve, Control
Issued 20 May 2016 Resolved
Prove proper emergency steering system. install bypass valve on hydraulic actuator to facilitate manual operation of rudder
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 13 June 2016
Resolution: Emergency Steering system operation satisfactory
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 20 May 2016 Resolved
Provide one additional engine room ventilation cover, prior to carrying passengers, temporary cover provided to the satisfaction of the attending MI until permanent one can be provided
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 13 June 2016
Resolution: Appropriate quantity of ventilation closures on board.
Electrical › Electrical Distribution System (service) › Conductor
Issued 20 May 2016 Resolved
Properly secure battery terminals and terminal block, corrected prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 20 May 2016
Engineering › Fuel Oil Service System › Piping
Issued 20 May 2016 Resolved
Tighten fuel tank supply and return line piping at tank tops, corrected prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2016
Resolved 20 May 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.