Records from 1985 to 1995. Most recent: inspection, 18 September 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
18 September 1995
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 873788
26 September 1994
Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1175186
8 October 1993
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 833060
2 September 1992
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 934114
17 July 1992
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 959067
9 July 1992
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1266335
10 February 1992
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1264430
2 August 1990
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1232702
18 July 1990
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1233182
1 August 1989
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 897249
29 December 1988
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1041387
1 December 1988
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 894546
31 October 1988
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 890064
30 August 1988
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 887617
18 August 1988
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1199221
29 July 1987
Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1324621
8 July 1986
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1323453
31 July 1985
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 992797
Deck/Cargo
Issued 26 September 1994
Resolved
PRESENT CARGO TANKS FOR INTERNAL EXAM PRIOR TO PLACING VESSEL INTO SERVICE BUT NOT LATER THAN NOTED COMPLIANCE DATE.
Condition: Unknown
Due 30 June 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 26 September 1994
Resolved
OPEN SKEGS AND PRESENT FOR EXAMINATION PRIOR TO PLACING VESSEL INTO SERVICEBUT NOT LATER THAN NOTED COMPLIANCE DATE.
Condition: Unknown
Due 30 June 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 26 September 1994
Resolved
REMOVE DEAD END WIRES ON STARBOARD MAIN ENGINE.
Condition: Unknown
Due 30 June 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 26 September 1994
Resolved
PROVIDE PROPERLY LINED BATTERY BOXES FOR BATTERIES IN THE COMPRESSOR ROOM. THIS ITEM IS TO BE CORRECTED PRIOR TO PLACING THE VESSEL IN SERVICE BUT NOTLATER THAN THE NOTED COMPLIANCE DATE.
Condition: Unknown
Due 30 June 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 26 September 1994
Resolved
INSTALL EXHAUST DUCTS WHICH EXTEND NEAR THE BOTTOM OF THE COMPARTMENT IN EACH MACHINERY SPACE INCLUDING THE PUMP ROOM AS PER 46 CFR 182.20-45(c). THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL IN SERVICE BUT NOTLATER THAN THE NOTED COMPLIANCE DATE.
Condition: Unknown
Due 30 June 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 26 September 1994
Resolved
PROVIDE 2 ADDITIONAL ORANGE SMOKES. THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL IN SERVICE BUT NOT LATER THAN THE NOTED COMPLIANCE DATE.
Condition: Unknown
Due 30 June 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 26 September 1994
Resolved
REINSTALL FLAME SCREENS AND CHECK BALLS PRIOR TO PLACING VESSEL INTO SERVICE BUT NOT LATER THAN NOTED COMPLIANCE DATE.
Condition: Unknown
Due 30 June 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 26 September 1994
Resolved
HYDROSTATICALLY TEST ONBOARD AIR RECEIVERS TO 1 1/4 X MAXIMUM ALLOWABLE WORKING PRESSURE IN ACCORDANCE WITH 46 CFR 61.10. THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING VESSEL IN SERVICE BUT NOT LATER THAN NOTED COMPLIANCE DATE.
Condition: Unknown
Due 30 June 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 26 September 1994
Resolved
PROVE ALL VESSEL SYSTEMS PRIOR TO PLACING VESSEL INTO SERVICE BUT NOT LATERTHAN NOTED COMPLIANCE DATE.
Condition: Unknown
Due 30 June 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 2 September 1992
Resolved
Replace all missing florescent light fixture lens covers in the machinery spaces as per 46 cfr 183.10-10.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Navigation
Issued 2 September 1992
Resolved
Make permanent repairs to the hydraulic leaks on the port and starboard steering rams as per 46 cfr 176.25-35.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Deck/Cargo
Issued 2 September 1992
Resolved
Provide ASME relief valves rated for service and pressure on the electrically fired thermal fluid heaters located in the port and stbd aft generator spaces as per 46 cfr 176.25-1 and 46 cfr 61.30-20.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Deck/Cargo
Issued 2 September 1992
Resolved
Provide evidence that the heat transfer fluid for the thermal fluid heaters(elec. fired) is compatible with the cargo and the heat generating system as per 46 cfr 52.25-15.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Lifesaving
Issued 2 September 1992
Resolved
Provide to (2) operational / calibrated oxygen/LEL meters.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Deck/Cargo
Issued 2 September 1992
Resolved
Conduct an operational test of the cargo heating system to prove proper operation of the controls and safety features as per 46 cfr 61.30-20.
Condition: Unknown
Due 15 August 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 2 September 1992
Resolved
Make available to examination the port cargo pumproom. Space was not safe for entry.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Deck/Cargo
Issued 2 September 1992
Resolved
Provide information that the stbd cargo pump electric motor is suitable fora hazardous location. Existing pumps missing required nameplate data.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Deck/Cargo
Issued 2 September 1992
Resolved
Post safe working load on the mast of the crane and provide this office with the last crane inspection report.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Deck/Cargo
Issued 2 September 1992
Resolved
Remove the kinked section of cable from the main hoist wire of the crane.
Condition: Unknown
Due 2 September 1992
Resolved 2 September 1992
Lifesaving
Issued 31 October 1988
Resolved
PROVIDE SERVICE CERTIFICATES FOR LIFE RAFTS.
Condition: Unknown
Due 31 October 1988
Resolved 31 October 1988
Lifesaving
Issued 18 August 1988
Resolved
PROVIDE SERVICE CERTIFICATES FOR LIFE RAFTS.
Condition: Unknown
Due 18 August 1988
Resolved 18 August 1988
Documentation
Issued 31 July 1985
Resolved
OBTAIN AND PLACE ON BOARD THE CERTIFICATE OF FINANCIAL RESPONSIBILITY.
Condition: Unknown
Due 31 July 1985
Resolved 31 July 1985
Documentation
Issued 31 July 1985
Resolved
OBTAIN & PLACE ON BOARD A STABILITY LETTER.
Condition: Unknown
Due 31 July 1985
Resolved 31 July 1985
Lifesaving
Issued 31 July 1985
Resolved
PLACE CLASS "A" EPIRB ON BOARD.
Condition: Unknown
Due 31 July 1985
Resolved 31 July 1985
Electrical
Issued 31 July 1985
Resolved
REPAIR OR REPLACE OVERSPEED TRIP FOR #2 GENERATOR.
Condition: Unknown
Due 31 July 1985
Resolved 31 July 1985
Lifesaving
Issued 31 July 1985
Resolved
PLACE APPROVED SUITABLE LIFE RAFT ON BOARD.
Condition: Unknown
Due 31 July 1985
Resolved 31 July 1985