01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 February 2025
No resolution recorded
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel missed
dry dock due by 31Jan2025. Authorized one-time transit
to nearest safe area to perform dry dock.
Action required: 60 - Rectify deficiencies prior to movement
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 23 April 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced.
Owner damaged recovery ladder during MOB drill rendering it non-serviceable, must replace with sufficient means of MOB recovery before carrying passengers. 46 CFR 176.808(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2024
Resolution: Owner submitted picture of new MOB ladder along with receipt, placed into service.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 March 2024
Resolved
An inspection is required before the issuance of a Certificate of Inspection. Such an inspection for certification is not made until after receipt of the application for inspection required by 176.105.
Vsl's COI expired on 03Feb2024. Restricted from the carriage of passengers until new COI is issued.
46 CFR 176.400
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2024
Resolution: Deficiency rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 July 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel experienced loss of propulsion while underway with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2023
Resolved 11 July 2023
Resolution: O/O completed repairs, replacing impeller. Deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 April 2023
Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried.
Vessel short 1 adult Type I life preserver. Restricted to carriage of 23 persons until missing life preserver is placed in service.
46 CFR 180.25-5 OLD T
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 June 2023
Resolution: New Type I PFD purchased and placed into service.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 April 2023
Resolved
On a vessel of at least 7.9m in length, a visual and audible alarm must be provided at the operating station to indicate a high water level.
High water alarm inside interior cabin port side bilge space is inoperable.
46 CFR 182.530(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 1 May 2023
Resolution: New high level installed and working as required.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 18 April 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck.
Port and starboard side shutoff valves taped over on deck side, impeding use. Starboard side shutoff valve only partially operable.
46 CFR 182.20-40(b)(3) OLD T
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 1 May 2023
Resolution: Fuel shut off fully operational.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 18 April 2023
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation.
Owner unable to determine valve direction of operation from weather deck.
46 CFR 185.608
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 1 May 2023
Resolution: Fuel shutoff valves labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 April 2023
Resolved
All vessels shall be fitted with one ring life buoy of not less than 24 inches in diameter.
Vessel's life ring exhibited signs of degradation.
46 CFR 180.30-5 OLD T
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 1 May 2023
Resolution: New life ring put into service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 April 2023
Resolved
Each waterlight must be of an approved automatic electric type, constructed in accordance with subpart 161.010 of this chapter.
Waterlight inoperable.
46 CFR 180.30-1(b) OLD T
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 1 May 2023
Resolution: Waterlight fully operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 April 2022
Resolved
Except as further modified in this section, all single screw vessels in ocean and coastwise service shall be
provided with an auxiliary steering arrangement located above the weather deck. A suitable hand tiller
Vessel missing tiller for axillary steering.
46 CFR 182.30-5 OLD T
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2022
Resolved 18 May 2022
Resolution: New tiller purchased on placed into service.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 April 2022
Resolved
Except as otherwise provided in this section, rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crews.
Multiple stanchion bolts were loose, reducing structural integrity of railings.
46 CFR 177.35-1(a) OLD T
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2022
Resolved 13 May 2022
Resolution: Recieved evidence that stanchion bolts have been tightened and sealed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 April 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock.
Fireboy wiring was left exposed, creating potential electrical hazard.
46 CFR 183.200
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2022
Resolved 13 May 2022
Resolution: Received evidence that FireBoy wires have been wrapped in heat shrink tubing and protected from exposure.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 April 2022
Resolved
The intent of this part is to insure
that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection.
Boom vang exhibited excessive wear and loss of integrity.
46 CFR 177.01-5 OLD T
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2022
Resolved 10 May 2022
Resolution: Recieved evidence that boom vang lines have been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 April 2022
Resolved
Each flare carried to meet this section must be stowed in one of the following: (1) A portable watertight container marked as required by § 185.614 of this chapter, carried at the operating station; or (2) A pyrotechnic locker secured above the freeboard deck, away from heat, in the vicinity of the operating station.
Distress signals were store in a non-watertight container below deck.
46 CFR 180.68(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2022
Resolved 18 May 2022
Resolution: New watertight container purchased and put into service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 April 2022
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
Oil identified in port side bilge. Clean bilge and determine/correct origin of leak.
46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2022
Resolved 10 May 2022
Resolution: Recieved evidence that oil was removed from bilge and leak in valve cover fixed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 April 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 2 adult life jackets taken out of service. Restricted to 24 passengers until new adult life jackets are on board. 46 CFR 180.71
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 April 2021
Resolved 3 May 2021
Resolution: Vessel O/O requested to carry only 24 passengers; reflected on new COI.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 29 April 2021
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with 80.59 once every five years. Vessel missing FCC Radio Safety Certificate. Vessel restricted to 1000 feet from shore until proof of Certificate on board. 47 CFR 80.903
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2021
Resolved 3 May 2021
Resolution: Ed Weber issued FCC Safety Cert to vessel 30Apr2021.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 April 2021
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic tests. All portable fire extinguishers and Halon system need annual servicing. 46 CFR 176.810
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 20 May 2021
Resolution: All extinguishers and Halon bottle serviced as of May 2021.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2021
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment and reasonably safe from electrical shock of personnel. Dead end wires on vessel cause electrical hazard. 46 CFR 183.01-5
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 20 May 2021
Resolution: All dead end wires removed. They were non live stereo speaker wires.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2021
Resolved
Batteries shall be so located that the gas generated in charging will be easily dissipated by natural or induced ventilation. Items are being stored on top of battery compartment causing lack of ventilation. 46 CFR 183.05-20
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 3 May 2021
Resolution: Items stored on battery compartment have been removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2021
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment and reasonably safe from electrical shock of personnel. Bolt on battery connection corroded. 46 CFR 183.01-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 3 May 2021
Resolution: Replaced bolt on battery connection
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 April 2021
Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Loose belt on engine. 46 CFR 182.05-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 20 May 2021
Resolution: Engine belt has been replaced
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 29 April 2021
Resolved
All escape hatches and other emergency exits used as a means of escape must be marked on both sides in clearly legible letters at least 2 inches high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary
by the cognizant [name withheld] labels on emergency exits (hatches) from interior space. 46 CFR 185.606
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 21 May 2021
Resolution: Emergency exits are labeled
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 April 2021
Resolved
Each ring life buoy must be marked with Type II retro reflective material. Please add retro reflective tape to ring life buoy. 46 CFR 185.604
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 21 May 2021
Resolution: Retro reflective tape has been placed on LRB.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 April 2021
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so that child size life jackets are not mistaken for adult life jackets. Child life jackets are being stored in the same compartment as adult life jackets. 46 CFR 180.78
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 21 May 2021
Resolution: Adult lifejackets are stowed in the same location (forward cabin), vsl O/O moved child lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 April 2021
Resolved
A vessel on a lakes, bays and sounds or rivers route must carry three hand red flare distress signals approved in accordance with 160.021 in sub chapter Q of this chapter and three orange smoke distress signals approved in accordance with 160.037 in sub chapter Q of this chapter. Vessel has five red flares and one orange flare. Missing one flare. 46 CFR 180.68
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 20 May 2021
Resolution: Purchased CG approved orange flares.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 April 2021
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Emergency broadcast instructions are not posted next to radio.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 21 May 2021
Resolution: Posted by radio.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 29 April 2021
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. No emergency instructions mounted on the vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 7 June 2021
Resolution: Mounted in the cabin by the door to the head.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 April 2021
Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. Certificate of Inspection not posted on-board.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 7 June 2021
Resolution: Posted in cabin.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 29 April 2021
Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible at the operating station of the vessel. Stability letter not posted onboard. 46 CFR 176.306
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 7 June 2021
Resolution: Posted in cabin.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 16 June 2020
Resolved
Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit. Master unable to produce marine radio operator's permit, vessel restricted to 1000 feet from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 October 2020
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 16 June 2020
Resolved
Vessels operating solely within 20 nm of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of 80.1101(c)(2). Vessel missing DSC capability, restricted to 1000ft from shore.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 January 2021
Resolution: Restricted vessel from 1000' from shore
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 16 June 2020
Resolved
On vessels of at least 26 feet in length, a audible and visual alarm must be provided at the operating stations to indicate high water level. Bilge alarm in Engine Room forward of the main engine does not work.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 June 2020
Resolved
A vessel must carry either a first aid kit approved under 160.041 or a kit with equivalent contents and instructions. Vessel has expired medication in first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2020
Resolved 8 October 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2020
Resolved
Each battery must be located high above the bilge, secured to protect against shifting with the roll and pitch of the vessel and free from exposure to water splash and spray. Battery inverter does not have any cover over terminals.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2020
Resolved 8 October 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 16 June 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2020
Resolved 8 October 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 June 2020
Resolved
A vessel must carry one floating waterlight. Each floating waterlight must be approved in accordance with 161.010. Vessel's ring buoy has non-approved waterlight and is restricted to daytime operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 April 2021
Resolution: New floating waterlight onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 June 2020
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in a serviceable condition must be repaired or replaced. Vessel's ring buoy grab line is deteriorated beyond use.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 June 2020
Resolved
A masthead light on a vessel of less than 20 meters in length must have a visibility of 3 miles. Vessel's masthead light is broken. Vessel restricted to daytime operations with no restricted visibility.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 October 2020
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 16 June 2020
Resolved
The master or managing owner shall instruct each crew member upon first being employed and prior to getting underway the first time on a particular vessel and at least once every three months as to the duties that the crew member is expected to perform in an emergency. Vessel has no record of drills being conducted.
Action required: 10 - Deficiency Rectified
Resolved 8 October 2020
Resolution: Cleared on spot.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 June 2020
Resolved
Construction and arrangement of a vessel must allow the safe operation of the vessel. Vessel has a frayed line on traveler that is not detailed or identified in the Preventative Maintenance Plan.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2020
Resolved 8 October 2020
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 February 2019
Resolved
All inspected sailing vessel operators should have a written Preventative Maintenance Plan (PMP) that specifically adresses their vessel's sail rigging equipment and components. Vessel's PMP was not physically on board vessel at the time of the inspection. Owner to provide a copy of PMP to the USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 February 2019
Resolved
All rigging examinations and maintenance conducted should be documented. Vessel to provide documentation of rigging inspection records to the USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2019
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 10 May 2018
Resolved
Obtain DOT approved alcohol test strips.
Due 10 June 2018
Resolved 8 June 2018
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 10 May 2018
Resolved
Maintain proper rigging inspection records and make available to CG Inspectors.
Due 10 June 2018
Resolved 5 February 2019
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 8 May 2017
Resolved
Submit monthly sail rigging inspections to Coast Guard.
Due 4 June 2017
Resolved 31 May 2017
Navigation › Piloting/Steering › US Coast Pilot
Issued 8 May 2017
Resolved
Obtain updated Coast Pilot
Due 4 June 2017
Resolved 10 May 2018
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 8 May 2017
Resolved
Update tide tables.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2017
Resolved 10 May 2017
Navigation › Piloting/Steering › Marine Charts
Issued 8 May 2017
Resolved
Obtain current marine chart of area of operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2017
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 8 May 2017
Resolved
Provide record that all fire extinguishers are currently properly serviced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2017
Engineering › Sea-water System (primary cooling) › Pump
Issued 8 May 2017
Resolved
Repair leaking impellor on main engine water pump.
Due 4 June 2017
Resolved 10 May 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 8 May 2017
Resolved
Replace tension arm on engine belts
Due 4 June 2017
Resolved 10 May 2018
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 May 2017
Resolved
Demonstrate port emergency fuel shutoff is operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2017
Sail Rigging › Deck Hardware › Shackles
Issued 4 May 2017
Resolved
Replace wire rope as marked on aft boom block.
Due 4 June 2017
Resolved 10 May 2018
Documentation › Certificates/Documents › FCC SSL
Issued 4 October 2016
Resolved
Renew vessel FCC Station Radio license & provide MI with new call sign.
Due 4 November 2016
Resolved 2 June 2017
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 4 October 2016
Resolved
Renew ripped meshing on rail courses prior to sailing with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2016
Resolution: Meshing replaced.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 2 May 2016
Resolved
Show proof of current COD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2016
Resolved 1 June 2016
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 2 May 2016
Resolved
Show proof of annual servicing and operation of engine shutdown.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2016
Resolved 1 June 2016
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 May 2016
Resolved
Conduct drills while U/W.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2016
Resolved 1 June 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 May 2016
Resolved
Show proper operation of stern light.
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 1 June 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 May 2016
Resolved
Show proper operation of high water alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2016
Resolved 1 June 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 May 2016
Resolved
Renew expired meds.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2016
Resolved 1 June 2016
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 2 May 2016
Resolved
Add vessel name to Lifering.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2016
Resolved 1 June 2016