Documentation record
Registered dimensions (L × B × D)39.8 ft × 12.7 ft × 2.7 ft
Registered tonnagegross 12 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGEORGE HERMAN HADDAWAY · NEAVITT, MD, UNITED STATES · built 1983
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDEALE, MD
Endorsements, as the file codes themfi, rec
DocumentationValid · issued 16 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Regulatory (Subpart C or D), Gross Ton
11 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 17 inspections, each with its date, unit and type; 4 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 17
28 April 2026
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8357831
13 January 2026
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8295672
2 July 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8173100
20 June 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7939307
6 December 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7834464
28 June 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7736075
22 August 2022
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7540304
11 July 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7503635
3 February 2021
COI Inspection · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7135407
17 November 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7100894
7 July 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7024100
4 June 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6704904
3 July 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6469243
16 January 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6341391
5 July 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6212190
3 February 2017
Construction Oversight · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6088028
18 March 2016
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5835935
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 July 2022
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. The vessel was missing (1) fire bucket.
46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 August 2022
Resolution: Vessel provided photo evidence of new fire buckets on board with proper markings.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 July 2022
Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. The batteries for the floating water light attached to the life float and the lifebuoy were expired.
46 CFR 176.808(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 August 2022
Resolution: Vessel operator provided photo evidence of a new floatlight battery.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 17 November 2020
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel giving consideration to provisions for a seaworthy hull. Areas of aft deck fiberglass overlay were observed flaking and deck structural integrity compromised. Provide OCMI with a repair proposal.
46 CFR 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2020
Resolved 11 July 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 17 November 2020
Resolved
Through hull fittings and shutoff valves must be metallic, unless the nonmetallic fitting and shutoff valve has been approved by the cognizant OCMI and affords an equal degree of safety and heat resistivity as that afforded by the hull. Nonmetallic portside through-hull fitting for head sink was found wasted.
46 CFR 182.720(d)(3)-(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2020
Resolved 11 July 2022