Records from 1984 to 1993. Most recent: inspection, 17 May 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 35
17 May 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 833223
9 March 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1148491
29 December 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1132934
15 December 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 830137
17 November 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1134867
25 June 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 956362
20 May 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 950867
14 April 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 953052
10 April 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 120921
24 January 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1318809
21 February 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1239246
30 January 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1211330
18 October 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 900080
26 August 1990
Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1247854
13 June 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 914010
11 June 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 911695
15 May 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1241010
28 February 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1230887
26 February 1990
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 919858
21 August 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1225499
5 July 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 890741
18 February 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1339829
29 November 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1207136
9 November 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1203267
23 August 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1349082
22 August 1988
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1043380
2 May 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1342946
26 February 1988
Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1019521
22 January 1988
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1019681
26 August 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1034984
2 February 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1326587
13 November 1985
Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1292926
23 August 1985
Credit Drydock · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1300460
4 April 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1289142
3 December 1984
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1284408
Unknown
Issued 29 December 1992
Resolved
SUBMIT TO [name withheld] OF THE PRELOAD TANK VENTS. VENTS MUST BE SIZED RELATIVE TO THE FILL LINES IN ACCORDANCE WITH 46 CFR 56.50- 85(A)(11)._x001C_ _x001C_
Condition: Unknown
Due 29 December 1992
Resolved 29 December 1992
Unknown
Issued 29 December 1992
Resolved
SUBMIT TO [name withheld] TANK PIPING ARRANGEMENT, DRAWING NO. D-934- P028, CERTIFIED BY A PROFESSIONAL ENGINEER, IN ACCORDANCE WITH 46 CFR 58.60.
Condition: Unknown
Due 29 December 1992
Resolved 29 December 1992
Electrical
Issued 29 December 1992
Resolved
SUBMIT TO G-MSC THE UNIT'S ONE LINE ELECTRICAL GENERATION AND DISTRIBUTION DIAGRAM, REVISED TO INCLUDE THE MODIFICATIONS MADE IN CONJUNCTION WITH THE BRINE PIPING SYSTEM INSTALLATION.
Condition: Unknown
Due 29 December 1992
Resolved 29 December 1992
Accommodation/Occupational Safety
Issued 24 January 1992
Resolved
PROVIDE A PROPER RELIEF VALVE FOR AIR RECEIVER #CIN81154. (LOCATED IN COMPRESSOR ROOM AND IS USED FOR BULK TANKS)
Condition: Unknown
Due 24 January 1992
Resolved 24 January 1992
Electrical
Issued 24 January 1992
Resolved
PROVE THAT THE EXISTING FORKLIFT MEETS REQUIREMENT OF 46 CFR 109.529 OR PROVIDE ONE THAT DOES.
Condition: Unknown
Due 24 January 1992
Resolved 24 January 1992
Unknown
Issued 24 January 1992
Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION OR HYDRO TEST BULK TANKS #1 THRU #4.EITHER TEST OR INSPECTION MUST BE DONE IN THE PRESENCE OF AN U.S COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 24 January 1992
Resolved 24 January 1992
Lifesaving
Issued 24 January 1992
Resolved
PROVE PROPER OPERATION OF AIR PURGE ALARM ON BOP CONSOLE ON DRILL FLOOR, TOTHE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 24 January 1992
Resolved 24 January 1992
Lifesaving
Issued 24 January 1992
Resolved
PROVIDE APPROVED RELEASE HOOK FOR DAVIT LAUNCH LIFERAFTS ON STARBOARD SIDE.
Condition: Unknown
Due 24 January 1992
Resolved 24 January 1992
Accommodation/Occupational Safety
Issued 24 January 1992
Resolved
PROVE PROPER OPERATION OF NEW RELIEF VALVE FOR AIR RECEIVER #CIN81154, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 24 January 1992
Resolved 24 January 1992
Engineering
Issued 24 January 1992
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPERATOR TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 24 January 1992
Resolved 24 January 1992
Lifesaving
Issued 28 February 1990
Resolved
PROVIDE 43 PACKAGES OF 2LBS PROVISIONS FOR LIFEBOAT NO.2. POB RESTRICTED TO7 UNTIL COMPLIANCE.
Condition: Unknown
Due 28 February 1990
Resolved 28 February 1990
Navigation
Issued 28 February 1990
Resolved
REPAIR AIRCRAFT WARNING LIGHTS AT TOP OF EACH LEG.
Condition: Unknown
Due 28 February 1990
Resolved 28 February 1990
Navigation
Issued 28 February 1990
Resolved
REPAIR AFT 2 PERIPHERAL HELO-DECK LANDING LIGHTS.
Condition: Unknown
Due 28 February 1990
Resolved 28 February 1990
Electrical
Issued 28 February 1990
Resolved
PROVIDE APPROVED PLANS FOR LARGER EMERGENCY GENERATOR REPLACEMENT PRIOR TO INSTALLATION.
Condition: Unknown
Due 28 February 1990
Resolved 28 February 1990
Unknown
Issued 28 February 1990
Resolved
PROVIDE APPROVED PLANS FOR DEEP WELL PUMP INSTALLATIONS.
Condition: Unknown
Due 28 February 1990
Resolved 28 February 1990
Lifesaving
Issued 18 February 1989
Resolved
PROVIDE A 1500' ROPE FOR THE LINE THROWING GEAR THAT HAS A BREAKING STRENGTH OF 9,000LBS.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Electrical
Issued 18 February 1989
Resolved
PROVE PROPER OPERATION OF THE PURGE AIR ALARMS AT THE DRILLER CONSOLES.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Construction/Loadline
Issued 18 February 1989
Resolved
PROVE PROPER OPERATION OF THE OILY-WATER SEPERATOR AFTER REPAIRING THE SENSING MODULE.
Condition: Unknown
Due 18 February 1989
Resolved 18 February 1989
Unknown
Issued 26 February 1988
Resolved
INSTALL ASME APPROVED SAFETY RELIEF VALVES WITH HAND RELIEF ON ALL DRY BULKTANKS SET PRESSURE NOT TO EXCEED THE MAXIMUM ALLOWABLE WORKING PRESSURE OF 40 PSIG (2.8 BAR) (OFFICE ISSUED).
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Lifesaving
Issued 26 February 1988
Resolved
PROPERLY MARK LIFEBOATS #2 & #3 IN ACCORDANCE WITH 46 CFR 108.645.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Lifesaving
Issued 26 February 1988
Resolved
PROPERLY EQUIP #2 & #3 LIFEBOATS IN ACCORDANCE WITH 46 CFR 94.20.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Construction/Loadline
Issued 26 February 1988
Resolved
MAKE ALL SPUD CANS AVAILABLE FOR INTERNAL EXAMINATION IN ORDER TO COMPLY WITH THE DRYDOCK OR SPECIAL EXAMINATION REQUIREMENTS OF 46 CFR 107.261.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Construction/Loadline
Issued 26 February 1988
Resolved
MAKE EXTERNAL CHORD CONNECTIONS ON ALL SPUD CANS AVAILABLE FOR NON- DESTRUCTIVE TESTING IN ORDER TO COMPLY WITH 46 CFR 107.261.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Construction/Loadline
Issued 26 February 1988
Resolved
EFFECT PROPER REPAIRS TO 3 CRACKS NOTED IN PORT SPUD CAN AS FOLLOWS: 40" VERTICAL CRACK ON PORT CHORD,5" CIRCUMFERENTIAL CRACK ON PORT CHORD AT TOP PLATE,& 8" CIRCUMF. CRACK ON STBD CHORD AT TOP PLATE. A WRITTEN REPAIR PRO-POSAL SHALL BE SUBMITTED TO THE COGNIZANT [name withheld] REPAIRS.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Construction/Loadline
Issued 26 February 1988
Resolved
CONDUCT CHALK TESTS ON ALL WATERTIGHT DOORS AND HATCHES ON THE MAIN DECK & ACCOMMODATION HOUSE & REPAIR, REPLACE & ADJUST DOGS AS NECESSARY. MUST BE REPLIED TO BY MAIL PRIOR TO MOVING RIG FROM FIRTH OF FORTH, SCOTLAND.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Documentation
Issued 26 February 1988
Resolved
AMEND CERITIFICATE OF DOCUMENTATION FOR CORRECT OWNER ADDRESS. THIS REQUIREMENT MAY BE REPLIED TO BY MAIL ENCLOSING A PHOTOCOPY OF THE DOCUMENT.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Lifesaving
Issued 26 February 1988
Resolved
PROVIDE (2) FLOATING ROCKETS AND (6) PRIMER CARTRIDGES FOR KILGORE IMPULSE ROCKET LINE THROWING GUN (PRIOR TO OPERATION).
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Accommodation/Occupational Safety
Issued 26 February 1988
Resolved
PROPERLY EQUIP ALL EYE WASH STATIONS PRIOR TO COMMENCING DRILLING OPERATIONS BUT NO LATER THAN 15MAR88.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Deck/Cargo
Issued 26 February 1988
Resolved
PROVE PROPER OPERATION OF PURGE AIR SYSTEM & ALARMS ON THE RIG FLOOR.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Fire Fighting
Issued 26 February 1988
Resolved
PROVIDE SERVICING REPORT FOR FIXED COMBUSTIBLE GAS SYSTEM, H2S SYSTEM, FOAM AND FIRE FIGHTING SYSTEMS.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Fire Fighting
Issued 26 February 1988
Resolved
PROVE PROPER OPERATION OF DRILL FLOOR DELUGE SYSTEM.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Deck/Cargo
Issued 26 February 1988
Resolved
CONDUCT CRANE QUADRENNIAL SURVEY PRIOR TO 03/89.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Fire Fighting
Issued 26 February 1988
Resolved
SUBMIT MODIFIED FIRE CONTROL PLAN TO [name withheld] FOR APPROVAL INDICATING NEW LOCATION OF PAINT LOCKEER HALON SYSTEM AND PROTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Fire Fighting
Issued 26 February 1988
Resolved
DEMONSTRATE PROPER OPERATION OF HALON SYSTEM PRESSURE SWITCHES FOR VENT ANDMOTOR SHUTDOWNS FOR SCR AND MAIN ENGINE ROOM.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Fire Fighting
Issued 26 February 1988
Resolved
CONDUCT FIRE AND ABANDON SHIP DRILL IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Electrical
Issued 26 February 1988
Resolved
PERMANENTLY LABEL ALL ELECTRICAL SWITCHES ON THE DRILL FLOOR.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Fire Fighting
Issued 26 February 1988
Resolved
REPLACE HOSES AT (6) FIRE STATIONS.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Fire Fighting
Issued 23 August 1985
Resolved
PROVIDE FOAM NOZZLE AND TEST FIXED FOAM SYSTEM FOR HELO FUEL TANK AREA. NOFUEL TO BE CARRIED IN THESE TANKS UNTIL SYSTEM IS PROVEN OPERATIONAL.
Condition: Unknown
Due 23 August 1985
Resolved 23 August 1985
Fire Fighting
Issued 23 August 1985
Resolved
PROVIDE A COPY OF FOAM ANALYSIS REPORT.
Condition: Unknown
Due 23 August 1985
Resolved 23 August 1985
Lifesaving
Issued 23 August 1985
Resolved
RELABEL FOUR LIFE CAPSULES IN ACCORDANCE WITH 46 CFR 108.645.
Condition: Unknown
Due 23 August 1985
Resolved 23 August 1985
Electrical
Issued 23 August 1985
Resolved
REPLACE PORT EMBARKATION LIGHT LENS.
Condition: Unknown
Due 23 August 1985
Resolved 23 August 1985
Electrical
Issued 23 August 1985
Resolved
REPLACE BROKEN GLASS GLOBES TO CLASS I, DIVISION I LIGHT ON STARBOARD SIDE DRILL FLOOR.
Condition: Unknown
Due 23 August 1985
Resolved 23 August 1985
Electrical
Issued 23 August 1985
Resolved
COMPLETE ELECTRICAL WIRING TO HEATER LOCATED NEAR THE STARBOARD SIDE OF THE "V" DOOR.
Condition: Unknown
Due 23 August 1985
Resolved 23 August 1985
Fire Fighting
Issued 23 August 1985
Resolved
REPLACE ALL STAINLESS STEEL PRESSURIZED WATER FOAM PORTABLE FIRE EXTINGUISHERS, APPROVAL DISCONTINUED PER COMMANDANT LETTER G-MVI-3 16714/ 162.028 DATED 21JUNE 1983.
Condition: Unknown
Due 23 August 1985
Resolved 23 August 1985
Fire Fighting
Issued 23 August 1985
Resolved
REPAIR ALL FIRE DOORS IN DECKHOUSE STAIRTOWER AND PROVE DOORS TO BE SELF- CLOSING.
Condition: Unknown
Due 23 August 1985
Resolved 23 August 1985
Fire Fighting
Issued 23 August 1985
Resolved
REPAIR ELEVATING ADJUSTMENT LOCKING NUT TO BOTH FORWARD AND AFTER FOAM MONITORS.
Condition: Unknown
Due 23 August 1985
Resolved 23 August 1985
Lifesaving
Issued 23 August 1985
Resolved
REPAIR SPRAY PIPE OVER COCKPIT TO #3 LIFE CAPSULE.
Condition: Unknown
Due 23 August 1985
Resolved 23 August 1985
Lifesaving
Issued 23 August 1985
Resolved
REPLACE BOLTS TO HINGES ON PORT AND STARBOARD LIFERAFT BOX COVERS.
Condition: Unknown
Due 23 August 1985
Resolved 23 August 1985
Engineering
Issued 23 August 1985
Resolved
BOTH AUXILIARY BOILERSTO BE REASSEMBLED AND TESTED.
Condition: Unknown
Due 23 August 1985
Resolved 23 August 1985
Engineering
Issued 23 August 1985
Resolved
ALL FUEL AND LUBE OIL TANK SIGHT GLASSES TO BE GLASS NOT PLEXIGLASS AND SELF-CLOSING VALVES TO BE PROVIDED ON UPPER AND LOWER ENDS OF SIGHT GLASS.
Condition: Unknown
Due 23 August 1985
Resolved 23 August 1985
Electrical
Issued 23 August 1985
Resolved
REPLACE MISSING LIGHT AT BASE OF EXTERIOR STARBOARD LADDER TO DECKHOUSE.
Condition: Unknown
Due 23 August 1985
Resolved 23 August 1985
Electrical
Issued 23 August 1985
Resolved
PROPERLY STORE ALL BATTERIES IN BATTERY ROOM IN ACCORDANCE WITH 46 CFR PART111.15.
Condition: Unknown
Due 23 August 1985
Resolved 23 August 1985
Accommodation/Occupational Safety
Issued 3 December 1984
Resolved
D-2. PROVIDE ADDITIONAL ACCESS TO STARBOARD LIFEBOATS AROUND EXIT DOOR FROMCREWS LOUNGE. ADDITIONAL ACCESS TO BE AT LEAST AS WIDE AS THE DOOR.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Fire Fighting
Issued 3 December 1984
Resolved
D-1. PROVIDE TWO 2 1/2" BY 50 FOOT FIRE HOSES WITH 7 1/2" THREADS PER INCH (NATIONAL STANDARD FIREHOSE COUPLING) TO REPLACE THE TWO FOREIGN FIRE HOSESON THE HELIDECK.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Fire Fighting
Issued 3 December 1984
Resolved
E-7. PROVE PROPER OPERATION OF REMOTE VENTILATION SHUTDOWNS TO DRY BULK ROOM PORT & STARBOARD SIDES AND DIESEL GENERATOR ROOM.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Unknown
Issued 3 December 1984
Resolved
E-6. PROVIDE ALL SIGHTGLASSES TO DAYTANKS, HYDRAULIC TANKS, AND LUBE OIL TANKS WITH PROPER GLASS SIGHTS AND PROTECTIVE GUARDS.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Electrical
Issued 3 December 1984
Resolved
E-5A. REPAIR ALL LIGHT FIXTURES ON BOTH PORT AND STARBOARD CRANE BOOMS TO COMPLY WITH CLASS I DIVISION I STANDARD.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Accommodation/Occupational Safety
Issued 3 December 1984
Resolved
E1. PROVIDE A CLASS "A-60" DOOR BETWEEN THE COMPRESSOR ROOM AND ACCOMODA- TION CORRIDOR ON THE O-1 LEVEL.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Electrical
Issued 3 December 1984
Resolved
E-5. PROVIDE PROPER LIGHT GLOBES IN MUD PIT ROOM. DEAD END WIRING TO BE PLACED IN JUNCTION BOX AND GROUNDED.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Unknown
Issued 3 December 1984
Resolved
E-4. PROVIDE GUARD FOR EXHAUST PIPING FROM THE EMERGENCY COMPRESSOR LOCATEDIN THE ENGINEROOM.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Electrical
Issued 3 December 1984
Resolved
E-3. MAKE PROPER CONNECTIONS ON ELECTRICAL WIRING TO JACKING MOTORS.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Engineering
Issued 3 December 1984
Resolved
E-2. OVERHAUL AND PROVE PROPER OPERATION OF SAFETY RELIEF VALVES TO BOTH AUXILIARY BOILERS.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984