MAURY USCG vessel records
← All vessels

KAMAHELE KAI

KAMAHELE KAI is a 1994 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2016, most recently in October 2025, along with 65 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 9 October 2025.

Built
1994
Last inspected
9 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 October 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK7998
Flag
UNITED STATES
Maury page id
psix-21904

Documentation record

Registered dimensions (L × B × D)32.0 ft × 10.1 ft × 5.0 ft
Registered tonnagegross 8 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLIGHTNIN FIBERGLASS · KILAUEA, HI, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionDiesel Outdrive
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portHALEIWA, HI
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 15 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Net Ton
8 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

9 October 2025 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8240851
28 February 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8087656
9 October 2024 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8016761
10 October 2023 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7764240
23 February 2023 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7617166
11 October 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7560001
20 May 2021 Drydock Exam · Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7191032
23 October 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7083304
24 May 2019 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6692164
7 March 2019 Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6636930
27 February 2019 Internal Structural Exam · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6633780
21 June 2017 Deficiency Check · In-Service Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6182481
10 May 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6143339
1 February 2017 Internal Structural Exam · DAPI Audit · Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6081135
13 May 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5916922

Deficiency record · 65

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 October 2025 Resolved
Where life preservers are stowed so that they are not readily visible to passengers, the containers in which they are stowed shall be marked "Life Preservers" with the number contained therein, in at least 1-inch letters and figures. This legend shall indicate the separate stowage of children's life preservers. Life preserver markings did not accurately reflect the number of life preservers stowed in each container and did not indicate a difference between stowage locations of adult preservers and children's preservers. Post required markings, reflecting accurate count of adult and children life preservers present in all containers used for life preserver stowage, in a conspicuous place, to the satisfaction of the attending CG marine inspector.46 CFR 185.30-10(a) "Old T"
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2025
Resolved 10 November 2025
Resolution: Cleared by photographs.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 9 October 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2025
Resolved 10 November 2025
Resolution: Cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 9 October 2025 Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. Present crew members did not have marine radio operator permit or higher class license present for inspection. Provide the marine radio operator permit or higher class license of a licensed crew member of the vessel to the satisfaction of the attending CG marine inspector. 47 CFR 80.159(e)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2025
Resolved 29 October 2025
Resolution: Vessel provided a copy of their FCC Marine Radio Operator Permit. Uploaded under "documents" of this section.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 9 October 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2025
Resolved 31 October 2025
Resolution: Vessel supplied MIS data collection form report.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 9 October 2025 Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Records of chemical tests were not available for inspection. Provide records of chemical testing for all crew members to the satisfaction of the attending CG marine inspector. 46 CFR 16.260(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2025
Resolved 31 October 2025
Resolution: Vessel supplied drug compliance letter and latest drug test results.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 9 October 2025 Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crew member assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Display and distribution of informational material and hot-line telephone number were not present on vessel. Display information and hot-line telephone number for crew member assistance to the satisfaction of the attending CG marine inspector. 46 CFR 16.401(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2025
Resolved 10 November 2025
Resolution: EAP info was posted.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 9 October 2024 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Man overboard drill not conducted. Conduct satisfactory man overboard drill in the presence of the attending marine inspector. 46 CFR 176.808(g)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2024
Resolution: Attended vessel and witnessed a satisfactory man overboard drill.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 October 2024 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that a fire drill be held under simulated emergency conditions to be specified by the inspector. Fire drill not conducted. Conduct satisfactory fire drill in the presence of the attending marine inspector. 46 CFR 176.810(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2024
Resolution: Attended vessel and witnessed a satisfactory fire drill.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 October 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel does not have an anchor light independent of the navigation lights. Provide anchor meeting the requirements of 33 CFR 83.30 to the satisfaction of the attending marine inspector. 46 CFR 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2024
Resolved 17 October 2024
Resolution: Attended vessel and observed the anchor light to be independent of the navigation lights.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 October 2024 Resolved
A power-driven vessel of less than 12 meters in length may, in lieu of the lights prescribed in paragraph (a) of this Rule, exhibit an all-round white light and sidelights. Vessel exhibits an all-round white light and a white stern light, which is not permitted under Navigation Rule 23. Arrange vessels navigation lights to meet prescribed lights under this rule to the satisfaction of the attending Marine Inspector. 33 CFR 83.23(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2024
Resolved 17 October 2024
Resolution: Attended vessel and witnessed the all around white light extinguished with the port, stbd, and stern navigation lights energized.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 October 2024 Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Mark vessel name and hailing port on stern of vessel to the satisfaction of the attending marine inspector. 46 CFR 67.123(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2024
Resolved 17 October 2024
Resolution: Attended the vessel and observed vessel name and hailing port clearly visible on the exterior part of the vessels stern.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 9 October 2024 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Neither the captain or the crew member aboard had a marine radio operators permit. Provide a marine operators permit to the satisfaction of the attending marine inspector. 46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2024
Resolved 2 November 2024
Resolution: Received email from vessel owner with operators permit; all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 October 2024 Resolved
Drug testing programs required by this part must be conducted in accordance with 49 CFR part 40, Procedures for Transportation Workplace Testing Programs. This subpart summarizes the responsibilities of credentialed mariners, marine employers, MRO, SAP and other chemical testing service providers in 49 CFR part 40. The regulations in 49 CFR part 40 should be consulted to determine the specific procedures which must be established and utilized. DER is in random selection pool. Provide 1) Documentation the DER removed themselves from the random selection pool; 2) Documentation formally appointing a second DER to conduct the random selection process through the consortium for the DER in the random selection pool; or 3) Documentation of a disinterested third party to conduct the random selection process. To the satisfaction of the attending marine inspector. 46 CFR 113(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2024
Resolved 18 October 2024
Resolution: Received email from vessel owner with documentation from the consortium the DER in the random selection pool has removed themselves and appointed a new company DER.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 October 2024 Resolved
EAP training program: An EAP training program must be conducted for the employer's crew members and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crew members and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. No proof of crew members and supervisory personnel training program. Provide documentation of company employees completing the training program described above. Also, provide proof of supervisory personnel completion of required additional 60 minutes of training for reasonable suspicion training to the satisfaction of the attending marine inspector. 46 CFR 16.401(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2024
Resolved 17 October 2024
Resolution: Attended vessel and the owner (DER) presented an attendance roster attesting to the meeting the requirements for EAP training program as described by the regulation.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 October 2023 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: A means to reset devices used to automatically shut down ventilation systems and engines. Pre-engineered fixed gas fire system's override switch inoperable. Repair and demonstrate that engines can be restarted to the satisfaction of a marine inspector. 46 CFR 181.420(b)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2023
Resolution: Repaired and demonstrated that engines can be restarted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 October 2023 Resolved
Each ring life buoy on a vessel must: (1) Be approved in accordance with § 160.050 in subchapter Q of this chapter; Retro-tape degraded and not functional. Replace retro tape in kind. 46 CFR 180.70(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2023
Resolution: Replaced retro tape on life ring.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 October 2023 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: space with a through-hull fitting below the deepest load waterline. The space below the operating station contained multiple through hull fittings below the waterline, with no high water alarms present. Install high water alarm in space to the satisfaction of marine inspector. 46 CFR 182.530(a)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2023
Resolved 17 October 2023
Resolution: Installed highwater alarm in space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 October 2022 Resolved
A submersible electric bilge pump may be used as a power bilge pump only on a vessel of not more than 65 feet in length carrying not more than 49 passengers, other than a ferry, provided that: The pump is listed by an independent laboratory as meeting the requirements in UL 1113. All submersible electric bilge pumps are not UL 1113 compliant. Install UL 1113 compliant submersible electric bilge pumps. 46 CFR 182.520(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2022
Resolved 8 November 2022
Resolution: All submersible electric bilge pumps are UL 1113 compliant.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 October 2022 Resolved
Conductors must be protected in accordance with their current carrying capacities. If the allowable current carrying capacity does not correspond to a standard device size, the next larger overcurrent device may be used provided it does not exceed 150 percent of the conductor current carrying capacity. Bilge pump manual/auto rocker switch fuses 20amp verse 15amp. Install 15amp cartridge fuses. 46 CFR 183.380(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2022
Resolved 11 November 2022
Resolution: Vessel rep installed 15 amp cartridge fuses throughout the vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 October 2022 Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. Bilge pumps and high level alarms have blade type fuses. Install cartridge type fuses. 46 CFR 183.380(l)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2022
Resolved 8 November 2022
Resolution: Cartridge type fuses installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 October 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to: minimize accidental personnel contact with energized parts. Both engine compartments main power positive terminal studs missing protective cover. Provide cover. 46 CFR 183.200(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2022
Resolved 8 November 2022
Resolution: Both engine compartment's main power positive terminal studs have protective covers.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 October 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit missing ammonia inhalants. Provide. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2022
Resolved 8 November 2022
Resolution: Ammonia inhalants provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 October 2022 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Missing heavy weather emergency instructions. Provide. 46 CFR 185.510(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2022
Resolved 8 November 2022
Resolution: Heavy weather emergency instructions provided.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 October 2022 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Missing both required portable lights. Provide. 46 CFR 183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2022
Resolved 8 November 2022
Resolution: Both required portable lights provided.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 11 October 2022 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Missing placard for Kapok life jacket donning instructions. Provide. 46 CFR 185.516
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2022
Resolved 8 November 2022
Resolution: Placard for Kapok life jacket donning instructions provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 October 2022 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel does not have any means to test for presence of alcohol. Provide. 46 CFR 185.212/46 CFR 4.06-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2022
Resolved 8 November 2022
Resolution: Marine employer has a sufficient number of alcohol testing devices readily accessible on board the vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 11 October 2022 Resolved
Except as otherwise provided in this section, rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers or crews. Starboard bow railing crack in multiple locations. Repair to the satisfaction of the attended MI. 46 CFR 177.35-1(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2022
Resolved 8 November 2022
Resolution: Starboard bow railing cracked in multiple locations was repaired to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2022 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Through hull ball valve in starboard engine compartment missing cap. Install plug. 46 CFR 176.800(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2022
Resolved 26 October 2022
Resolution: Received email from vessel owner of the port engine compartment through-hull valve capped.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 11 October 2022 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Port and stbd engine compartment supply vent closures obstructed by pre-engineered fixed gas extinguishing manual activation pull cable. Relocate pull cables so they no longer obstruct the supply from completely closing. 46 CFR 182.465(h)
Action required: 10 - Deficiency Rectified
Resolved 11 October 2022
Resolution: Vessel rep re-routed the pre-engineered fixed gas extinguishing manual activation pull cables so that they no longer obstruct the engine room air supply from completely closing.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 October 2022 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Port navigation light housing missing. Replace. 46 CFR 183.420
Action required: 10 - Deficiency Rectified
Resolved 11 October 2022
Resolution: Vessel's mechanic replaced port navigation light and proved proper operation to the attending MI.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 11 October 2022 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. Starboard engine compartment bilge high level alarm inoperable. Replace. 46 CFR 182.530(a)(2)
Action required: 10 - Deficiency Rectified
Resolved 13 October 2022
Resolution: Vessel's mechanic installed a new bilge high level alarm and proved proper operation to the satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 July 2021 Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke signals. A red hand flare distress signal may be substituted for any of the hand orange smoke distress signals. Vessel has eight red hand flare distress signal and three orange smoke distress signals. Vessel restricted to a Lakes/Bays/Sounds route or 30 min runs. 46CFR180.68(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 July 2021
Resolution: Received photo via email attesting to the correct number of flares being placed on board the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 July 2021 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Labeling of life jacket stowage is not separate or marked directly on the location of the child size life jackets. Provide proper labeling and stowage of life jackets. 46CFR180.78(a)(5)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2021
Resolved 20 July 2021
Resolution: Received photo via email attesting to the proper marking of the stowage location for the PFD's.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 July 2021 Resolved
Placards containing instructions for the donning and use of the life jackets abroad the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel has no donning instructions posted. Post life jacket donning instructions where clearly visible to passengers. 46CFR185.516(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2021
Resolved 20 July 2021
Resolution: Received photo via email attesting to the posting of PFD donning instructions.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 July 2021 Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. All medications in the vessel's first aid kit are expired. Replace all expired contents of first aid kit. 46CFR184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2021
Resolved 20 July 2021
Resolution: Received photo via email attesting to a valid first aid kit being placed onboard the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 July 2021 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Both main engines have exposed rotating belts. Install belt guards on both the port and starboard main engines. 46CFR177.960
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2021
Resolved 4 August 2021
Resolution: Received photo via email attesting to the installation of belt guards on the port and starboard engines.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2019 Resolved
Chemical testing of personnel must be conducted as required by this subpart and in accordance with the procedures detailed in 49 CFR part 40; Chemical drug testing program for vessel is not in accordance with procedures. Vessel is not apart of a consortium. Register vessel and employees into a consortium.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2019
Resolution: Proof of enrollment in Maratime consortium chemical testing program provided. Proof of chemical testing of vessel crew provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 March 2019 Resolved
An adult life jacket must be provided for each person carried on board; 17 adult life jackets were provided on board though the vessel is certificated to carry 19 people. Provide 2 additional adult life jackets to meet the certificated amount. ** A total of 17 people are allowed on vessel until deficiency is rectified.**
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2019
Resolution: 2 adult lifejackets provided onboard.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 March 2019 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Coast Guard Light List, Tide Tables, and U.S. Coast Pilot; Vessel's publications are out-to-date. Provide up to date publications for Coast Guard List, Tide Tables, and U.S. Coast Pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2019
Resolution: Required pubs and charts provided onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 March 2019 Resolved
A vessel not required to have a power driven fire pump must have at least three 2 1/2 gallon buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed as easily available during an emergency; Fire buckets are missing required lanyard. Attach a 3-6 foot lanyard to each fire bucket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2019
Resolution: 3 fire buckets provided onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2019 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation; Remote fuel shutoff stations are not marked. Mark remote fuel shutoff stations.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2019
Resolution: Placards marking emergency fuel shut offs installed on vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 7 March 2019 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent; The provision made to close the port side supply duct is unable to close. Repair port side supply duct.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 April 2019
Resolution: Port ventalation shut off operational and marked.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 March 2019 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10; Servicing tag on fire extinguisher is missing, provide proof fire extinguishers have been serviced.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 April 2019
Resolution: Proof of servicing required.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 7 March 2019 Resolved
On passenger decks of a ferry or of a vessel on an excursion trip the following must be installed: bulwarks, chain link fencing or wire mesh that has openings of not more than 4 inches in diameter or bars, slats, rail courses or an equivalent spaced at intervals of not more than 4 inches; vessel's stern has rail courses that has spacing more than 4 inches. Provide bulwarks, bars, slats, etc. to meet requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 April 2019
Resolution: Owner installed solid stern bullwark at transom to meet requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 March 2019 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a); Vessel is missing a required portable hand pump. Provide portable hand pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2019
Resolution: Portable hand emergency bilge pump provided onboard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 March 2019 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of International and Inland Navigation Rules; Vessel's stern light is inoperable. Repair stern light.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 April 2019
Resolution: Stern light operational.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 7 March 2019 Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80; Vessel's FCC Safety Certificate is not present on board vessel. Provide FCC Safety Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 April 2019
Resolution: Current FCC Safety Certificate provided onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 March 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons and the vessel from electrical equipment, and the electrical shock. Wiring located in engine space is uncovered. Provide cover for wiring in engine space to eliminate shock hazard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 April 2019
Resolution: Exposed electrical equipment covered to prevent shock hazard.
Communications › Radio Communications › EPIRB
Issued 21 June 2017 Resolved
EPIRB battery expired in 2016. Replace or service EPIRB and register new EPIRB, if replaced, with NOAA.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2017
Resolved 8 July 2017
Resolution: Operator purchased new EPIRB and provided proof of new NOAA registration.
Lifesaving › Hand Flares › Quantity
Issued 21 June 2017 Resolved
Provide 2 additional hand flares and 4 additional orange smoke distress signals.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2017
Resolved 8 July 2017
Resolution: Operator purchased new hand flares and carries appropriate amount.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 21 June 2017 Resolved
Provide a valid FCC Safety Certificate.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 16 August 2017
Resolution: FCC Certificate all sat.
Documentation › Certificates/Documents › Permit, Other
Issued 21 June 2017 Resolved
Provide a FCC Radio Operator permit for the Master.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 16 August 2017
Resolution: Master has FCC Operator permit.
Navigation › Piloting/Steering › Marine Charts
Issued 21 June 2017 Resolved
Provide 2017 Coast Pilot, tide tables, current tables, and current nautical charts for operating area.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 16 August 2017
Resolution: Charts and publications for 2017 are onboard.
Communications › Radio Communications › VHF Radiotelephone
Issued 21 June 2017 Resolved
Provide an emergency broadcast placard next to the VHF installation with vessel specific emergency instructions.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 16 August 2017
Resolution: Emergency broadcast placard at operating station.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 21 June 2017 Resolved
Provide vessel specific emergency instructions to include: rough weather at sea, flooding, fire, and man overboard procedures.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 16 August 2017
Resolution: Emergency instructions updated with required information specific to vessel.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 21 June 2017 Resolved
Prove proper operation of bilge pumps required to be in each watertight compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2017
Resolved 8 July 2017
Resolution: Bilge pumps verified to be operational.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 21 June 2017 Resolved
Prove operation of the main engine compartment fire suppression system detection circuit. Removing detection circuit for one engine must automatically secure individual engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2017
Resolved 8 July 2017
Resolution: Engines independently shut down when fire boy detection circuit is removed.
Construction/Loadline › Structures › Machinery Space Opening
Issued 21 June 2017 Resolved
Make engine compartments vapor tight to seal fixed fire extinguishing agent in compartment when released.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2017
Resolved 8 July 2017
Resolution: Engine compartments sealed vapor tight with fire retardant expansion foam.
Electrical › Electric Supply System (service) › Battery Charger
Issued 21 June 2017 Resolved
Provide manufacturer specifications for newly installed alternator on main engine.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 16 August 2017
Resolution: Alternator specifications sent to Inspections Division; all sat.
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 June 2017 Resolved
Provide electrical drawings for all systems currently installed on the vessel.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 16 August 2017
Resolution: Electrical drawings submitted and verified onboard; all sat.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 21 June 2017 Resolved
Install 30 x 30 flame screens on fuel vent pipe outlets port and starboard.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 16 August 2017
Resolution: Flame screens installed in fuel tank vents.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 21 June 2017 Resolved
Provide suitable covers for terminal connections located in the engine compartment.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 16 August 2017
Resolution: Terminal connections and covers appeared satisfactory in engine compartment.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 21 June 2017 Resolved
Provide a suitable hull strainer for the circulating salt water intake line on the diesel propulsion engine system.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 16 August 2017
Resolution: Hull strainer installed. Acrylic bowl installed and will be replaced with metallic strainer by operator.
Fire Fighting › Fire Bucket › Availability
Issued 21 June 2017 Resolved
Provide three 2 1/2 gallon fire buckets with an attached lanyard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2017
Resolved 8 July 2017
Resolution: Three 2 1/2 gallon fire buckets purchased and onboard.
Engineering › Fuel Oil Service System › Filter
Issued 21 June 2017 Resolved
A metal strainer or filter shall be provided in the main engine fuel supply line. Stainers must be of the top opening type. Strainer and filter bowls shall be metal. Glass strainers are accepted if approved under ASTM F1201 standard.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 16 August 2017
Resolution: Fuel filters and metallic bowls installed; all sat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.