Records from 1989 to 2017. Most recent: inspection, 26 April 2017.
Documentation record
Registered dimensions (L × B × D)98.1 ft × 40.0 ft × 7.8 ft
Registered tonnagegross 186 / net 127
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUN CONTRACTORS INC · HARVEY, LA, UNITED STATES · built 1983
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it127 - Regulatory (Subpart C or D), Net Ton
186 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 44
26 April 2017
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 6133632
17 May 2016
Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5878575
18 March 2014
Annual Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4821773
8 May 2012
Examination of Repairs · Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4305267
4 February 2012
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4239137
13 September 2010
Examination of Repairs · Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3863065
1 April 2009
Re-Inspection · Examination of Repairs · Administrative Inspection · Ballast Water Examination · Hull Examination · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3444431
14 May 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3207538
1 May 2008
MTSA Verification · Examination of Repairs · Ballast Water Examination · Annual Inspection · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3201956
12 April 2007
Internal Structural Exam · Ballast Water Examination · Hull Examination · MTSA/ISPS Verification · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2906370
22 May 2006
MTSA Verification · COI Inspection · Deficiency Check · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2655639
23 November 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2539923
16 June 2005
MTSA Verification · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2392701
16 December 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2260367
29 March 2004
Examination of Repairs · Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2017854
22 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972309
13 August 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1879975
31 January 2002
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1482909
19 April 2001
Examination of Repairs · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469670
15 May 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462088
17 August 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778184
22 June 1999
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1192109
12 March 1999
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408269
6 February 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445312
4 February 1997
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424341
3 February 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1106980
28 February 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1360418
16 March 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 866597
1 February 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403905
25 October 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 107040
18 February 1994
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358310
1 October 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 848581
27 May 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 644259
13 May 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 834614
12 February 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467370
1 February 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 92350
2 September 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 958612
13 January 1992
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1265272
3 January 1992
Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1010097
1 February 1991
COI Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1235923
10 May 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1216643
23 February 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929826
21 February 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1229293
1 February 1989
Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1210088
Lifesaving › Buoyant Apparatus › Approval
Issued 13 September 2010
Resolved
Replace or serivice holed buoyant apparatus
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2010
Resolution: New buoyant apparatus purchased
Stability › Freeing Ports › General
Issued 22 May 2006
Resolved
Provide approved Kg curve.
Action required: 705 - Other - as specified
Due 22 May 2007
Resolved 25 May 2006
Resolution: Provided a copy of stability review by mmt along with approval letter.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 22 May 2006
Resolved
Per NVIC 8-91 vessel hydraulic jacking system must substantially meet the requirements of 46 CFR 58.30 and 56.30. Provide 3rd party inspection of all system components to identify systems as "fail safe" and any components not rated for maximum system operating pressure. Repair/replace all identified components. Provide approved (MSC) plans of vessel hydraulic system prior to next annual inspection
Action required: 705 - Other - as specified
Due 22 May 2007
Resolved 7 June 2007
Deck/Cargo
Issued 15 May 2000
Resolved
PROVIDE PROPER LOAD CHARTS FOR PORT/STBD DECK CRANES, REPRESENTING DYNAMIC/STATIC LOADS AND NUMBER OF FALLS USED, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 May 2000
Resolved 15 May 2000
Lifesaving
Issued 12 March 1999
Resolved
DEMONSTRATE COMPLIANCE WITH DISTRICT 8 POLICY LETTER DATED 12NOV98, "RESCUEBOAT REQUIREMENTS FOR OFFSHORE SUPPLY VESSELS".
Condition: Unknown
Due 12 March 1999
Resolved 12 March 1999
Unknown
Issued 1 February 1989
Resolved
DRAW PORT AND STARBOARD TAILSHAFTS FOR EXAMINATION.
Condition: Unknown
Due 1 February 1989
Resolved 1 February 1989
Unknown
Issued 1 February 1989
Resolved
PROVIDE SUITABLE INSTRUCTIONS FOR OPERATION OF FIXED CO2 SYSTEM AT CONTROL STATION.
Condition: Unknown
Due 1 February 1989
Resolved 1 February 1989
Unknown
Issued 1 February 1989
Resolved
PROVIDE APPROVED STABILITY BOOKLET AND OPERATING MANUAL.
Condition: Unknown
Due 1 February 1989
Resolved 1 February 1989
Unknown
Issued 1 February 1989
Resolved
PROVIDE APPROVED STRUCTURAL AND ENGINEERING PLANS FOR THE VESSEL.
Condition: Unknown
Due 1 February 1989
Resolved 1 February 1989
Unknown
Issued 1 February 1989
Resolved
PROVIDE AN APPROVED RESCUE BOAT AND A MEANS TO LAUNCH AND RETRIEVE IT.
Condition: Unknown
Due 1 February 1989
Resolved 1 February 1989
Unknown
Issued 1 February 1989
Resolved
PROVIDE A SUITABLE ANCHOR AND CABLE.
Condition: Unknown
Due 1 February 1989
Resolved 1 February 1989