Records from 1993 to 2025. Most recent: inspection, 1 April 2025.
Documentation record
Registered dimensions (L × B × D)56.0 ft × 22.0 ft × 7.5 ft
Registered tonnagegross 64 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARINE BUILDERS, INC · CLARKSVILLE, IN, UNITED STATES · built 1983
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLAMAR, IN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 July 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Simplified, Net Ton
64 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 24
1 April 2025
COI Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8103218
10 April 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7892886
20 July 2023
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7795874
8 June 2023
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7659187
26 May 2022
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7442534
16 June 2021
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7232841
13 June 2020
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7042397
21 May 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6957133
18 January 2019
Administrative Inspection · Deficiency Check · Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6612102
11 November 2018
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6579851
17 April 2018
DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6394603
27 October 2016
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6032420
23 February 2016
DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5821906
14 June 2011
Industry Initiated Exam · Administration · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4044668
5 December 2010
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3913277
27 October 2010
Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3879535
4 May 2003
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1827168
17 January 2002
Annual Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1479434
4 February 1999
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 651593
19 January 1999
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 424724
8 January 1997
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 752844
6 January 1997
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 193120
10 August 1993
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 688001
29 July 1993
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 120906
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 June 2023
Resolved
Found ring buoy starboard side bridge wing to have torn and faded retro reflective material. replace retro or replace ring buoy, was looking to see if the deficiency has been taken care of.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2023
Resolved 21 June 2023
Resolution: The ring buoy has been replaced with all the required reflective material
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 July 2020
Resolved
Vessel's Ring Life Bouys not equiped with proper float light. Vessel to install float light that meets the requirements in 46 CFR 141.360.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 June 2021
Resolution: Vessel's Ring life buoys are equiped with proper float lights.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 July 2020
Resolved
Vessel's Light List is expired. Vessel to update Light List for area of operation, this requirement can be meet with either paper (duly updated annually) or electronic means.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2021
Resolution: Vessel's light list is up to date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 July 2020
Resolved
Vessel's left rudder's hydraulic lines chaffing on deck plates. Vessel to alter lines to prevent chaffing and undue wear to steering systems.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2021
Resolution: Vessel has applied chaffing gear to the hydraulic lines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 June 2020
Resolved
Vessel experienced a loss of propulsion on 12 Jun 2020 due to a failed head gasket on Port MDE, necessitating replacement of the MDE. ITV is not authorized to operate until cleared by CG.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2020
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 2 April 2019
Resolved
MDE alarm system malfunctioning at the time of the inspection and indicating "port engine tachometer" every several minutes. Unable to test main engine low lubricating oil pressure alarm, main engine high cooling water temperature alarm, and other alarms required by 46 CFR 143.230. Note: the high bilge alarm in the engine room was functioning properly.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2019
Resolved 15 May 2019
Resolution: Item cleared during follow-up inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2019
Resolved
Throw over switch for switching generators worn out and in need of replacement. In order to switch generators safely, vessel power must be shut off first.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2019
Resolved 15 May 2019
Resolution: Item cleared during follow-up inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 2 April 2019
Resolved
No lagging at elbows of port and starboard MDE exhaust within reach of crewmembers.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2019
Resolved 15 May 2019
Resolution: Item cleared during follow-up inspection.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 2 April 2019
Resolved
No navigational assessment was in pilothouse.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2019
Resolved 15 May 2019
Resolution: Item cleared during follow-up inspection.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 April 2019
Resolved
Excessive oil in bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2019
Resolved 15 May 2019
Resolution: Item cleared during follow-up inspection.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 2 April 2019
Resolved
Install caps or plugs on goose neck vents located on port and starboard side of engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2019
Resolved 15 May 2019
Resolution: Item cleared during follow-up inspection.
Unknown
Issued 19 January 1999
Resolved
LOG OF VESSEL TESTS AND INSPECTIONS WAS NOT BEING KEPT.
Condition: Unknown
Due 19 February 1999
Resolved 24 March 1999
Documentation
Issued 19 January 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 February 1999
Resolved 24 March 1999
Navigation
Issued 19 January 1999
Resolved
VESSEL DID NOT HAVE A COPY OF THE CG LIGHT LIST ON BOARD.
Condition: Unknown
Due 19 February 1999
Resolved 24 March 1999
Lifesaving
Issued 19 January 1999
Resolved
RING BUOYS ON OUTSIDE PILOT HOUSE BADLY WORN AND UNSERVICEABLE. BOTH WEREREPLACED IMMEDIATELY BY COMPANY OFFICIALS.
Condition: Unknown
Due 19 January 1999
Resolved 20 January 1999
Unknown
Issued 19 January 1999
Resolved
HAILING PORT DISPLAYED ON STERN READ PORT OF ST. LOUIS. HAILING PORT OF CERTIFICATE OF DOCUMENTATION READ PORT OF CLEVELAND, OHIO.
Condition: Unknown
Due 19 February 1999
Resolved 24 March 1999
Navigation
Issued 19 January 1999
Resolved
Vessels stern light was inoperative, wires had been pulled loose from outlet, leaving exposed wires hanging._x001C_ Company electricians came onboard to make repairs. Discrepancy had not beencorrected prior to completion of boarding.
Condition: Unknown
Due 19 February 1999
Resolved 24 March 1999
Navigation
Issued 19 January 1999
Resolved
CHARTS FOR AREA TRANSITING WERE OUTDATED. CHARTS ON VESSEL WERE DATED 1989.CURRENT EDITION OF CHARTS PLACED ONBOARD VESSEL VIA FAX.
Condition: Unknown
Due 19 January 1999
Resolved 20 January 1999
Navigation
Issued 19 January 1999
Resolved
The port running light was inoperative, crewman replaced bulb and correcteddiscrepancy.
Condition: Unknown
Due 19 January 1999
Resolved 21 January 1999
Accommodation/Occupational Safety
Issued 19 January 1999
Resolved
THE MSD ON THE VESSEL DID NOT HAVE ANY CHEMICAL TABLETS IN THE RESEVOIR._x001C_ COMPANY OFFICIALS PURCHASED TABLETS FROM LOCAL STORES AN FILLED RESEVOIR PRIOR TO USING MSD.
Condition: Unknown
Due 19 January 1999
Resolved 21 January 1999
Navigation
Issued 19 January 1999
Resolved
VESSEL DID NOT HAVE A COPY OF LOCAL NOTICE TO MARINERS ON BOARD.
Condition: Unknown
Due 19 February 1999
Resolved 24 March 1999