Records from 2016 to 2026. Most recent: inspection, 11 August 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)40.0 ft × 13.7 ft × 8.0 ft
Registered tonnagegross 30 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTROJAN YACHT · ELKTON, MD, UNITED STATES · built 1980
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHESAPEAKE BEACH, MD
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 28 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Net Ton
30 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
17 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 17
11 August 2026
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8461392
16 July 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8190922
29 January 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8072121
18 July 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7961459
25 August 2023
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7780935
25 July 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7751469
22 September 2022
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7564327
7 April 2022
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7426731
25 January 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7388353
27 July 2021
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7269583
6 August 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7025962
23 July 2019
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6755000
15 January 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6610020
8 August 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6504774
8 May 2017
DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6139479
19 July 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5949270
7 January 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5793840
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 July 2023
Resolved
The equipment required for lifefloats and buoyant apparatus must meet the following specifications: the painter must: (i) Be of at least 30.5 meters (100 feet) in length, but not less than 3 times the distance between the deck where the life float or buoyant apparatus it serves is stowed and the lowest load waterline of the vessel. The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. The number of persons capacity must be marked or painted in clearly legible letters and numbers on each side of the bow of each rescue boat. Vessel's painter and vessel's name on paddles was found
to be wasted. Life float did not have persons capacity marked on each side.
46CFR180.175(f)(3)(i)
46CFR185.604(g)
46CFR185.604(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2023
Resolved 25 August 2023
Resolution: Vessel owner set photographic evidence of corrected deficiencies to the satisfaction of the CG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 July 2023
Resolved
Each ring buoy shall be fitted with four beckets located at equidistant points about the body of the buoy. The ring life buoy beckets were found to be wasted.
46CFR160.050-4(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2023
Resolved 25 August 2023
Resolution: Vessel owner set photographic evidence of corrected deficiencies to the satisfaction of the CG Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 July 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Vessels first aid kit container is not watertight.
46CFR184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2023
Resolved 25 August 2023
Resolution: Vessel owner set photographic evidence of corrected deficiencies to the satisfaction of the CG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 April 2022
Resolved
46 CFR 181.420(a)(3)- A pre-engineered fixed gas fire extinguishing system must automatically shut down all engines that draw intake air from within the protected space. The emergency generator is not tied into the fireboy system.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 April 2022
Resolution: Generator now shuts down when fireboy is activated and is able to start utilizing the overide function to the satisfaction of the attending CG Marine Inspectoe.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 7 April 2022
Resolved
46 CFR 184.402 - Except as otherwise provided in this section every vessel must be fitted with a magnetic compass designed for marine use, to be mounted at the primary operating station. Except on vessels limited to daytime operations, the compass must be illuminated. Vessel did not have a magnetic compass.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2022
Resolution: Installed ,agnetic compass at operating station as required.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 April 2022
Resolved
46 CFR 185.700 - Each survival craft on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times while the vessel is underway. The life float's external protective covering requires repair due to multiple slices through it.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 September 2022
Resolution: Owner replaced 10 person life float with a new one.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 July 2021
Resolved
Each life float must be fitted with a lifeline, pandants, two paddles, a painter, and a light. Vessel had rotten paddles and the waterlight battery was expired.
46 CFR 180.175(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 28 September 2021
Resolution: Owner sent photos of new life float paddles and waterlight battery.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 July 2021
Resolved
For a life float-Approved under approval series 160.027 or other standard specified by the Commandant. SOLAS tape on life float was no longer reflective and needs to be replaced.
46 CFR 180.200(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 28 September 2021
Resolution: Owner submitted photos of repaired life float retro.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 July 2021
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate high water level. Vessel bilge alarm light did not work when alarm was energized.
46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2021
Resolved 28 September 2021
Resolution: Owner replaced high bilge alarm.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 July 2021
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all engines that draw intake air from within the protected space. The emergency generator is not tied into the fireboy system. Correct by next fire company annual servicing.
46 CFR 181.420(a)(3)
Action required: 705 - Other - as specified
Resolved 5 October 2021
Resolution: Witnessed satisfactory test of fire boy shut down on generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 August 2020
Resolved
Ensure that a vessel of at least 26 ft in length has a visual and audable alarm at operating station to indicate a high water level in each of normally unmanned spaces.
Vessel has inoperable float switch on fwd bilge hi water and inoperable light and alarm for aft bilge pump in generator space. 46 CFR 182.530
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2020
Resolution: O/O provided resolution evidence via email of repairs and light operation.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 August 2018
Resolved
Lfe flaot worn, repair/replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2018
Resolved 29 August 2018
Resolution: Received via email PICS of repaired Life Float.
Engineering › Lubricating Oil Storage/Transfer System › Gauge
Issued 8 May 2017
Resolved
Vessel's stbd main diesel engine's oil pressure gauge indicated high oil pressure and additionally alarmed the low oil pressure alarm when backing off throttles. Provide service report attesting to proper operation of stbd mde and/or gauge.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 17 May 2017
Resolution: Owner/operator installed manual gauge and demonstrated proper operation of manual guage.
Lifesaving › Lifefloat › Retroreflective Material
Issued 8 May 2017
Resolved
Retro on life float not proper type. Ensure SOLAS approved retro is on life float.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 17 May 2017
Resolution: Owner/operator used proper retroflective tape.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 8 May 2017
Resolved
Child life jackets not properly seperated from adult. Ensure child's lifejackets are seperated from adult PFD's.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 17 May 2017
Resolution: Owner/operator properly divided life jackets
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 8 May 2017
Resolved
Vessel has 500 cu ft fireboay installed in engine compartment and is required to have a 600 cu ft. system.
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 21 June 2017
Resolution: Owner/operator installed a 600 cf HFC 227 model.
Lifesaving › Lifefloat › Retroreflective Material
Issued 19 July 2016
Resolved
Add Retro-reflective tape to the bottom of lifefloat as required in 46 CFR 160.010-4(p)
Due 3 August 2016
Resolved 22 July 2016
Resolution: Verified via electronic photograph that O/Op added SOLAS retro-reflective tape as required to vessels lifefloat