Inspection record

Last inspected 20 March 2026
…with no type recorded16
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9228148
Flag
UNITED STATES
Maury page id
psix-22091

Documentation record

Registered dimensions (L × B × D)600.3 ft × 105.8 ft × 54.7 ft
Registered tonnagegross 28,836 / net 16,811
ITC dimensions (L × B × D)600.3 ft × 105.8 ft × 54.7 ft
ITC tonnagegross 28,836 / net 16,811
BuilderOSHIMA SHIPYARD · NAGASAKI, JAPAN · built 2001
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Endorsements, as the file codes themreg
DocumentationValid · issued 19 September 2025 · expires 30 September 2026
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16811 - Convention (Subpart B), Net Ton
50601 - Dead Weight, Ton
28836 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 50 inspections, each with its date, unit and type; 42 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 50

20 March 2026 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8329163
11 March 2026 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8324743
26 February 2026 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8317015
6 January 2026 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8290712
14 August 2025 Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8210007
2 June 2025 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8149911
28 February 2025 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8086327
17 November 2024 Type not recorded
No type recorded · Activities Europe · Activity 8036875
11 September 2024 COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7997126
24 February 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7870034
18 January 2024 MTSA/ISPS Verification · Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7849806
11 July 2023 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7739453
31 May 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7701625
17 May 2023 Administrative Inspection · ACP Additional Oversight – Risk Assessment
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7690531
17 March 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7652362
7 February 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7633749
14 January 2023 ACP Drydock Oversight
Administrative · Activities Europe · Activity 7619055
20 November 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7612485
17 November 2022 Administrative Inspection · Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7596227
8 February 2022 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7393084
8 February 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7394828
8 February 2022 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7395957
2 February 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7389701
22 December 2021 MTSA/ISPS Verification · Deficiency Check · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7369153
21 December 2021 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7369429
20 December 2021 COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7370694
10 July 2021 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7251188
30 October 2020 Annual Inspection · ACP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7081376
9 July 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7001689
9 April 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6937340
9 October 2019 MTSA/ISPS Verification · Ballast Water Examination · ACP COI Oversight · Administrative Inspection · Re-Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6835040
2 August 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6858026
14 July 2019 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6911589
19 March 2019 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6645178
18 March 2019 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6644357
12 December 2018 MTSA/ISPS Verification · ACP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6596679
17 October 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6562978
24 September 2018 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6547660
17 July 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6483334
3 July 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6465668
24 January 2018 ACP Periodic Oversight · Deficiency Check · Periodic Inspection · MTSA/ISPS Verification · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6343224
16 September 2017 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6263842
3 July 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6195379
2 April 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6333384
20 January 2017 Ballast Water Examination · Administrative Inspection · Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6065506
11 January 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6069147
11 January 2017 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6069576
6 November 2016 Type not recorded
No type recorded · Activities Europe · Activity 6042856
6 July 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5946926
25 March 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5840404

Deficiency record · 42

01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 8 September 2025 Resolved
In all ships, general arrangement plans shall show clearly for each deck the various fire sections enclosed by “A” class division and sections enclosed by “B” class divisions. The Fire Control Plan designates the corridor where the entrance to the Officer’s Laundry is located as an “A” class division. The door to the Officer’s Laundry is a B-15 rated fire door. 74 SOLAS (01)II-2/20.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2025
Resolved 11 September 2025
Resolution: Class survey report isssued.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 September 2025 Resolved
The fire resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. The 02 self-closing "A" class doors inboard from the galley leading to the passageway are binding on the door jam and will not close without forcefully pulling them shut. 74 SOLAS (01)II-2/47.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2025
Resolved 11 September 2025
Resolution: Class survey report issued.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 May 2023 Resolved
Every lifebuoy shall if it is intended to operate the quick-release arrangement provided for the self-activated smoke signals and self-igniting lights, have a mass of not less than 4 kg. Ring buoys by both bridge wings do not weight 4 kg. 74 SOLAS (20) III/20LSA Code 2.1.1.7 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 5 June 2023
Resolution: Accepted as condition of class.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 May 2023 Resolved
Doors required to be self-closing shall be fitted with hold backs. However, hold-back arrangements fitted with remote release devices of the fail-safe type me be utilized. A class boundary door from gally to dry stores is required to be self-closing. Door did not have self-closing door. 74 SOLAS (01) II-2/47.2 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 5 June 2023
Resolution: Accepted as condition of class.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 May 2023 Resolved
For ships constructed on or after 1 July 2014, a minimum of two two-way portable radiotelephone apparatus for each fire party for fire party for fire-fighter’s communication shall be carried. Each fire fighting team had only one two two-way portable radio. 74 SOLAS (20) II-2/10.10.4 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 5 June 2023
Resolution: Accepted as condition of class.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 22 May 2023 Resolved
Terminations and joints in all conductors shall be so made as to retain the original electrical, mechanical, flame-retarding and, where necessary, fire-resisting properties of the cable. Starboard davit limit switch cable is currently exposing the conductors due to deterioration of the cable insulation and sheathing. 74 SOLAS (01) II-1/45.5.5 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 5 June 2023
Resolution: Accepted as condition of class.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 May 2023 Resolved
Electrical installation shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. Laundry’s equipment power cords are currently connected to an extension cord rather than directly connected to its respective receptacle. Also, junction boxes next to lighting distribution panel on the forward bulkhead of the bosn’s hole are dangling. Additionally, some of the junction boxes are not properly sealed (missing glands). 74 SOLAS (01) II-1/ 40.1.3 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 5 June 2023
Resolution: Accepted as condition of class.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 May 2023 Resolved
Terminations and joints in all conductors shall be so made as to retain the original electrical, mechanical, flame-retarding and, where necessary, fire-resisting properties of the cable. Lighting fixture in bosn’s hole had a splice using wire-nuts outside the fixture and not within its enclosure. 74 SOLAS (01) II-1/45.5.5 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 5 June 2023
Resolution: Accepted as condition of class.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 22 May 2023 Resolved
The following arrangements shall be tested in accordance with the fire test procedures code: fire dampers, including relevant means of operation. Supply fire damper for emergency generator room seized and could not operate. 74 SOLAS (01) II-2/48 – Ref. 16.11.1 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 5 June 2023
Resolution: Accepted as condition of class.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 May 2023 Resolved
Suitable instruction and components spares for testing and maintenance shall be provided. Crew could not provide correct testing equipment for testing flame eye detector above main engine. Could not provide a known testing temperature device for testing in Engine Control Room (ECR). 74 SOLAS (01) II-2/13.1.12 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 5 June 2023
Resolution: Accepted as condition of class.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 May 2023 Resolved
Doors required to be self-closing shall be fitted with hold backs. However, hold-back arrangements fitted with remote release devices of the fail-safe type me be utilized. MI’s observed several doors throughout inspect to have hold back hooks that would not of the fail safe type on Galley door, A deck gear locker and crew change out room. 74 SOLAS (01) II-2/47.2 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 5 June 2023
Resolution: Accepted as condition of class.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 May 2023 Resolved
Fire-extinguishing appliances shall be kept in good working order and be available for immediate use at all times. MI’s observed CO2 activation box in A deck repair locker to be broken and hanging by the air connection points. 74 SOLAS (01) II-2/21 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2023
Resolved 5 June 2023
Resolution: Accepted as condition of class.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 22 May 2023 Resolved
Any discharge into the sea of oil or oily mixtures from ships shall be prohibited. Oil containment drain holes missing proper mechanical plug (03 on the port side and 01 on the starboard side). MARPOL (17) Annex I/ 15.1 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 5 June 2023
Resolution: Accepted as condition of class.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 22 May 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. 02 galley's vent screens are currently clogged with cooking grease residue. 74 SOLAS (20) 1/11 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2023
Resolved 5 June 2023
Resolution: Accepted as condition of class.
05 - Radio Communications › N/A - No Subsystem › INMARSAT ship earth station
Issued 22 May 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. 74 SOLAS (20) 1/11 50A According to master's turnover notes inmarsat is currently not working as intended.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 5 June 2023
Resolution: Accepted as condition of class.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 November 2022 Resolved
The emergency source of electrical power shall be capable, having regard to starting currents and the transitory nature of certain loads, of supplying simultaneously at least the following services for the periods specified hereinafter, if they depend upon an electrical source for their operation: 2.1 For a period of 36 h, emergency lighting: at every muster and embarkation station and over the sides as required by regulations III/11.4 and III/16.7 Marine Inspector observed multiple emergency lighting fixtures extinguished at the port and starboard muster stations and boatswains hole. 74 SOLAS (2004) II-1/42.2.1.1 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2022
Resolved 6 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 November 2022 Resolved
Illustrations and instructions in appropriate languages shall be posted in passenger cabins and be conspicuously displayed at muster stations and other passenger spaces to inform passengers of: the method of donning lifejackets. Marine Inspector discovered missing lifejacket instructions at port and starboard muster stations. 74 SOLAS (2004)III/8.4 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2022
Resolved 6 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 21 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Marine Inspector discovered port and starboard lifeboat davit limit switches seized. 74 SOLAS (2004) I/11 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2022
Resolved 6 December 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Marine Inspector discovered leak in ships air piping on port side main deck. 74 SOLAS (2004) I/11 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2022
Resolved 6 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 21 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Marine Inspector discovered rusted and broken bolts on port and starboard lifeboat rub-rail flashing. 74 SOLAS (2004) I/11 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2022
Resolved 6 December 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 November 2022 Resolved
The purpose of this regulation is to mitigate the consequences of fire by means of proper instructions for training and drills of persons on board in correct procedures under emergency conditions. For this purpose,the crew shall have the necessary knowledge and skills to handle fire emergency cases, including passenger care. Requirements include instructions, duties and organization. Marine Inspector discovered missing instructions for galley installed fire fighting system. 74 SOLAS (2004) II-2/15.1 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2022
Resolved 6 December 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 November 2022 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures other than power-operated watertight doors and those which are normally locked shall satisfy the following requirements:.1 the doors shall be self-closing and be capable of closing with an angle of inclination of up to 3.5° opposing closure. Marine Inspector discovered broken armature on galley fire door. 74 SOLAS (2004)II-2/9.4 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2022
Resolved 6 December 2022
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 21 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Marine Inspector discovered multiple holes in inner stair-tower bulkheads. 74 SOLAS (2004) I/11 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2022
Resolved 6 December 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 21 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Marine Inspector discovered multiple watertight doors to weatherdeck warped and not capable of creating tight seal. 74 SOLAS (2004) I/11 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2022
Resolved 6 December 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Marine Inspector discovered broken refractory inside ship incinerator. 74 SOLAS (2004) I/11 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2022
Resolved 6 December 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 November 2022 Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. Marine Inspector discovered leaking hydraulic hose on emergency generator. 74 SOLAS (2004) II-1/31.1 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2022
Resolved 6 December 2022
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 21 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Marine inspector discovered fractured step on ladder in engine room. 74 SOLAS (2004) I/11 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2022
Resolved 6 December 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2022 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Marine Inspector discovered exposed wiring located in CO2 compartment. 74 SOLAS (2004) II-1/45.1.3 50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2022
Resolved 6 December 2022
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 January 2022 Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs. At least once every 10 years the following inspections should be carried out for the specified equipment. Perform a hydrostatic test and internal examination of 10 percent of the system's extinguishing agent and pilot cylinders. If one or more cylinders fail, a total of 50 per cent of the onboard cylinders should be tested. If further cylinders fail, all cylinders should be tested. Last hydro of the CO2 cylinders was on Oct 2011. Vessel restricted to domestic voyages until a satisfactory 10 year test is conducted.
Action required: 702 - Prior to embarking on international voyage
Due 10 February 2022
Resolved 26 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2022 Resolved
Where main or auxiliary machinery including pressure vessels or any parts of such machinery are subject to internal pressure and may be subject to dangerous overpressure, means shall be provided where practicable to protect against such excessive pressure. Ships service air receivers do not have relief valves installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2022
Resolved 2 March 2022
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 10 January 2022 Resolved
Except as provided in paragraph 4.2.2, two means of escape shall be provided from each machinery space of category A. In particular, one of the following provisions shall be complied with Self-closing fire doors of the same fire integrity standards shall be fitted in the enclosure. Forward engine-room vertical escape trunk door failed to self-close.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2022
Resolved 26 January 2022
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 January 2022 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. Wiring for lighting fixtures in engine room are not terminating in the lighting fixture.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2022
Resolved 11 February 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 January 2022 Resolved
The Administration shall take appropriate steps to ensure uniformity in the implementation and application of the provisions of this part in respect of electrical installations.* (* Refer to the recommendations published by the International Electrotechnical Commission and, in particular, Publication 92 – Electrical Installations in Ships.) Insulation on emergency switchboard handrails are cracked, exposing metal and creating a shock hazard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 January 2022
Resolved 2 February 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 January 2022 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. #2 ships service generator high jacketwater temp switch failed to secure the generator as per the ships automated test procedures.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2022
Resolved 11 February 2022
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 10 January 2022 Resolved
Every crew member shall participate in at least one abandon ship drill and one fire drill every month. Vessel has minimum crew onboard and is currently not operating. Satisfactory drills to be conducted in the presence of a USCG Marine Inspector prior to operating.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 10 January 2022 Resolved
Except as provided in paragraphs 3.4.4 and 3.4.5, each lifeboat shall be launched, and maneuvered in the water by its assigned operating crew, at least once every three months during an abandon ship drill. Vessel was only able to launch lifeboats twice in calendar year 2021. Due to port constraints vessel had not lowered lifeboats in the water since Aug 2021. Vessel must demonstrate to the USCG port lifeboat maneuvered in the water. Vessel to transit to Houston [name withheld] and lower at anchorage there.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2022
Resolved 2 February 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 December 2018 Resolved
The boundary bulkheads and decks separating the accommodations and control stations from cargo and machinery spaces, galleys, main pantries and storerooms, other than small service lockers, shall be of "A" Class construction. Modifications made to the A-60 fire boundary door, between the engine room entrance and the crew changing area, have caused A-60 certification to be invalid. Additional fire boundary doors throughout the vessel shall be marked with proper classification labels and without modifications or alterations of fire rating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 January 2019
Resolved 28 January 2019
Resolution: We have accepted the condition of Class Report.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 21 December 2018 Resolved
It is the intent of this subpart to provide such markings as are necessary for the guidance of the person on board in case of an emergency. Markings for the General Alarm are inadequate and shall be identified by red lettering at least 1/2 inch high. Vessel owner must notify class society of deficiencies. Deficiencies are to be cleared to the satisfaction of ABS or Coast Guard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 January 2019
Resolved 28 January 2019
Resolution: We have accepted the condition of Class Report.
Engineering › Steering Gear System › Feedback Unit
Issued 24 January 2018 Resolved
During steering test from bridge, steering pedestal indicator did not match rudder angle indicator. Test conducted on system 1 both pumps with 5 degree difference between pedestal and rudder angle indicator. Rudder angle indicator did match fixed indicator at aft steering. Tests conducted in follow-up mode. Deficiency shall be rectified prior to departing Columbia River system to satisfaction of ABS and attending USCG inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2018
Resolution: Received satisfactory class report attesting to correction of steering deficiency and satisfactory operational test.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 11 January 2017 Resolved
Maintain manned engine room for maneuvering from Bolivar Roads anchorage to Houston Cement dock. In addition, post and maintain a live fire watch in way of the main engine with adequate CO2 extinguishing agent until the main diesel oil booster pump is secured at the berth. Chief Engineer is to monitor adequate dissel oil pressure during meneuvering.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2017
Resolved 20 January 2017
Resolution: Vsl maintained fire watch and made necessary repairs. All sat.
Engineering › Fuel Oil Service System › Piping
Issued 11 January 2017 Resolved
Remove and replace oil soaked lagging and flange shield covering in way of the main engine port side mid level (engine side controls) and tank top, to the satisfation of the attending ACP ACS (ABS) surveyor.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2017
Resolution: Vessel crew replaced all oil soaked lagging.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 11 January 2017 Resolved
Extensive diesel oil leakages noted in way of the #6 main engine fuel oil pump presenting a risk of fire hazard. Upon closer examination, additional leakages noted in way of the #2 and #5 fuel oil pumps. Main engine fuel pumps #2, #5, & #6 are to be overhauled and cleared of any leakages and #1, #3, & #4 to be examined internally to the satisfation of the attending ACP ACS (ABS) surveyor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2017
Resolution: Vsl had all fuel pumps overhauled and provided a tech report.