MAURY USCG vessel records Sign in
← All vessels

OH CHUTE

OH CHUTE is a 2001 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 2001, most recently in July 2024, along with 58 deficiencies and 2 casualty investigations between 2009 and 2015.

Records from 2001 to 2024. Most recent: inspection, 24 July 2024.

Built
2001
Last inspected
24 July 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN6939
Flag
UNITED STATES
368303840
Maury page id
psix-22124

Inspections, by type

…with no type recorded1
Years with a record 20 calendar years (2001–2024)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · LAKE HAVASU CITY, AZ, UNITED STATES · built 2001
Hull materialFRP (Fiberglass)
PropulsionGasoline Engine
Hull shapeShip
Hull configurationMonohull
Hailing portDANA POINT, CA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 10 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Net Ton
13 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN6939MMSI 368303840 · active · compulsorily equipped · granted 23 March 2023, expires 23 March 2033
WDB4048MMSI 366894140 · expired · compulsorily equipped · granted 17 May 2003, cancelled 20 July 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 29

24 July 2024 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7946728
27 March 2023 Internal Structural Exam · Hull Examination · COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7641097
9 September 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7555237
17 August 2021 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7208355
5 October 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7070078
31 July 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7037704
10 May 2019 Administrative Inspection · Deficiency Check · Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6681392
23 May 2018 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6414904
12 May 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6147550
1 June 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5894468
11 June 2014 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4888130
3 May 2012 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4298552
3 April 2009 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3445696
3 April 2009 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3447665
8 July 2008 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3253311
17 June 2008 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3234681
19 June 2007 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3006893
2 May 2006 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2638521
4 April 2006 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2616697
8 August 2005 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2455627
1 June 2004 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2139094
27 May 2004 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2080176
26 May 2004 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2080694
14 May 2004 Annual Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2060463
21 May 2003 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1803790
30 April 2003 Hull Examination · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1782161
24 June 2002 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1646955
3 April 2001 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1466776
22 February 2001 Initial Certification · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1389316

Deficiency record · 58

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 October 2020 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942. Vessel's fuel supply line did not meet SAE J-1942 standards or equivalency. 46CFR182.720(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 October 2020
Resolution: Operator replaced fuel supply hose with an approved type.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 October 2020 Resolved
A mechanical exhaust system consisting of at least two ventilation exhaust ducts located at the end of the space opposite from where the supply ducts are fitted, which extend to the lowest part of the bilge of the space on each side of the space, and which are led to one or more powered exhaust blowers. Vessel's starboard vent fan was inoperable. 46CFR182.460(a)(ii)
Action required: 10 - Deficiency Rectified
Resolved 5 October 2020
Resolution: Company engineer troubleshot the fan and produced satisfactory results.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2019 Resolved
An inspection for renewal of COI is conducted to determine if the vessel is in satisfactory condition including its structure, machinery, and equipment. Vessels parasailing winch cable frayed at last several feet. Operator stated cable had been replaced within last operating season, and documents 10" sections are removed weekly. Inspector has required vessel to prove when cable was installed or "end for end" the cable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 15 May 2019
Resolution: Completed day following inspection.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 May 2017 Resolved
Vessel did not have proper markings IAW 46 CFR 185.604(b). Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 12 May 2017
Resolution: Operator marked life buoy with vessel name as per 46 CFR 185.604(b).
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 8 June 2016 Resolved
Prove proper operation of fixed fireboy alarm panel: visual and audible indicators of discharge
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2016
Resolved 9 June 2016
Resolution: Provided new alarm panel and conducted proper tests to satisfaction of MI.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 8 June 2016 Resolved
Monitor & log weekly: cracked welds on port gas tank where flange attaches to new hydraulic tank. Notify CG of any changes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 6 October 2016
Resolution: Vessel continues to monitor cracked weld and has not reported any changes. Cleared deficiency and included a special note for Inspectors to monitor during next annual.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 3 April 2009 Resolved
Demonstrate proper operation of high water bilge alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 3 April 2009 Resolved
Replace forward portable fire extinguisher located on bow of vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Lifesaving › Lifebuoys › Serviceable
Issued 3 April 2009 Resolved
Replace ring life buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 3 April 2009 Resolved
Replace guard for rotating machinery.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Fire Fighting › Ventilation Systems › Ducts
Issued 3 April 2009 Resolved
Provide ventilation covers to engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Communications › Radio Communications › EPIRB
Issued 3 April 2009 Resolved
Provide documentation showing EPIRB registration through NOAA.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Documentation › Certificates/Documents › FCC SSL
Issued 8 July 2008 Resolved
FCC safety certificate expired.
Due 1 August 2008
Resolved 1 August 2008
Fire Fighting › Ventilation Systems › Ducts
Issued 8 July 2008 Resolved
Reposition powered ventilation, ducts in engine room.
Due 1 August 2008
Resolved 1 August 2008
Documentation › Markings/Placards › Garbage Placard
Issued 8 July 2008 Resolved
Provide a legible MARPOL garbage placard.
Due 1 August 2008
Resolved 1 August 2008
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 17 June 2008 Resolved
Clean bilge, and have ready for inspection.
Due 17 June 2008
Resolved 19 June 2008
Construction/Loadline › Hull › Weld
Issued 17 June 2008 Resolved
Repair broken weld on port bracket.
Due 17 June 2008
Resolved 19 June 2008
Communications › Radio Communications › EPIRB
Issued 19 June 2007 Resolved
Provide proof a current EPIRB registration. 46CFR180.64
Action required: 705 - Other - as specified
Due 19 July 2007
Resolved 26 June 2007
Personnel › Certificates/Documents/Licenses › License, Master
Issued 19 June 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 19 July 2007
Resolved 26 June 2007
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 19 June 2007 Resolved
Obtain current Tide and Current Tables. 46CFR184.420
Action required: 705 - Other - as specified
Due 19 July 2007
Resolved 26 June 2007
Documentation › Certificates/Documents › FCC SSL
Issued 8 August 2005 Resolved
Provide valid FCC Marine Radio Operator Permit. 47 CFR 80.
Action required: 705 - Other - as specified
Due 8 September 2005
Resolved 2 May 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 August 2005 Resolved
Replace expired medication in first aid kit. 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 8 September 2005
Resolved 17 August 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 August 2005 Resolved
Demonstrate proper operation of bilge high level alarm. 46 CFR 182.530.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2005
Lifesaving › Lifebuoys › Serviceable
Issued 8 August 2005 Resolved
Replace retro-reflective material and line on ring life buoy. 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 8 September 2005
Resolved 17 August 2005
Personnel › Certificates/Documents/Licenses
Issued 26 May 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2004
Personnel
Issued 26 May 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2004
Communications › Radio Communications › VHF Radiotelephone
Issued 6 May 2004 Resolved
Provide FCC operators permit prior to operating beyond 1000 feet from shore.
Action required: 705 - Other - as specified
Due 14 June 2004
Resolved 1 June 2004
Resolution: FCC License provided.
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 6 May 2004 Resolved
Provide proof of enrollent in drug testing consortium.
Action required: 705 - Other - as specified
Due 14 June 2004
Resolved 1 June 2004
Resolution: Drug Cards provided.
Documentation › Certificates/Documents
Issued 29 April 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 29 May 2003
Resolved 21 May 2003
Resolution: Owner provided Station License.
Documentation › Certificates/Documents
Issued 29 April 2003 Resolved
Provide FCC Operator's permit prior to operating beyond 1000' from shore.
Action required: 705 - Other - as specified
Due 29 May 2003
Resolved 21 May 2003
Resolution: Capt provided FCC operator''''s permit.
Documentation › Manifests/Lists
Issued 29 April 2003 Resolved
Provide emergency instruction list. LEGACY COMPONENT DESC: Muster List/Emergency Instructions
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 21 May 2003
Resolution: Owner provided Emergency Instruction List.
Communications › Radio Communications
Issued 29 April 2003 Resolved
Provide proof of registration on EPIRB. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 21 May 2003
Resolution: Owner provided proof of registration on EPIRB.
Accommodation/Occupational Safety › Medical/First Aid
Issued 29 April 2003 Resolved
Provide CG approved First Aid kit. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 21 May 2003
Resolution: Owner provided CG approved first aid kit.
Accommodation/Occupational Safety › Occupational Safety
Issued 29 April 2003 Resolved
Provide machinery guard over PTO on main engine. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 21 May 2003
Resolution: Owner provided machinery guard over PTO.
Documentation › Certificates/Documents
Issued 3 April 2001 Resolved
PROVIDE ONBOARD VALID FCC SAFETY CERTIFICATE IN ACCORDANCE WITH TITLE 47 CFR PRIOR TO 03 MAY01. LEGACY COMPONENT DESC: FCC Safety Certificate
Condition: Unknown
Due 3 May 2001
Resolved 21 May 2003
Resolution: Owner provided Safety certificate.
Documentation › Certificates/Documents
Issued 3 April 2001 Resolved
PRIOR TO CARRYING MORE THAN SIX PASSENGERS, INCLUDING AT LEAST ONE FOR HIREPROVIDE ONBOARD A VALID STABILITY LETTER FOR THE VESSEL IN ACCORDANCE WITH 46 CFR 176.306 LEGACY COMPONENT DESC: Stability Letter
Condition: Unknown
Due 3 May 2001
Resolved 21 May 2003
Resolution: Owner provided Stability letter.
Deck/Cargo
Issued 22 February 2001 Resolved
Provide ground tackle IAW 46 CFR 184.300
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Lifesaving
Issued 22 February 2001 Resolved
13 OCMI to determine operating area for EPIRB requirements IAW 46 CFR 180.64.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Lifesaving
Issued 22 February 2001 Resolved
14 OCMI to determine life float requirements for operating area IAW 46 CFR 176.808.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Lifesaving
Issued 22 February 2001 Resolved
Provide ring buoy IAW 46 CFR 180.70.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Fire Fighting
Issued 22 February 2001 Resolved
Mount B-II fire extinguisher.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Lifesaving
Issued 22 February 2001 Resolved
Provide approved first aid kit IAW 46 CFR 184.710.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Lifesaving
Issued 22 February 2001 Resolved
Demonstrate man overboard and fire drill IAW 46 CFR 176.808.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Construction/Loadline
Issued 22 February 2001 Resolved
Permanently mark on hull the vessel's Official Number IAW 46 CFR 67.121.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Engineering
Issued 22 February 2001 Resolved
Provide starter and ignition interlock IAW 46 CFR 182.460 (e).
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Engineering
Issued 22 February 2001 Resolved
22 Provide warning label for blower IAW 46 CFR 182.460 (e).
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Fire Fighting
Issued 22 February 2001 Resolved
20 Provide three (3) 2.5 gal fire buckets.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Lifesaving
Issued 22 February 2001 Resolved
Provide crew requirements.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Lifesaving
Issued 22 February 2001 Resolved
Provide life saving appliances IAW 46 CFR 180.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Documentation
Issued 22 February 2001 Resolved
Provide drug testing requirements.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Documentation
Issued 22 February 2001 Resolved
Provide valid Certificate of Documentation.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Lifesaving
Issued 22 February 2001 Resolved
Provide emergency broadcast placard.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Documentation
Issued 22 February 2001 Resolved
Provide FCC license and certificates.
Condition: Unknown
Due 22 March 2001
Resolved 21 May 2003
Resolution: Owner provided FCC license and certificate.
Documentation
Issued 22 February 2001 Resolved
Provide training log.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Navigation
Issued 22 February 2001 Resolved
Provide Charts and Pubs for local area.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Lifesaving
Issued 22 February 2001 Resolved
Provide distress flares IAW 46 CFR 180.68
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Navigation
Issued 22 February 2001 Resolved
Provide whistle/horn IAW 72 COLREGS, Annex III, 1.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Navigation
Issued 22 February 2001 Resolved
Provide separate circuit for anchor light.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001

Casualty record · 2

3 April 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3445696
31 May 2015Routine · role: Involved in a Marine Casualty · activity 5141683
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

RIGHT NOW (2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.